Search NASA⌕ Search

SEARCH · Search NASA

Results for “sufficient statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Anapole moment of neutrinos and radioactive sources near liquid xenon detectors

We show that placing a radioactive source such as 51 Cr near a liquid xenon detector may allow us to detect the contribution induced by the anapole moment to neutrino-electron scattering in the Standard Model (SM) at the 1 − 2⁢𝜎 level. Although the anapole moment of neutrinos induces a scattering rate with the same spectral shape as the neutral and charged current contributions, exposures of ∼ 60 ton × source run at XENONnT or XLZD may be enough to accumulate sufficient statistics for a detection. We also discuss a simple model where the anapole moment of neutrinos is enhanced or decreased with respect to the SM expectation, further demonstrating how a potential measurement of the anapole moment of neutrinos would allow us to constrain new physics.

dark matter direct detection↗

Tracking Fast Small Color Dipoles through Strong Gluon Fields at the LHC

We argue that the process {gamma}+A{yields}J/{psi}+'gap'+X at large momentum transfer q{sup 2} provides a quick and effective way to test the onset of a novel perturbative QCD regime of strong absorption for the interaction of small dipoles at the collider energies. We find that already the first heavy-ion run at the LHC will allow one to study this reaction with sufficient statistics via ultraperipheral collisions, hence probing the interaction of qq dipoles of sizes {approx}0.2 fm with nuclear media down to x{approx}10{sup -5}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Are X-rays the key to integrated computational materials engineering?

The ultimate dream of materials science is to predict materials behavior from composition and processing history. Owing to the growing power of computers, this long-time dream has recently found expression through worldwide excitement in a number of computation-based thrusts: integrated computational materials engineering, materials by design, computational materials design, three-dimensional materials physics and mesoscale physics. However, real materials have important crystallographic structures at multiple length scales, which evolve during processing and in service. Moreover, real materials properties can depend on the extreme tails in their structural and chemical distributions. This makes it critical to map structural distributions with sufficient resolution to resolve small structures and with sufficient statistics to capture the tails of distributions. For two-dimensional materials, there are high-resolution nondestructive probes of surface and near-surface structures with atomic or near-atomic resolution that can provide detailed structural, chemical and functional distributions over important length scales. Furthermore, there are no nondestructive three-dimensional probes with atomic resolution over the multiple length scales needed to understand most materials.

36 MATERIALS SCIENCE↗

TH-D-16A-01: Medical Physics Workshop: Editorial Vision and Guidance On Writing and Reviewing Papers

On January 1, 2014, editorial leadership of Medical Physics passed from esteemed long-time Editor Bill Hendee to a collective editorial group composed of the three presenters listed above. In this presentation, we would like to outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. Vision for Medical Physics and current initiatives: Jeff Williamson, Editor-in-Chief We cannot improve on Dr. Hendee's succinct vision statement “to continue the Journal's tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be s the preeminent forum for electronic exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; or (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities we face are: are electronic-only and open access publishing; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. To address these issues over the next 3 years, we have reduced the size of our Editorial Board and focused its efforts on improving the Journal's impact through 4 working groups (WGs): WG-1: Review process quality and selectivity Creation of 120 member Board of Associate Editors to improve review uniformity by placing Ms. management in fewer hands New reviewer guidelines and templates Answer: “what is the scope of medical physics research?” Recursive taxonomy for tagging review expertise and article contents WG-2 Improving reader experience Redesigning http://MedPhys.org to host interactive features and gateway to electronic issue archive Experimentation with interactive features beginning with “Point/Counterpoint” Data mining and Journal quality evaluation Find out who are audiences are Identify characteristics of high impact articles Measure effectiveness of innovations Outreach to related communities Special issues presenting high-impact work in designated subcommunities Addressing the needs of new research constituencies: engineers, biophysicists, clinicians Guidelines and templates for reviewers and associate editors: Shiva Das, Therapy Physics Editor We will discuss the Med. Phys. review process and a new initiative to create review templates that attempts to address current shortcomings. Template design is informed by the literature on of the review process effectiveness and practices of other journals. Its goals are to provide authors more constructive criticism to improve the manuscript; quantifying perceived importance and potential impact; and providing structured sections that prompt the reviewer to addresses important technical and editorial elements. While the template is recommended to be used, reviewers could alternatively enter their comments in the older free-form style. The expectations of the template are that it will enable consistently thorough, high quality reviews that accurately separate acceptable vs. substandard submissions but continue our tradition of helping authors to enhance papers with high potential. Ultimately, the goal is to reduce variability and subjectivity in the peer-review process, in turn leading to articles with higher research and clinical impact. We will also discuss interesting perspectives from several journals on aspects of the peer-review process such as public input via comments, influence of author-suggested reviewers, and bias in reviewer selection. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics Ms. must include a clear and concise statement of the novelty and clinical and/or scientific importance of their work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; or first demonstration that an existing engineering solution solves a clinical problem. Authors must also include: sufficient background information and rationale; enough detail that the work can be reproduced by others; sufficient statistical analysis to refute or validate their hypothesis, how it compares to; is distinct from, and improves upon others' work; and the limitations of their study. When the authors receive critiques from the referees and associate editor, the authors should provide a detailed point-bypoint response to each comment. We now ask that the authors' rebuttal include the text of the original criticism, the authors' response, and the modified text along with the line numbers in the revised article. We also ask that the new text be highlighted in a different font color in the revised submission. These changes and others will be discussed. Their purpose is to facilitate the review process.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

TH-C-204-00: Medical Physics Workshop: An Update On the Journal’s Improvement Activities and Guidance On Writing and Reviewing Papers

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗

TH-C-204-01: Vision for Medical Physics and Status of Current Initiatives

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗

TH-C-204-02: Improving Manuscript Quality Via Structured Reviews, Enhanced Scientific Category Taxonomy, and Outreach

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗

TH-C-204-03: Writing Good Scientific Papers and Responding to Critiques

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗

Imaging Bragg Edge Analysis TooLs for Engineering Structures (iBeatles)

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) provides pulsed neutrons with energies varying from epithermal to cold. In preparation for VENUS, the neutron imaging beamline to be located at beam port 10, we have performed a series of experiments focused on wavelength-dependent radiography and computed tomography for a broad range of applications, from materials science to biological tissues.One of the time-of-flight (TOF) techniques that is of interest to the scientific community is the 2-dimensional mapping of phases and average crystalline plane orientation in samples both ex-situ and during applied stresses such as tensile loading and heating. This technique is known as Bragg edgeimaging and relies on the identification of changes of transmission values, fitting of the edge to measure its displacement, and thus identify the shift in lattice parameter due to stresses. One of the challenges of TOF imaging measurements is the amount of data and the inability to observe Bragg edge shifts in real time during an experiment. Thus, we have been focusing on creating a Python-based interface that allows fast data processing and instantaneous mapping and fitting of the Bragg edges, and their evolution through time. Python libraries and Jupyter notebooks have been implemented to facilitate decision making during an experiment. The advantage of the notebooks is the possibility to guide an experiment as they can quickly process and display Bragg edge data. These notebooks can be used independently, or can be combined in a Python Graphical User Interface (GUI) tool called iBeatles. This interface permits visualization and fitting of the Bragg edges, and ultimately back-projects the fitting results onto the radiographs to display a strain map. Assuming data collection has sufficient statistics, the strain mapping analysis can be performed on a pixel-by-pixel basis. This development is a step forward toward a better user experience at the future VENUS beamline in terms of live feedback and productivity. Analysis that used to take days of switching between different applications can now be done in minutes within the

Bilheux, JeanChristophe [Oak Ridge National Labora↗

Convective and Turbulent Motions in Nonprecipitating Cu. Part III: Characteristics of Turbulence Motions

Velocity field in a nonprecipitating Cu under BOMEX conditions, simulated by SAM with 10-m resolution and spectral bin microphysics is separated into the convective part and the turbulent part, using a wavelet filtering. In Part II of the study properties of convective motions of this Cu were investigated. Here in Part III of the study, the parameters of cloud turbulence are calculated in the cloud updraft zone at different stages of cloud development. The main points of this study are (i) application of a fine-scale LES model of a single convective cloud allowed a direct estimation of turbulence parameters using the resolved flow in the cloud and (ii) the separation of the resolved flow into the turbulence flow and the nonturbulence flow allowed us to estimate different turbulent parameters with sufficient statistical accuracy. We calculated height and time dependences of the main turbulent parameters such as turbulence kinetic energy (TKE), spectra of TKE, dissipation rate, and the turbulent coefficient. It was found that the main source of turbulence in the cloud is buoyancy whose contribution is described by the buoyancy production term (BPT). The shear production term (SPT) increases with height and reaches its maximum near cloud top, and so does BPT. In agreement with the behavior of BPT and SPT, turbulence in the lower cloud part (below the inversion level) is weak and hardly affects the processes of mixing and entrainment. The fact that BPT is larger than SPT determines many properties of cloud turbulence. For instance, the turbulence is nonisotropic, so the vertical component of TKE is substantially larger than the horizontal components. Another consequence of the fact that BPT is larger than STP manifests itself in the finding that the turbulence spectrum largely obeys the -11/5 Bolgiano–Obukhov scaling. The classical Kolmogorov -5/3 scaling dominates for the low part of a cloud largely at the dissolving stage of cloud evolution. Using the spectra obtained we evaluated an “effective” dissipation rate which increases with height from nearly zero at cloud base up to 20 cm 2 s -3 near cloud top. The coefficient of turbulent diffusion was found to increase with height and ranged from 5 m 2 s -1 near cloud base to 25 m 2 s -1 near cloud top. In conclusion, the possible role of turbulence in the process of lateral entrainment and mixing is discussed.

54 ENVIRONMENTAL SCIENCES↗

Shared Genomic Regions Underlie Natural Variation in Diverse Toxin Responses

Phenotypic complexity is caused by the contributions of environmental factors and multiple genetic loci, interacting or acting independently. Studies of yeast and Arabidopsis often find that the majority of natural variation across phenotypes is attributable to independent additive quantitative trait loci (QTL). Detected loci in these organisms explain most of the estimated heritable variation. By contrast, many heritable components underlying phenotypic variation in metazoan models remain undetected. Before the relative impacts of additive and interactive variance components on metazoan phenotypic variation can be dissected, high replication and precise phenotypic measurements are required to obtain sufficient statistical power to detect loci contributing to this missing heritability. Here, we used a panel of 296 recombinant inbred advanced intercross lines of Caenorhabditis elegans and a high-throughput fitness assay to detect loci underlying responses to 16 different toxins, including heavy metals, chemotherapeutic drugs, pesticides, and neuropharmaceuticals. Using linkage mapping, we identified 82 QTL that underlie variation in responses to these toxins, and predicted the relative contributions of additive loci and genetic interactions across various growth parameters. Additionally, we identified three genomic regions that impact responses to multiple classes of toxins. These QTL hotspots could represent common factors impacting toxin responses. We went further to generate near-isogenic lines and chromosome substitution strains, and then experimentally validated these QTL hotspots, implicating additive and interactive loci that underlie toxin-response variation.

59 BASIC BIOLOGICAL SCIENCES↗

Efficient Speaker Verification Using Gaussian Mixture Model Component Clustering

In speaker verification (SV) systems that employ a support vector machine (SVM) classifier to make decisions on a supervector derived from Gaussian mixture model (GMM) component mean vectors, a significant portion of the computational load is involved in the calculation of the a posteriori probability of the feature vectors of the speaker under test with respect to the individual component densities of the universal background model (UBM). Further, the calculation of the sufficient statistics for the weight, mean, and covariance parameters derived from these same feature vectors also contribute a substantial amount of processing load to the SV system. In this paper, we propose a method that utilizes clusters of GMM-UBM mixture component densities in order to reduce the computational load required. In the adaptation step we score the feature vectors against the clusters and calculate the a posteriori probabilities and update the statistics exclusively for mixture components belonging to appropriate clusters. Each cluster is a grouping of multivariate normal distributions and is modeled by a single multivariate distribution. As such, the set of multivariate normal distributions representing the different clusters also form a GMM. This GMM is referred to as a hash GMM which can be considered to a lower resolution representation of the GMM-UBM. The mapping that associates the components of the hash GMM with components of the original GMM-UBM is referred to as a shortlist. This research investigates various methods of clustering the components of the GMM-UBM and forming hash GMMs. Of five different methods that are presented one method, Gaussian mixture reduction as proposed by Runnall's, easily outperformed the other methods. This method of Gaussian reduction iteratively reduces the size of a GMM by successively merging pairs of component densities. Pairs are selected for merger by using a Kullback-Leibler based metric. Using Runnal's method of reduction, we were able to achieve a factor of 2.77 reduction in a posteriori probability calculations with no loss in accuracy when the original UBM consisted of 256 component densities. When clustering was implemented with a 1024 component UBM, we achieved a computation reduction of 5 with no loss in accuracy and a reduction by a factor of 10 with less than 2.4% relative loss in accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectroscopic Investigation of p-Shell Lambda Hypernuclei by the (e,e'K + ) Reaction

Hypernuclear spectroscopy is a powerful tool to investigate Lambda-N interaction. Compared with other Lambda hypernuclei productions, electroproduction via the (e,e'K+) reaction has the advantage of exciting states deeply inside of the hypernucleus and achieving sub-MeV energy resolution. The E05-115 experiment, which was successfully performed in 2009, is the third generation hypernuclear experiment in JLab Hall C. A new splitter magnet and electron spectrometer were installed, and beam energy of 2.344 GeV was selected in this experiment. These new features gave better field uniformity, optics quality and made the tilt method more effective in improving yield-to-background ratio. The magnetic optics of the spectrometers were carefully studied with GEANT simulation, and corrections were applied to compensate for the fringe field cross talk between the compact spectrometer magnets. The non-linear least chi-squared method was used to further calibrate the spectrometer with the events from Lambda, Sigma0 and B12Lambda and uniform magnetic optics as well as precise kinematics were achieved. Several p-shell Lambda hypernuclear spectra, including B 12 Λ , Be 10 Λ , He 7 Λ , were obtained with high energy resolution and good accuracy. For B 12 Λ , eight peaks were recognized with the resolution of ~540keV (FWHM), and the ground state binding energy was obtained as 11.529 ± 0.012(stat.) ± 0.110(syst.) MeV. Be 10 Λ , twelve peaks were recognized with the resolution of ~520keV (FWHM), and the binding energy of the ground state was determined as 8.710 ± 0.059(stat.) ± 0.114(syst.) MeV. For He 7 Λ , three peaks were recognized with the resolution of ~730keV, and the ground state binding energy was obtained as 5.510 ± 0.050(stat.) ± 0.120(syst.) MeV. Compared with the published data of B 12 Λ from the JLab Hall A experiment, four extra peaks were fitted and interpreted thanks to the highest ever energy resolution and sufficient statistics. The determined binding energy of Be 10 Λ provides new information on charge symmetry breaking effect in the Lambda-N interaction. Compared with the results of He7Lambda from the E01-011 experiment, the ground state position is consistent with 4 times more statistics, and two extra peaks corresponding to excited states were recognized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High energy x-ray and neutron studies of disordered energy-related materials at extreme conditions

The fundamental scientific accomplishments are: (1) advances in a general description of the liquid state by employing structural models constrained by measurements to interpret experimental results and extend them to liquids in general, with special emphasis on (2) The structure of the high-temperature crystal and molten UO 2 and 3) water. Specifically, samples of UO 2 and water were probed using high-energy x-rays at the Advanced Photon Source. The high Z of UO 2 , and the 2-3mm diameter droplet shape of the molten sample, means that >100keV X-rays are required to minimize absorption and multiple scattering, which can distort the measured structure factor. A high flux of x-rays is also required to obtain sufficient statistical accuracy in short (a few seconds) measurement times. The scattered x-ray data were analyzed and pair distribution functions, extracted that characterize the local and long-range atomic structure of the material. The measurements of the hot UO 2 solid show a substantial increase in oxygen disorder and, upon melting, the average U-O coordination was found to decrease from 8 to 6.7±0.5. The research incorporated development of diffraction techniques, sample environment optimization and state-of-the-art simulation techniques. The symbiotic nature of the advances in simulation and experiment allowed for a more focused and informed development of future experiments, effective use of expensive beam time and generated new research agendas for the growing number of research groups, within the US and internationally, that focus on the structure of liquids. Molecular dynamics (MD) provided detailed information when combined with high-quality XN data including addressing key issues in liquids; the relationship between cooling path, structure and fictive temperature, and the trade-offs between network over connectedness in liquids containing low-coordination cations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gamma-ray imaging and holdup assays of 235-F PuFF cells 1 & 2

Savannah River National Laboratory (SRNL) Nuclear Measurements (L4120) was tasked with performing enhanced characterization of the holdup in the PuFF shielded cells. Assays were performed in accordance with L16.1-ADS-2460 using two high-resolution gamma-ray detectors. The first detector, an In Situ Object Counting System (ISOCS)-characterized detector, was used in conjunction with the ISOCS Geometry Composer software to quantify grams of holdup. The second detector, a Germanium Gamma-ray Imager (GeGI), was used to visualize the location and relative intensity of the holdup in the cells. Carts and collimators were specially designed to perform optimum assays of the cells. Thick, pencil-beam tungsten collimators were fabricated to allow for extremely precise targeting of items of interest inside the cells. Carts were designed with a wide range of motion to position and align the detectors. A total of 24 measurements were made, each typically 24 hours or longer to provide sufficient statistical precision. This report presents the results of the enhanced characterization for cells 1 and 2. The measured gram values agree very well with results from the 2014 study. In addition, images were created using both the 2014 data and the new GeGI data. The GeGI images of the cells walls reveal significant Pu-238 holdup on the surface of the walls in cells 1 and 2. Additionally, holdup is visible in the two pass-throughs from cell 1 to the wing cabinets. This report documents the final element (exterior measurements coupled with gamma-ray imaging and modeling) of the enhanced characterization of cells 1-5 (East Cell Line).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-depth Measurement of Fast Neutrons

A spallation based multiplicity detector has been constructed and deployed to the Kimballton Underground Research Facility to measure the cosmogenic fast neutron flux anti-coincident from the initiating muon. Two of the three planned measurements have been completed (~380 and ~600 m.w.e) with sufficient statistics. The third measurement at level 14 (~4450 m.w.e.) is currently being performed. Current results at ~600 m.w.e. compare favourably to the one previous measurement at 550 m.w.e. For neutron energies between 100 and 200 MeV measurements at ~380 m.w.e. produce fluxes between 1e -8 and 7e -9 n/cm 2 /s/MeV and at ~600 m.w.e. measurements produce fluxes between 7e -9 and 1e -11 n/cm 2 /s/MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-‘omic’ analyses of the dynamics, mechanisms, and pathways for carbon turnover in grassland soil under two climate regimes

Soil microbial activity drives the carbon and nitrogen cycles and is an important determinant of atmospheric trace gas turnover, yet most soils are dominated by microorganisms with unknown metabolic capacities. This knowledge gap precludes meaningful predictions of relationships between microorganism types and their biogeochemical functions. Specifically, as climate change physically alters terrestrial ecosystems, the impact on microbial consortia and potential consequences for release of carbon and other nutrients from soils are difficult to predict. In this project, we investigated the identities, activity, and functional potential of microorganisms residing in a well characterized grassland ecosystem (the Angelo Coast Range Reserve) undergoing a controlled 14-year rainfall extension climate change experiment. The research was achieved using a combination of “omics”-based technologies, including genome-resolved metagenomics, transcriptomics, and proteomics. The approach allowed us to capture multiple facets of community ecology and activity in situ. Supported by this award, significant progress was made in addressing the grand challenge of achieving genome-resolution for very complex soil microbial communities. In addition to improvements in the methodology, the research required new approaches to define the 3-dimentional distributions of microorganisms and their metabolic traits in soils and to decipher the impact of climate. Underpinning such analyses was the need for sufficient statistical power to test for geographic, soil depth and rainfall controls on community composition and metabolic properties. This required that we scale up throughput substantially. We overcame significant technical barriers to achieve complex microbial community resolution.

54 ENVIRONMENTAL SCIENCES↗

On the use of Graphs for Test Sequence Selection

This report demonstrates that applying graph theory techniques provides a way to obtain sufficient statistics in finding errors when testing complex state machines. It discusses how to define the tests, then demonstrates how to automatically generate test suites that diversify test cases, subject to constraints. If included within a continuous integration approach, these constructs provide an unbiased means to systematically check for errors within the latest controller software release.

97 MATHEMATICS AND COMPUTING↗