Search NASA⌕ Search

SEARCH · Search NASA

Results for “superconducting radiofrequency cavities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Co-Sputtering of Nb3Sn into SRF Cavity Using Composite Target and Optimizing Surface Homogeneity

Nb₃Sn coating method for superconducting radiofrequency (SRF) cavity has been developed following co-sputtering of Nb-Sn composite target using a DC cylindrical sputter coater. Deposition parameters and annealing strategies were optimized for uniform Nb₃Sn coating. 1.5 m Nb-Sn film was deposited onto 2.6 GHz Nb SRF cavity and annealed at 600 C for 6 h, followed by 950 C for 1 h. Cryogenic RF testing confirmed Nb₃Sn formation with Tc = 17.8 K. A post-annealing light Sn recoating process improved the cavity s performance, achieving Q₀ = 8.5 10⁸ at 2.0 K.

Shakel, M. S. [Old Dominion U.]↗

Origins of quench in buffered chemical polished and low temperature baked SRF cavities

Electropolishing (EP) and buffered chemical polishing (BCP) are conventional surface preparation techniques for superconducting radiofrequency (SRF) cavities that remove damaged material from the cavity surface. One main issue with EP and BCP treated SRF cavities is high field Q-slope (HFQS), a drop in quality factor at high gradients that limits quench field. High gradient performance in EP cavities can be improved by applying a low temperature bake (LTB), but LTB does not consistently remove HFQS in BCP cavities. There is no consensus as to the why LTB is not effective on BCP prepared cavities, and the cause of HFQS in BCP cavities is not well understood. We examine the origins of quench in EP, BCP, EP+LTB, and BCP+LTB treated SRF cavities. We also show the effect of these treatments on the onset of HFQS, heating within the cavity up to quench, concentration of free hydrogen, and surface roughness.

43 PARTICLE ACCELERATORS↗

Comparing the Effectiveness of Low Temperature Bake in EP and BCP Cavities

Electropolishing (EP) and buffered chemical polishing (BCP) are conventional surface preparation techniques for superconducting radiofrequency (SRF) cavities. Both EP and BCP treated SRF cavities display high field Q-slope (HFQS) which degrades performance at high gradients. While high gradient performance in EP cavities can be improved by introducing oxygen via a low temperature bake (LTB) of 120^{°}C by 48 hours, LTB does not consistently remove HFQS in BCP cavities. There is no consensus as to why LTB is not effective on BCP prepared cavities. We examine quench in EP, BCP, EP+LTB, and BCP+LTB treated 1.3 GHz single-cell Nb cavities by studying the heating behavior with field using a temperature mapping system. Cavity performance is correlated to characterizations of surface impurity profile obtained via time of flight secondary ion mass spectrometry studies. We observe a difference in near surface hydrogen concentration following BCP compared to EP that may suggest that the causes of quench in EP and BCP cavities are different.

43 PARTICLE ACCELERATORS↗

Comparison of copper and aluminum as the thermal link material for conduction-cooled accelerator cavities

Cryocooler conduction-cooling has recently emerged as a new frontier for cryogenic cooling for superconducting radiofrequency (SRF) cavities. In this scheme, an SRF cavity is mechanically coupled to a closed-cycle cryocooler using linkages made of high thermal conductivity metals. In this note, we compare the thermal transport properties of high purity aluminum and high purity copper as applied to SRF cavity conduction cooling. We show that copper can enable faster cooldown than aluminum from room temperature to the base temperature near 4 K and behave equally well or better during steady state cavity operation near the base temperature.

36 MATERIALS SCIENCE↗

Cylindrical Magnetron Development for Nb3sn Deposition via Magnetron Sputtering

Due to its better superconducting properties (critical temperature Tc~ 18.3 K, superheating field Hsh~ 400 mT), Nb₃Sn is considered as a potential alternative to niobium (Tc~ 9.25 K, Hsh~ 200 mT) for superconducting radiofrequency (SRF) cavities for particle acceleration. Magnetron sputtering is an effective method to produce superconducting Nb₃Sn films. We deposited superconducting Nb₃Sn films on samples with magnetron sputtering using co-sputtering, sequential sputtering, and sputtering from a stoichiometric target. Nb₃Sn films produced by magnetron sputtering in our previous experiments have achieved DC superconducting critical temperature up to 17.93 K and RF superconducting transition at 17.2 K. A magnetron sputtering system with two identical cylindrical cathodes that can be used to sputter Nb₃Sn films on cavities has been designed and is under development now. We report on the design and the current progress on the development of the system.

43 PARTICLE ACCELERATORS↗

The Influence of Strain Path and Heat Treatment Variations on Recrystallization in Cold-Rolled High-Purity Niobium Polycrystals

With the standard material and cavity production guidelines, the properties and performance of industrially produced high-purity niobium superconducting radiofrequency (SRF) cavities are unpredictably variable. Currently, assembled niobium SRF cavities undergo post-purification vacuum heat treatment at 800 °C for three hours to remove hydrogen and increase performance; however, recent work has shown significant improvements in cavity performance when annealed between 900–1000 °C, causing recrystallization (Rx). Increasing the annealing temperature and/or the heating rate should facilitate the onset of Rx, resulting in a greater reduction in the density of geometrically necessary dislocations (GNDs) that are strongly associated with the degradation of cavity performance via trapped magnetic flux. Improving the SRF community's understanding of the influence of both heat treatment and deformation history on the resulting microstructure and Rx behavior in high-purity niobium is needed. This fundamental metallurgy is critical for identifying improved specifications for the consistent production of high-performing niobium SRF cavities. This research investigates variations in deformation paths, heating rates, and annealing temperatures on Rx of deformed samples of polycrystalline high-purity niobium. To assess the effects of strain path, samples were cold-rolled to ~30% reduction prior to annealing, with half of the sample set rolled parallel to the as-received niobium sheet and the other half in the transverse direction.

36 MATERIALS SCIENCE↗

High-$Q_0$ treatment of CEBAF 1.5 GHz SRF cavities

The Continuous Electron Beam Accelerator Facility (CEBAF) was the first large-scale accelerator to employ superconducting radiofrequency (SRF) cavities for continuous-wave operation. Ongoing research and development efforts continue to focus on increasing the intrinsic quality factor (Q 0 ) of these cavities in order to reduce cryogenic losses while maintaining operational gradients. Here, in this work, we report on the application of high-Q 0 surface treatments to single-cell and multicell C100 and C75 style 1.5 GHz niobium cavities used in the CEBAF accelerator. Nitrogen infusion and oxygen alloying via medium-temperature baking were applied under heat-treatment constraints relevant to existing cavity hardware. Both processes yielded substantial improvements in Q 0 at moderate accelerating gradients, achieving values of approximately 2 × 10 10 at 2.07 K and 20 MV/m. The effectiveness of nitrogen infusion at reduced annealing temperatures and the successful extension of oxygen alloying to multicell cavities are demonstrated. These results establish viable pathways for implementing high-Q 0 treatments in CEBAF-compatible cavities and support future integration into cryomodules for reduced operational cryogenic load.

Dhakal, Pashupati [Thomas Jefferson National Accel↗

Exploration of Optimizing FPGA-based Qubit Controller for Experiments on Superconducting Quantum Computing Hardware

This work explores avenues and target areas for optimizing FPGA-based control hardware for experiments conducted on superconducting quantum computing systems and serves as an introduction to some of the current research at the intersection of classical and quantum computing hardware. With the promise of building larger-scale error-corrected quantum computers based on superconducting qubit architecture, innovations to room-temperature control electronics are needed to bring these quantum realizations to fruition. The QICK (Quantum Instrumentation Control Kit) is one leading experimental FPGA-based implementations. However, its integration into other experimental quantum computing architectures, especially those using superconducting radiofrequency (SRF) cavities, is largely unexplored. We identify some key target areas for optimizing control electronics for superconducting qubit architectures and provide some preliminary results to the resolution of a control pulse waveform. With optimizations targeted at 3D superconducting qubit setups, we hope to bring to light some of the requirements in classical computational methodologies to bring out the full potential of this quantum computing architecture, and to convey the excitement of progress in this research.

43 PARTICLE ACCELERATORS↗

Superconducting Radio-frequency Cavity Fault Classification Using Machine Learning at Jefferson Laboratory

We report on the development of machine learning models for classifying C100 superconducting radiofrequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Of the 418 SRF cavities in CEBAF, 96 are designed with a digital low-level RF system configured such that a cavity fault triggers recordings of RF signals for each of eight cavities in the cryomodule. Subject matter experts analyze the collected time-series data and identify which of the eight cavities faulted first and classify the type of fault. This information is used to find trends and strategically deploy mitigations to problematic cryomodules. However, manually labeling the data is laborious and time-consuming. By leveraging machine learning, near real-time - rather than postmortem - identification of the offending cavity and classification of the fault type has been implemented. We discuss the performance of the machine learning models during a recent physics run. We also discuss efforts for further insights into fault types through unsupervised learning techniques and present preliminary work on cavity and fault prediction using data collected prior to a failure event.

Tennant, C. D.↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, Sajini A.K. [Fermilab] (ORCID:00000002↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a key limitation to achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. Addressing this challenge requires a detailed understanding of the generation and transport of FE-induced radiation; however, the absence of standardized measurement protocols complicates comparisons across different testing stages and facilities. This work presents initial steps toward a quantitative, systematic framework for analyzing FE-induced radiation using Geant4 simulations. We model four cavity types to be deployed in Fermilab’s Proton Improvement Plan-II (PIP-II) linac - HB650, LB650, SSR2, and SSR1 - to investigate radiation signatures and their dependence on emission conditions. By integrating simulation results with radiation diagnostics, our goal is to identify probable emission sites, enhance diagnostic accuracy, and optimize detector placement. Ultimately, this approach seeks to inform cavity preparation, assembly, and testing procedures, enabling the delivery of FE-free SRF cryomodules for PIP-II.

Wijethunga, Sajini [Fermilab] (ORCID:0000000287659↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a key limitation to achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. Addressing this challenge requires a detailed understanding of the generation and transport of FE-induced radiation; however, the absence of standardized measurement protocols complicates comparisons across different testing stages and facilities. This work presents initial steps toward a quantitative, systematic framework for analyzing FE-induced radiation using Geant4 simulations. We model four cavity types to be deployed in Fermilab’s Proton Improvement Plan-II (PIP-II) linac - HB650, LB650, SSR2, and SSR1 - to investigate radiation signatures and their dependence on emission conditions. By integrating simulation results with radiation diagnostics, our goal is to identify probable emission sites, enhance diagnostic accuracy, and optimize detector placement. Ultimately, this approach seeks to inform cavity preparation, assembly, and testing procedures, enabling the delivery of FE-free SRF cryomodules for PIP-II.

Wijethunga, Sajini [Fermilab] (ORCID:0000000287659↗

Investigation of the effect of structural defects from hydride precipitation on superconducting properties of high purity SRF cavity Nb using magneto-optical and electron imaging methods

Abstract Nb is an elemental superconductor with a critical temperature of 9.3 K and is widely used to fabricate superconducting radiofrequency (SRF) cavities for particle accelerators. However, microstructural defects in Nb, such as grain boundaries (GBs) and dislocations, can act as pinning centers for magnetic flux that can degrade SRF cavity performance. Hydrogen contamination is also detrimental to SRF cavity performance due to the formation of normal conducting hydrides during cool down. In this study, disc shaped Nb bi-crystals extracted from high-purity large-grain Nb slices were investigated to study the effects of GBs, hydrogen, and dislocations on superconducting properties. Grain orientation and GB misorientation were measured using Laue x-ray diffraction and electron backscattered diffraction (EBSD) analyses. Cryogenic magneto-optical imaging was used to directly observe magnetic flux penetration below T c = 9.3 K. Damage caused by low temperature precipitation of hydrides and their dissolution upon reheating after cryogenic cycles was examined using electron channeling contrast imaging, and EBSD. The relationships between hydride formation, dislocation content, GBs, cryo-cooling, heat treatment (HT), and flux penetration indicate that both GB character and hydrogen content affect magnetic flux penetration. Such flux penetration could be facilitated by dislocation structures and low angle GBs resulting from hydride precipitation and HT.

36 MATERIALS SCIENCE↗

Advancements in HF-free bipolar pulsed electropolishing for next-generation superconducting cavities

Hydrofluoric acid (HF)-free bipolar pulsed electropolishing (BPEP) offers an environmentally sustainable alternative to conventional Buffered Chemical Polishing (BCP) and Electropolishing (EP) techniques for superconducting radiofrequency (SRF) cavities. Recent studies at Jefferson Lab have demonstrated that a single-cell 1.3 GHz niobium cavity processed using HF-free BPEP achieved an accelerating gradient Eacc of 35 MV/m with a quality factor Q0 of 1E10 at 2 K, following extensive research and optimization. This talk will highlight the challenges encountered in developing this technique, key insights gained from experimental studies, and ongoing efforts to enhance its capabilities. In particular, we will explore its potential for refining Nb3Sn-coated niobium cavities via vapor diffusion techniques and for electroplating Nb3Sn films onto various cavity substrates, contributing to the advancement of high-performance SRF systems.

Tian, Hui [Thomas Jefferson National Accelerator F↗

Fabrication of Nb3Sn by Magnetron Sputtering for Superconducting Radiofrequency Application

Particle accelerators are considered as an important device that has wide applications in cancer treatment, sterilizing waste, preserving foods, ion implantation in semiconductor industry, and in production of isotopes for medical applications. Superconducting radiofrequency (SRF) cavities are the building blocks of a linear particle accelerator. Current particle accelerators use niobium (Nb) superconductors as the sheet material to fabricate a single SRF cavity for particle acceleration. With better superconducting properties (critical temperature Tc ~ 18.3 K, superheating field Hsh~ 400 mT), Nb3Sn is considered a potential candidate in SRF technology. Magnetron sputtering is a promising deposition method to fabricate Nb3Sn thin films inside SRF cavities. Superconducting Nb3Sn films were fabricated on Nb and sapphire substrates by magnetron sputtering from a single stoichiometric Nb3Sn target, by multilayer sputtering of Nb and Sn followed by annealing, and by co-sputtering of Nb and Sn followed by annealing. The variation of morphological and superconducting properties was investigated for different substrate temperatures, annealing temperatures, annealing durations, and thicknesses. The film properties were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM), and energy dispersive X-ray spectroscopy (EDS). The films had crystalline Nb3Sn structure without any presence of poor superconducting Nb6Sn5 and NbSn2 phases. The highest Tc of the films fabricated from the stoichiometric target, multilayer sputtering and co-sputtering were 17.44, 17.93, and 17.66 K respectively. Finally, a cylindrical sputter coater with two identical magnetrons was designed and commissioned to fabricate Nb3Sn films inside a 2.6 GHz SRF cavity. The magnetrons were installed facing opposite to each other in a custom designed vacuum chamber and multilayers of Nb and Sn films on 1 cm2 Nb substrates replicating the beam tubes and equator locations of the cavity and the coated multilayered films were annealed at 950 °C for 3 h. The XRD of the as?deposited and annealed films confirmed the formation of Nb3Sn after the annealing. The dissertation discusses the fabrication process, characterized results of the fabricated films, the design of the cylindrical sputter coater and the preliminary data obtained from the sputter coater.

Sayeed, Md Nizam↗

Demonstration of $E$ acc = 10 MV m −1 with Nb 3 Sn cavities in a cryomodule

Accelerating cryomodules with superconducting cavities are key components for particle accelerators. The efficiency, energy gain and operating temperature of cavities drive the operating and capital costs; hence, advances in these areas enable future accelerators. While superconducting cavities are currently made from Nb, Nb 3 Sn, with a superconducting transition temperature and superheating field approximately twice that of Nb, is poised to substantially improve the efficiency and energy gain. We present results from the first cryomodule with two five-cell 1.5 GHz superconducting radiofrequency Nb cavities coated with Nb 3 Sn, which attained an accelerating gradient of ⩾10 MV m −1 with low cryogenic loss at 4.4 K.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of high-frequency gravitational waves using SRF cavities

Today, apart from some isolated R\&D efforts, there are no GW experiments, yet which explore a large part of the vast frequency range above the LIGO/Virgo band. It is planned to establish an experiment at DESY and Fermilab to search for high-frequency GWs in the frequency range of 10\,kHz to 100\,MHz. The basic idea is to use superconducting radiofrequency (SRF) cavities to detect tiny harmonic deformations induced by GWs which change the boundary conditions of the oscillating electromagnetic field. This paper summarizes the challenging environmental boundary requirements, and the R\&D to operate a cavity using a LLRF system which pushes beyond state-of-the-art accuracy and resolutions and a seismic noise mitigated cryostat at 1.8\,K. The focus of this paper is the warm and cold commissioning of a prototype cavity, built 20 years ago during the MAGO collaboration, and its first measurement in our collaborative research project.

Giaccone, Bianca [Fermilab]↗

Detection of high-frequency gravitational waves using SRF cavities

Today, apart from some isolated R&D efforts, there are no gravitational wave (GW) experiments, yet which explore a large part of the vast frequency range above the LIGO/Virgo band. It is planned to establish an experiment at Deutsches Elektronen-Synchrotron (DESY) and at the Superconducting Quantum Materials and Systems (SQMS) Center at Fermi National Accelerator Laboratory (Fermilab) to search for high-frequency GWs in the frequency range of 10 kHz to 100 MHz. The basic idea is to use superconducting radiofrequency (SRF) cavities to detect tiny harmonic deformations induced by GWs which change the boundary conditions of the oscillating electromagnetic field. This paper summarizes the challenging environmental boundary requirements, and the R&D to operate a cavity using a low level RF (LLRF) system which pushes beyond state-of-the-art accuracy and resolutions and a seismic noise mitigated cryostat at 1.8 K. The focus of this paper is the warm and cold commissioning of a prototype cavity, built 20 years ago during the MAGO collaboration, and its first measurement in our collaborative research project.

Wenskat, M. [DESY; Hamburg U.] (ORCID:000000016546↗