Search NASA⌕ Search

SEARCH · Search NASA

Results for “superfluid helium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design and Construction of a High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory, together with Lawrence Berkeley National Laboratory, is building a new High Field Vertical Magnet Test Facility (HFVMTF) to be situated in the Magnet Test Facility at Fermilab. The HFVMTF is jointly funded by the US DOE Offices of Science, High Energy Physics, and Fusion Energy Sciences, and will serve as a superconducting cable test facility for both communities. The background magnetic field for test samples is 15 T and will be produced by a magnet provided by LBNL operating at 1.9 K in superfluid helium. The samples will be placed in the background magnetic field, cooled to between 4.5 K and a user-specified upper limit, and will be powered with a super-conducting transformer at up to 100 kA. Additionally, this facility will be used to test high-field superconducting magnet models and demonstrators, including hybrid magnets, produced by the US Magnet Development Program. Presently, the various tasks of the project are at different stages of execution, from conceptual to ready-for-construction designs. Here, this paper describes the parameters and design status of the pit construction, cryostat, heat exchanger, lambda plate, power system, and quench protection and monitoring systems of the facility.

43 PARTICLE ACCELERATORS↗

High Force Spring Clamp System

This is the Final Technical Report for the work by Hyperboloid LLC using SBIR Grant # DE-SC0019579. The work responded to US DOE SBIR Topics FY2019, Phase 1, Release 1, August 13 2018, Topic: 30. a. (2) SRF cavity joining techniques that create vacuum seals without resorting to the use of bolted flanges in order to minimize particulates. Hyperboloid LLC designed, developed and tested the High Force Spring Clamp System characterized in Patent US 9756715 that is aimed at solving this topic. The patent is held by Thomas Jefferson National Accelerator Facility. The flange bolts are substituted with exceptionally high force, binder-clip-like “C” Clamps. The clamps are opened and applied by hydraulic based tooling called “Clamp Openers” using particle minimization methods. Model 1 Clamp reached the goal of sealing the SRF industry standard hexagonal section, aluminum alloy gasket, leak-free on a research cavity as determined by a superfluid helium challenge, at 2 K for 2 assembly cycles. Descriptions include the ANSYS calculations that determine the size and shape of the clamp, the details of the Clamp Opener construction, particle counts from sealing flanges using both bolts and clamps. Model 2 Clamp, at half the size, needing a softer metallic gasket to be successful, is more readily adaptable to Cryomodule designs. It was tested, but a needs soft gasket development to be successful.

43 PARTICLE ACCELERATORS↗

Letter of Intent: Muonium R&D/Physics Program at the MTA

With the planned turn-on of the PIP-II 800 MeV superconducting proton linac, Fermilab will potentially become the world's best laboratory at which to carry out fundamental muon measurements, sensitive searches for symmetry violation, and precision tests of theory. In preparation, we propose to develop the techniques that will be needed. An R&D and physics program is proposed at the Fermilab MeV Test Area to use the existing 400 MeV Linac to demonstrate the efficient production of a slow muonium beam using $\mu^+$ stopped in a ~100 $\mu$m-thick layer of superfluid helium, and to use that beam to measure muonium gravity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

C1Po2D-04: Cryogenic Testing of the First HL-LHC Q1/Q3 Cryo-Assembly at

In early 2023, Fermilab is conducting horizontal cryogenic testing of the first Q1/Q3 Cryo-Assembly for the high-luminosity LHC upgrade (HL-LHC). The Cryo-Assembly was installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of this test include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressure up to 18 bar with full helium recovery after a quench.

Rabehl, R.↗

MTA Secondary Beamline Production and Optics Optimization

A new secondary beamline was recently installed in the MeV Test Area (MTA) with the objective of enhancing mu+/mu- production by factors of 3/8 by using a tungsten target versus the conventional graphite production target using the 400 MeV Fermilab proton Linac beam. Ultra-low energy muon beams can support world-class physics experiments for fundamental muon measurements, sensitive searches for symmetry violation, and precision tests of theory. Extensive production studies have confirmed higher muon yield from heavy targets (tungsten vs carbon), but also, surprisingly, showed significant differences in production fluence and energy spectrum between modern hadronic models (GENIEhad) and between GEANT and MCNP. Studies are also underway towards a high-efficiency source of muonium by stopping the mu+ beam in superfluid helium. Muon fluxes can be measured at MTA including using higher-Z and novel target geometries to test hadronic and production models which are critical to understanding ongoing experiments (Mu2e) and will significantly impact the planning of future HEP experiments and planning PIP II facilities. The MTA beamline will additionally support a broad user muon test beam for future experiments and R&D.

Ahmed, Shiza↗

Research at UC Berkeley on the SPICE and HeRALD Dark Matter Experiments (Technical Report for DE-SC0022354)

The McKinsey and Pyle groups have taken on the responsibility to complete a number of critical tasks necessary for the successful completion of the TESSERACT project planning phase. In particular: 1) Transition Edge Sensor testing, characterization, and electromagnetic noise mitigation; 2) Design and testing of the athermal phonon detectors along with vibrational noise characterization and mitigation; 3) Testing and characterization of prototype detectors using silica, sapphire, gallium arsenide, and superfluid helium as detector materials. This grant supported efforts of graduate student Roger Romani toward these goals.

47 OTHER INSTRUMENTATION↗

Cryogenic Testing of HL-LHC Q1/Q3 Cryo-Assemblies at Fermilab

Fermilab is conducting horizontal cryogenic testing of Q1/Q3 Cryo-Assemblies for the high-luminosity LHC upgrade (HL-LHC). Cryo-Assemblies are installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of these tests include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressures up to 18 bar with full helium recovery after a quench. This paper presents the operational experience gained from the first tests as well as improvements for subsequent tests.

Rabehl, R. [Fermilab]↗

Fabrication of the HFVMTF Double-Bath Cryostat

The High Field Vertical Magnet Test Facility (HFVMTF) at Fermilab is designed to test superconducting magnets up to 20 tons and 1.3 meters in diameter. Central to the facility is a double-bath superfluid helium cryostat reaching 1.8 K at 1.2 bar. Integrated with a 15 T superconducting dipole from LBNL, HFVMTF supports HTS cable testing for fusion applications. This paper presents the design and fabrication of the cryostat, with a focus on two complex components: the 2 K heat exchanger and the lambda plate. The heat exchanger thermally links sub-atmospheric and pressurized helium baths. The 1.4-meter lambda plate provides thermal isolation and structural support for over 20 tons under 1.3 bar pressure differential. Finite Element Analysis validated the vessel’s integrity under maximum load conditions.

Bruce, Romain [Fermilab] (ORCID:0000000234200612)↗

Cryogenic testing of the first HL-LHC Q1/Q3 cryo-assembly at Fermilab

In early 2023, Fermilab is conducting horizontal cryogenic testing of the first Q1/Q3 cryo-assembly for the high-luminosity LHC upgrade (HL-LHC). The cryo-assembly was installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of this test include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressure up to 18 bar with full helium recovery after a quench. This paper presents the operational experience gained from this first test.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryogenic testing of HL-LHC Q1/Q3 cryo-assemblies at Fermilab

Fermilab is conducting horizontal cryogenic testing of Q1/Q3 cryo-assemblies for the high-luminosity LHC upgrade (HL-LHC). Cryo-assemblies are installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of these tests include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressure up to 18 bar with full helium recovery after a quench. This paper presents the operational experience gained from the first tests as well as improvement for subsequent tests.

Rabehl, R. [Fermilab] (ORCID:0000000311130030)↗

Fabrication of the HFVMTF Double-Bath Cryostat

The High Field Vertical Magnet Test Facility (HFVMTF) at Fermilab is designed to test superconducting magnets up to 20 tons and 1.3 meters in diameter. Central to the facility is a double-bath superfluid helium cryostat reaching 1.8 K at 1.2 bar. Integrated with a 15 T superconducting dipole from LBNL, HFVMTF supports HTS cable testing for fusion applications. This paper presents the design and fabrication of the cryostat, with a focus on two complex components: the 2 K heat exchanger and the lambda plate. The heat exchanger thermally links sub-atmospheric and pressurized helium baths. The 1.4-meter lambda plate provides thermal isolation and structural support for over 20 tons under 1.3 bar pressure differential. Finite Element Analysis validated the vessel's integrity under maximum load conditions.

Bruce, R. [Fermilab] (ORCID:0000000234200612)↗

Shape fluctuations and optical transition of He 2 * excimer tracers in superfluid He 4

Metastable He$_{2}^{*}$ excimer molecules have been utilized as tracer particles of the normal component in superfluid $^4$He (He II) which can be imaged via laser-induced fluorescence. These excimer molecules form tiny bubbles in He II and can bind to quantized vortices at sufficiently low temperatures, thereby allowing for direct visualization of vortex dynamics in an inviscid superfluid. However, the $a^{3}\Sigma^+_{u}$${\rightarrow}$$c^{3}\Sigma^+_{g}$ optical absorption line, which is responsible for the fluorescence imaging of the He$_{2}^{*}$ molecules, is controlled by fluctuations on the bubble shape, and its exact line profile is not known at low temperatures. In this paper, we present a bubble model for evaluating the surface fluctuation eigenmodes of the excimers in He II. The line profile of the $a^{3}\Sigma^+_{u}{\rightarrow}c^{3}\Sigma^+_{g}$ transition is calculated at different temperatures by considering both the zero-point and thermal fluctuations on the bubble shape. We show that, as the temperature drops from 2~K to 20 mK, the peak absorption strength is enhanced by a factor of about five, accompanying a blueshift of the peak location by about 2 nm. A double-peak line profile due to the rotational levels of the molecular core can be resolved. This bubble model also allows us to evaluate the stiffness of the He$_{2}^{*}$ bubbles and hence their diffusion constant in He II due to scattering off thermal phonons. Our results will aid the design of future experiments on imaging quantized vortices in He II using He$_{2}^{*}$ tracers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Shapes of rotating normal fluid He-3 versus superfluid He-4 droplets in molecular beams

Previous single-pulse extreme ultraviolet and X-ray coherent diffraction studies revealed that superfluid 4He droplets obtained in free jet expansion acquire sizable angular momentum, resulting in significant centrifugal distortion. Similar experiments with normal fluid 3He droplets may help elucidating the origin of the of the large degree of rotational excitation and highlight similarities and differences of dynamics in normal and superfluid droplets. Here, we present the first comparison of the shapes of isolated 3He and 4He droplets following expansion of the corresponding fluids in vacuum at temperatures as low as ~ 2 K. Large 3He and 4He droplets with average radii of ~160 nm and ~350 nm, respectively, were produced. We find that the majority of the 3He droplets in the beam correspond to rotating oblate spheroids with reduced average angular momentum ($\Lambda$) and reduced angular velocities ($\Omega$) similar to that of 4He droplets. Given the different physical nature of 3He and 4He, this similarity in $\Lambda$ and $\Omega$ may be surprising and suggest that similar mechanisms induce rotation regardless of the isotope. We hypothesized that the observed distribution of droplet sizes and angular momenta stem from processes in the dense region close to the nozzle. In this region, the significant velocity spread and collisions between the droplets induce excessive rotation followed by droplet fission. The process may repeat itself several times before the droplets enter the collision-fee high vacuum region further downstream.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

Coherent Manipulation of Single Electrons with Optical Photons in Condensed Helium-4

Single electrons are one of the simplest quantum objects in nature. In free space or conventional materials, single electrons hardly interact with optical (ultraviolet-visible-infrared) photons, so their quantum states cannot be easily manipulated by optics. Here, a notable exception is is theoretically demonstrated: A single electron in condensed helium-4 can be self-confined in a nanometric bubble of 1 to 2 nm radius and resonantly interact with mid-infrared photons of 3 to 12 μm wavelength. A femtosecond laser can drive the electron into Rabi oscillations and prepare it onto arbitrary superposition states between the ground and excited states. After the laser pulse, the electron bubble can exhibit remarkable nonequilibrium quantum dynamics and evolve toward various final states with various lifetimes. These processes are accompanied with intense phonon radiation.

36 MATERIALS SCIENCE↗

Electronic rotons and Wigner crystallites in a two-dimensional dipole liquid

A key concept proposed by Landau to explain superfluid liquid helium is the elementary excitation of quantum particles called rotons1–8. The irregular arrangement of atoms in a liquid leads to the aperiodic dispersion of rotons, which played a pivotal role in understanding fractional quantum Hall liquids (magneto-rotons)9,10 and the supersolidity of Bose–Einstein condensates11–13. Even for a two-dimensional electron or dipole liquid, in the absence of a magnetic field, the repulsive interactions have been predicted to form a roton minimum14–19, which can be used to trace the transition to Wigner crystals20–24 and superconductivity25–27, although this has not yet been observed. Here, we report the observation of such electronic rotons in a two-dimensional dipole liquid of alkali-metal ions donating electrons to surface layers of black phosphorus. Our data reveal the striking aperiodic dispersion of rotons, which is characterized by a local minimum of energy at finite momentum. As the density of dipoles decreases so that interactions dominate over the kinetic energy, the roton gap reduces to 0, as in a crystal, signalling Wigner crystallization. Our model shows the importance of short-range order arising from repulsion between dipoles, which can be viewed as the formation of Wigner crystallites (bubbles or stripes) floating in the sea of a Fermi liquid. Our results reveal that the primary origin of electronic rotons (and the pseudogap) is strong correlations.

Park, Soobin↗

Transient heat transfer of superfluid He 4 in nonhomogeneous geometries: Second sound, rarefaction, and thermal layer

Transient heat transfer in superfluid 4 He (He II) is a complex process that involves the interplay of the unique counterflow heat-transfer mode, the emission of second-sound waves, and the creation of quantized vortices. Many past researches focused on homogeneous heat transfer of He II in a uniform channel driven by a planar heater. Here, we report our systematic study of He II transient heat transfer in nonhomogeneous geometries that are pertinent to emergent applications. By solving the He II two-fluid equations of motion coupled with Vinen's equation for vortex-line density, we examine and compare the characteristics of transient heat transfer from planar, cylindrical, and spherical heaters in He II. Our results show that as the heater turns on, an outgoing second-sound pulse emerges, within which the vortex-line density grows rapidly. These vortices attenuate the second sound and result in a heated He II layer in front of the heater, i.e., the thermal layer. In the planar case where the vortices are created throughout the space, the second-sound pulse is continuously attenuated, leading to a thick thermal layer that diffusely spreads following the heat pulse. On the contrary, in the cylindrical and the spherical heater cases, vortices are created mainly in a thin thermal layer near the heater surface. As the heat pulse ends, a rarefaction tail develops following the second-sound pulse, in which the temperature drops. This rarefaction tail can promptly suppress the thermal layer and take away the deposited thermal energy. The effects of the heater size, heat flux, pulse duration, and temperature on the thermal-layer dynamics are discussed. We also show how the peak heat flux for the onset of boiling in He II can be studied in our model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-voltage and electrode system for a cryogenic experiment to search for the neutron electric dipole moment

The cryogenic approach to the search for the neutron electric dipole moment—performing the experiment in superfluid liquid helium—holds promise for a substantial increase in sensitivity, potentially enabling a sensitivity level of 10 −28 𝑒cm. A crucial component in realizing such an experiment is the high-voltage and electrode system capable of providing an electric field of 75 kV/cm. This, in turn, requires an electric potential of 635 kV to be applied to the high-voltage electrode, while simultaneously satisfying other experimental constraints, such as those on heat load and magnetic noise requirements. In this work, we describe the outcome of a comprehensive development program addressing these challenges. It outlines the system requirements, discusses new insights into relevant physical phenomena, and details selected technical solutions with their corresponding experimental demonstrations and expected performance. The results collectively demonstrate the successful development of the necessary technology for the high-voltage and electrode system for this approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗