Search NASA⌕ Search

SEARCH · Search NASA

Results for “support vector machine (SVM)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Automatic detection of large pulmonary solid nodules in thoracic CT images

Purpose: Current computer-aided detection (CAD) systems for pulmonary nodules in computed tomography (CT) scans have a good performance for relatively small nodules, but often fail to detect the much rarer larger nodules, which are more likely to be cancerous. We present a novel CAD system specifically designed to detect solid nodules larger than 10 mm. Methods: The proposed detection pipeline is initiated by a three-dimensional lung segmentation algorithm optimized to include large nodules attached to the pleural wall via morphological processing. An additional preprocessing is used to mask out structures outside the pleural space to ensure that pleural and parenchymal nodules have a similar appearance. Next, nodule candidates are obtained via a multistage process of thresholding and morphological operations, to detect both larger and smaller candidates. After segmenting each candidate, a set of 24 features based on intensity, shape, blobness, and spatial context are computed. A radial basis support vector machine (SVM) classifier was used to classify nodule candidates, and performance was evaluated using ten-fold cross-validation on the full publicly available lung image database consortium database. Results: The proposed CAD system reaches a sensitivity of 98.3% (234/238) and 94.1% (224/238) large nodules at an average of 4.0 and 1.0 false positives/scan, respectively. Conclusions: The authors conclude that the proposed dedicated CAD system for large pulmonary nodules can identify the vast majority of highly suspicious lesions in thoracic CT scans with a small number of false positives.

60 APPLIED LIFE SCIENCES↗

SU-C-207B-06: Comparison of Registration Methods for Modeling Pathologic Response of Esophageal Cancer to Chemoradiation Therapy

Purpose: To compare linear and deformable registration methods for evaluation of tumor response to Chemoradiation therapy (CRT) in patients with esophageal cancer. Methods: Linear and multi-resolution BSpline deformable registration were performed on Pre-Post-CRT CT/PET images of 20 patients with esophageal cancer. For both registration methods, we registered CT using Mean Square Error (MSE) metric, however to register PET we used transformation obtained using Mutual Information (MI) from the same CT due to being multi-modality. Similarity of Warped-CT/PET was quantitatively evaluated using Normalized Mutual Information and plausibility of DF was assessed using inverse consistency Error. To evaluate tumor response four groups of tumor features were examined: (1) Conventional PET/CT e.g. SUV, diameter (2) Clinical parameters e.g. TNM stage, histology (3)spatial-temporal PET features that describe intensity, texture and geometry of tumor (4)all features combined. Dominant features were identified using 10-fold cross-validation and Support Vector Machine (SVM) was deployed for tumor response prediction while the accuracy was evaluated by ROC Area Under Curve (AUC). Results: Average and standard deviation of Normalized mutual information for deformable registration using MSE was 0.2±0.054 and for linear registration was 0.1±0.026, showing higher NMI for deformable registration. Likewise for MI metric, deformable registration had 0.13±0.035 comparing to linear counterpart with 0.12±0.037. Inverse consistency error for deformable registration for MSE metric was 4.65±2.49 and for linear was 1.32±2.3 showing smaller value for linear registration. The same conclusion was obtained for MI in terms of inverse consistency error. AUC for both linear and deformable registration was 1 showing no absolute difference in terms of response evaluation. Conclusion: Deformable registration showed better NMI comparing to linear registration, however inverse consistency of transformation was lower in linear registration. We do not expect to see significant difference when warping PET images using deformable or linear registration. This work was supported in part by the National Cancer Institute Grants R01CA172638.

60 APPLIED LIFE SCIENCES↗

TU-C-12A-09: Modeling Pathologic Response of Locally Advanced Esophageal Cancer to Chemo-Radiotherapy Using Quantitative PET/CT Features, Clinical Parameters and Demographics

Purpose: To develop predictive models using quantitative PET/CT features for the evaluation of tumor response to neoadjuvant chemo-radiotherapy (CRT) in patients with locally advanced esophageal cancer. Methods: This study included 20 patients who underwent tri-modality therapy (CRT + surgery) and had {sup 18}F-FDG PET/CT scans before initiation of CRT and 4-6 weeks after completion of CRT but prior to surgery. Four groups of tumor features were examined: (1) conventional PET/CT response measures (SUVmax, tumor diameter, etc.); (2) clinical parameters (TNM stage, histology, etc.) and demographics; (3) spatial-temporal PET features, which characterize tumor SUV intensity distribution, spatial patterns, geometry, and associated changes resulting from CRT; and (4) all features combined. An optimal feature set was identified with recursive feature selection and cross-validations. Support vector machine (SVM) and logistic regression (LR) models were constructed for prediction of pathologic tumor response to CRT, using cross-validations to avoid model over-fitting. Prediction accuracy was assessed via area under the receiver operating characteristic curve (AUC), and precision was evaluated via confidence intervals (CIs) of AUC. Results: When applied to the 4 groups of tumor features, the LR model achieved AUCs (95% CI) of 0.57 (0.10), 0.73 (0.07), 0.90 (0.06), and 0.90 (0.06). The SVM model achieved AUCs (95% CI) of 0.56 (0.07), 0.60 (0.06), 0.94 (0.02), and 1.00 (no misclassifications). Using spatial-temporal PET features combined with conventional PET/CT measures and clinical parameters, the SVM model achieved very high accuracy (AUC 1.00) and precision (no misclassifications), significantly better than using conventional PET/CT measures or clinical parameters and demographics alone. For groups with a large number of tumor features (groups 3 and 4), the SVM model achieved significantly higher accuracy than the LR model. Conclusion: The SVM model using all features including quantitative PET/CT features accurately and precisely predicted pathologic tumor response to CRT in esophageal cancer. This work was supported in part by National Cancer Institute Grant R21 CA131979 and R01 CA172638. Shan Tan was supported in part by the National Natural Science Foundation of China 60971112 and 61375018, and by Fundamental Research Funds for the Central Universities 2012QN086.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-J-02: Automatic Recognition of Patient Treatment Site in Portal Images Using Machine Learning

Purpose: To investigate the method to automatically recognize the treatment site in the X-Ray portal images. It could be useful to detect potential treatment errors, and to provide guidance to sequential tasks, e.g. automatically verify the patient daily setup. Methods: The portal images were exported from MOSAIQ as DICOM files, and were 1) processed with a threshold based intensity transformation algorithm to enhance contrast, and 2) where then down-sampled (from 1024×768 to 128×96) by using bi-cubic interpolation algorithm. An appearance-based vector space model (VSM) was used to rearrange the images into vectors. A principal component analysis (PCA) method was used to reduce the vector dimensions. A multi-class support vector machine (SVM), with radial basis function kernel, was used to build the treatment site recognition models. These models were then used to recognize the treatment sites in the portal image. Portal images of 120 patients were included in the study. The images were selected to cover six treatment sites: brain, head and neck, breast, lung, abdomen and pelvis. Each site had images of the twenty patients. Cross-validation experiments were performed to evaluate the performance. Results: MATLAB image processing Toolbox and scikit-learn (a machine learning library in python) were used to implement the proposed method. The average accuracies using the AP and RT images separately were 95% and 94% respectively. The average accuracy using AP and RT images together was 98%. Computation time was ∼0.16 seconds per patient with AP or RT image, ∼0.33 seconds per patient with both of AP and RT images. Conclusion: The proposed method of treatment site recognition is efficient and accurate. It is not sensitive to the differences of image intensity, size and positions of patients in the portal images. It could be useful for the patient safety assurance. The work was partially supported by a research grant from Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Advancing Artificial Intelligence with Liquid Argon Neutrino Experiments (Technical Report)

The grant allowed two main contributions: 1) The development of a first successful demonstration of the employment of Optimal Transport in liquid argon time projection chamber neutrino detectors. Optimal Transport, used in other contexts and specifically with LHC calorimetric data, was adapted to address a key particle identification challenge in LArTPCs: the separation of pi0 backgrounds from single-electrons produced in charged-current electron neutrino interactions. The work, leveraging ML methods such as k-nearest-neighbor (kNN) and support-vector-machine (SVM), showed an increase in background rejection of a factor of two or more. Work is now ongoing to incorporate this development in physics analyses for LArTPC experiments and more broadly expand the use of OT in LArTPC detectors including DUNE. This work was done in collaboration with the phenomenology group led by Nathaniel Craig at UCSB. 2) The deployment of NuGraph2, a graph neural network developed for LArTPC reconstruction, in the MicroBooNE experiment. NuGraph2 uses novel graph-neural-network methods on the rather simple LArTPC inputs of reconstructed hits, greatly simplifying the workflow compared to the use of waveform or signal-deconvolved wire ROIs. The network performed particle classification and was shown to address many challenging problems in LArTPC imaging including track-shower separation and the identification of protons and charged pions from primary muons. Our group collaborated with Giuseppe Cerati (FNAL scientist) who is one of the core developers of NuGraph2 to integrate this tool in MicroBooNE’s analysis framework. This consisted in tow key contributions: a) Studying performance on real data, which came with several months of iterations because the MC-trained version of the network was found to show significant bias that our group investigated and addressed. b) Integrating the output hit labeling of NuGraph2 into the existing particle tracking and shower reconstruction code. As a result of this work led by our team NuGraph2 is now enabling a suite of new analyses which benefit from enhanced capabilities and thus broader physics reach. The grant supported primarily the salary of UCSB graduate student Chuyue “Michaelia” Fang as well as partial summer salary support for PI Caratelli. Some funds were used for travel by Michaelia to ML related schools and conferences.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new classification scheme of plastic wastes based upon recycling labels

Highlights: • PET, HPDE or PP types of plastics are considered. • An automated classification of plastic bottles based on the feature extraction and classification methods is performed. • The decision mechanism consists of PCA, Kernel PCA, FLDA, SVD and Laplacian Eigenmaps methods. • SVM is selected to achieve the classification task and majority voting technique is used. - Abstract: Since recycling of materials is widely assumed to be environmentally and economically beneficial, reliable sorting and processing of waste packaging materials such as plastics is very important for recycling with high efficiency. An automated system that can quickly categorize these materials is certainly needed for obtaining maximum classification while maintaining high throughput. In this paper, first of all, the photographs of the plastic bottles have been taken and several preprocessing steps were carried out. The first preprocessing step is to extract the plastic area of a bottle from the background. Then, the morphological image operations are implemented. These operations are edge detection, noise removal, hole removing, image enhancement, and image segmentation. These morphological operations can be generally defined in terms of the combinations of erosion and dilation. The effect of bottle color as well as label are eliminated using these operations. Secondly, the pixel-wise intensity values of the plastic bottle images have been used together with the most popular subspace and statistical feature extraction methods to construct the feature vectors in this study. Only three types of plastics are considered due to higher existence ratio of them than the other plastic types in the world. The decision mechanism consists of five different feature extraction methods including as Principal Component Analysis (PCA), Kernel PCA (KPCA), Fisher’s Linear Discriminant Analysis (FLDA), Singular Value Decomposition (SVD) and Laplacian Eigenmaps (LEMAP) and uses a simple experimental setup with a camera and homogenous backlighting. Due to the giving global solution for a classification problem, Support Vector Machine (SVM) is selected to achieve the classification task and majority voting technique is used as the decision mechanism. This technique equally weights each classification result and assigns the given plastic object to the class that the most classification results agree on. The proposed classification scheme provides high accuracy rate, and also it is able to run in real-time applications. It can automatically classify the plastic bottle types with approximately 90% recognition accuracy. Besides this, the proposed methodology yields approximately 96% classification rate for the separation of PET or non-PET plastic types. It also gives 92% accuracy for the categorization of non-PET plastic types into HPDE or PP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Unraveling the Correlation between Raman and Photoluminescence in Monolayer MoS 2 through Machine‐Learning Models

Abstract 2D transition metal dichalcogenides (TMDCs) with intense and tunable photoluminescence (PL) have opened up new opportunities for optoelectronic and photonic applications such as light‐emitting diodes, photodetectors, and single‐photon emitters. Among the standard characterization tools for 2D materials, Raman spectroscopy stands out as a fast and non‐destructive technique capable of probing material's crystallinity and perturbations such as doping and strain. However, a comprehensive understanding of the correlation between photoluminescence and Raman spectra in monolayer MoS 2 remains elusive due to its highly nonlinear nature. Here, the connections between PL signatures and Raman modes are systematically explored, providing comprehensive insights into the physical mechanisms correlating PL and Raman features. This study's analysis further disentangles the strain and doping contributions from the Raman spectra through machine‐learning models. First, a dense convolutional network (DenseNet) to predict PL maps by spatial Raman maps is deployed. Moreover, a gradient boosted trees model (XGBoost) with Shapley additive explanation (SHAP) to bridge the impact of individual Raman features in PL features is applied. Last, a support vector machine (SVM) to project PL features on Raman frequencies is adopted. This work may serve as a methodology for applying machine learning to characterizations of 2D materials.

Lu, Ang‐Yu↗

Pyrrole‐Imine Macrocycle: Self‐Organizing Cross‐Reactive Anion Receptor and Sensor

Self-organizing macrocyclic receptor-sensors for phosphorus oxyanions, phosphates, and phosphonates comprising imine moieties were prepared by condensation of dipyrrolylmethane dicarbaldehyde with diethylene triamine. The incorporation of flexible ethylene moieties endows the macrocycle with unprecedented flexibility and ability to accommodate numerous phosphorus oxyanions from orthophosphate to large anions such as ATP or phosphonate glyphosate. The anion binding was elucidated by NMR titrations, low-temperature NMR, and NOESY NMR. The incorporation of dansyl fluorophore enables sensing of anions using the fluorescence signal, whereas the changes in fluorescence intensity, width of the fluorescence band, and position of the maxima are analyte-specific and useful in recognition and identification of eleven different P-oxyanions in water. The affinity (K assoc ) for Na + salts was H 2 PO 4 − ≈ Methylphosphonate > H 2 P 2 O 7 2− > Phenylphosphonate- > Glyphosate 2− > AMP 2− > ADP 2− > ATP 2− . Interestingly, phosphonates, including methylphosphonate and glyphosate anions, were also found to display a strong affinity (K assoc ∼10 6 M −1 ) while halides, nitrate, carbonates, or hydrogen sulfate did not show a significant affinity. The determined fluorescence spectral parameters were used to classify the 12 analytes (11 anions and water) using Linear Discriminant Analysis (LDA). Quantification was performed using LDA and Support Vector Machine (SVM), and the phosphonate concentrations in unknown samples were determined with an error of 3.5% or lower.

anions↗

Automatic detection of small bowel tumors in wireless capsule endoscopy images using ensemble learning

Purpose Wireless Capsule Endoscopy (WCE) is a minimally invasive diagnosis tool for lesion detection in the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the significant amount of acquired data leads to difficulties in the diagnosis by the physicians; which can be eased with computer assistance. This paper addresses a method for the automatic detection of tumors in WCE by using a two‐step based procedure: region of interest selection and classification. Methods The first step aims to separate abnormal from normal tissue by using automatic segmentation based on a Gaussian Mixture Model (GMM). A modified version of the Anderson method for convergence acceleration of the expectation–maximization (EM) algorithm is proposed. The proposed features for both segmentation and classification are based on the CIELab color space, as a way of bypassing lightness variations, where the L component is discarded. Tissue variability among subjects, light inhomogeneities and even intensity differences among different devices can be overcome by using simultaneously features from both regions. In the second step, an ensemble system with partition of the training data with a new training scheme is proposed. At this stage, the gating network is trained after the experts have been trained decoupling the joint maximization of both modules. The partition module is also used at the test step, leading the incoming data to the most likely expert allowing incremental adaptation by preserving data diversity. Results This algorithm outperforms others based on texture features selected from Wavelets and Curvelets transforms, classified by a regular support vector machine (SVM) in more than 5%. Conclusions This work shows that simpler features can outperform more elaborate ones if appropriately designed. In the current case, luminance was discarded to cope with saturated tissue, facilitating the color perception. Ensemble systems remain an open research field. In the current case, changes in both topology and training strategy have led to significant performance improvements. A system with this level of performance can be used in current clinical practice.

Vieira, Pedro M.↗

Risk assessment of engineering diseases of embankment–bridge transition section for railway in permafrost regions

Abstract The embankment–bridge transition section (EBTS) is one of the zones where railway diseases occur frequently in permafrost regions. Disease risk assessment of EBTSs can provide guidance for maintenance. In this study, considering the engineering geological conditions, climate characteristics, and embankment structure types along the Qinghai–Tibet Railway (QTR) as well as based on the disease inventory of the QTR from 2010 to 2019, the logistic regression (LR), support vector machine (SVM), and combination‐weight‐based gay relation analysis (GRA) were used for disease risk assessment of the EBTSs along the QTR in permafrost regions. The results indicate that the LR and SVM models have a better capability for EBTS disease prediction than the GRA model, and the SVM model can select more disease samples in relatively larger regions than the LR model. Based on the SVM and LR models, the risk level of EBTSs is divided into four classes: low‐ (29.9%), moderate‐ (39.6%), high‐ (22.1%), and very high (8.4%) risk. Finally, we selected 272 EBTSs in high‐ and very‐high‐risk classes for key observation during the maintenance of the QTR in permafrost regions. This study provides a reference for the risk assessment of railways built in permafrost regions using data‐driven methods.

Zhang, Saize↗

Predicting Search Task Difficulty through a Discrete‐Time Action Log Representation on Spectrum Kernel

ABSTRACT Predicting perceived difficulty on a web search task is an open problem in the interactive information retrieval field. A common approach to tackle it, is through features obtained from full search sessions, which are then used to train classification models. In this poster we attempt to predict perceived task difficulty at different stages of the search process. To do so, we use the spectrum kernel for support vector machine (SVM) classification. Our preliminary results suggest that by using behavioral data from the first query segment, it is possible to provide timely classifications of whether a search task is perceived as hard or easy.

Gacitúa, Daniel↗

Performance of a machine learning-based decision model to help clinicians decide the extent of lymphadenectomy (D1 vs. D2) in gastric cancer before surgical resection

Background: Controversy still exists on the optimal surgical resection for potentially curable gastric cancer (GC). Use of radiologic evaluation and machine learning algorithms might predict extent of lymphadenectomy to limit unnecessary surgical treatment. We purposed to design a machine learning-based clinical decision-support model for predicting extent of lymphadenectomy (D1 vs. D2) in local advanced GC. Methods: Clinicoradiologic features available from routine clinical assignments in 557 patients with GCs were retrospectively interpreted by an expert panel blinded to all histopathologic information. All patients underwent surgery using standard D2 resection. Decision models were developed with a logistic regression (LR), support vector machine (SVM) and auto-encoder (AE) algorithm in 371 training and tested in 186 test data, respectively. The primary end point was to measure diagnostic performance of decision model and a Japanese gastric cancer treatment guideline version 4th (JPN 4th) criteria for discriminate D1 (pT1 + pN0) versus D2 (≥ pT1 + ≥ pN1) lymphadenectomy. Results: The decision model with AE analysis produced highest area under ROC curve (train: 0.965, 95% confidence interval (CI) 0.948–0.978; test: 0.946, 95% CI 0.925–0.978), followed by SVM (train: 0.925, 95% CI 0.902–0.944; test: 0.942, 95% CI 0.922–0.973) and LR (train: 0.886, 95% CI 0.858–0.910; test: 0.891, 95% CI 0.891–0.952). By this improvement, overtreatment was reduced from 21.7% (121/557) by treat-all pattern, to 15.1% (84/557) by JPN 4th criteria, and to 0.7–0.9% (4–5/557) by the new approach. Conclusions: The decision model with machine learning analysis demonstrates high accuracy for identifying patients who are candidates for D1 versus D2 resection. Its approximate 14–20% improvements in overtreatment compared to treat-all pattern and JPN 4th criteria potentially increase the number of patients with local advanced GCs who can safely avoid unnecessary lymphadenectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrating Natural Language Processing and Machine Learning Algorithms to Categorize Oncologic Response in Radiology Reports

A significant volume of medical data remains unstructured. Natural language processing (NLP) and machine learning (ML) techniques have shown to successfully extract insights from radiology reports. However, the codependent effects of NLP and ML in this context have not been well-studied. Between April 1, 2015 and November 1, 2016, 9418 cross-sectional abdomen/pelvis CT and MR examinations containing our internal structured reporting element for cancer were separated into four categories: Progression, Stable Disease, Improvement, or No Cancer. We combined each of three NLP techniques with five ML algorithms to predict the assigned label using the unstructured report text and compared the performance of each combination. The three NLP algorithms included term frequency-inverse document frequency (TF-IDF), term frequency weighting (TF), and 16-bit feature hashing. The ML algorithms included logistic regression (LR), random decision forest (RDF), one-vs-all support vector machine (SVM), one-vs-all Bayes point machine (BPM), and fully connected neural network (NN). The best-performing NLP model consisted of tokenized unigrams and bigrams with TF-IDF. Increasing N-gram length yielded little to no added benefit for most ML algorithms. With all parameters optimized, SVM had the best performance on the test dataset, with 90.6 average accuracy and F score of 0.813. The interplay between ML and NLP algorithms and their effect on interpretation accuracy is complex. The best accuracy is achieved when both algorithms are optimized concurrently.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Shallow and Deep Learning Methods on Classifying the Regional Pattern of Diffuse Lung Disease

This study aimed to compare shallow and deep learning of classifying the patterns of interstitial lung diseases (ILDs). Using high-resolution computed tomography images, two experienced radiologists marked 1200 regions of interest (ROIs), in which 600 ROIs were each acquired using a GE or Siemens scanner and each group of 600 ROIs consisted of 100 ROIs for subregions that included normal and five regional pulmonary disease patterns (ground-glass opacity, consolidation, reticular opacity, emphysema, and honeycombing). We employed the convolution neural network (CNN) with six learnable layers that consisted of four convolution layers and two fully connected layers. The classification results were compared with the results classified by a shallow learning of a support vector machine (SVM). The CNN classifier showed significantly better performance for accuracy compared with that of the SVM classifier by 6–9%. As the convolution layer increases, the classification accuracy of the CNN showed better performance from 81.27 to 95.12%. Especially in the cases showing pathological ambiguity such as between normal and emphysema cases or between honeycombing and reticular opacity cases, the increment of the convolution layer greatly drops the misclassification rate between each case. Conclusively, the CNN classifier showed significantly greater accuracy than the SVM classifier, and the results implied structural characteristics that are inherent to the specific ILD patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Segmentation and Quantification of Drusen in Fundus and Optical Coherence Tomography Images for Detection of ARMD

Age-related macular degeneration (ARMD) is one of the most common retinal syndromes that occurs in elderly people. Different eye testing techniques such as fundus photography and optical coherence tomography (OCT) are used to clinically examine the ARMD-affected patients. Many researchers have worked on detecting ARMD from fundus images, few of them also worked on detecting ARMD from OCT images. However, there are only few systems that establish the correspondence between fundus and OCT images to give an accurate prediction of ARMD pathology. In this paper, we present fully automated decision support system that can automatically detect ARMD by establishing correspondence between OCT and fundus imagery. The proposed system also distinguishes between early, suspect and confirmed ARMD by correlating OCT B-scans with respective region of the fundus image. In first phase, proposed system uses different B-scan based features along with support vector machine (SVM) to detect the presence of drusens and classify it as ARMD or normal case. In case input OCT scan is classified as ARMD, region of interest from corresponding fundus image is considered for further evaluation. The analysis of fundus image is performed using contrast enhancement and adaptive thresholding to detect possible drusens from fundus image and proposed system finally classified it as early stage ARMD or advance stage ARMD. The proposed system is tested on local data set of 100 patients with100 fundus images and 6800 OCT B-scans. Proposed system detects ARMD with the accuracy, sensitivity, and specificity ratings of 98.0, 100, and 97.14%, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Can Laws Be a Potential PET Image Texture Analysis Approach for Evaluation of Tumor Heterogeneity and Histopathological Characteristics in NSCLC?

We investigated the association between the textural features obtained from {sup 18}F-FDG images, metabolic parameters (SUVmax{sub ,} SUVmean, MTV, TLG), and tumor histopathological characteristics (stage and Ki-67 proliferation index) in non-small cell lung cancer (NSCLC). The FDG-PET images of 67 patients with NSCLC were evaluated. MATLAB technical computing language was employed in the extraction of 137 features by using first order statistics (FOS), gray-level co-occurrence matrix (GLCM), gray-level run length matrix (GLRLM), and Laws’ texture filters. Textural features and metabolic parameters were statistically analyzed in terms of good discrimination power between tumor stages, and selected features/parameters were used in the automatic classification by k-nearest neighbors (k-NN) and support vector machines (SVM). We showed that one textural feature (gray-level nonuniformity, GLN) obtained using GLRLM approach and nine textural features using Laws’ approach were successful in discriminating all tumor stages, unlike metabolic parameters. There were significant correlations between Ki-67 index and some of the textural features computed using Laws’ method (r = 0.6, p = 0.013). In terms of automatic classification of tumor stage, the accuracy was approximately 84% with k-NN classifier (k = 3) and SVM, using selected five features. Texture analysis of FDG-PET images has a potential to be an objective tool to assess tumor histopathological characteristics. The textural features obtained using Laws’ approach could be useful in the discrimination of tumor stage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Organ Segmentation for CT Scans Based on Super-Pixel and Convolutional Neural Networks

Accurate segmentation of specific organ from computed tomography (CT) scans is a basic and crucial task for accurate diagnosis and treatment. To avoid time-consuming manual optimization and to help physicians distinguish diseases, an automatic organ segmentation framework is presented. The framework utilized convolution neural networks (CNN) to classify pixels. To reduce the redundant inputs, the simple linear iterative clustering (SLIC) of super-pixels and the support vector machine (SVM) classifier are introduced. To establish the perfect boundary of organs in one-pixel-level, the pixels need to be classified step-by-step. First, the SLIC is used to cut an image into grids and extract respective digital signatures. Next, the signature is classified by the SVM, and the rough edges are acquired. Finally, a precise boundary is obtained by the CNN, which is based on patches around each pixel-point. The framework is applied to abdominal CT scans of livers and high-resolution computed tomography (HRCT) scans of lungs. The experimental CT scans are derived from two public datasets (Sliver 07 and a Chinese local dataset). Experimental results show that the proposed method can precisely and efficiently detect the organs. This method consumes 38 s/slice for liver segmentation. The Dice coefficient of the liver segmentation results reaches to 97.43%. For lung segmentation, the Dice coefficient is 97.93%. This finding demonstrates that the proposed framework is a favorable method for lung segmentation of HRCT scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure prediction using machine learning in a virtualised HPC system and application

Failure is an increasingly important issue in high performance computing and cloud systems. As large-scale systems continue to grow in scale and complexity, mitigating the impact of failure and providing accurate predictions with sufficient lead time remains a challenging research problem. Traditional existing fault-tolerance strategies such as regular check-pointing and replication are not adequate because of the emerging complexities of high performance computing systems. This necessitates the importance of having an effective as well as proactive failure management approach in place aimed at minimizing the effect of failure within the system. With the advent of machine learning techniques, the ability to learn from past information to predict future pattern of behaviours makes it possible to predict potential system failure more accurately. Thus, in this paper, we explore the predictive abilities of machine learning by applying a number of algorithms to improve the accuracy of failure prediction. We have developed a failure prediction model using time series and machine learning, and performed comparison based tests on the prediction accuracy. The primary algorithms we considered are the support vector machine (SVM), random forest (RF), k-nearest neighbors (KNN), classification and regression trees (CART) and linear discriminant analysis (LDA). Experimental results indicates that the average prediction accuracy of our model using SVM when predicting failure is 90% accurate and effective compared to other algorithms. This finding implies that our method can effectively predict all possible future system and application failures within the system.

Mohammed, Bashir↗