Search NASA⌕ Search

SEARCH · Search NASA

Results for “sweat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A liquid cooled garment temperature controller based on sweat rate

An automatic controller for liquid cooled space suits is reported that utilizes human sweat rate as the primary input signal. The controller is so designed that the coolant inlet temperature is inversely proportional to the subject's latent heat loss as evidenced by evaporative water loss.

Chambers, A. B.↗

Control of skin blood flow, sweating, and heart rate - Role of skin vs. core temperature

A study was conducted to generate quantitative expressions for the influence of core temperature, skin temperature, and the rate of change of skin temperature on sweat rate, skin blood flow, and heart rate. A second goal of the study was to determine whether the use of esophageal temperature rather than the right atrial temperature as a measure of core temperature would lead to different conclusions about the control of measured effector variables.

Wyss, C. R.↗

Effect of local cooling on sweating rate and cold sensation

Subjects resting in a 39 C environment were stimulated in different skin regions with a water-cooled thermode. Results indicate that cooling different body regions produces generally equivalent decreases in sweating rate and increases in cold sensation, with the forehead showing a much greater sensitivity per unit area and temperature decrease than other areas. The high thermal sensitivity of the face may have evolved when it was the thinnest-furred area of the body; today's clothing habits have reestablished the importance of the face in the regulation of body temperature.

Crawshaw, L. I.↗

Use of dew-point detection for quantitative measurement of sweating rate

A method of measuring sweat rate (SR) based on detection of dew point (DP) is proposed which has advantages that may be attractive to other laboratories concerned with recording SR from selected areas of skin. It is similar to other methods in that dry gas is passed through a capsule which isolates several square centimeters of skin surface. The difference is in the means of determining how much gaseous water is carried off in the effluent moist gas. The DP detector used is free of the drawbacks of previous devices. DP is obtained through the fundamental technique of determining the temperature at which condensate forms on a mirror. Variations in DP are tracked rapidly, and accurately (+ or - 0.8 C nominal, sensitivity + or - 0.05 C) over a wide range ( -40 C to +50 C) without measurable hysteresis. The detector asembly is rugged and readily opened for cleaning and inspection.

Brengelmann, G. L.↗

Devices Would Detect Drugs In Sweat

Proposed devices worn on skin detect such substances as methamphetamine, morphine, tetrahydrocannabinol (THC), and cocaine in wearers' sweat and transmits radio signals in response to computer queries. Called Remote Biochemical Assay Telemetering System (R-BATS), commonly referred to as "drug badge," attached to wearer by use of adhesive wristband. Used for noninvasive monitoring of levels of prescribed medications in hospital and home-care settings and to detect overdoses quickly.

Mintz, Fredrick W.↗

A device for determining the intensity of partial sweating

An invention which can measure partial perspiration is disclosed. The partial perspiration is measured with a specially shaped device tightly fastened to the body but not touching the skin area being studied. A special grid is used to keep the moisture-absorbing agent from touching the skin.

Rayskiy, V. A.↗

Phase II Testing of Liquid Cooling Garments Using a Sweating Manikin, Controlled by a Human Physiological Model

An Advanced Automotive Manikin (ADAM) developed at the National Renewable Energy Laboratory (NREL) is used to evaluate NASA's liquid cooling garments (LCGs) used in advanced space suits for extravehicular applications. The manikin has 120 separate heated/sweating zones and is controlled by a finite element physiological model of the human thermoregulatory system. Previous testing showed the thermal sensation and comfort followed the expected trends as the LCG inlet fluid temperature was changed. The Phase II test data demonstrates the repeatability of ADAM by retesting the baseline LCG. Skin and core temperature predictions using ADAM in an LCG/Arctic suit combination are compared to NASA physiological data to validate the manikin/model. Additional LCG configurations are assessed using the manikin and compared to the baseline LCG. Results can extend to other personal protective clothing, including HAZMAT suits, nuclear/biological/chemical protective suits, and fire protection suits.

Paul, Heather↗

Sweating the Small Stuff: A Sensor for Real-Time Neuro-Immune Axis Monitoring

Although manageable with certain precautions, circadian rhythm misalignment and sleep disturbances pose a potential threat to astronaut health. It is well-known that sleep is essential for proper immunological and neurological functioning, while impairments in these functions result in risks for spaceflight success. Neuropeptides and hormones are involved in regulating the circadian clock and are used as biomarkers for circadian alignment. However, in-flight monitoring of these biomarkers is limited due to the lack of real-time sensor systems and sample collection/processing confines. Therefore, real-time measurements of biomarkers in-flight are necessary for mission success and crew health. For this, a robust biomarker involved in the neuro-immune axis of circadian rhythm cycling, physiological stress responses, and inflammation would be well-received as a viable biomarker for assessing physiological health for crew during long-duration missions, as these are currently NASA Human Research Program defined risks. Therefore, this paper describes the development of a wearables we at biosensor to measure the biological clock neuropeptide, orexin/hypocretin. Additionally, potential for implementation of a user-friendly sensor of orexin/hypocretin to be telemetrically reported in real-time, is proposed. In brief, the proposed system has the possibility to be used as a biomarker monitor to support preventive and personalized medicine.

Amber M Paul↗

Research Operations and Integration Flight Session – Always Sweat the Small Stuff

Human research routinely involves elaborate operations with substantial hardware setup, such as functional MRIs, CT scans, ultrasounds, exercise sessions, and cardiac evaluations. These conspicuous operations garner most of our attention and, understandably, resources, but the unsung heroes of spaceflight human research often get by with little fanfare. The collection of human samples and surveys is often just as much of a challenge in terms of both planning and logistics. The samples and surveys are often collected or completed by the crew autonomously, with little to no oversight from science support staff, which puts them the most at risk for data loss. The Research Operations and Integration team will host an interactive session with audience participation to demonstrate the importance of the written communications and instructions that are provided to the astronauts. During this hands-on session, ROI will walk through the challenges faced to ensure astronaut subjects can successfully collect all the various samples (e.g., saliva, fecal, urine, and blood) that the human research community needs. The format will be part lecture and part game show intended to provide both an enlightening and fun session. As we often instruct the crew: “Don’t forget to arrive fasted and bring a list of all the medications you’ve taken in the past week.”

Cherie Morgan Oubre↗

Mechanisms of thermal acclimation to exercise and heat

By plotting local sweating rate from a given area against the central sweating drive (which is analogous to esophageal temperature, when mean skin temperature is constant), it is possible to determine the characteristic gain constant of that area as well as its point of zero central drive. An increase in the gain constant as a result of acclimation would indicate an increased sensitivity of the sweating mechanism per unit of central sweating drive, i.e., enhanced peripheral sensitivity. A displacement of the point of zero central drive as a result of acclimation would indicate that central mechanisms are responsible for the heightened sweating response. The study was undertaken to provide information about whether central or peripheral physiological mechanisms provide for increased sweating capabilities during acclimation, and about whether the increased sweating capabilities in heat acclimation and physical training are provided for by the same mechanisms.

Nadel, E. R.↗

Objective evaluation of cutaneous thermal sensivity

The possibility of obtaining reliable and objective quantitative responses was investigated under conditions where only temperature changes in localized cutaneous areas evoked measurable changes in remote sudomotor activity. Both male and female subjects were studied to evaluate sex difference in thermal sensitivity. The results discussed include: sweat rate responses to contralateral cooling, comparison of sweat rate responses between men and women to contralateral cooling, influence of the menstrual cycle on the sweat rate responses to contralateral cooling, comparison of threshold of sweating responses between men and women, and correlation of latency to threshold for whole body sweating. It is concluded that the quantitative aspects of the reflex response is affected by both the density and activation of receptors as well as the rate of heat loss; men responded 8-10% more frequently than women to thermode cooling, the magnitude of responses being greater for men; and women responded 7-9% more frequently to thermode cooling on day 1 of menstruation, as compared to day 15.

Vanbeaumont, W.↗

Analysis of evaporative water loss in the Skylab astronauts

Daily evaporative water losses (EWL) during the three Skylab missions were measured using the indirect mass and water balance techniques. A mean inflight EWL of 860 ml/day-m 2 was obtained for nine men who averaged one hour of daily exercise. Although it was expected the EWL would increase in the hypobaric environment of Skylab (1/3 atmosphere), an average decrease from preflight sea level conditions of 11 percent was measured. The results suggest that weightlessness may have been a factor in modifying EWL primarily by decreasing sweat losses during exercise and possibly by reducing insensible skin losses as well. The weightless environment apparently promotes the formation of a sweat film on the skin surface both directly, by reducing heat and mass convective flow and sweat drippage, and perhaps indirectly by inducing measurable biochemical changes resulting in high initial sweating rates. It is proposed that these high levels of skin wettedness favor sweat suppression by a previously described mechanism.

Leonard, J. I.↗

An Investigation into the Effect of Liquid Accumulation on Thermo-Physiologic State using an Advanced Moisture Model Coupled with a High Resolution Human Thermal Model

A physics-based mathematical model for simulating heat and moisture transport on the skin and within clothing was developed to improve the accuracy of human thermal modeling predictions. In a previous study, a set of sweating hotplate experiments was specifically created to obtain test data for model validation. The clothing moisture model was subsequently coupled with a human thermal model and tested by simulating human experiments described in the open literature, which served to verify the model’s ability to predict whole body thermo-physiologic state in work-rest cycles during which sweating was known to occur. In this study, a human subject test was specifically designed to validate the model’s ability to predict local and whole body sweat evaporation and accumulation on the surface of the body. The human subject test incorporated twelve clothed male subjects of moderate physical fitness, ages 18-30, which were prescribed a work-rest cycle in a climate-controlled chamber (25 °C, 50% RH). Two activity levels were considered during the active stage (4 MET vs. 6.5 MET), and two sets of ending ambient conditions were considered for the final rest stage (25 °C vs. 15 °C, 50% RH). Model predictions were compared to the measured local skin temperatures, core temperatures, and whole body sweat losses. In general, the model was able to reproduce the trends observed in the human subject trial, but more importantly, provided insight into how dynamic changes in liquid content can impact the evolution of local and whole body thermo-physiologic state. This study demonstrates the ability of an advanced moisture model to capture distinct physics attributable to moisture accumulation, allowing for increased accuracy in predicting human thermal state and for interpreting the results of measurements derived from human subject tests.

human thermal model↗

Evaporative water loss in man in a gravity-free environment

Daily evaporative water losses (EWL) during the three Skylab missions were measured indirectly using mass and water-balance techniques. The mean daily values of EWL for the nine crew members who averaged 1 hr of daily exercise were: preflight 1,750 + or - 37 (SE) ml or 970 + or - 20 ml/sq m and inflight 1,560 + or - 26 ml or 860 + or - 14 ml/sq m. Although it was expected the EWL would increase in the hypobaric environment of Skylab, an average decrease from preflight sea-level conditions of 11% was measured. The results suggest that weightlessness decreased sweat losses during exercise and possibly reduced insensible skin losses. The weightlessness environment apparently promotes the formation of an observed sweat film on the skin surface during exercise by reducing convective flow and sweat drippage, resulting in high levels of skin wettedness that favor sweat suppression.

Leach, C. S.↗