Search NASA⌕ Search

SEARCH · Search NASA

Results for “system characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Biological System Characterization to Address Biofouling of the 200 West Pump-and-Treat Injection Wells

Contaminated groundwater in the 200W Area of the Hanford Site is being treated ex situ by the 200W Pump-and-Treat (P&T) Facility and the subsurface plume is under hydraulic containment. The 200W P&T Facility removes several contaminants of concern from groundwater, as well as nitrate. Facility capacity is constrained by biofouling of injection wells, which limits the ability to efficiently inject treated effluent water in to the subsurface. In a previous report, Thomle et al. provided a comprehensive engineering assessment of biofouling at the 200W P&T Facility. In that report, both operational changes and facility modifications were recommended to help mitigate the symptoms and consequences of biofouling by expanding treatment processes in the plant. The 200W P&T Facility’s fluidized bed reactor (FBR) is a biological treatment system that has been identified as a principal source of biofouling. Carbon and nutrient inputs to the FBR are needed to sustain high rates of activity, but can also be responsible for microbial proliferation in the effluent water distribution pipeline, and loss injection well capacity. The primary objective of this work was to fill critical knowledge gaps associated with the FBR that can be used to optimize the biological system for continuous operation and sustained performance.

54 ENVIRONMENTAL SCIENCES↗

Pore system characterization of organic-rich shales using nanoscale-resolution 3D imaging

The Vaca Muerta Shale in Argentina is the first signifcant commercial shale oil/gas play outside of North America. High-resolution 2D/3D imaging of shale rocks for the purpose of establishing their mineralogy, total, and connected porosities has become more and more sophisticated. In this paper, nanoscale-resolution focused ion beam (FIB)-scanning electron microscopy (SEM) nano-tomography was used to obtain images of pore structures within two organic-rich regions of interest (ROIs), selected based on correlative SEM and automated mineralogy maps. Advanced machine learning classification tools were used to segment the images and assign porosities and other components. Pore size distribution and pore connectivity analyzes revealed that about 95% of all the pores, present within the two ROIs, had a diameter of less than approximately 75 nm, and that most of these pores were poorly connected. In a similar fashion, the flow rate distribution analysis showed that pores with diameters of about 150-330 nm contributed to over 50% of the flow capacity of the connected pore systems. These results suggest that although most of the pores typically found in shales have pore diameter smaller than about 100 nm, most of the hydrocarbon production may be carried by a relatively small number of larger connected pores with pore diameter greater than about 150 nm. This research implies that a large portion of the organic-hosted pores (with diameter typically smaller than about 100 nm) may not provide permeable flow pathways for the oil and/or gas migration, and hence may have very little contribution to the hydrocarbon production.

58 GEOSCIENCES↗

Phase lag deduced information in photo-thermal actuation for nano-mechanical systems characterization

In photo-thermal actuation, heat is added locally to a micro-cantilever by means of a laser. A fraction of the irradiation is absorbed, yielding thermal stresses and deformations in the structure. Harmonic modulation of the laser power causes the cantilever to oscillate. Moreover, a phase lag is introduced which is very sensitive to the spot location and the cantilever properties. This phase lag is theoretically predicted and experimentally verified. Combined with thermo-mechanical properties of the cantilever and its geometry, the location of the laser spot, the thermal diffusivity, and the layer thicknesses of the cantilever can be extracted.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Load-cell based characterization system for a “Violin-Mode” shadow-sensor in advanced LIGO suspensions

The background to this work was a prototype shadow sensor, which was designed for retro-fitting to an advanced LIGO (Laser Interferometer Gravitational wave Observatory) test-mass/mirror suspension, in which 40 kg test-mass/mirrors are each suspended by four approximately 600 mm long by 0.4 mm diameter fused-silica suspension fibres. The shadow sensor comprised a LED source of Near InfraRed (NIR) radiation and a rectangular silicon photodiode detector, which, together, were to bracket the fibre under test. The aim was to detect transverse Violin-Mode resonances in the suspension fibres. Part of the testing procedure involved tensioning a silica fibre sample and translating it transversely through the illuminating NIR beam, so as to measure the DC responsivity of the detection system to fibre displacement. However, an equally important part of the procedure, reported here, was to keep the fibre under test stationary within the beam, whilst trying to detect low-level AC Violin-Mode resonances excited on the fibre, in order to confirm the primary function of the sensor. Therefore, a tensioning system, incorporating a load-cell readout, was built into the test fibre’s holder. The fibre then was excited by a signal generator, audio power amplifier, and distant loudspeaker, and clear resonances were detected. A theory for the expected fundamental resonant frequency as a function of fibre tension was developed and is reported here, and this theory was found to match closely with the detected resonant frequencies as they varied with tension. Consequently, the resonances seen were identified as being proper Violin-Mode fundamental resonances of the fibre, and the operation of the Violin-Mode detection system was validated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light- and Elevated-Temperature-Induced Degradation-Affected Silicon Cells From a Utility-Scale Photovoltaic System Characterized by Deep-Level Transient Spectroscopy

Photovoltaic modules from a utility-scale field experienced power loss by light- and elevated-temperature-induced degradation (LeTID). Samples from the affected monocrystalline silicon cells are cored and extracted from the module packaging and then laser-scribed to form 2-mm diameter isolated areas. Using deep-level transient spectroscopy, a majority-carrier, hole-trap defect with an activation energy of 0.42 eV is detected on degraded and regenerated samples. The LeTID-degraded sample, however, has a larger signal corresponding to a trap density of 1.1 x 10 13 cm -3 , which is about five times larger than the 2.1 x 10 12 cm -3 trap density of the regenerated sample. An increase in filling pulse time from 50 u s to 20 ms shows a slight decrease in activation energy from 0.42 to 0.36 eV suggesting that the defect level may consist of a band of energy states where shallower states continue to fill with long filling times. The capture rate of the defect is directly measured using an increasing series of filling pulsewidths in 15 to 125 ns range. This leads to a measured capture cross section of 5.1 x 10 -17 cm 2 , and using an approximate defect density of 10 13 cm -3 , the majority-carrier-hole lifetime related to this defect is approximately 100 u s when in the LeTID-degraded state.

charge carrier lifetime↗

Space station integrated wall damage and penetration damage control. Task 5: Space debris measurement, mapping and characterization system

The procedures and results of a study of a conceptual system for measuring the debris environment on the space station is discussed. The study was conducted in two phases: the first consisted of experiments aimed at evaluating location of impact through panel response data collected from acoustic emission sensors; the second analyzed the available statistical description of the environment to determine the probability of the measurement system producing useful data, and analyzed the results of the previous tests to evaluate the accuracy of location and the feasibility of extracting impactor characteristics from the panel response. The conclusions were that for one panel the system would not be exposed to any event, but that the entire Logistics Module would provide a modest amount of data. The use of sensors with higher sensitivity than those used in the tests could be advantageous. The impact location could be found with sufficient accuracy from panel response data. The waveforms of the response were shown to contain information on the impact characteristics, but the data set did not span a sufficient range of the variables necessary to evaluate the feasibility of extracting the information.

Lempriere, B. M.↗

Systems Characterization of Combustor Instabilities With Controls Design Emphasis

This effort performed test data analysis in order to characterize the general behavior of combustor instabilities with emphasis on controls design. The analysis is performed on data obtained from two configurations of a laboratory combustor rig and from a developmental aero-engine combustor. The study has characterized several dynamic behaviors associated with combustor instabilities. These are: frequency and phase randomness, amplitude modulations, net random phase walks, random noise, exponential growth and intra-harmonic couplings. Finally, the very cause of combustor instabilities was explored and it could be attributed to a more general source-load type impedance interaction that includes the thermo-acoustic coupling. Performing these characterizations on different combustors allows for more accurate identification of the cause of these phenomena and their effect on instability.

Kopasakis, George↗