Thermal Analysis of a Solid Particle Light-Trapping Planar Cavity Receiver Using Computational Fluid Dynamics

Concentrated solar power (CSP) is one of the most effective ways of harnessing solar power to create efficient, durable, and resilient energy systems. This study entails thermal modeling and analysis of a novel central tower receiver configuration. This receiver uses solid particles as the heat transfer fluid (HTF), a promising option for third-generation CSP systems. The configuration considered here is the light-trapping planar cavity receiver (LTPCR) introduced by the National Renewable Energy Laboratory. While heat transfer studies of various LTPCR subsystems have been done, system-level thermal analysis of the LTPCR receiver has not been attempted. This study also presents important sensitivity analyses of the operating parameters of the CSP system, which can help guide the design of future central tower receivers. This study employs Ansys Fluent as a computational fluid dynamics (CFD) tool to model fluid dynamics and heat transfer in the receiver, intending to quantify its thermal performance. The model seamlessly integrates Monte Carlo ray tracing data, which generates absorbed solar flux profiles from the heliostat field design, with the heat transfer characteristics of the fluidized particle bed. This unified model is designed to accurately predict the thermal behavior of the LTPCR. Analysis of preliminary results reveals that the primary loss mechanisms are radiative and natural convective losses, in that order. Based on observations from a baseline case, several strategies are suggested and numerically tested. These solutions include selective cooling of high-temperature regions and manipulation of particle bed parameters. Selective cooling of high-temperature regions reduced the peak temperature by 151 degrees C and decreased thermal losses by 0.9%. Improving the particle-wall heat transfer coefficient (P-W HTC) of the particle bed decreased the thermal losses by 1.7% and decreased the peak temperatures by 57 degrees C. Decreasing the particle inlet temperature (PIT) also reduced thermal losses by 3.5% and decreased peak temperatures by 29 degrees C. Compounding these strategies improved the thermal losses of the receiver from 13.5% in the baseline case to 7.5%. Additionally, the study explores the variation in thermal performance across different locations of the receiver, where a variation of thermal losses from 12.9% to 17.3% is found. This allows a comprehensive evaluation of potential improvements in efficiency and temperature management.

computational fluid dynamics↗

Scaling considerations for supercritical carbon dioxide cycles including turbomachinery loss models

A modeling framework for the supercritical carbon dioxide recompressed closed Brayton cycle was developed. Unlike typical models, this effort incorporated generalized empirical turbomachinery loss models. Aerodynamic, windage, and leakage losses were considered in order to address the limitations of conventional constant-efficiency turbomachinery assumptions without relying on machine-specific or computationally expensive simulations. The model enables system-level exploration of optimal cycle design across a range of power scales, including smaller scales that are relevant to microreactors and extraterrestrial power applications. Parametric studies and multi-objective optimizations are used to evaluate the trade-offs between thermal efficiency and system compactness based on an analytical heat exchanger scaling model, yielding Pareto-optimal fronts across a range of operating pressures. Results reveal that at small power scales, the Pareto-optimal compressor inlet pressure becomes subcritical due to the increasing influence of density-dependent turbomachinery losses. Here, the relative contributions of each loss mechanism are quantified, and design recommendations are provided for key parameters such as recompression split ratio and generator cavity pressure across varying power scales.

Multi-objective optimization↗

Zinc batteries for grid-scale energy storage: Challenges, opportunities, and future directions

The global electricity sector is undergoing rapid transformation, increasing demand for reliable stationary energy storage and intensifying the need for safe, cost-effective, and scalable technologies for grid-scale applications. While lithium-ion batteries currently dominate the market, concerns over cost, safety, and resource availability motivate the exploration of alternative chemistries. Zinc-based batteries have emerged as a promising option due to the abundance, low cost, and wide geographic distribution of zinc, combined with the inherent safety of aqueous electrolytes. This perspective examines the potential of zinc batteries for stationary energy storage, with particular focus on rechargeable zinc-air systems. We discuss the evolution of zinc battery technologies and compare zinc-air, zinc-bromine, nickel-zinc, and aqueous zinc-ion chemistries, highlighting their advantages for grid applications. Key challenges limiting rechargeable zinc battery performance are analyzed, including dendrite formation and corrosion at the zinc anode, electrolyte degradation from carbonation and evaporation, and sluggish oxygen electrocatalysis at the air cathode. Emerging strategies to address these limitations are reviewed, including advanced electrode architectures, electrolyte engineering, catalyst development, and system-level design improvements. Lastly, we outline future research directions and opportunities for developing durable, efficient, and economically viable zinc-based energy storage systems for grid-scale applications.

Aqueous electrolytes↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing the deployment of solar-driven hydrogen from biomass at scale in the U.S.

Solar hydrogen from biomass gasification is a promising technology to sustainably produce hydrogen, responsibly dispose biomass waste, and reduce reliance on fossil fuels. However, its large-scale deployment faces challenges due to the geospatial misalignment between biomass resources and solar intensity, which introduces additional supply chain logistics costs. We analyze the logistics cost burden imposed by this misalignment and its impact on successful large-scale deployment of solar-driven hydrogen from biomass in the United States. We also consider associated carbon emissions and explore how the mix of deployed technologies evolves under externally imposed carbon penalties. Our findings show that while economies of scale are known to apply at the processing facility level, the reverse effect occurs at the broader systems-level, driven by logistics. Also, at current technology costs, high carbon penalties would be required to favor deployment of solar based technologies over conventional and hybrid alternatives. We further illustrate strategies and system-level changes to reduce logistics costs and enable sustainable, low-cost hydrogen for decarbonizing different industrial sectors.

Iloeje, Chukwunwike O. [Argonne National Laborator↗

Explaining System-Level Prognostics with Established Machine Learning Methods

System-level prognostics is crucial for ensuring reliability and enabling predictive maintenance in complex systems with interconnected components. This study presents a framework that integrates data-driven methods to predict the remaining useful life (RUL) of a subsystem under multiple and concurrent faults within a nuclear power plant system with explainable artificial intelligence (XAI). A nuclear power plant (NPP) operation was simulated to model the degradation behavior of NPP components, and four machine learning models—Gradient Boosting Regressor (GBR), Support Vector Regressor (SVR), Fully Connected Neural Network (FCNN), and Long Short-Term Memory (LSTM)—were evaluated for prognostics with a novel system RUL parameter. The LSTM model demonstrated potential superior repeatability, while SHAP (SHapley Additive exPlanations) for explainability provided consistent and trustworthy global explanations. In contrast, LIME (Local Interpretable Model-agnostic Explanations) offered localized interpretability but showed reduced stability for sequential data. Key findings include the interplay between component-level degradation and system-wide performance, with LSTM effectively capturing these dynamics through sequence-level predictions. The XAI techniques enhanced transparency by identifying critical features influencing model predictions and aligning with domain knowledge. Furthermore, this framework has significant implications for improving trust and understanding in predictive maintenance, particularly in safety-critical industries like nuclear energy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Small-Signal Stability Constrained Optimal Power Flow of Inverter-Dominated Power Systems with Flexible Operation Mode Selection

Given the intermittence and low inertia nature of inverter-based resources (IBRs), modern power systems with high penetration of IBRs challenge the conventional optimal power flow (OPF) analysis and the system may experience unexpected failures if stability constraints are not incorporated. This study proposes a small-signal stability-constrained OPF (SSSC-OPF) with flexible operation mode selection between grid-forming (GFM) and grid-following (GFL) modes for IBRs to address these challenges. The approach aims to maintain system stability with a sufficient stability margin while minimizing operation costs. The effectiveness of the proposed method is validated through extensive case studies on the IEEE 14-bus system. The results demonstrate that the proposed method is able to support system-level power flow analysis, reduce generation costs, and ensure stability under various disturbances.

grid-following↗

Titanium-Cerium Electrode-Decoupled Redox Flow Batteries Integrated With Fossil Fuel Assets For Load-Following, Long-Duration Energy Storage

Operation of fossil plants at partial capacity with frequent cycling results in decreased efficiency, increased emissions and increased wear and maintenance. The objective of this project is to advance the integration of a titanium-cerium electrode-decoupled redox flow battery (RFB) system with conventional fossil-fueled power plants through technical and economic system-level studies and component scale-up and R&D. The Ti-Ce chemistry has a pathway to meet the DOE cost targets of $\$$100/kWh and $\$$0.05/kWh-cycle owing to the use of low-cost, earth abundant elemental actives and incorporation of inexpensive carbon felt electrodes and non-fluorinated anion exchange membrane (AEM) separators. The initial unit cell design was scaled up, with some modifications made to improve ease of manufacturing, from 25 cm 2 cell area to 400 cm 2 . Electrochemical tests demonstrated operation at a current density up to 50 mA/cm 2 , which is on par with other commercial RFB offerings. Furthermore, the Ti-Ce technology developed by WashU was evaluated and tested by industrial team partner, Giner, Inc., in their modular 3-cell stack. Several cell design modifications and alternate component material selections were successfully implemented to accommodate this chemistry while reducing polarization and leakage. Results from stack testing show high columbic efficiency and indicate that further optimization of cell compression and components will lead to successful operation of the Ti-Ce ED-RFB over longer duration at the multi-cell stack level. Engineering and cost analysis showed that an RFB system with power output on the order of 100 MW and with a charge/discharge duration of approx. 12 hours is the most cost effective for integration with fossil plants. At this scale, projected cycling of fossil fuel power plants can be significantly reduced. The use of a storage system is shown to reduce the fossil plant standalone cost of electricity by $\$$7/MWh, through increased capacity factor and improved average efficiency, in the scenario of high penetration of renewable power.

20 FOSSIL-FUELED POWER PLANTS↗

Autonomous Fueling System for Heavy-Duty Fuel Cell Electric Trucks

The motivation for this project stemmed from the challenges associated with rapidly refueling heavy-duty hydrogen fuel cell electric trucks (FCETs). Current manual refueling processes for fast refueling involve large, heavy equipment (e.g., hoses three times heavier than standard) and pose ergonomic risks and potential for equipment damage. The goal was to develop and test an autonomous fueling system to improve ergonomics, enhance safety, increase equipment durability through design improvements, and potentially speed up the fueling process. This project aimed to add to the understanding of autonomous systems in the context of heavy-duty hydrogen refueling, evaluating the technical effectiveness of potential concepts. A successfully developed system would benefit the public by facilitating the adoption of zero-emission heavy-duty transport, reducing reliance on manual labor for a physically demanding task, and potentially improving the safety and efficiency of hydrogen refueling infrastructure. The major accomplishment during the project's active period was the completion of the system-level architecture task. This involved establishing a detailed list of system requirements covering interfaces, environmental conditions, regulatory compliance, industry standards, safety, security, performance capabilities, and optional features. Five key use cases for the autonomous system were also identified. However, due to internal restructuring at Nikola, the necessary resources could not be allocated to continue the project. Consequently, Nikola opted to discontinue the project. The award was mutually terminated by Nikola and the DOE.

08 HYDROGEN↗

Potential Impacts of Dynamic Electricity Pricing in California: Load Shape and Customer Bill Impacts Under Elastic Customer Response

The increasing penetration of renewable energy in California has intensified grid management challenges, exemplified by the “duck curve” and the resulting need for steep ramping and curtailment of renewables. To address these issues, dynamic electricity tariffs that vary in near-real time are being considered to incentivize customers to shift demand and support the grid. This study extends previous work on the bill impacts of such tariffs in the absence of load response by quantifying the system-level and customer impacts of load response based on customer price elasticity. Customer-level load response modeling was conducted using meter data from 411,000 customers across residential, commercial, and industrial sectors. Customer demand elasticity was estimated using literature-based values, with scenarios ranging from low to high elasticity, including an automation-enhanced scenario. Results indicate that universal adoption of, and response to, dynamic tariffs can significantly reduce peak net load (by 15%) and maximum ramping requirements (by 20%) with moderate elasticity, delivering demand response resources comparable to or exceeding current programs at all elasticity levels. Bill analysis shows that, when responding elastically to dynamic prices, most non-PV customers experience modest savings, while PV customers may see higher effective rates due to lower compensation for exports during low-price periods. Emissions analysis reveals a reduction in per-kWh emissions system-wide, with a total absolute load increase of 2% accompanied by a negligible absolute emissions increase. The study concludes that while dynamic tariffs offer substantial grid benefits, customer bill savings under modeled response behaviors may be too modest to drive widespread adoption without additional incentives or enabling technologies. Future research should model flexible loads and advanced control technologies with greater fidelity to better represent the potential opportunities of dynamic tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Game Theory Approaches for System-level Incentive Design

This report presents a generalized Stackelberg game framework for designing and evaluating financial incentives that enhance power system resilience through strategic deployment of distributed energy resources(DERs) under various contingencies. The proposed approach addresses the challenge of coordinating individual community investment decisions to meet system-wide resilience objectives. The framework is demonstrated in a three-community test system subjected to two transmission contingency scenarios: inter-community line failure (Case 1) and complete main grid disconnection (Case 2). In both cases, three incentive levels are compared: a Base case with no financial incentives, and low and high incentive cases. In Case 1, the Base case (no incentives) results in a total installed DER capacity of 217.2 MW, with no load shedding due to alternative routing, but community costs remain high. Increasing incentives raises DER deployment to 286.9 MW, lowers aggregate community costs by $22M annually, and completely avoids the need for costly new transmission line construction. In Case 2, the Base case results in 24.3 MWh of unserved load; introducing incentives eliminates all load shedding and ensures up to 89 MWh of battery storage is available for emergency reserve. These results demonstrate that targeted incentives can dramatically improve grid resilience and cost-effectiveness. The framework thus offers policymakers and system planners a robust tool to quantify and compare the effectiveness of incentive programs for multi-community transmission networks behavior, system resilience, and economic efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unified Universal Control and Coordination of Inverter-Based Resources, and Validation for a PV + Battery Hybrid Plant

As renewable energy deployment grows, hybrid power plants (HPPs) combining photovoltaic (PV) and battery systems must evolve to offer both energy and grid stability services. These systems typically include a mix of grid-following (GFL) and grid-forming (GFM) inverters, presenting unique coordination and control challenges. This Department of Energy–funded project developed and validated a Unified Universal Control and Coordination (UUCC) framework for such PV + battery hybrid plants, enabling seamless and stable operation, including ultrafast black start, autonomous synchronization, and robust frequency and voltage regulation, under different grid conditions. The project significantly advanced the understanding of inverter-based resource (IBR) control by developing and validating three complementary system-level approaches for hybrid GFL/GFM operation: 1. A combined Virtual Resistance (VR)-based GFL and Virtual Oscillator Control (VOC)-based GFM method, where each inverter type is governed by a specialized control strategy. Together, these achieve stable, fast-response coordination, eliminating inrush current and enabling smooth black start and grid synchronization across a wide range of grid strengths. 2. A Deadbeat-based UUCC strategy, which uses discrete-time, switching-cycle-level control for both GFL and GFM inverters. This approach replaces traditional PI/PLL control with a control parameter-free, high-bandwidth framework that supports stable LVRT and instantaneous synchronization under all conditions. 3. A benchmark comparison with Siemens’ commercial GFM microgrid controller, which provided a fast baseline platform. The commercial approach decoupled v & f control was implemented on a commercial microgrid controller.The baseline commercial benchmark helped highlight superior transient response and black start performance offered by the deadbeat and VOC approaches. These technical contributions offer substantial improvements over conventional inverter control schemes, which often rely on slow phase-locked loop (PLL)-based synchronization, require careful control parameters tuning, and prone to unstable in weak grids with GFL inverters and in stiff grid with GFM inverters therefore challenging for hybrid GFL+GFM under all grid conditions. The deadbeat-based UUCC framework enables simpler, faster, and more robust operation of hybrid IBR systems using wide-bandgap (WBG) devices such as SiC power semiconductors. The rapid expansion of hybrid distributed energy resources (DERs), including residential and commercial PV-BESS installations such as Tesla Powerwall, PV with vehicle-to-grid (V2G) capability, and other integrated configurations, presents complex operational challenges for medium-voltage radial distribution feeders. These networks are subject to frequent disturbances such as faults, switching operations, rapid reclosing sequences, and feeder reconfigurations, all of which introduce dynamic stress on IBRs. In addition, planned feeder segmentation and deliberate islanding for resilience will require DERs that can autonomously perform blackstart, establish voltage and frequency references, and resynchronize with the main grid. The advanced deadbeat-based UUCC control and blackstart functionalities developed in this project directly address these requirements, enabling decentralized and autonomous operation of inverter-dominated DERs in distribution systems under a wide range of fault and reconfiguration scenarios. From a public benefit perspective, these innovations enable more reliable and cost-effective integration of renewable energy into distribution networks. The ability to autonomously black start and stabilize grids under varying grid conditions support accelerates recovery from outages and support decentralized resilient energy systems. By reducing system complexity and improving performance, this project lays critical groundwork for future inverter-dominated power grids that are clean, reliable, and accessible to all.

14 SOLAR ENERGY↗

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗

Analyzing Potential Failures and Effects in a Pilot-Scale Biomass Preprocessing Facility for Improved Reliability

This study demonstrates a failure identification methodology applied to a preprocessing facility generating conversion-ready feedstocks from biomass meeting conversion process critical quality attribute (CQA) specifications. Failure Modes and Effects Analysis (FMEA) was used as an industrially relevant risk analysis approach to evaluate a logging residue preprocessing system to prepare feedstock for pyrolysis conversion. Risk evaluations considered both system-level and operation unit-level assessments considering process efficiency, product quality, cost, sustainability, and safety. Key outputs included estimations of semi-quantitative risk scores for each failure, identification of the failure impacts, identification of failure causes associated with material attributes and process parameters, ranking success rates of failure detection methods, and speculation of potential mitigation strategies for decreasing failure risk scores. Results showed that deviations from moisture specifications had cascading consequences for other CQAs along with process safety implications. Failures linked to fixed carbon specifications carried the highest risk scores for product quality and process efficiency impacts. As increased throughput can be inversely related to meeting product quality specifications; achieving throughput and other material-based CQAs simultaneously will likely require system optimization or prioritization based on system economics. Ultimately, this work successfully demonstrates FMEA as a risk analysis approach for other bioenergy process systems.

09 BIOMASS FUELS↗

A Centralized AI Lakehouse Framework for Brain Tumor MRI Classification and Segmentation, University KPI Forecasting, and Water Potability Prediction

In many university and healthcare projects, models are built for very different data types such as tables, institutional time series, and medical images, but they are deployed as separate applications. In this work, that separation made testing and maintenance difficult because each module had its own pipeline and runtime requirements. This paper presents an integrated AI lakehouse-style implementation that runs three model pipelines inside one containerized backend. For medical imaging, we used MRI datasets from IEEE DataPort: a four-class classification set with 7012 images (5708 train/1304 test) and a segmentation set with 3063 image–mask pairs. The classification model (ResNet50 transfer learning) is evaluated using a proper train–validation–test protocol across multiple splits (80/10/10, 70/10/20, 60/10/30, and 10/30/60), achieving a test accuracy of 99.00% under the standard 80/10/10 split. Additionally, a patient-level evaluation is conducted using an external glioma dataset to provide a more realistic assessment without data leakage. The segmentation model (DeepLabV3-ResNet50) achieved 83.09% validation mIoU and 88.79% Dice score. For university KPI forecasting, we used annual IPEDS and NSF HERD data from 2010 to 2023 for three universities (BSU, EOU, and UAB). To examine the effect of preprocessing on forecasting performance, two case studies are conducted. In the first case, linear interpolation is applied to generate semester-level data. In the second case, the original annual data is used directly without interpolation. Random Forest regression and ARIMA models are evaluated using MAE, RMSE, MAPE, and R 2 . The results showed that interpolation improved apparent forecasting performance due to smoothing, while evaluation on the original annual data provided a more realistic assessment of model behavior. To further validate the framework on a larger dataset, an additional case study is conducted using a student dropout dataset. For water potability, we trained and compared multiple tabular classifiers on a large dataset (1,048,575 samples). A Random Forest model (100 trees, max depth 10) achieved 85.86% test accuracy and high recall for unsafe samples (0.8447). All modules are served via FastAPI and deployed together using Docker, with workflow automation routing requests to the correct endpoint. System-level benchmarking indicates that the backend maintains stable throughput and latency under concurrent requests.

97 MATHEMATICS AND COMPUTING↗

NLR Core Modeling & Decision Support Capabilities: FASTSim, RouteE, T3CO & OpenPATH

This project is part of the program area to develop and improve core capabilities for the Energy-Efficient Mobility Systems (EEMS) program that enable research, development and deployment of advanced mobility solutions and enhance the EEMS Program's ability to address system-level transportation challenges. Advancements to the Future Automotive Systems Technology Simulator (FASTSim), Route Energy Prediction Model (RouteE), Transportation Technology Total Cost of Ownership (T3CO) and Open Platform for Agile Trip Heuristics (OpenPATH) core capabilities under this project supports the overall EEMS Program goals to effectively evaluate energy and mobility impacts of future transportation technologies and services, and to identify the most promising pathways to reduce transportation costs and environmental harms, and to improve mobility access. This presentation was prepared for the 2026 Annual Merit Review of this project.

33 ADVANCED PROPULSION SYSTEMS↗

Study the Protection Improvements for a Weak Grid Area With High IBRs

NLR is collaborating with Florida Power & Light (FPL) and GE to investigate power system stability and protection reliability challenges in a weak-grid region with high penetration of inverter-based resources (IBRs). This presentation will primarily focus on the protection aspects of the study. We will share key insights from this real-world project, including best practices for developing high-fidelity fault study models, establishing a controller-hardware-in-the-loop (CHIL) platform for testing physical relays, identifying system-level protection challenges, and designing enhanced protection schemes to address those issues. Through this discussion, the audience will gain practical understanding of protection studies in IBR-dominated systems, the emerging challenges associated with reduced fault current and altered transient behavior, and effective mitigation strategies. In particular, we will highlight the critical importance of IBR compliance with IEEE 2800-2022 to ensure dependable and secure protection relay operation in modern transmission systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗