Techniques and instrumentation effort for whale migration tracking

The following aspects of a research program concerned with tracking gray whales were documented: (1) design, fabrication and testing of a girdle-type harness and associated gear (release mechanism, tracking transmitter, xenon flasher), (2) design, fabrication and testing of instrumentation packs (subminiature recorder, sensor, electronics), (3) field preparations for the January-February 1974 expedition off Mexico, (4) travel arrangements, (5) preliminary field report (capture and handling of juvenile whales, instrumentation and housing tests, harness abrasion and chafing, respiration measurements, sea tracking, distribution, number, and behavior of whales at Lopez Mateos), (6) review, data reduction, and analysis of results.

Goodman, R. M.↗

Downward-deployed tethered satellite systems, measurement techniques, and instrumentation - A review

This paper describes a number of scheduled and proposed Shuttle-based downward-deployed tethered satellite systems (TSSs) the purpose of which is to determine the structure of the lower thermosphere and to measure the atmospheric and aerodynamic effects in the vicinity of the satellite, the aerothermodynamic effects on the satellite's surface, and the dynamics of the tether and its endmass, the satellite. The instruments for the downward-deployed tethered missions will include mass spectrometers and other density sensors, plasma instrumentation, optical spectrophotometers, magnetometers, and instrumentation to measure the effects on satellite surface (such as the surface temperature, heat transfer, and pressure; gas adsorption on surfaces, chemistry with other gas molecules and surface material, and desorption from the surface; and surface charging).

Brown, Kenneth G.↗

Astronomical CCD observing and reduction techniques

CCD instrumentation and techniques in observational astronomy are surveyed. The general topics addressed include: history of large array scientific CCD imagers; noise sources and reduction processes; basic photometry techniques; introduction to differential time-series astronomical photometry using CCDs; 2D imagery; point source spectroscopy; extended object spectrophotometry; introduction to CCD astrometry; solar system applications for CCDs; CCD data; observing with infrared arrays; image processing, data analysis software, and computer systems for CCD data reduction and analysis. (No individual items are abstracted in this volume)

Howell, Steve B.↗

Exploration of the solar system by infrared remote sensing

The remote sensing of objects in the solar system using infrared radiation is discussed. Theories of radiative transfer, molecular spectroscopy, and atmospheric physics are used to show how infrared spectra of model planetary atmospheres are calculated. Instrumental techniques are described and the effect of instruments on the measurement of the emerging radiation field is addressed. Techniques that allow the retrieval of atmospheric and surface parameters from observations are examined. All the planets except Pluto are studied, and many of the planetary satellites.

Hanel, R. A.↗

Improved Chromatographic Techniques for Sulfur Pollutants

This paper describes several improvements in instrumental techniques for the analysis of low ppb concentrations of sulfur gases using gas chromatography (G.C.). This work has focused on the analytical problem of ambient air monitoring of the two main sulfur gas pollutants, hydrogen sulfide and sulfur dioxide. The most significant technical improvement that will be reported here is the newly developed silica gel column for ppb concentrations of the light sulfur gases (COS, H2S, CS2, SO2, CH3SH). A simplified inlet system will be described which improves reliability of the GC system. The flame photometric detector is used as the means of selectively and sensitively detecting the low concentrations of sulfur gases. Improvements will be described which have yielded better performance than previously reported for this application of the detector. Also included in this paper will be a report of field monitoring using this improved GC system. Reliability and repeatability of performance at the low ppb concentrations of sulfur gases will be demonstrated.

Hartmann, C. H.↗

Development of Techniques to Investigate Sonoluminescence as a Source of Energy Harvesting

Instrumentation techniques are being developed at NASA Glenn Research Center to measure optical, radiation, and thermal properties of the phenomena of sonoluminescence, the light generated using acoustic cavitation. Initial efforts have been directed to the generation of the effect and the imaging of the glow in water and solvents. Several images have been produced of the effect showing the location within containers, without the additions of light enhancers to the liquid. Evidence of high energy generation in the modification of thin films from sonoluminescence in heavy water was seen that was not seen in light water. Bright, localized sonoluminescence was generated using glycerin for possible applications to energy harvesting. Issues to be resolved for an energy harvesting concept will be addressed.

Wrbanek, John D.↗

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

Evaluation of Wing Load Calibration and Sensing Methods Using Conventional Strain Gages and a Fiber Optic Sensing System Installed on a Straight Tapered Wing

State-of-the-art instrumentation techniques have provided an opportunity to obtain greater insight into structural wing loads during flight. An investigation was undertaken to research new wing instrumentation and load sensing techniques for measuring accurate in-flight spanwise load distributions on wing structures. A straight tapered wing was instrumented with both conventional foil strain gages at five spanwise wing stations and fiber optic strain sensors at every half inch along the entire wing span. Thirty-nine unique load cases were applied to the wing lower surface using hydraulic actuators to obtain various shear, bending moment, and torque load distributions on the wing. This paper will highlight three load calibration approaches. Conventional linear regression calibration methods were applied to foil strain gages providing a single wing station vertical shear, bending moment, and torque load. Linear regression methods were applied to a fiber optic sensing system to provide bending moment and torque spanwise load distributions. A load sensing scheme using strain derived wing shape information derived from a single load case provided vertical shear and bending moment spanwise load distribution information. Aspects of the three different approaches will be compared and contrasted to inform the reader of the benefits or disadvantages of each. Instrument installation, sensor characteristics, test execution aspects, and recommended calibration techniques will be discussed.

structural mechanics↗

Embedded acoustic sensing and monitoring techniques for small modular reactors

The goal of this project was to study the applicability of specific innovative instrumentation techniques for assessing parameters needed for safe small modular reactor operation and safeguarding of nuclear material. Small modular reactor core designs are currently being developed to provide energy more effectively and efficiently than in the past because they can be built as modules at fabrication sites and then transported to a power-producing facility. However, these modules and/or the final core will often be sealed and not accessible again until disposal. Instead of instruments that access the core directly, during and after operation, to monitor flux/dose and structural integrity, as current power plants use, new sensors need to be designed that can be built into the reactor initially to determine operating history, structural integrity through operation of the system, and nuclear material accountancy after shutdown and before disposition of the core. Embedded sensors already exist that can provide neutron flux, gamma dose, and temperatures, but techniques to expand upon these for assessing structural health and material inventory in the system over time need to be developed. Structural health assessments include the detection and imaging of cracks in the components that could eventually cause radioactive fission products to be released.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗