SEARCH · Search NASA
Results for “techno”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Techno-economic evaluation of different hybridization schemes for a solar thermal/gas power plant
Not provided.
Techno-economic analysis of an integrated gasification direct-fired supercritical CO2 power cycle
Not Available
Techno-economic analysis of chemical looping air separation using a perovskite oxide sorbent
Not provided.
Techno-economic analysis of supercritical extraction of rare earth elements from coal ash
Not Available
Prospects of hydrogen cogeneration and carbon dioxide utilization in electrochemical refineries for ethylene production via oxidative coupling of methane: A techno-economic assessment
Ethylene is recognized as one of the most significant chemicals globally. The projected ethylene production for 2023 stands at 227.6 million tonnes, with expectations of continued demand growth. The primary use of ethylene, accounting for over 76%, lies in the production of plastics such as polyethylene, polyvinyl chloride, and polystyrene. Despite the enduring carbon retention potential of plastics themselves, traditional ethylene feedstock production from fossil resources contributes substantially to greenhouse gas emissions, ranging from 0.29 to 2.29 kg CO2 /kg Ethylene depending on various factors like feedstock and process design. Various decarbonization strategies, including the utilization of hydrogen as a primary heat source, have been proposed to reduce the carbon footprint of ethylene production, but their efficacy remains limited, offering at best a 0–30% reduction in on-site CO 2 emissions.
Techno-economic life cycle assessment of CO 2 -EOR operations towards net negative emissions at farnsworth field unit
Optimizations of CO 2 Water Alternating Gas(WAG)- systems with multi-objectives of incremental recovery and maximization of CO 2 storage are challenging. Here, the incorporation of a total Greenhouse gas (GHG) life cycle assessment is mostly ignored leading to inaccurate estimation of overall net carbon emissions of their operations. In this study, the effect of a total GHG life cycle assessment on a multi-objective CO 2 -WAG optimization with integrated techno-economic assessment (TEA) which factors carbon tax credit is conducted. A life cycle assessment (LCA) was conducted utilizing a 20 -year optimized post history matched data from a high fidelity reservoir simulation model. Using data generated from the optimum result, a techno-economic life cycle analysis was further conducted. The first scenario classified as the base model had an estimated 81% of purchased CO 2 sequestered. The results through a comprehensive techno-economic LCA model yielded a net estimate of 73% of purchased CO 2 . The optimized forecasted model which considered key operational and reservoir factors such as WAG ratio, injection rates and periods, and well specification resulted in an improved sequestration of 92% of purchased CO 2 . However, this also dropped to 84% after taking it through LCA. These results clearly indicate a significant amount of net CO 2 is not accounted for when operations are not analyzed through LCA. From the LCA, direct flaring volumes of CO 2 , energy consumption and efficiency of unit equipment were noticed to be the major causes of these reductions. Considering ten main sources of energy as source of energy generation, a comparative techno-eco LCA was conducted. The results confirmed a lower net volume and NPV for energy sources with higher carbon footprints and vice versa. Thus, a total LCA of CO 2 -WAG greatly influences net storage factor of purchased CO 2 and hence project NPV where tax credit/incentives per ton of CO 2 sequestered is considered. Although operational conditions are optimized for best results, there are significant factors that leads to minimization of net storage factor. This study therefore provides an insightful information for optimizing CO 2 -WAG multi-objectives to achieve minimum GHG emission.
Reservoir Characterization and Techno-Economic Analysis of Enhanced Geothermal and Closed-Loop Systems in the Wattenberg Field of the Denver-Julesburg Basin, Colorado
This report provides details of reservoir characterization and techno-economic analysis for enhanced geothermal systems and closed-loop geothermal systems in the Denver-Julesburg Basin Wattenberg area. The analysis contributes to the Geothermal Limitless Approach to Drilling Efficiencies (GLADE) project, a multi-institutional research initiative focused on advancing geothermal energy development by reducing drilling costs and improving the rate of penetration. The GLADE project brings together national laboratories, academic institutions, and industry partners, including the U.S. Department of Energy's Geothermal Technologies Office, Occidental Petroleum, the National Laboratory of the Rockies (NLR), Los Alamos National Laboratory, Colorado School of Mines, Louisiana State University, Texas A&M University, and several drilling technology companies. As part of this effort, NLR developed and applied slender-body theory modeling tools and the GEOPHIRES simulator to support techno-economic analysis. The slender-body theory wellbore simulator evaluated thermal performance in U-loop, Eavor-type multilateral, and enhanced geothermal system well configurations. Results indicated that an optimized single U-loop design delivers an outlet temperature of 168.8 degrees Celsius,stabilizing at a final outlet temperature of 135.3 degrees Celsius. Heat production also improved significantly, with an average thermal output of 16.9 MWth and a final thermal output of 11.0 MWth. These results provided critical baseline data for selecting optimized systems for techno-economic analysis. Building on these outputs, NLR applied the GEOPHIRES techno-economic simulator to estimate the levelized cost of electricity for both the Eavor multilateral and enhanced geothermal systems. The sensitivity analysis showed that drilling costs exert a particularly strong impact on the levelized cost of electricity of multilateral systems. Therefore, advances in drilling technology and improved drilling rates could yield significant gains in the economic performance of these systems. In this context, the GLADE project directly supports the U.S. Department of Energy's mission to reduce the cost of geothermal energy and accelerate the deployment of next-generation geothermal technologies.
An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems
District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.
Techno-economic feasibility of geothermal energy production using inactive oil and gas wells for district heating and cooling systems in Tuttle, Oklahoma
Oil and gas wells have been drilled in the United States and often encounter hot co-produced water possibly suitable for geothermal direct-use applications. Here this study evaluated geothermal resources, heating and cooling demand, and techno-economic potential of four oil and gas wells repurposed for geothermal energy production to serve two public schools and 250 nearby houses in Tuttle, Oklahoma, USA. Subsurface geology in the study area primarily consists of Permian to Mississippian sandstone and limestone formations approximately from 2 km to 3.5 km depth. With a geothermal gradient of 25.3 °C/km, the temperature of geothermal energy production was estimated as 68.2 °C at 2.1 km. The potential of calcite scaling within boreholes and pipes was minimal. Using the characterized reservoir properties, techno-economic analyses were conducted for evaluating levelized costs of geothermal energy production for direct-use heating and cooling and district heating systems with five different production scenarios. Heating and cooling demand in two schools and 250 houses and additional 0.3 MW and 0.6 MW base heating loads for potential geothermal direct-use applications in the study area were also incorporated in the modeling. Results indicated that the levelized cost of heating of geothermal district heating systems utilizing existing wells were significantly lower than those of conventional geothermal energy systems that include well drillings. The geothermal energy production with doublet and quartet configurations was generally sufficient to supply total annual heating demand in the district, while a peaking boiler was used to supply peak loads. Doublet configurations showed higher production temperature with a lower thermal drawdown than the quartet configurations. The doublet system at 2.1 km production depth with 9.3 kg/s flow rate represented the optimal levelized cost of $71/MWh and 91.2% utilization factor. These results imply that the Tuttle geothermal district heating system is techno-economically feasible and comparable to geothermal district heating systems in the United States and the regional natural gas rate for residentials by recycling inactive oil and gas wells with no drillings.
Techno-economic and environmental assessment of solar-based electrical vehicles charging stations integrated with hydrogen production
With the growing interest in adopting both commercial and residential electric vehicles (EVs) utilizing green renewable energy, the techno-economic assessment of EV charging stations with solar energy is a critical aspect of the transition to sustainable transportation. However, battery storage capacity for variable solar energy production is becoming increasingly less cost-effective due to the higher Lithium price. Complementing solar energy production and battery storage, the potential of combining green hydrogen fuel energy integration with solar energy for EV charging stations can provide a sustainable alternative to reach carbon-free transportation. This research aims to assess the technical and economic viability of grid-connected Photovoltaic (PV)-based EV charging stations across Kentucky based on existing EV load profiles. The study considers different PV system sizes, locations, orientations, and the impact of net metering policies and electricity tariffs on the profitability of the PV systems. Further, using excess PV energy, Lithium-Ion batteries will be charged, which will be assessed considering the techno-economic and environmental impacts of green EV charging stations. To further enhance green renewable energy production, we also investigated the feasibility of on-grid PV-based EV charging stations with Lithium-Ion batteries charged during low tariff periods. In comparison with these scenarios, we studied the potential benefits of integrating green hydrogen energy production using excess solar energy with and without governmental incentives. Furthermore, we assess the environmental impact of these green EV charging stations across Kentucky. Our study indicates that EV stations across Kentucky have similar techno-economic feasibility with insignificant deviation in the levelized cost of electricity, payback period, and PV energy fraction with/without Li-Ion batteries. However, with green hydrogen production, the marginal H 2 production cost indicates the first scenario (on-grid PV energy charging) is the most significant, roughly 10 USD/Kg, which is similar to 1.5 times higher than the second (charging during low-tariff periods) and the third scenarios (power grid to satisfy the demand deficit - approximately 6.5 USD/Kg). From the environmental perspective, the second scenario would be a good option for either hybrid EV/H 2 or EV charging stations in Kentucky, factoring in the hydrogen production cost and the carbon footprint.