Search NASA⌕ Search

SEARCH · Search NASA

Results for “texture analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

SU-E-J-265: Feasibility Study of Texture Analysis for Prognosis of Local Tumor Recurrence Within 5-Years for Pharyngeal-Laryngeal Carcinoma Patients Received Radiotherapy Treatment

Purpose: Pharyngeal and laryngeal carcinomas (PLC) are among the top leading cancers in Asian populations. Typically the tumor may recur and progress in a short period of time if radiotherapy fails to deliver a successful treatment. Here we used image texture features extracted from images of computed tomography (CT) planning and conducted a retrospective study to evaluate whether texture analysis is a feasible approach to predict local tumor recurrence for PLC patients received radiotherapy treatment. Methods: CT planning images of 100 patients with PLC treated by radiotherapy at our facility between 2001 and 2010 are collected. These patients were received two separate CT scans, before and mid-course of the treatment delivery. Before the radiotherapy, a CT scanning was used for the first treatment planning. A total of 30 fractions were used in the treatment and patients were scanned with a second CT around the end of the fifteenth delivery for an adaptive treatment planning. Only patients who were treated with intensity modulated radiation therapy and RapidArc were selected. Treatment planning software of Eclipse was used. The changes of texture parameters between two CT acquisitions were computed to determine whether they were correlated to the local tumor recurrence. The following texture parameters were used in the preliminary assessment: mean, variance, standard deviation, skewness, kurtosis, energy, entropy, inverse difference moment, cluster shade, inertia, cluster prominence, gray-level co-occurrence matrix, and gray-level run-length matrix. The study was reviewed and approved by the committee of our institutional review board. Results: Our calculations suggested the following texture parameters were correlated with the local tumor recurrence: skewness, kurtosis, entropy, and inertia (p<0.0.05). Conclusion: The preliminary results were positive. However some works remain crucial to be completed, including addition of texture parameters for different image features, sensitivity of tumor segmentation variations, and effect of image filtering.

60 APPLIED LIFE SCIENCES↗

Virtual texture analysis to understand microstructure effects on deformation twinning and detwinning behavior in BCC metals

Understanding and predicting deformation twinning contributions to plastic deformation in BCC metals has been a long-standing challenge due to the interplay with dislocation slip and non-Schmid effects that render an asymmetry under tension and compression. This paper uses molecular dynamics simulations to understand the effect of unloading and grain orientation on deformation twinning in a nanocrystalline Fe (nc-Fe) system as a model BCC metal. The nc-Fe system is loaded under uniaxial stress tension and compression to understand the effect of grain orientation (Schmid effects) on deformation twinning behavior and the tension/compression asymmetry (non-Schmid effects). A new virtual texture analysis “VirTex” tool is used to understand the role of grain orientation on the nucleation of twins and their contributions to the observed stress–strain response. For certain grain orientations, the twinnability is observed to be different in tension and compression. In addition, the flow stress accommodation from twins in certain grains is observed to be different in tension and compression and different from that for the grains. Subsequent unloading leads to detwinning in the deformed microstructures, where the extent of detwinning depends on the strain from which the system is unloaded and on the morphology of the twin. Lastly, the simulations are carried out to analyze the role of the Schmid factor on the twinnability and asymmetry in tension and compression.

Kannan, Aadhithyan [University of Connecticut, Sto↗

Quantitative texture analysis at the WAND 2 and HIDRA diffractometers

Data collection and analysis strategies have been developed for efficient and reliable crystallographic texture measurements at two recently upgraded neutron diffractometers: the Wide Angle Neutron Diffractometer Squared (WAND 2 ) and the High Intensity Diffractometer for Residual Stress Analysis (HIDRA) at the High Flux Isotope Reactor located at Oak Ridge National Laboratory. These methods are demonstrated using measurements on a variety of textured samples, including multi-phase steel composites and polycrystalline calcite (CaCO 3 ). Reference measurements were also made at VULCAN, the engineering diffractometer located at the Spallation Neutron Source. The texture data obtained on the different instruments are in agreement, and WAND 2 is more time efficient than HIDRA. Two analysis methods were investigated, single-peak fitting to obtain individual pole figures for inversion and Rietveld texture analysis using MAUD. Here, the impact of the differences between the various textures obtained was evaluated through the calculation of diffraction elastic constants, which is one application of the texture data collected. Both instruments were found to provide texture data that are suitable for complementing other analyses, such as residual stress mapping.

47 OTHER INSTRUMENTATION↗

Modified Peak Ratio Method for Quantitative Texture Analysis of U10Zr Alloys

The objective of this work is to develop a time- and cost-efficient, accurate technique to determine texture properties of TerraPower zirconium-bearing and other alloyed fuel materials. It is also the desire of the customer to obtain quantitative or semi-quantitative results from these measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-D-9A-03: STAMP: Simulator for Texture Analysis in MRI/PET

Purpose: To develop a convenient simulation platform to facilitate PET/MR image analysis with the prospect of gaining a better understanding of the influence of acquisition parameters on PET/MRI textural features. The simulation platform is demonstrated by showing textural variations of a representative case study using different image acquisition parameters. Methods: The simulation platform is composed of MRI simulators JEMRIS and SIMRI to achieve simulations of customized MRI sequences on sample tumor models. The PET simulator GATE is used to get 2D and 3D Monte Carlo acquisitions of voxelized PET sources using a phantom geometry and a customized scanner architecture. The platform incorporates a series of graphical user interfaces written in Matlab. Two GUIs are used to facilitate communication with the simulation executables installed on a computer cluster. A third GUI is used to collect and display the clinical and simulated images, as well as fused PET/MRI images, and perform computation of textural features.To illustrate the capabilities of this platform, one FDG-PET and T1-weighted (T1w) digitized tumor models were generated from clinical images of a soft-tissue sarcoma patient. Numerically simulated MR images were produced using 3 different echo times (TE) and 5 different repetition times (TR). PET 2D images were simulated using an OSEM algorithm with 1 to 32 iterations and a post-reconstruction Gaussian filter of 0, 2, 4 or 6 mm width. Results: STAMP was successfully used to produce numerically simulated FDG-PET and MRI images, and to calculate their corresponding textures. Three typical textures (GLCM-Contrast, GLSZM-ZSV and NGTDM-Coarseness) were found to vary by a range of 45% on average compared to reference scanning conditions in the case of FDG-PET, and by a range of 40% in the case of T1w MRI. Conclusion: We have successfully developed a Matlab-based simulation platform to facilitate PET/MRI texture image analysis for outcome prediction.

60 APPLIED LIFE SCIENCES↗

Quantitative texture analysis using the NOMAD time-of-flight neutron diffractometer

Strategies for efficient and reliable texture measurements have been explored using the Nanoscale Ordered Materials Diffractometer (NOMAD) at the Spallation Neutron Source located at Oak Ridge National Laboratory (ORNL). To test these strategies, the texture of an Al alloy was also investigated using another neutron diffraction instrument, a constant-wavelength neutron diffractometer (NRSF2) located at the High Flux Isotope Reactor, also at ORNL. Reasonable agreement was found across the two experimental methods, but differences in overall texture strength and the symmetry of some components were noted, depending on the data reduction and analysis method selected. Finally, on the basis of these results, potential improvements are identified which would enhance the texture measurement capability on NOMAD.

47 OTHER INSTRUMENTATION↗

TU-F-18C-09: Mammogram Surveillance Using Texture Analysis for Breast Cancer Patients After Radiation Therapy

Purpose: To study the feasibility of applying cancer risk model established from treated patients to predict the risk of recurrence on follow-up mammography after radiation therapy for both ipsilateral and contralateral breast. Methods: An extensive set of textural feature functions was applied to a set of 196 Mammograms from 50 patients. 56 Mammograms from 28 patients were used as training set, 44 mammograms from 22 patients were used as test set and the rest were used for prediction. Feature functions include Histogram, Gradient, Co-Occurrence Matrix, Run-Length Matrix and Wavelet Energy. An optimum subset of the feature functions was selected by Fisher Coefficient (FO) or Mutual Information (MI) (up to top 10 features) or a method combined FO, MI and Principal Component (FMP) (up to top 30 features). One-Nearest Neighbor (1-NN), Linear Discriminant Analysis (LDA) and Nonlinear Discriminant Analysis (NDA) were utilized to build a risk model of breast cancer from the training set of mammograms at the time of diagnosis. The risk model was then used to predict the risk of recurrence from mammogram taken one year and three years after RT. Results: FPM with NDA has the best classification power in classifying the training set of the mammogram with lesions versus those without lesions. The model of FPM with NDA achieved a true positive (TP) rate of 82% compared to 45.5% of using FO with 1-NN. The best false positive (FP) rates were 0% and 3.6% in contra-lateral breast of 1-year and 3-years after RT, and 10.9% in ipsi-lateral breast of 3-years after RT. Conclusion: Texture analysis offers high dimension to differentiate breast tissue in mammogram. Using NDA to classify mammogram with lesion from mammogram without lesion, it can achieve rather high TP and low FP in the surveillance of mammogram for patient with conservative surgery combined RT.

60 APPLIED LIFE SCIENCES↗

Virtual texture analysis to investigate the deformation mechanisms in metal microstructures at the atomic scale

Understanding the deformation behavior of metallic materials at high strain rates requires the characterization of plasticity contributors such as twins, phase transformed regions, and dislocations. However, predicting the contributions from phase transformation and twinning relies on a complete understanding of the selection of variants for various loading orientations and the evolution of their volume fractions. This manuscript presents a new virtual texture (VirTex) analysis approach to characterize phase transformation and twinning variants in deformed microstructures generated using molecular dynamics (MD) simulations. Furthermore, the VirTex method involves the construction of a rotation matrix to calculate the angle/axis pairs and misorientation angles for each atom in the microstructure. Any changes in the orientation angle from angle/axis pairs and/or structure types are analyzed to determine the nucleation and evolution of variants in the microstructure. The study uses shock deformed single-crystal Fe, Ta, and Cu to analyze the variant selections for phase transformation or twinning or both in BCC and FCC systems. In addition, the VirTex analysis is able to characterize the phase transformation and twinning variants in nanocrystalline Fe and Ta microstructures. Besides characterizing variants, orientation mapping also provides an accelerated and on-the-fly approach for quantifying twin fractions in MD microstructures.

36 MATERIALS SCIENCE↗

X-Ray Diffraction Texture Analysis of Uranium Alloy Fuel PLN-5527 R0

This test plan describes XRD sample characterization for uranium alloys. This test plan includes preferred sample preparation information, characterization method, instrument parameters, calibration method, analysis software, data-acceptance requirements, documentation/reporting requirements. Texture measurements will be taken based on relative peak shapes (e.g., peak height, area, integrated intensity, etc.), relative to the individual XRD pattern.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phase and texture analysis of a hydride blister in a Zr-2.5%Nb tube by synchrotron x-ray diffraction.

This paper presents a detailed phase and texture study within and around a hydride blister grown on the surface of a Zr-2.5%Nb pressure tube. The analysis is based on synchrotron X-ray diffraction experiments using an 80 keV photon beam and a high-speed area detector placed in transmission geometry. It was found that the blister is composed of two main phases, {alpha}-Zr and {delta}-ZrH, with a composition which changes locally across the blister. No location within the blister presents pure {delta} zirconium hydride, with a maximum of 80% for the volume fraction of {delta} hydride at the center of the blister. The texture observed for both phases in the original pressure tube remains essentially unaltered across the hydride blister. A detailed analysis of this texture using well-known parent-precipitate relationships shows that some selective precipitation occurs at {alpha}-Zr grains with their c-axis under a tensile stress, and on grains with grain boundaries favorably aligned for hydride nucleation.

36 MATERIALS SCIENCE↗

Texture Analysis of Inconel 718 with Different Modes During Single-Track Laser Surface Re-Melting

An in-depth understanding of the texture formation in melt pools allows for the modification of the surface layer microstructure and corresponding material properties, providing an opportunity to integrate laser surface re-melting into metal additive manufacturing. This study investigates crystallographic texture formation at different cooling rates in single melting tracks on the Inconel 718 (IN718) plate produced by laser surface re-melting. The cooling rate varies from 2.31 × 10 5 °C/s to 9.56 × 10 5 °C/s with the increase in scanning rates from 400 mm/s to 1200 mm/s, measured by recently developed real-time temperature monitoring of melt pools. Columnar grains are dominant, with distinct crystallographic textures forming in the melt pools. At a slower scanning speed, the keyhole mode shows three different textures forming at different depths (crystallographically layered structure), while, at a faster scanning speed, the conduction mode shows only random grain orientation. There are no pores/voids detected, and the columnar grain morphology and columnar grain width (8.6 μm to 12.4 μm) follow the analysis framework in terms of thermal gradient and solidification rate analysis. This implies that laser surface re-melting provides the potential to modify the surface structure from a random grain orientation to a crystallographically layered structure.

36 MATERIALS SCIENCE↗

TU-D-207B-03: Early Assessment of Response to Chemoradiotherapy Based On Textural Analysis of Pre and Mid-Treatment FDG-PET Image in Locally Advanced Head and Neck Cancer

Purpose: To evaluate whether tumor textural features extracted from both pre- and mid-treatment FDG-PET images predict early response to chemoradiotherapy in locally advanced head and neck cancer, and investigate whether they provide complementary value to conventional volume-based measurements. Methods: Ninety-four patients with locally advanced head and neck cancers were retrospectively studied. All patients received definitive chemoradiotherapy and underwent FDG-PET planning scans both before and during treatment. Within the primary tumor we extracted 6 textural features based on gray-level co-occurrence matrices (GLCM): entropy, dissimilarity, contrast, correlation, energy, and homogeneity. These image features were evaluated for their predictive power of treatment response to chemoradiotherapy in terms of local recurrence free survival (LRFS) and progression free survival (PFS). Logrank test were used to assess the statistical significance of the stratification between low- and high-risk groups. P-values were adjusted for multiple comparisons by the false discovery rate (FDR) method. Results: All six textural features extracted from pre-treatment PET images significantly differentiated low- and high-risk patient groups for LRFS (P=0.011–0.038) and PFS (P=0.029–0.034). On the other hand, none of the textural features on mid-treatment PET images was statistically significant in stratifying LRFS (P=0.212–0.445) or PFS (P=0.168–0.299). An imaging signature that combines textural feature (GLCM homogeneity) and metabolic tumor volume showed an improved performance for predicting LRFS (hazard ratio: 22.8, P<0.0001) and PFS (hazard ratio: 13.9, P=0.0005) in leave-one-out cross validation. Intra-tumor heterogeneity measured by textural features was significantly lower in mid-treatment PET images than in pre-treatment PET images (T-test: P<1.4e-6). Conclusion: Tumor textural features on pretreatment FDG-PET images are predictive for response to chemoradiotherapy in locally advanced head and neck cancer. The complementary information offered by textural features improves patient stratification and may potentially aid in personalized risk-adaptive therapy.

60 APPLIED LIFE SCIENCES↗

TU-D-207B-05: Intra-Tumor Partitioning and Texture Analysis of DCE-MRI Identifies Relevant Tumor Subregions to Predict Early Pathological Response of Breast Cancer to Neoadjuvant Chemotherapy

Purpose: To predict early pathological response of breast cancer to neoadjuvant chemotherapy (NAC) based on quantitative, multi-region analysis of dynamic contrast enhancement magnetic resonance imaging (DCE-MRI). Methods: In this institution review board-approved study, 35 patients diagnosed with stage II/III breast cancer were retrospectively investigated using DCE-MR images acquired before and after the first cycle of NAC. First, principal component analysis (PCA) was used to reduce the dimensionality of the DCE-MRI data with a high-temporal resolution. We then partitioned the whole tumor into multiple subregions using k-means clustering based on the PCA-defined eigenmaps. Within each tumor subregion, we extracted four quantitative Haralick texture features based on the gray-level co-occurrence matrix (GLCM). The change in texture features in each tumor subregion between pre- and during-NAC was used to predict pathological complete response after NAC. Results: Three tumor subregions were identified through clustering, each with distinct enhancement characteristics. In univariate analysis, all imaging predictors except one extracted from the tumor subregion associated with fast wash-out were statistically significant (p< 0.05) after correcting for multiple testing, with area under the ROC curve or AUCs between 0.75 and 0.80. In multivariate analysis, the proposed imaging predictors achieved an AUC of 0.79 (p = 0.002) in leave-one-out cross validation. This improved upon conventional imaging predictors such as tumor volume (AUC=0.53) and texture features based on whole-tumor analysis (AUC=0.65). Conclusion: The heterogeneity of the tumor subregion associated with fast wash-out on DCE-MRI predicted early pathological response to neoadjuvant chemotherapy in breast cancer.

60 APPLIED LIFE SCIENCES↗

Texture Analysis for Enhancement of R-value in Asymmetrically Rolled Al Alloy Sheet

When Al alloy sheet is reduced in thickness by 84% with asymmetric rolling and heat treatment, this sheet simultaneously develops a {001}〈110〉 texture, which decreases the R-value, and a 〈111〉//normal direction (ND) texture, which enhances the R-value. To control the intensities of these {001}〈110〉 and 〈111〉//ND texture components, an 84% heavy asymmetrically rolled and heat-treated AA1050 Al alloy sheet was 20% light asymmetrically rolled and heat-treated at 500 °C for 1 h. This process increased the amount of 〈111〉//ND texture component and reduced the amount of the {001}〈110〉 texture component, resulting in an R-bar -value of 1.3. This was 2.13 times higher than the R-bar -value of 0.61 obtained for the initial specimen that had {001}〈100〉 component.

36 MATERIALS SCIENCE↗

Equal channel angular extrusion for bulk processing of Fe–Co–2V soft magnetic alloys, part II: Texture analysis and magnetic properties

In Part I, equal channel angular extrusion (ECAE) was demonstrated as a novel, simple-shear deformation process for producing bulk forms of the low ductility Fe–Co–2V (Hiperco 50A®) soft ferromagnetic alloy with refined grain sizes. Microstructures and mechanical properties were discussed. In this Part II contribution, the crystallographic textures and quasi-static magnetic properties of ECAE-processed Hiperco were characterized. The textures were of a simple-shear character defined by partial {110} and <111> fibers inclined relative to the extrusion direction, in agreement with the expectations for simple-shear deformation textures of BCC metals. These textures were observed throughout all processing conditions and only slightly reduced in intensity by subsequent recrystallization heat treatments. Characterization of the magnetic properties revealed a lower coercivity and higher permeability for ECAE-processed Hiperco specimens relative to the conventionally processed and annealed Hiperco bar. In conclusion, the effects of the resultant microstructure and texture on the coercivity and permeability magnetic properties are discussed.

36 MATERIALS SCIENCE↗

Texture Analysis of Polycrystalline Vaterite Spherulites from Lake Sturgeon Otoliths

Fish otoliths, or ear bones, are comprised of the CaCO 3 polymorphs (aragonite, calcite and vaterite), which can occur either alone or in combination. The polymorph phase abundance in an otolith depends on, as yet, unexplained genetic and environmental factors. Most fish otoliths are comprised of the densest CaCO 3 polymorph, aragonite. Sturgeon otoliths, on the other hand, contain significant amounts of the rare and the structurally enigmatic polymorph, vaterite. Sturgeon otoliths are frequently comprised of agglomerations of small microcrystalline vaterite spherulites (<300 μm in diameter), that range in shape from nearly perfect spheres to oblate spheroids. These spherulites are similar to the synthetic vaterite microspheres employed in laser trapping applications. Vaterite spherulites from both hatchery-reared (juvenile) and wild (adult) Lake Sturgeon exhibit extreme crystallographic texture as evidenced by X-ray diffraction patterns and their reconstructed pole-figures determined here. The vaterite crystallites making up the spherulites have excellent registry in both the axial and equatorial directions. Whether synthesized or natural, the texture manifested in these spherulites suggests that vaterite nucleates and grows similarly in vivo otolith formation as well as from laboratory synthesis. The uniaxial optical character of the vaterite spherulites, confirmed by these diffraction experiments and combined with their large birefringence, makes them well suited for laser trapping applications.

36 MATERIALS SCIENCE↗