Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal blocking filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

44 records · Page 3

An X-Band Mixer Engineered for 77 K Operation

An X-band Si-diode singly balanced mixer developed specifically for cryogenic operation is presented. In order to reduce thermal demands on a mechanical cooler, the mixer was designed to operate with a minimum of local oscillator (LO) power. That is, since the LO had to be cooled to reduce phase noise, it was desirable to minimize the LO drive. Novel embedding circuit strategy was responsible for nearly theoretical performance. The signal-matching circuit simultaneously provided a reactive termination to the image, sum, and first, second, and third LO harmonic frequencies. A conversion loss of 3.2 dB at 77 K with an LO drive of +1 dBm was measured. This loss included IF filter, dc block, and hybrid coupler losses. Mixer conversion loss is shown to be consistent with the theoretical performance limit expected from the intrinsic diode. The relationship among junction capacitance, flat-band potential, and conversion loss is examined.

Romanofsky, Robert R.↗

Modeling Contamination Migration on the Chandra X-ray Observatory II

During its first 14 years of operation, the cold (about ‐60degC) optical blocking filter of the Advanced CCD Imaging Spectrometer (ACIS), aboard the Chandra X‐ray Observatory, has accumulated a growing layer of molecular contamination that attenuates low‐energy x rays. Over the past few years, the accumulation rate, spatial distribution, and composition may have changed, perhaps partially related to changes in the operating temperature of the ACIS housing. This evolution of the accumulation of the molecular contamination has motivated further analysis of contamination migration on the Chandra X‐ray Observatory, particularly within and near the ACIS cavity. To this end, the current study employs a higher‐fidelity geometric model of the ACIS cavity, detailed thermal modeling based upon monitored temperature data, and an accordingly refined model of the molecular transport.

O'Dell, Stephen L.↗

Modeling Contamination Migration on the Chandra X-ray Observatory II

During its first 14 years of operation, the cold (about ‐60degC) optical blocking filter of the Advanced CCD Imaging Spectrometer (ACIS), aboard the Chandra X‐ray Observatory, has accumulated a growing layer of molecular contamination that attenuates low‐energy x rays. Over the past few years, the accumulation rate, spatial distribution, and composition may have changed, perhaps partially related to changes in the operating temperature of the ACIS housing. This evolution of the accumulation of the molecular contamination has motivated further analysis of contamination migration on the Chandra X‐ray Observatory, particularly within and near the ACIS cavity. To this end, the current study employs a higher‐fidelity geometric model of the ACIS cavity, detailed thermal modeling based upon monitored temperature data, and an accordingly refined model of the molecular transport.

O'Dell, Steve↗

One Year of Rayleigh Lidar Measurements at Toronto

The Rayleigh lidar technique is being used at York University to study middle atmospheric thermal structure with particular emphasis on the properties and influence of internal gravity waves. These measurements are now carried out on a routine basis (every clear night) in order to determine seasonal variability and, eventually, long term trends. The transmitter consists of a doubled Nd:YAG laser with an output of 0.4 Joules per pulse at 20Hz (8 Watts) which is expanded to obtain a divergence of 0.4 milliradians. Backscattered photons are collected by a half meter cassegrain telescope, filtered to a bandwidth of 1nm, detected by a PMT, and counted with a multi-channel scaling averager. Strong backscatter from lower altitudes is blocked using a rotating chopper (25000rpm) which triggers the laser. The range gate and hardware averaging interval are variable but typically 300m and 5 minutes. Relative density profiles are obtained by simply normalizing to a model (eg. CIRA) at some altitude. Absolute temperature is derived using the hydrostatic equation, ideal gas law, and a model pressure value at the altitude where the photocount statistical uncertainty is about 15 percent - typically 90km for the entire night's average. The lower limit is currently about 30-35km due the presence aerosol from the volcanic eruption of Mt. Pinatubo.

Whiteway, James A.↗

NASA Tech Briefs, December 2003

Topics covered include: Organic/Inorganic Hybrid Polymer/Clay Nanocomposites; Less-Toxic Coatings for Inhibiting Corrosion of Aluminum; Liquid Coatings for Reducing Corrosion of Steel in Concrete; Processable Polyimides Containing APB and Reactive End Caps; Rod/Coil Block Copolyimides for Ion-Conducting Membranes; Techniques for Characterizing Microwave Printed Antennas; Cylindrical Antenna With Partly Adaptive Phased-Array Feed; Command Interface ASIC - Analog Interface ASIC Chip Set; Predicting Accumulations of Ice on Aerodynamic Surfaces; Analyzing Aeroelasticity in Turbomachines; Software for Allocating Resources in the Deep Space Network; Expert Seeker; High-Speed Recording of Test Data on Hard Disks; Functionally Graded Nanophase Beryllium/Carbon Composites; Thin Thermal-Insulation Blankets for Very High Temperatures; Aerostructures Test Wing; Flight-Test Evaluation of Flutter-Prediction Methods; Piezoelectrically Actuated Microvalve for Liquid Effluents; Larger-Stroke Piezoelectrically Actuated Microvalve; Innovative, High-Pressure, Cryogenic Control Valve: Short Face-to-Face, Reduced Cost; Safer Roadside Crash Walls Would Limit Deceleration; Improved Interactive Medical-Imaging System; Scanning Microscopes Using X Rays and Microchannels; Slotting Fins of Heat Exchangers to Provide Thermal Breaks; Methane Clathrate Hydrate Prospecting; Automated Monitoring with a BSP Fault-Detection Test; Automated Monitoring with a BCP Fault-Decision Test; Vector-Ordering Filter Procedure for Data Reduction; Remote Sensing and Information Technology for Large Farms; Developments at the Advanced Design Technologies Testbed; Spore-Forming Bacteria that Resist Sterilization; and Acoustical Applications of the HHT Method.

Source record↗

Re-Configurable Electronics Characterization under Extreme Thermal Environment

The need for reconfigurable electronics is driven by requirements to survive longer missions and harsher environments. It is possible to compensate for degradations in Extreme Environments (EE). EE has effect on electronics: circuits are designed to exploit device characteristics and when a certain temperature or radiation range is exceeded the circuit function gradually degrades. It is possible to employ Hardening by reconfiguration (HBR) to mitigate drifts, degradation, or damage on electronic devices in EE by using reconfigurable devices and an adaptive self-reconfiguration of circuit topology. In this manner degraded components can be salvaged, and completely damaged components can be bypassed. The challenge of conventional design is replaced with that of designing a recover process that automatically performs the (re) design in place of the designer. The objective of testing a Digital Signal Processor (DSP) under the extreme temperatures was to determine the lowest temperature at which the DAP can operate. The objective of testing a Xilinx VirtexII Pro FPGA board was to initially find our whether the evaluation board and the FPGA would survive and continue at temperature ranges from -180 C, and 120 C. The Virtex II functioned correctly at the temperatures tested. The next test was done on the GM-C filter building block using the same temperature range as the Virtex II. The current lower and upper limits were shown to be reduced as the temperature gets lower. The device function can be recovered by increasing the Vb from .08V to .85V. The negative and positive saturation voltages increases as the temperature gets higher. The function of the device can be recovered by decreasing the Vb from .8V to around .75V. The next test was performed to test the recovery of the GmC low pass filter through Vb in a filter circuit. The test indicate that bias voltage control adjustment is an efficient mechanism for circuit recovery at extreme temperatures.

reliability↗

Sub-1K Cold-Electron Quantum Well Switching at Room Temperature

Quantum states can provide means to systematically manipulate the transport of electrons. Here, in this study, we present electron transport across quasi-bound states of two heterogeneous quantum wells (QWs), where the transport of thermally excited electrons is blocked or enabled depending on the relative positions of the two quasi-bound states, with an abrupt current onset occurring when the two QW states align. The QW switch comprises a source (Cr), QW1 (Cr 2 O 3 ), QW2 (SnO x , x < 2), a tunneling barrier (SiO 2 ), and a drain (Si), where the effective electron mass of QW1 (m* QW1 ) is selected to be larger than QW2 (m* QW2 ). The current-voltage (I-V) measurements of the fabricated devices show abrupt current onsets, with the current transition occurring within 0.25 mV, corresponding to an effective electron temperature of 0.8 K at room temperature. Since transistor power consumption is fundamentally tied to effective electron temperature, this sub-1K cold-electron QW switching holds promise for highly energy-efficient computing.

Fermi−Dirac thermal smearing↗

Fast Offset Laser Phase-Locking System

Figure 1 shows a simplified block diagram of an improved optoelectronic system for locking the phase of one laser to that of another laser with an adjustable offset frequency specified by the user. In comparison with prior systems, this system exhibits higher performance (including higher stability) and is much easier to use. The system is based on a field-programmable gate array (FPGA) and operates almost entirely digitally; hence, it is easily adaptable to many different systems. The system achieves phase stability of less than a microcycle. It was developed to satisfy the phase-stability requirement for a planned spaceborne gravitational-wave-detecting heterodyne laser interferometer (LISA). The system has potential terrestrial utility in communications, lidar, and other applications. The present system includes a fast phasemeter that is a companion to the microcycle-accurate one described in High-Accuracy, High-Dynamic-Range Phase-Measurement System (NPO-41927), NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 22. In the present system (as in the previously reported one), beams from the two lasers (here denoted the master and slave lasers) interfere on a photodiode. The heterodyne photodiode output is digitized and fed to the fast phasemeter, which produces suitably conditioned, low-latency analog control signals which lock the phase of the slave laser to that of the master laser. These control signals are used to drive a thermal and a piezoelectric transducer that adjust the frequency and phase of the slave-laser output. The output of the photodiode is a heterodyne signal at the difference between the frequencies of the two lasers. (The difference is currently required to be less than 20 MHz due to the Nyquist limit of the current sampling rate. We foresee few problems in doubling this limit using current equipment.) Within the phasemeter, the photodiode-output signal is digitized to 15 bits at a sampling frequency of 40 MHz by use of the same analog-to-digital converter (ADC) as that of the previously reported phasemeter. The ADC output is passed to the FPGA, wherein the signal is demodulated using a digitally generated oscillator signal at the offset locking frequency specified by the user. The demodulated signal is low-pass filtered, decimated to a sample rate of 1 MHz, then filtered again. The decimated and filtered signal is converted to an analog output by a 1 MHz, 16-bit digital-to-analog converters. After a simple low-pass filter, these analog signals drive the thermal and piezoelectric transducers of the laser.

Shaddock, Daniel↗