Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing error evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design and testing of a phantom and instrumented gynecological applicator based on GaN dosimeter for use in high dose rate brachytherapy quality assurance

Purpose: High dose rate brachytherapy (HDR-BT) is widely used to treat gynecologic, anal, prostate, head, neck, and breast cancers. These treatments are typically administered in large dose per fraction (>5 Gy) and with high-gradient-dose-distributions, with serious consequences in case of a treatment delivery error (e.g., on dwell position and dwell time). Thus, quality assurance (QA) or quality control (QC) should be systematically and independently implemented. This paper describes the design and testing of a phantom and an instrumented gynecological applicator for pretreatment QA and in vivo QC, respectively. Methods: The authors have designed a HDR-BT phantom equipped with four GaN-based dosimeters. The authors have also instrumented a commercial multichannel HDR-BT gynecological applicator by rigid incorporation of four GaN-based dosimeters in four channels. Specific methods based on the four GaN dosimeter responses are proposed for accurate determination of dwell time and dwell position inside phantom or applicator. The phantom and the applicator have been tested for HDR-BT QA in routine over two different periods: 29 and 15 days, respectively. Measurements in dwell position and time are compared to the treatment plan. A modified position–time gamma index is used to monitor the quality of treatment delivery. Results: The HDR-BT phantom and the instrumented applicator have been used to determine more than 900 dwell positions over the different testing periods. The errors between the planned and measured dwell positions are 0.11 ± 0.70 mm (1σ) and 0.01 ± 0.42 mm (1σ), with the phantom and the applicator, respectively. The dwell time errors for these positions do not exhibit significant bias, with a standard deviation of less than 100 ms for both systems. The modified position–time gamma index sets a threshold, determining whether the treatment run passes or fails. The error detectability of their systems has been evaluated through tests on intentionally introduced error protocols. With a detection threshold of 0.7 mm, the error detection rate on dwell position is 22% at 0.5 mm, 96% at 1 mm, and 100% at and beyond 1.5 mm. On dwell time with a dwell time threshold of 0.1 s, it is 90% at 0.2 s and 100% at and beyond 0.3 s. Conclusions: The proposed HDR-BT phantom and instrumented applicator have been tested and their main characteristics have been evaluated. These systems perform unsupervised measurements and analysis without prior treatment plan information. They allow independent verification of dwell position and time with accuracy of measurements comparable with other similar systems reported in the literature.

60 APPLIED LIFE SCIENCES↗

Performance of a hard X-ray split-and-delay optical system with a wavefront division

The performance of a hard X-ray split-and-delay optical (SDO) system with a wavefront division scheme was investigated at the hard X-ray free-electron laser facility SACLA. For the wavefront division, beam splitters made of edge-polished perfect Si(220) crystals were employed. We characterized the beam properties of the SDO system, and investigated its capabilities for beam manipulation and diagnostics. First, it was confirmed that shot-to-shot non-invasive diagnostics of pulse energies for both branches in the SDO system was feasible. Second, nearly ideal and identical focal profiles for both branches were obtained with a spot size of ~1.5 µm in full width at half-maximum. Third, a spatial overlap of the two focused beams with a sub-µm accuracy was achieved by fine tuning of the SDO system. Finally, a reliable tunability of the delay time between two pulses was confirmed. The time interval was measured with an X-ray streak camera by changing the path length of the variable-delay branch. As a result, errors from the fitted line were evaluated to be as small as ±0.4 ps over a time range of 60 ps.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of Linear Accelerator Gating With Real-Time Electromagnetic Tracking

Purpose: Intrafraction organ motion can produce dosimetric errors in radiotherapy. Commonly, the linear accelerator is gated using real-time breathing phase obtained by way of external sensors. However, the external anatomy does not always correlate well with the internal position. We examined a beam gating technique using signals from implanted wireless transponders that provided real-time feedback on the tumor location without an imaging dose to the patient. Methods and Materials: An interface was developed between Calypso Medical's four-dimensional electromagnetic tracking system and a Varian Trilogy linear accelerator. A film phantom was mounted on a motion platform programmed with lung motion trajectories. Deliveries were performed when the beam was gated according to the signal from the wireless transponders. The dosimetric advantages of beam gating and the system latencies were quantified. Results: Beam gating using on internal position monitoring provided up to a twofold increase in the dose gradients. The percentage of points failing to be within {+-}10 cGy of the planned dose (maximal dose, {approx}200 cGy) was 3.4% for gating and 32.1% for no intervention in the presence of motion. The mean latencies between the transponder position and linear accelerator modulation were 75.0 {+-}12.7 ms for beam on and 65.1 {+-} 12.9 ms for beam off. Conclusion: We have presented the results from a novel method for gating the linear accelerator using trackable wireless internal fiducial markers without the use of ionizing radiation for imaging. The latencies observed were suitable for gating using electromagnetic fiducial markers, which results in dosimetric improvements for irradiation in the presence of motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-201-03: Automation of High Dose Rate Brachytherapy Quality Assurance: Development of a Radioluminescent Detection System for Simultaneous Detection of Activity, Timing, and Positioning

Purpose: Accuracy of positioning, timing and activity is of critical importance for High Dose Rate (HDR) brachytherapy delivery. Respective measurements via film autoradiography, stop-watches and well chambers can be cumbersome, crude or lack dynamic source evaluation capabilities. To address such limitations, a single device radioluminescent detection system enabling automated real-time quantification of activity, position and timing accuracy is presented and experimentally evaluated. Methods: A radioluminescent sheet was fabricated by mixing Gd?O?S:Tb with PDMS and incorporated into a 3D printed device where it was fixated below a CMOS digital camera. An Ir-192 HDR source (VS2000, VariSource iX) with an effective active length of 5 mm was introduced using a 17-gauge stainless steel needle below the sheet. Pixel intensity values for determining activity were taken from an ROI centered on the source location. A calibration curve relating intensity values to activity was generated and used to evaluate automated activity determination with data gathered over 6 weeks. Positioning measurements were performed by integrating images for an entire delivery and fitting peaks to the resulting profile. Timing measurements were performed by evaluating source location and timestamps from individual images. Results: Average predicted activity error over 6 weeks was .35 ± .5%. The distance between four dwell positions was determined by the automated system to be 1.99 ± .02 cm. The result from autoradiography was 2.00 ± .03 cm. The system achieved a time resolution of 10 msec and determined the dwell time to be 1.01 sec ± .02 sec. Conclusion: The system was able to successfully perform automated detection of activity, positioning and timing concurrently under a single setup. Relative to radiochromic and radiographic film-based autoradiography, which can only provide a static evaluation positioning, optical detection of temporary radiation induced luminescence enables dynamic detection of position enabling automated quantification of timing with millisecond accuracy.

60 APPLIED LIFE SCIENCES↗

Chemometrics and Experimental Design for the Quantification of Nitrate Salts in Nitric Acid: Near-Infrared Spectroscopy Absorption Analysis

Implementing remote, real-time spectroscopic monitoring of radiochemical processing streams in hot cell environments requires efficiency and simplicity. The success of optical spectroscopy for the quantification of species in chemical systems highly depends on representative training sets and suitable validation sets. Selecting a training set (i.e., calibration standards) to build multivariate regression models is both time- and resource-consuming using standard one-factor-at-a-time approaches. This study describes the use of experimental design to generate spectral training sets and a validation set for the quantification of sodium nitrate (0–1 M) and nitric acid (0.1–10 M) using the near-infrared water band centered at 1440 nm. Partial least squares regression models were built from training sets generated by both D- and I-optimal experimental designs and a one-factor-at-a-time approach. The prediction performance of each model was evaluated by comparing the bias and standard error of prediction for statistical significance. D- and I-optimal designs reduced the number of samples required to build regression models compared with one-factor-at-a-time while also improving performance. Models must be confirmed against a validation sample set when minimizing the number of samples in the training set. The D-optimal design performed the best when considering both performance and efficiency by improving predictive capability and reducing number of samples in the training set by 64% compared with the one-factor-at-a-time approach. The experimental design approach objectively selects calibration and validation spectral data sets based on statistical criterion to optimize performance and minimize resources.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Testing contamination source identification methods for water distribution networks

In the event of contamination in a water distribution network (WDN), source identification (SI) methods that analyze sensor data can be used to identify the source location(s). Knowledge of the source location and characteristics are important to inform contamination control and cleanup operations. Various SI strategies that have been developed by researchers differ in their underlying assumptions and solution techniques. The following manuscript presents a systematic procedure for testing and evaluating SI methods. The performance of these SI methods is affected by various factors including the size of WDN model, measurement error, modeling error, time and number of contaminant injections, and time and number of measurements. This paper includes test cases that vary these factors and evaluates three SI methods on the basis of accuracy and specificity. The tests are used to review and compare these different SI methods, highlighting their strengths in handling various identification scenarios. These SI methods and a testing framework that includes the test cases and analysis tools presented in this paper have been integrated into EPA’s Water Security Toolkit (WST), a suite of software tools to help researchers and others in the water industry evaluate and plan various response strategies in case of a contamination incident. Lastly, a set of recommendations are made for users to consider when working with different categories of SI methods.

54 ENVIRONMENTAL SCIENCES↗

Predicting Geometric Influences in Metal Additive Manufacturing

Metal additive manufacturing (AM) has evolved from scientific curiosity to a potential paradigm shift in materials manufacturing owing to its ability to control microstructure and fabricate complex geometries. However, geometry, often ignored as a variable, can have a significant impact on microstructure evolution, thereby indirectly limiting the design flexibility offered by AM. Currently, the process of retaining microstructure with changing geometry relies on trial and error-based processing followed by microstructural evaluation that places significant demands on time and costs associated with experimentation and characterization. We demonstrate herein that lightweight thermal models can be effectively used to predict microstructural changes with geometry. These models can in turn be used as precursors to developing geometry independent scan strategies and achieve microstructure control in various alloy systems. Even if the thermal signatures predicted by the model are not accurate, scan strategies can be developed to mimic the thermal conditions during initial process development. We present a case study on one of the most studied AM alloys: Ti-6Al-4V.

36 MATERIALS SCIENCE↗

Denoising Seismograms in the Time Domain Using a Deep Learning Model

Deep learning has emerged as a transformative tool for enhancing the extraction of reliable information from seismograms, addressing the increasing demand for precise and efficient seismic data analysis. We introduce an innovative encoder–decoder deep learning model, named WaveDenoiser, designed for noise reduction in the time domain, thereby eliminating the need for spectrogram computations that have been used for existing deep learning tools and significantly improving processing speed. Utilizing the benchmark dataset that is Stanford Earthquake Dataset, we developed three models of varying sizes: base, medium, and large. Notably, the large (referred to as WaveDenoiser) model demonstrated superior performance, achieving a median signal‐to‐noise ratio improvement of 8.8 dB on in‐distribution unseen data (in the same geographic region) and 7.7 dB on out‐distribution unseen data (in a new geographic region), outpacing both the base and medium models. Further evaluation of the WaveDenoiser model revealed a reduction in median arrival‐time errors by 0.02 s for P waves and 0.01 s for S waves when processing waveforms prior to phase picking using PhaseNet on in‐distribution unseen data. When tested on out‐distribution unseen data, the model also effectively reduced the P‐wave median arrival‐time error by 0.02 and 0.01 s in median arrival‐time error for S waves. Importantly, the application of WaveDenoiser resulted in a significant reduction of phase picking outliers by 1.1% to 3.6% for both P and S waves. In addition, we achieved over five times acceleration in processing speed compared with the seisBench implementation of DeepDenoiser. Our findings underscore the potential of WaveDenoiser as a powerful tool for improving seismic data analysis and processing efficiency.

P-waves↗

Fast and self-learning indoor airflow simulation based on in situ adaptive tabulation

Fast simulation for stratified indoor airflow distributions is desired for various applications, such as design of advanced indoor environments, emergency management, and coupled annual energy simulation for buildings with stratified air distributions. Reduced order models trained by pre-computed computational fluid dynamics results are fast, but their prediction may be inaccurate when applied for conditions outside the training domain. To overcome this limitation, we propose in this paper a fast and self-learning model based on an in situ adaptive tabulation (ISAT) algorithm, which is trained by a fast fluid dynamics (FFD) model as an example. The idea is that the ISAT will retrieve the solutions from an existing data set if the estimated prediction error is within a pre-defined tolerance. Otherwise, the ISAT will execute the FFD simulation, which is accelerated by running in parallel on a graphics processing unit, for a full-scale simulation. This paper systematically investigates the feasibility of the ISAT for indoor airflow simulations by presenting the ISAT-FFD implementation alongside results related to its overall performance. Using a stratified indoor airflow as an example, we evaluated how the training time of ISAT was impacted by four factors (training methods, error tolerances, number of inputs, and number of outputs). Then we demonstrated that a trained ISAT model can predict the key information for inputs both inside and outside the training domain. The ISAT was able to answer query points both inside and close to training domain using retrieve actions within a time less than 0.001 s for each query. In conclusion, we provided suggestions for using the ISAT for building applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimating the Contributions to Human Error Probability from the Convolution of the Distribution of Time Available and Time Required

As part of their duties, Human Reliability Analysis must often evaluate if crews in nuclear power plants (NPPs) can complete tasks associated with a human-failure event within time limits. For example, the time required in NPP scenarios is determined by systematic and structured walkthroughs, feasibility studies, recorded times from training exercises, and interviews with experienced operators and experts. Typically, a point estimate is derived for the estimate (mean, maximum, or 95th percentile of time required). Using point-estimate values can mask the risk associated with variability among crews, plant conditions and set-up, environmental conditions, and other impact factors under which these actions are executed. While point estimates for time required and time available have served the industry well, without considering the uncertainty they could lead to biased understanding about the risk. The Integrated Human Event Analysis System - General Methodology (IDHEAS-G) model (developed by the US Nuclear Regulatory Commission, NRC) for human error probability calculates human error probability by summing two probabilities: insufficient time and cognitive error. As such, the model takes a more holistic approach by considering the full distributions for time required and time available to calculate the human error probability because the time available to complete the task is insufficient. In this study, we expand on the work of the NRC and discuss methods for estimating these time considerations. For example, for the time required, the impact of Performance Influencing Factors (PIFs) on the distribution was divided into impacts that are aleatory in nature, such as crew-to-crew variability, and those that are epistemic (i.e., the PIFs). Starting with the factors that introduce aleatory uncertainty, a first-order distribution was developed from a large set of time required (i.e., NPP task completion times) data for the range of operator actions that occur in the NPP control room under simulated accident conditions. The first-order distribution can then be adjusted to account for epistemic uncertainty using research associated with the impact of applicable PIFs on the time required. We also develop guidance for analysts to address the probability distributions for the time available. The guidance we developed on how to estimate time required and time available distributions is based on the identification of pertinent research and data, data analyses, and expert knowledge elicitation.

human error probability, human performance, time e↗

Computer–Based Procedures for Nuclear Power Plant Field Workers: Preliminary Results from Two Evaluation Studies

The Idaho National Laboratory and participants from the U.S. nuclear industry are collaborating on a research effort aimed to augment the existing guidance on computer-based procedure (CBP) design with specific guidance on how to design CBP user interfaces such that they support procedure execution in ways that exceed the capabilities of paper-based procedures (PBPs) without introducing new errors. Researchers are employing an iterative process where the human factors issues and interface design principles related to CBP usage are systematically addressed and evaluated in realistic settings. This paper describes the process of developing a CBP prototype and the two studies conducted to evaluate the prototype. The results indicate that CBPs may improve performance by reducing errors, but may increase the time it takes to complete procedural tasks.

99 GENERAL AND MISCELLANEOUS↗

Offline Maximizing Minimally Invasive Proper Orthogonal Decomposition for Reduced-Order Modeling of S n Radiation Transport

Deterministic solutions to the Sn radiation transport equation can be computationally expensive to calculate. Reduced-order modeling enables efficient approximation of the full-order model (FOM) solution. We propose a novel method for constructing reduced-order models (ROMs) of the S n radiation transport equation, offline maximizing minimally invasive (OMMI) proper orthogonal decomposition (POD). POD uses the method of snapshots to create a reduced-order basis for constructing an ROM. Minimally invasive POD leverages the sweep infrastructure existing in deterministic transport codes to create a POD-based ROM, even when infeasible by traditional methods. Offline maximizing minimally invasive proper orthogonal decomposition (OMMI-POD) extends minimally invasive POD by performing sweeps offline, therefore maximizing the potential speedup. OMMI-POD does so by creating a library of reduced systems from a training set. This library of reduced systems is then interpolated to provide a rapid approximate solution of the S n radiation transport equation. The model is evaluated on a set of test problems, achieving a low error with a 466 times speedup over the FOM. Also presented is a study of the effect of sampling method on the performance of OMMI-POD, specifically comparing naive uniform sampling to the more accurate and computationally expensive greedy sampling.

97 MATHEMATICS AND COMPUTING↗

Predicting initial trans-membrane pressure across cycles in the ultrafiltration process using random forest

With growing freshwater scarcity, direct potable reuse (DPR) systems that reclaim wastewater for drinking are becoming increasingly important for sustainable water supply. Reliable operation requires minimizing downtime in ultrafiltration (UF) units, where membrane fouling leads to elevated trans-membrane pressure (TMP). This study develops data-driven regression models based on random forest (RF) and autoregressive (AR) approaches to forecast the initial TMP at the start of each UF filtration cycle in a pilot-scale DPR system. The RF model consistently outperforms baseline methods, including historical mean, last observation carried forward, and AR models, across multiple forecast horizons, achieving the lowest root mean square error. To evaluate how different classes of process variables contribute to TMP dynamics over time, we examine the feature importance of independent input variables across multiple forecast horizons. This analysis provides insight into the temporal relevance of operational and sensor-derived features, guiding control and monitoring strategies. Additionally, the impact of hyperparameter tuning on TMP prediction performance is assessed for both direct and recursive RF modelling approaches. The proposed RF framework establishes a robust foundation for predictive monitoring and real-time optimization of UF operations, supporting sustainable and reliable water reuse.

direct potable reuse↗

Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance, improved software design, and manufacturer–user training may help mitigate these events.

07 ISOTOPE AND RADIATION SOURCES↗

MO-G-BRE-06: Metrics of Success: Measuring Participation and Attitudes Related to Near-Miss Incident Learning Systems

Purpose: Interest in incident learning systems (ILS) for improving safety and quality in radiation oncology is growing, as evidenced by the upcoming release of the national ILS. However, an institution implementing such a system would benefit from quantitative metrics to evaluate performance and impact. We developed metrics to measure volume of reporting, severity of reported incidents, and changes in staff attitudes over time from implementation of our institutional ILS. Methods: We analyzed 2023 incidents from our departmental ILS from 2/2012–2/2014. Incidents were prospectively assigned a near-miss severity index (NMSI) at multidisciplinary review to evaluate the potential for error ranging from 0 to 4 (no harm to critical). Total incidents reported, unique users reporting, and average NMSI were evaluated over time. Additionally, departmental safety attitudes were assessed through a 26 point survey adapted from the AHRQ Hospital Survey on Patient Safety Culture before, 12 months, and 24 months after implementation of the incident learning system. Results: Participation in the ILS increased as demonstrated by total reports (approximately 2.12 additional reports/month) and unique users reporting (0.51 additional users reporting/month). Also, the average NMSI of reports trended lower over time, significantly decreasing after 12 months of reporting (p<0.001) but with no significant change at months 18 or 24. In survey data significant improvements were noted in many dimensions, including perceived barriers to reporting incidents such as concern of embarrassment (37% to 18%; p=0.02) as well as knowledge of what incidents to report, how to report them, and confidence that these reports were used to improve safety processes. Conclusion: Over a two-year period, our departmental ILS was used more frequently, incidents became less severe, and staff confidence in the system improved. The metrics used here may be useful for other institutions seeking to create or evaluate their own incident learning systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

On The Jacobian of the ECEF J2 Gravitation Model

An Earth-centered, Earth-fixed (ECEF) inertial navigation system must compute the Jacobian of its employed gravitation model with respect to position while time-propagating the error covariance of the system. One commonly used gravitation model is the ‘J2 model’ which is a second-order truncation of the Earth’s spherical harmonic gravitation model. The J2 model is popular because it can quickly and efficiently be evaluated, and the truncation error is small: The ‘J3 term’ --- the third term in the spherical harmonic expansion --- is approximately 1000 times smaller than the J2 term.

42 ENGINEERING↗

MO-C-17A-04: Forecasting Longitudinal Changes in Oropharyngeal Tumor Morphology Throughout the Course of Head and Neck Radiation Therapy

Purpose: To generate, evaluate, and compare models that predict longitudinal changes in tumor morphology throughout the course of radiation therapy. Methods: Two morphology feature vectors were used to describe the size, shape, and position of 35 oropharyngeal GTVs at each treatment fraction during intensity-modulated radiation therapy. The feature vectors comprised the coordinates of the GTV centroids and one of two shape descriptors. One shape descriptor was based on radial distances between the GTV centroid and 614 GTV surface landmarks. The other was based on a spherical harmonic decomposition of these distances. Feature vectors over the course of therapy were described using static, linear, and mean models. The error of these models in forecasting GTV morphology was evaluated with leave-one-out cross-validation, and their accuracy was compared using Wilcoxon signed-rank tests. The effect of adjusting model parameters at 1, 2, 3, or 5 time points (adjustment points) was also evaluated. Results: The addition of a single adjustment point to the static model decreased the median error in forecasting the position of GTV surface landmarks by 1.2 mm (p<0.001). Additional adjustment points further decreased forecast error by about 0.4 mm each. The linear model decreased forecast error compared to the static model for feature vectors based on both shape descriptors (0.2 mm), while the mean model did so only for those based on the inter-landmark distances (0.2 mm). The decrease in forecast error due to adding adjustment points was greater than that due to model selection. Both effects diminished with subsequent adjustment points. Conclusion: Models of tumor morphology that include information from prior patients and/or prior treatment fractions are able to predict the tumor surface at each treatment fraction during radiation therapy. The predicted tumor morphology can be compared with patient anatomy or dose distributions, opening the possibility of anticipatory re-planning. American Legion Auxiliary Fellowship; The University of Texas Graduate School of Biomedical Sciences at Houston.

60 APPLIED LIFE SCIENCES↗

The potential of positron emission tomography for intratreatment dynamic lung tumor tracking: A phantom study

Purpose: This study aims to evaluate the potential and feasibility of positron emission tomography for dynamic lung tumor tracking during radiation treatment. The authors propose a center of mass (CoM) tumor tracking algorithm using gated-PET images combined with a respiratory monitor and investigate the geometric accuracy of the proposed algorithm. Methods: The proposed PET dynamic lung tumor tracking algorithm estimated the target position information through the CoM of the segmented target volume on gated PET images reconstructed from accumulated coincidence events. The information was continuously updated throughout a scan based on the assumption that real-time processing was supported (actual processing time at each frame ≈10 s). External respiratory motion and list-mode PET data were acquired from a phantom programmed to move with measured respiratory traces (external respiratory motion and internal target motion) from human subjects, for which the ground truth target position was known as a function of time. The phantom was cylindrical with six hollow sphere targets (10, 13, 17, 22, 28, and 37 mm in diameter). The measured respiratory traces consisted of two sets: (1) 1D-measured motion from ten healthy volunteers and (2) 3D-measured motion from four lung cancer patients. The authors evaluated the geometric accuracy of the proposed algorithm by quantifying estimation errors (Euclidean distance) between the actual motion of targets (1D-motion and 3D-motion traces) and CoM trajectories estimated by the proposed algorithm as a function of time. Results: The time-averaged error of 1D-motion traces over all trajectories of all targets was 1.6 mm. The error trajectories decreased with time as coincidence events were accumulated. The overall error trajectory of 1D-motion traces converged to within 2 mm in approximately 90 s. As expected, more accurate results were obtained for larger targets. For example, for the 37 mm target, the average error over all 1D-motion traces was 1.1 mm; and for the 10 mm target, the average error over all 1D-motion traces was 2.8 mm. The overall time-averaged error of 3D-motion traces was 1.6 mm, which was comparable to that of the 1D-motion traces. There were small variations in the errors between the 3D-motion traces, although the motion trajectories were very different. The accuracy of the estimates was consistent for all targets except for the smallest. Conclusions: The authors developed an algorithm for dynamic lung tumor tracking using list-mode PET data and a respiratory motion signal, and demonstrated proof-of-principle for PET-guided lung tumor tracking. The overall tracking error in phantom studies is less than 2 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗