Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomographic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Utilisation of spatial derivative measurements in circular diffuse optical tomographic imaging to improve image resolution and contrast

The resolution of images recovered using diffuse optical tomography without spatial prior information is inherently limited due to the diffusive nature of light transport in scattering dominated biological tissue. Several studies have previously reported an improvement in depth sensitivity in near infrared spectroscopy by considering the subtraction of two neighbouring measurements. A nearest neighbour, spatial derivative based algorithm is presented, in which the difference between neighbouring source-sharing source – detector pairs is considered for tomographic reconstruction. Using a circular, inward-facing optode geometry, it is shown that deeper abnormalities in oxyhaemoglobin, deoxyhaemoglobin and water can be recovered with better localisation and contrast as compared to reconstructing using absolute values of multi-wavelength data. Relative improvements of up to 25 % in quantitative accuracy of recovered physiological values are demonstrated at better resolution for cancerous tissue in a heterogeneous breast model, when using this proposed spatial derivative based parameter reconstruction. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automated X-Ray Tomographic Defect Analysis in High Density Carbon Capsules

High density carbon capsule ablators are of primary interest for National Ignition Facility experiments. Two of the major contributors to hydrodynamic instabilities in these capsules are voids and high-density inclusions, where the quantity and size of these defects can result in lower yields in inertial confinement fusion. To aid in capsule selection, General Atomics developed a LabVIEW analysis routine to quantify these defects based off a large field of view tomographic dataset and provide insight into the quality of the capsule. Furthermore, this analysis determines if there are large voids or inclusions that may affect shot performance and helps rank which capsules should be used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a tomographic reconstruction method for axisymmetric D α emission profiles in the ITER plasma boundary

A tomographic method for reconstructing the axially symmetric D α emission profile in the ITER scrape-off layer and divertor from D α intensity measurements in the fields of view (FoV) of Vis/IR TV and Divertor Impurity Monitor diagnostics is under development. The method takes into account the strong background signal due to stray light from divertor produced by reflections from the metal wall of the vacuum chamber. The method allows to filter out the reflections in D α signals measured in the main chamber. Here, the accuracy of this method is tested within the framework of a synthetic diagnostic, which uses the Raysect and Cherab numerical codes for ray-tracing simulations. The D α emission profiles, simulated with the SOLPS and OEDGE codes, are used as synthetic experimental data. Uncertainty in light reflection properties of the first wall (FW) is the major factor affecting the accuracy of the D α emission reconstruction. The dependence on the uncertainty in the FW surface roughness and on the ratio of diffusive to specular reflection of the error in recovering useful D α signals (the direct light without reflections) in the FoV of the ITER main chamber H-alpha and Visible Spectroscopy Diagnostic is obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cosmological constraints from the tomographic cross-correlation of DESI Luminous Red Galaxies and Planck CMB lensing

We use luminous red galaxies selected from the imaging surveys that are being used for targeting by the Dark Energy Spectroscopic Instrument (DESI) in combination with CMB lensing maps from the Planck collaboration to probe the amplitude of large-scale structure over 0.4 ≤ z ≤ 1. Our galaxy sample, with an angular number density of approximately 500 deg -2 over 18,000 sq.deg., is divided into 4 tomographic bins by photometric redshift and the redshift distributions are calibrated using spectroscopy from DESI. We fit the galaxy autospectra and galaxy-convergence cross-spectra using models based on cosmological perturbation theory, restricting to large scales that are expected to be well described by such models. Within the context of ΛCDM, combining all 4 samples and using priors on the background cosmology from supernova and baryon acoustic oscillation measurements, we find S 8 = σ 8 (Ωm/0.3) 0.5 = 0.73 ± 0.03. This result is lower than the prediction of the ΛCDM model conditioned on the Planck data. Furthermore, our data prefer a slower growth of structure at low redshift than the model predictions, though at only modest significance.

79 ASTRONOMY AND ASTROPHYSICS↗

A reliable workflow for improving nanoscale X-ray fluorescence tomographic analysis on nanoparticle-treated HeLa cells

Abstract Scanning X-ray fluorescence (XRF) tomography provides powerful characterization capabilities in evaluating elemental distribution and differentiating their inter- and intra-cellular interactions in a three-dimensional (3D) space. Scanning XRF tomography encounters practical challenges from the sample itself, where the range of rotation angles is limited by geometric constraints, involving sample substrates or nearby features either blocking or converging into the field of view. This study aims to develop a reliable and efficient workflow that can (1) expand the experimental window for nanoscale tomographic analysis of local areas of interest within a laterally extended specimen, and (2) bridge 3D analysis at micrometer and nanoscales on the same specimen. We demonstrate the workflow using a specimen of HeLa cells exposed to iron oxide core and titanium dioxide shell (Fe3O4/TiO2) nanocomposites. The workflow utilizes iterative and multiscale XRF data collection with intermediate sample processing by focused ion beam (FIB) sample preparation between measurements at different length scales. Initial assessment combined with precise sample manipulation via FIB allows direct removal of sample regions that are obstacles to both incident X-ray beam and outgoing XRF signals, which considerably improves the subsequent nanoscale tomography analysis. This multiscale analysis workflow has advanced bio-nanotechnology studies by providing deep insights into the interaction between nanocomposites and single cells at a subcellular level as well as statistical assessments from measuring a population of cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detecting damage in composites using volume decomposition analysis of tomographic data

Detection of damage in a single tow ceramic matrix composite specimen has been achieved using orthogonal decomposition of volumetric tomographic datasets collected at four tensile loads. This decomposition approach has been applied at two different length scales: (i) individual fibres and (ii) bulk volumes containing fibres and matrix material. Volumes were first decomposed to feature vectors, orders of magnitude smaller than the original volume they describe, and then comparisons between datasets at different load levels were made in feature vector space. The results show quantitative measurements of damage location, damage morphology and the relative growth of this damage with increased load when compared with a dataset with less or no damage. No prior knowledge of the dataset or training of algorithms is required for damage to be detected, it is only necessary that at least two datasets are available for comparison, e.g. from in situ or repeated scanning measurements. Results are generated on significantly shorter timescales when compared with previous automated approaches to tomography data processing. This approach has the potential to be applied to damage detection in a range of materials through comparisons of volumetric datasets from a range of measurement or computational techniques.

Middleton, Ceri A.↗

Deep-learning-based image registration for nano-resolution tomographic reconstruction

Nano-resolution full-field transmission X-ray microscopy has been successfully applied to a wide range of research fields thanks to its capability of non-destructively reconstructing the 3D structure with high resolution. Due to constraints in the practical implementations, the nano-tomography data is often associated with a random image jitter, resulting from imperfections in the hardware setup. Without a proper image registration process prior to the reconstruction, the quality of the result will be compromised. Here a deep-learning-based image jitter correction method is presented, which registers the projective images with high efficiency and accuracy, facilitating a high-quality tomographic reconstruction. This development is demonstrated and validated using synthetic and experimental datasets. We report the method is effective and readily applicable to a broad range of applications. Together with this paper, the source code is published and adoptions and improvements from our colleagues in this field are welcomed.

deep learning↗

Clutter Distributions for Tomographic Image Standardization in Ground-Penetrating Radar

Multistatic ground-penetrating radar (GPR) signals can be imaged tomographically to produce 3-D distributions of image intensities. In the absence of objects of interest, these intensities can be considered to be estimates of clutter. These clutter intensities spatially vary over several orders of magnitude and vary across different arrays, which makes a direct comparison of these raw intensities difficult. However, by gathering statistics on these intensities and their spatial variation, a variety of metrics can be determined. In this study, the clutter distribution is found to fit better to a two-parameter Weibull distribution than Gaussian or log-normal distributions. Based on the spatial variation of the two Weibull parameters, scale and shape, more information may be gleaned from these data. How well the GPR array is illuminating various parts of the ground, in depth and cross track, may be determined from the spatial variation of the Weibull scale parameter, which may in turn be used to estimate an effective attenuation coefficient in the soil. The transition in depth from clutter- to noise-limited conditions (which is one possible definition of GPR penetration depth) can be estimated from the spatial variation of the Weibull shape parameter. Lastly, the underlying clutter distributions also provide an opportunity to standardize image intensities to determine when a statistically significant deviation from background (clutter) has occurred, which is convenient for buried threat detection algorithm development that needs to be robust across multiple different arrays.

42 ENGINEERING↗

Tomographic Reconstruction of the Neutron Time-Energy Spectrum from a Dense Plasma Focus

A dense plasma focus (DPF) nuclear fusion device is an attractive pulsed neutron source in many applications, due to its relatively large neutron yield, produced in a short time duration. In order to design a DPF that generates neutrons within a specified time profile, or generates a neutron energy spectrum with specific properties, it is necessary to be able to characterize and model the results of the fusion process releasing the neutrons. The time-energy spectrum of fusion neutrons is an ideal quantity to use to validate multiphysics codes that simulate the pinch and fusion processes, because it is a quantity that requires the physics of each of the stages leading up to and ending in the fusion reaction to be simulated correctly. In particular, since DPF fusion neutrons are not monoenergetic -- and there can often be several fusion pinches creating neutrons -- a computer simulation matching high quality neutron spectrum measurements provides great confidence in the fidelity of the simulation. In order to make such a comparison, it is first necessary to have quality measurements from which to infer the spectrum. In this work we pose neutron spectroscopy as the classical tomographic inverse problem from neutron time of flight data at multiple distances, but enhanced by using an additional measurement of the time profile of the fusion pinch near its source and by using detector pairs set up in a geometry that allows for scatter background subtraction. The detector pairs enhance the quality of the time of flight measurements, and the additional constraint posed by the measured time profile allows for reconstructions discretized as finely as the time measurements and in energy as finely as 100 keV, without the problem being underdetermined. We present results from a Deuterium-fueled DPF at the U.S. Department of Energy's Nevada National Security Site and show that we can infer the time-energy spectrum from our measurements for both single and multi-pinch fusion reactions with equal fidelity.

Catenacci, Jared↗

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure (LoTToR) v1.0

The low-tilt tomographic reconstruction (LoTToR) method is a post-processing method to correct the missing-wedge artifact, which contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination. Moreover, the software can be used for hospital computer tomography (CT) to reduce the radiation damage to patients without reducing the CT image quality.

Ren, Gang↗

Seismic Tomographic Modeling of the Crust and Upper Mantle beneath Israel and the Middle East: Improved Resolution through Optimized Model Parameterization

Accurate regional seismic travel-time (RSTT) predictions rely on regional phases (e.g., Pg, Lg, Pn, Sn ) to account for 3D effects in the crust and upper mantle that are not captured by 1D models traditionally used for real-time location. The RSTT prediction model accounts for regional-scale crust and upper mantle structure globally by incorporating regional seismic phases into its travel-time calculations. Previous versions of the RSTT model have used a constant grid cell size of 1°. To improve the tomographic accuracy of recovering velocity structure at regional scales, we, in this study, perform data-driven grid refinement on the RSTT model down to a 0.125° grid (~14 km) in pursuit of two main goals: (1) to test the limits of RSTT capability and accuracy of determined velocity structure through variable grid refinement and (2) to image smaller structures in Israel and the Middle East and illuminate upper mantle dynamics operating in this complex tectonic area. We investigate the effects of model parameterization as grid cell size decreases and the trade-offs between recovered velocity structures. Our final dataset includes 4751 events and 499 stations that recorded 79,344 Pn and 7489 Pg . The variable grid refinement method allows recovery of finer-scale velocity structures and reduces travel-time residuals in areas with the highest data coverage. At smaller grid cell sizes, longer paths need to be upweighted to stabilize the inversion. Results illuminate tectonic features undefined in coarser grid-size models; in particular, we observe mantle perturbations related to the subduction zone around the Cyprian arc and crustal anomalies near the Dead Sea fault and throughout the Anatolian plate.

58 GEOSCIENCES↗

Rock Valley Accelerated Weight Drop Preliminary P-wave Tomographic Model

An active source experiment using an accelerated weight drop was conducted in Rock Valley, Nevada National Security Site, during the spring of 2021 in order to characterize the shallow seismic structure of the region. P-wave first arrival travel times picked from this experiment were used to construct a preliminary 3-D compressional wave speed model over an area that is roughly 4 km wide east-west and 8 km north-south to a depth of about 500-600 m below the surface, but with primary data concentration along the transects of the experimental lines. The preliminary model shows good correlation with basic geology and surface features, but geological interpretation is not the focus of this report. We describe the methods used in the tomographic inversion of the data and show results from this preliminary P-wave model.

42 ENGINEERING↗

Tomographic imaging of atmospheric pressure plasma on complex surfaces

Many plasma types and behaviors such as streamer, arcs, cathode spots, anode spots, ionization waves, and magnetic field interactions create non-symmetric, fully 3D plasma structures. The plasma distribution in 3D space is heavily influenced by complex surfaces and the coupling interactions between plasma properties and the interfacing material properties. For example, ionization waves propagate in directions where ionization rates are highest, leading to complex configurations that are not fully understood or well characterized. Recent advances in laser diagnostics and models have been able to investigate well-controlled idealized plasmas in 2D fashion, but the complex structure in actual plasmas requires a technique than can provide a more complete 3D picture. However, 3D plasma diagnostics do not currently exist. To address this limitation, this activity will leverage available equipment to build a new tomographic optical imaging capability and advance the state-of-the-art in plasma diagnostics to investigate 3D phenomena on complex surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlating Tomographic Chemical Inhomogeneity and Low Energy Electronic Structure in Layered Quantum Materials

Photoemission spectroscopy (PES) is a suite of experimental tools to learn about the electronic and chemical structure of materials and surfaces. Normally implemented in a surface-sensitive manner, the research performed under this grant focused on pushing PES into less explored regimes, to reveal bulk electronic structure, to reveal tomographic (layer-resolved) chemistry and electronic structure of layered materials and heterostructures, and to reveal interface phenomena at the junction of two different materials. Standing wave (SW) spectroscopies have also been applied to PdCoO2, a material of interest due to its high conductivity and electron-hydrodynamic tendencies. This material can be modeled as an alternating layered structure consisting of metallic Pd layers and insulating CoO2 layers. Using SW XPS, the total electronic structure has been decomposed into contributions from the two layers, and computations highlighted the different many-body interactions in the two layers (Comm. Phys. 4, 143 (2021)). We have also used hard-x-ray angle-resolved photoemission spectroscopy (ARPES), to investigate LaB6, a technologically important material with widespread application as a cathode material for electron microscopes. We measured the bulk electronic structure of this material and found that the one-step model of photoemission better captured the electronic structure and correlations. This model treats the three steps of the photoemission process—excitation, transport of the photoelectron to the crystal surface, and escape into the vacuum—as a single quantum mechanically coherent process (Phys. Rev. Mater. 5, 055002 (2021)). We also applied x-ray photoelectron spectroscopy, implemented in a near total reflection grazing incidence geometry to elucidate technologically relevant interfaces, such as those between a substrate and photoresist (J. Phys. D: Appl. Phys. 54 464002 (2021)).

36 MATERIALS SCIENCE↗

Supplementary material for manuscript: Microcomputed X-ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives

This data contains the supplemental information that will be accessible to the public from the paper “Microcomputed X-ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives”. The data set contains the reconstructed slices for the 3D images of three different high explosives including: HMX-HTPB, PBX 9501 and PBX 9502. The data sets are folders of reconstructed tiffs showing the microstructure (crystals, binder, voids) and a segmented data set of each. Finally, a .gif movie is also present that plays the slices sequentially. The folders contain the voxel size information. See the manuscript for more details.

36 MATERIALS SCIENCE↗

Tomographic Muon Imaging of the Great Pyramid of Giza

The pyramids of the Giza plateau have fascinated visitors since ancient times and are the last of the Seven Wonders of the ancient world still standing. It has been half a century since Luiz Alvarez and his team used cosmic-ray muon imaging to look for hidden chambers in Khafre’s Pyramid. Advances in instrumentation for High-Energy Physics (HEP) allowed a new survey, ScanPyramids, to make important new discoveries at the Great Pyramid (Khufu) utilizing the same basic technique that the Alvarez team used, but now with modern instrumentation. Exploring the Great Pyramid Mission plans to field a very large muon telescope system that will be transformational with respect to the field of cosmic-ray muon imaging. We plan to field a telescope system that has upwards of 100 times the sensitivity of the equipment that has recently been used at the Great Pyramid, will image muons from nearly all angles, and will, for the first time, produce a true tomographic image of such a large structure.

47 OTHER INSTRUMENTATION↗

Obtaining a tomographic image from transmission projections

Technique for obtaining tomographic images work directly in signal space and is used to find object configuration by simple summation of density values. Image is reconstructed by precise inverse of scanning. Signal values corresponding to density of projection are added as constant terms along line corresponding to original path between two probes that give rise to that density value.

Heyser, R. C.↗

Medical ultrasonic tomographic system

An electro-mechanical scanning assembly was designed and fabricated for the purpose of generating an ultrasound tomogram. A low cost modality was demonstrated in which analog instrumentation methods formed a tomogram on photographic film. Successful tomogram reconstructions were obtained on in vitro test objects by using the attenuation of the fist path ultrasound signal as it passed through the test object. The nearly half century tomographic methods of X-ray analysis were verified as being useful for ultrasound imaging.

Heyser, R. C.↗