Search NASA⌕ Search

SEARCH · Search NASA

Results for “total ozone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Variations of total ozone in the north polar region as seen by TOMS

Data from the TOMS instrument has been used to follow the course of development of the Antarctic ozone springtime minimum since 1979. Addressed is the question of possible north polar region changes which might be deduced from the nine years of TOMS measurements of total ozone. Total ozone is a much more variable quantity in the Northern Hemisphere than in the Southern Hemisphere. This makes the search for trends more difficult and the interpretation of results more uncertain. The 9-yr time series of TOMS data at high latitudes in the Northern Hemisphere is examined. Because the TOMS measurements have drifted by 3 to 4 percent with respect to closely collocated Dobson measurements, it was chosen in this study to adopt the Dobson normalization and adjust the TOMS measurements accordingly. The difference between the last two years (1986 and 1987) of the TOMS record, and the first two years of the record (1979 and 1980) are shown. The difference in percent is given as a function of latitude and time of year. The Antarctic springtime decrease is clearly seen as well as a smaller change which extends to about 50 degrees south latitude at all seasons. Changes in the Northern Hemisphere are less dramatic and are concentrated near the polar night where solar zenith angles are very large. These data are now being examined in more detail and updated results will be presented at the Workshop.

Stolarski, Richard S.↗

Global patterns of the quasi-biennial oscillation in total ozone

The global structure of the quasi-biennial oscillation (QBO) in total ozone is examined using nine years of total ozone measurements from the Nimbus 7 Total Ozone Mapping Spectrometer. It is shown that the interannual variations of total ozone near the equator are dominated by the QBO and that extratropical anomalies of either sign are largest in the winter season in each hemisphere. Coherent patterns of correlation are found between the equatorial ozone and eddy variances of the ozone field at the equator and in the adjacent subtropics.

Bowman, Kenneth P.↗

Total ozone, ozone vertical distributions, and stratospheric temperatures at South Pole, Antarctica, in 1986 and 1987

Seventy-six electrochemical cell (ECC) ozonesondes were flown at South Pole, Antarctica, during 1987 in a continuing program to document year-round changes in Antarctica ozone that are dynamically and photochemically induced. Dobson spectrophotometer total ozone observations were also made. For the twilight months of March and September when Dobson instrument observations cannot be made at South Pole, total ozone amounts were deduced from the ECC ozonesonde soundings. ECC sonde total ozone data obtained during the polar night (April to August), supplemented the sparse total ozone data obtained from Dobson instrument moon observations. Similar ozone profile and total ozone observations were made at South Pole in 1986.

Komhyr, W. D.↗

Role of Stratospheric Air in a Severe Weather Event: Analysis of Potential Vorticity and Total Ozone

The role of dry stratospheric air descending to low and middle tropospheric levels in a severe weather outbreak in the midwestern United States is examined using ACCEPT Eta model output, Rapid Update Cycle (RUC) analyses, and Earth probe Total Ozone Mapping Spectrometer (EP/TOMS) total ozone data. While stratospheric air was not found to play a direct role in the convection, backward trajectories show stratospheric air descended to 800 hPa just west of the convection. Damaging surface winds not associated with thunderstorms also occurred in the region of greatest stratospheric descent. Small-scale features in the high-resolution total ozone data compare favorably with geopotential heights and potential vorticity fields, supporting the notion that stratospheric air descended to near the surface. A detailed vertical structure in the potential vorticity appears to be captured by small-scale total ozone variations. The capability of the total ozone to identify mesoscale features assists model verification. The total ozone data suggest biases in the RUC analysis and Eta forecast of this event. The total ozone is also useful in determining whether potential vorticity is of stratospheric origin or is diabatically generated in the troposphere.

Goering, Melissa A.↗

Fluctuations of total ozone and their relationship to stratospheric air motions

The origin of fluctuations of total ozone and the interactions that take place between the distribution of total ozone and the circulation of the troposphere are investigated on the basis of observations of total ozone from Nimbus 7 TOMS together with contemporaneous analyses of the circulation. It is shown that a sizable component of total ozone variability is explained by the quasi-columnar motion of air in the lower stratosphere. The development also suggests that in combination with isentropic analyses, total ozone measurements can provide a detailed picture of air motions in the lower stratosphere. Distributions of ozone column abundance and pressure on the 375-K isentropic surface for the Northern and Southern Hemispheres are illustrated.

Salby, Murry L.↗

Defense meteorological satellite measurements of total ozone

A multichannel filter radiometer (MFR) on Defense Meteorological Satellites (DMS) that measured total ozone on a global-scale from March 1977 - February 1980 is described. The total ozone data measured by the MFR were compared with total ozone data taken by surfaced-based Dobson spectrophotometers. When comparisons were made for five months, the Dobson spectrophotometer measured 2-5% more total ozone than the MFR. Comparisons between the Dobson spectrophotometer and the MFR showed a reduced RMS difference as the comparisons were made at closer proximity. A Northern Hemisphere total ozone distribution obtained from MFR data is presented.

Lovill, J. E.↗

Evaluating a New Homogeneous Total Ozone Climate Data Record from GOME/ERS-2, SCIAMACHY/Envisat, and GOME-2/MetOp-A

The European Space Agency's Ozone Climate Change Initiative (O3-CCI) project aims at producing and validating a number of high-quality ozone data products generated from different satellite sensors. For total ozone, the O3-CCI approach consists of minimizing sources of bias and systematic uncertainties by applying a common retrieval algorithm to all level 1 data sets, in order to enhance the consistency between the level 2 data sets from individual sensors. Here we present the evaluation of the total ozone products from the European sensors Global Ozone Monitoring Experiment (GOME)/ERS-2, SCIAMACHY/Envisat, and GOME-2/MetOp-A produced with the GOME-type Direct FITting (GODFIT) algorithm v3. Measurements from the three sensors span more than 16 years, from 1996 to 2012. In this work, we present the latest O3-CCI total ozone validation results using as reference ground-based measurements from Brewer and Dobson spectrophotometers archived at the World Ozone and UV Data Centre of the World Meteorological Organization as well as from UV-visible differential optical absorption spectroscopy (DOAS)/Système D′Analyse par Observations Zénithales (SAOZ) instruments from the Network for the Detection of Atmospheric Composition Change. In particular, we investigate possible dependencies in these new GODFIT v3 total ozone data sets with respect to latitude, season, solar zenith angle, and different cloud parameters, using the most adequate type of ground-based instrument. We show that these three O3-CCI total ozone data products behave very similarly and are less sensitive to instrumental degradation, mainly as a result of the new reflectance soft-calibration scheme. The mean bias to the ground-based observations is found to be within the 1 plus or minus 1 percent level for all three sensors while the near-zero decadal stability of the total ozone columns (TOCs) provided by the three European instruments falls well within the 1-3 percent requirement of the European Space Agency's Ozone Climate Change Initiative project.

Satellite sensors↗

The use of visible-channel data from NOAA satellites to measure total ozone amount over Antarctica

Accurate, detailed maps of total ozone were not available until the launch of the Total Ozone Mapping Spectrometer (TOMS) in late 1978. However, the Scanning Radiometer (SR), an instrument on board the NOAA series satellites during the 1970s, had a visible channel that overlapped closely with the Chappuis absorption band of ozone. We are investigating whether data from the SR can be used to map Antarctic ozone prior to 1978. The method is being developed with 1980s data from the Advanced Very High Resolution Radiometer (AVHRR), which succeeded the SR on the NOAA polar-orbiting satellites. Visible-derived total ozone maps can then be compared able on the NOAA satellites, which precludes the use of a differential absorption technique to measure ozone. Consequently, our method works exclusively over scenes whose albedos are large and unvarying, i.e. scenes that contain ice sheets and/or uniform cloud-cover. Initial comparisons of time series for October-December 1987 at locations in East Antarctica show that the visible absorption by ozone in measurable and that the technique may be usable for the 1970s, but with much less accuracy than TOMS. This initial test assumes that clouds, snow, and ice all reflect the same percentage of visible light towards the satellite, regardless of satellite position or environmental conditions. This assumption is our greatest source of error. To improve the accuracy of ozone retrievals, realistic anisotropic reflectance factors are needed, which are strongly influenced by cloud and snow surface features.

Boime, Robert D.↗

Global trends in total ozone

Satellite ozone data from the Total Ozone Mapping Spectrometer from 1979 through 1986 show that recent decreases of total ozone have not been confined to the Antarctic spring season (the Antarctic ozone hole), but are global in extent. The losses are about twice the estimated uncertainty in the satellite data. The decreases are largest in middle and high latitudes and occur in all seasons of the year. The decreases for this 8-year period are comparable in magnitude to the increases observed during the 1960s. Southern Hemisphere values from 1986 are generally greater than those from 1985.

Bowman, Kenneth P.↗

The utilization of satellite observed total ozone to predict tropical cyclone recurvature

The feasibility of using satellite measurements of total ozone to delineate the characteristic upper-tropospheric wave patterns conductive for tropical cyclone recurvature was investigated using measurements by the Nimbus-7 TOMS instrument measurements of total ozone fields were used to delineate the total ozone distribution for the straight-moving, left-curving, and right-curving tropical cyclones. Using these data for 12-h and 24-h forecasts, it is shown that the composite total ozone maps could be used to differentiate the recurving tropical cyclones from nonrecurving systems, suggesting that the majority of the upper-tropospheric waves delineated by total ozone distribution were deep enough to influence the motion of the storms. The left- and the right-recurving tropical cyclones observed during the 12-hr and 24-hr periods had, respectively, higher and lower upper-tropospheric heights downstream than the nonrecurving cyclones.

Rodgers, Edward B.↗

Quasi-biennial oscillation and tropical waves in total ozone

Westward and eastward propagating tropical waves in total ozone are investigated in 13 years (1979-1991) of version 6 total column ozone data from the Nimbus 7 total ozone mapping spectrometer (TOMS) satellite instrument. A clear synchronization between the stratospheric quasi-biennial osciallation (QBO) zonal winds and the fast (periods less than 15 days) propagating waves in tropical TOMS data is detailed. Largest total ozone wave amplitudes (about 3-6 Dobson units) occur when their phase propagation direction is primarily opposite the Singapore QBO lower-stratospheric winds. This effect is most apparent in meridionally symmetric components. Examination of specific episodes, including cross-spectral calculations with Singapore rawinsonde wind data (10-70 hPa), reveals signatures of tropically confined eastward propagating Kelvin waves of zonal wavenumbers 1-2 during the descending eastward QBO phase, consistent with acceleration of that QBO phase by Kelvin waves. The TOMS results are also consistent with possible forcing of the westward QBO wind phase by episodes of both meridionally symmetric and asymmetric westward waves. However, in contrast to the case of eastward (Kelvin) waves the strongest westward events appear to be filtered by, rather than forcing, the westward phase of the stratospheric QBO wind. These dominant westward episodes are interpreted as meridionally symmetric westward global normal modes and tropically confined equatorial-Rossby waves 2-6. The events exhibit phase and group speeds characteristic of wave dynamics rather than simple wind advection. These results underscore the utility of the long time series and excellent horizontal coverage of TOMS data for dynamical investigations in the relatively observation-poor tropical stratosphere.

Ziemke, J. R.↗

Ozone climatology series. Volume 1: Atlas of total ozone, April 1970 - December 1976

Contours and gridded values are given for seven years of monthly mean total ozone data derived from observations with the Backscattered Ultraviolet instrument on Nimbus-4 for the Northern and Southern Hemispheres. The instrument, algorithm, uncertainties in derived ozone and systematic changes in the bias with respect to the international groundbased ozone network of Dobson instruments, are discussed.

Heath, D. F.↗

Determination of total ozone from HIRS2/MSU sounding data

The total ozone fields computed from the High Resolution Infrared Sounder 2/Microwave Sounding Unit (HIRS2/MSU) are somewhat noisy compared to Total Ozone Mapping Spectrometer (TOMS) results and show latitude dependent systematic errors which vary slowly in time. Researchers used systematic errors from previous time periods to correct the HIRS2 soundings. Comparison of fields of HIRS2 and TOMS derived ozone are shown. Results are encouraging and indicate useful soundings of total O sub 3 burden can be done at night and in the polar winter. Ideally, joint infrared, microwave, and ultraviolet systems should be flown on low Earth orbiting and geostationary satellites to best utilize the complementary nature of the observations.

Susskind, Joel↗

Nimbus 7 total ozone mapping spectrometer (TOMS) data during the Gap, France, ozone intercomparisons of June 1981

The Nimbus 7 Total Ozone Mapping Spectrometer (TOMS) data over Europe have been processed for 2 days of the ozone sensor intercomparison balloon campaign in June 1981 at Gap, France. The June 19 TOMS map shows an elongated ozone maximum (about 400 D.U) extending in a NW-SE direction across central Europe and an ozone minimum (300 D.U.) in the central Atlantic. This pattern produces a 12 D.U. decrease along the balloon trajectory from the fist ascent to the second descent. On June 26 a much smaller ozone maximum (400 D.U.) is centered in northern France with its main axis running in a SW-NE direction. The total ozone contours tend to lie parallel to the balloon trajectory so that the total ozone during the flight is nearly constant.

Krueger, A. J.↗

TOMS total ozone data compared with northern latitude Dobson ground stations

Ozone measurements from the Total Ozone Mapping Spectrometer on the Nimbus 7 satellite are compared with ground-based measurements from five Dobson stations at northern latitudes to evaluate the accuracy of the TOMS data, particularly in regions north of 50 deg N. The measurements from the individual stations show mean differences from -2.5 percent up to plus 8.3 percent relative to TOMS measurements and two of the ground stations, Oslo and Longyearbyen, show a significant drift of plus 1.2 percent and plus 3.7 percent per year, respectively. It can be shown from nearly simultaneous measurements in two different wavelength double pairs at Oslo that at least 2 percent of the differences result from the use of the CC' wavelength double pair instead of the standard AD wavelength double pair. Since all Norwegian stations used the CC' wavelength double pair exclusively a similar error can be assumed for Tromso and Longyearbyren. A comparison between the tropospheric ozone content in TOMS data and from ECC ozonesonde measurements at Ny-Alesund and Bear Island shows that the amount of tropospheric ozone in the standard profiles used in the TOMS algorithm is too low, which leads to an error of about 2 percent in total ozone. Particularly at high solar zenith angles (greater than 80 deg), Dobson measurements become unreliable. They are up to 20 percent lower than TOMS measurements averaged over solar zenith angles of 88 deg to 89 deg.

Heese, B.↗

Estimation of total ozone from satellite measurements of backscattered ultraviolet earth radiance.

Total ozone is estimated from Nimbus IV satellite measurements of the attenuation of backscattered radiances at wavelengths between 3100 and 3400 A. A measurement of the backscattered radiance at 3800 A, outside the ozone absorption band, is used to determine an equivalent Lambert albedo for the cloud-ground-haze surface viewed by the instrument. The measured relative attenuation at two wavelengths is compared with such values precomputed for a series of standard ozone profiles and corrected for the equivalent Lambert albedo. Total ozone is obtained by interpolation. Two alternative methods are used to assign an equivalent Lambert albedo at the absorbing wavelengths. Total ozone values estimated by these methods are compared with the Dobson (ground-truth) data by linear regression. The available evidence suggests that the true standard error of the satellite data may be 0.015 atm-cm or less for solar zenith angles smaller than 60 deg.

Mateer, C. L.↗

The characterization of an air pollution episode using satellite total ozone measurements

A case study is presented which demonstrates that measurements of total ozone from a space-based platform can be used to study a widespread air pollution episode over the southeastern U.S. In particular, the synoptic-scale distribution of surface-level ozone obtained from an independent analysis of ground-based monitoring stations appears to be captured by the synoptic-scale distribution of total ozone, even though about 90 percent of the total ozone is in the stratosphere. Additional analyses of upper air meteorological data, other satellite imagery, and in situ aircraft measurements of ozone likewise support the fact that synoptic-scale variability of tropospheric ozone is primarily responsible for the observed variability in total ozone under certain conditions. The use of the type of analysis discussed in this study may provide an important technique for understanding the global budget of tropospheric ozone.

Fishman, Jack↗

The global distribution on total ozone - Toms satellite measurements

The general behavior of total ozone by season and latitude was known before 1930 through the pioneering observations by Dobson. The ozone record at Oxford and other European stations was dominated by an annual cycle and by irregular short term fluctuations. The amplitude and phase of the annual cycle were determined at representative latitudes in both hemispheres. However, the short term variations appeared to be meteorological origin, although the specific cause could not be identified. Data from the Total Ozone Mapping Spectrometer (TOMS) on the Nimbus 7 spacecraft, with global coverage at an average spatial resolution of 66 km, can now be used to completely map the total ozone field. These maps demonstrate that troughs and ridges in the upper troposphere are responsible for the large, short term ozone variations found at middle latitudes, while in the tropics, the steady, low ozone levels show broad scale structure associated with the Hadley circulation.

Krueger, Arlin J.↗