Search NASA⌕ Search

SEARCH · Search NASA

Results for “trace analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Application of ion-induced nucleation mass spectrometry in the analysis of trace gases evolved from a polyimide film during the thermal curing stages

Trace gases evolved from a polyimide film during its thermal curing stages have been studied using ion-induced nucleation mass spectrometry. The technique involved exposing the test gas sample to a low energy beta source and recording the masses of the ion-induced molecular clusters formed in the reaction chamber. On the basis of the experimentally observed molecular cluster spectra, it has been concluded that the dominant trace component had a molecular weight of 87 atomic mass units. This component has been identified as a molecule of dimethylacetamide (DMAC) which had been used as a solvent in the preparation of the test polyimide specimen. This identification has been further confirmed by comparing the spectra of the test gas sample and the DMAC calibration sample obtained with a conventional mass spectrometer. The advantages of the ion-induced nucleation mass spectrometer versus the conventional mass spectrometer are discussed.

Smith, A. C.↗

Application of Derivative Spectrometry to the Analysis of Trace Gases

A derivative spectrometer is sensitive to changes in spectral intensity over narrow wavelength internal. Specifically, a second derivative spectrometer senses the curvature of the incident spectral intensity, providing an output voltage signal proportional to the second derivative of intensity with respect to wavelength. When such an instrument is combined with multi-pass White cell, a unique trace gas analyzer results. The analyzer, operating within the middle ultraviolet spectral region, provides a highly amplified derivative spectrum of any molecular narrow band absorption which is used for trace gas identification. The intensity of any peak within a spectrum is proportional to the trace gas concentration. Such an analyzer, utilizing a 20 meter pathlength White cell, is presently being used to automatically monitor ambient air for SO2, NO, NO2, and O3 with minimum detectable concentration limits in the part per billion range.

Hager, Robert N.↗

Chemical and Isotopic Analysis of Trace Organic Matter on Meteorites and Interstellar Dust Using a Laser Microprobe Instrument

Polycyclic Aromatic Hydrocarbons (PAHs) are of considerable interest today because they are ubiquitous on Earth and in the interstellar medium (ISM). In fact, about 20% of cosmic carbon in the galaxy is estimated to be in the form of PAHs. Investigation of these species has obvious uses for determining the cosmochemistry of the solar system. Work in this laboratory has focused on four main areas: 1) Mapping the spatial distribution of PAHs in a variety of meteoritic samples and comparing this distribution with mineralogical features of the meteorite to determine whether a correlation exists between the two. 2) Developing a method for detection of fullerenes in extraterrestrial samples using microprobe Laser Desorption Ionization Mass Spectroscopy and utilizing this technique to investigate fullerene presence, while exploring the possibility of spatially mapping the fullerene distribution in these samples through in situ detection. 3) Investigating a possible formation pathway for meteoritic and ancient terrestrial kerogen involving the photochemical reactions of PAHs with alkanes under prebiotic and astrophysically relevant conditions. 4) Studying reaction pathways and identifying the photoproducts generated during the photochemical evolution of PAH-containing interstellar ice analogs as part of an ongoing collaboration with researchers at the Astrochemistry Lab at NASA Ames. All areas involve elucidation of the solar system formation and chemistry using microprobe Laser Desorption Laser Ionization Mass Spectrometry. A brief description of microprobe Laser Desorption Ionization Mass Spectroscopy, which allows selective investigation of subattomole levels of organic species on the surface of a sample at 10-40 micrometer spatial resolution, is given.

Zare, Richard N.↗

Low Power Consumption Laser for Next Generation Miniature Optical Spectrometers for Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 mu m wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 mu m and quantum cascade (QC) lasers in the 4.0-5.0 mu m range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft

distributed feedback laser (DFB↗

Low Power Consumption Lasers for Miniature Optical Spectrometers for Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 micron wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micron and quantum cascade (QC) lasers in the 4.0-5.0 micron range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

Distributed Feedback (DFB) Diode Lasers↗

Low Power Consumption Lasers for Next Generation Miniature Optical Spectrometers for Major Constituent and Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. The minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental frequency of the target gases which are mostly in the 3.0-5.0 micrometers wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micrometers and quantum cascade (QC) lasers in the 4.0-5.0 micrometers range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

semiconductor lasers↗

Combining ray-trace and diffraction analysis: A design example

An example is presented of using a combined ray trace and diffraction modeling code to simulate effects of objective-lens tilt in an optical data storage device. In some cases, neither ray-trace analysis nor diffraction analysis can give an adequate description of an optical system. The designer that is faced with the problem of analyzing such a system is forced to use a ray-trace program to determine aberrations in the exit pupil and then introduce aberration coefficients into a diffraction model that simulate the propagation. This approach was found rather awkward, especially if complicated aberrations are present. Our approach is to integrate a diffraction analysis and a ray-trace description of an optical path into one program. Our design is taken from a data storage application, where we must analyze the effects of objective-lens tilt.

Milster, Tom D.↗

Theoretical analysis of Wolter/LSM X-ray telescope systems

A ray tracing analysis has been performed for the spectral slicing zoom X-ray telescope for configurations in which a convex layered synthetic microstructure (LSM) optic is placed in front of the prime focus or a concave LSM optic is placed behind the prime focus. The analysis has considered the geometrical shape of the LSM optic to be either a hyperboloid, sphere, ellipsoid or constant optical path aspheric element for two configurations of the glancing incidence X-ray telescope: the ATM Experimental S-056 Wolter I system and the Stanford/MSFC Wolter-Schwarzchild nested system. For the different systems the RMS blur circle radii, the point spread function (PSF), the full width half maximum (FWHM) of the PSF have been evaluated as a function of field angle and magnification of the secondary to determine resolution of the system. The effects of decentration and tilt of the selected LSM element on the performance of the system have been studied to determine mounting and alignment tolerances.

Shealy, D. L.↗

Optical modeling for dynamics and control analysis

This paper presents a coordinate-free ray-trace analysis of optical beam trains consisting of mirrors, lenses and reference surfaces. The analysis leads to optical models that can be directly integrated with standard structure and control models for integrated instrument design, analysis and simulation. This capability is required for a coming generation of spaceborn optical instruments which use controlled optical elements supported by flexible structures. New results include analytic formulas for optical sensitivities as functions of structural and control geometric parameters. An example problem calculates a linear (small-motion) optical model, derives optical gains for small- and large-angle controlled mirrors, and shows the propagation of a wavefront.

Redding, David C.↗

FORTRAN 4 programs for summarization and analysis of fracture trace and lineament patterns

Systematic and detailed analysis of lineament and fracture trace patterns has long been neglected because of the large number of observations involved in such an analysis. Three FORTRAN 4 programs were written to facilitate this manipulation. TRANSFORM converts the initial fracture map data into a format compatible with AZMAP, whose options allow repetitive manipulation of the data for optimization of the analysis. ROSE creates rose diagrams of the fracture patterns suitable for map overlays and tectonic interpretation. Examples are given and further analysis techniques using output from these programs are discussed.

Podwysocki, M. H.↗

Conceptual support design of the high resolution mirror assembly for the Advanced X-ray Astrophysics Facility (AXAF)

The performance goals of the Advanced X-ray Astrophysics Facility (AXAF) require that the Wolter I optics support system be insensitive to temperature fluctuations and the effects of gravity during ground testing. Previous work has shown that acceptable concepts are achievable but require much attention to design details. This paper discusses a new support system wherein each optic is held by a single circumfererential ring near its center of mass rather than a multipoint support as previously analyzed. The thermal sensitivity of this system is considerably lower than any concept yet studied. This advanced support concept allows the use of a wider variety of mateials and simple design details. Structural analysis utilizing the finite element method and optical ray-trace analysis are used to predict the system performance.

Cohen, L. M.↗

Theoretical design and analysis of the layered synthetic microstructure optic for the dual path X-ray telescope

A ray tracing analysis was performed for several configurations for the inner channel of the dual path X-ray telescope, which is proposed to use the second mirror of the Stanford/MSFC Wolter-Schwarzchild telescope and a normal incident layered synthetic microstructure (LSM) mirror to form a secondary image near the front of the telescope. The LSM mirror shapes considered were spherical, ellipsoid, hyperboloid, and constant optical path length (OPL) aspheric. Only the constant OPL case gave good axial resolution. All cases had poor off axis resolution as judged by the RMS blur circle radius.

Shealy, D. L.↗

Aqueous nitrite ion determination by selective reduction and gas phase nitric oxide chemiluminescence

An improved method of flow injection analysis for aqueous nitrite ion exploits the sensitivity and selectivity of the nitric oxide (NO) chemilluminescence detector. Trace analysis of nitrite ion in a small sample (5-160 microL) is accomplished by conversion of nitrite ion to NO by aqueous iodide in acid. The resulting NO is transported to the gas phase through a semipermeable membrane and subsequently detected by monitoring the photoemission of the reaction between NO and ozone (O3). Chemiluminescence detection is selective for measurement of NO, and, since the detection occurs in the gas-phase, neither sample coloration nor turbidity interfere. The detection limit for a 100-microL sample is 0.04 ppb of nitrite ion. The precision at the 10 ppb level is 2% relative standard deviation, and 60-180 samples can be analyzed per hour. Samples of human saliva and food extracts were analyzed; the results from a standard colorimetric measurement are compared with those from the new chemiluminescence method in order to further validate the latter method. A high degree of selectivity is obtained due to the three discriminating steps in the process: (1) the nitrite ion to NO conversion conditions are virtually specific for nitrite ion, (2) only volatile products of the conversion will be swept to the gas phase (avoiding turbidity or color in spectrophotometric methods), and (3) the NO chemiluminescence detector selectively detects the emission from the NO + O3 reaction. The method is free of interferences, offers detection limits of low parts per billion of nitrite ion, and allows the analysis of up to 180 microL-sized samples per hour, with little sample preparation and no chromatographic separation. Much smaller samples can be analyzed by this method than in previously reported batch analysis methods, which typically require 5 mL or more of sample and often need chromatographic separations as well.

NASA Discipline Environmental Health↗

Advanced Automation for Ion Trap Mass Spectrometry-New Opportunities for Real-Time Autonomous Analysis

The utility of MS/MS for both target compound analysis and the structure elucidation of unknowns has been described in a number of references. A broader acceptance of this technique has not yet been realized as it requires large, complex, and costly instrumentation which has not been competitive with more conventional techniques. Recent advancements in ion trap mass spectrometry promise to change this situation. Although the ion trap's small size, sensitivity, and ability to perform multiple stages of mass spectrometry have made it eminently suitable for on-line, real-time monitoring applications, advance automation techniques are required to make these capabilities more accessible to non-experts. Towards this end we have developed custom software for the design and implementation of MS/MS experiments. This software allows the user to take full advantage of the ion trap's versatility with respect to ionization techniques, scan proxies, and ion accumulation/ejection methods. Additionally, expert system software has been developed for autonomous target compound analysis. This software has been linked to ion trap control software and a commercial data system to bring all of the steps in the analysis cycle under control of the expert system. These software development efforts and their utilization for a number of trace analysis applications will be described.

Palmer, Peter T.↗