Search NASA⌕ Search

SEARCH · Search NASA

Results for “trace element detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Nanosecond Nd-YAG laser induced plasma emission characteristics in low pressure CO{sub 2} ambient gas for spectrochemical application on Mars

An experimental study is conducted on the possibility and viability of performing spectrochemical analysis of carbon and other elements in trace amount in Mars, in particular, the clean detection of C, which is indispensible for tracking the sign of life in Mars. For this study, a nanosecond Nd-YAG laser is employed to generate plasma emission from a pure copper target in CO{sub 2} ambient gas of reduced pressure simulating the atmospheric condition of Mars. It is shown that the same shock wave excitation mechanism also works this case while exhibiting remarkably long cooling stage. The highest Cu emission intensities induced by 4 mJ laser ablation energy is attained in 600 Pa CO{sub 2} ambient gas. Meanwhile the considerably weaker carbon emission from the CO{sub 2} gas appears relatively featureless over the entire range of pressure variation, posing a serious problem for sensitive trace analysis of C contained in a solid sample. Our time resolved intensity measurement nevertheless reveals earlier appearance of C emission from the CO{sub 2} gas with a limited duration from 50 ns to 400 ns after the laser irradiation, well before the initial appearance of the long lasting C emission from the solid target at about 1 μs, due to the different C-releasing processes from their different host materials. The unwanted C emission from the ambient gas can thus be eliminated from the detected spectrum by a proper time gated detection window. The excellent spectra of carbon, aluminum, calcium, sodium, hydrogen, and oxygen obtained from an agate sample are presented to further demonstrate and verify merit of this special time gated LIBS using CO{sub 2} ambient gas and suggesting its viability for broad ranging in-situ applications in Mars.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mercury Speciation and Stabilization in Saltstone - 19103

Mercury is a contaminant of concern in Savannah River Site (SRS) high level waste (HLW). For five decades elemental mercury was used in the catalytic dissolution of aluminum cladding from the enriched-alloy uranium recovery process. Over 60,000 kg of mercury are now distributed in the SRS HLW tanks. The mercury speciation in the liquid waste streams resulting from conditioning HLW sludge for vitrification and in the decontaminated low activity sodium salt solution removed from the tanks was initially thought to be primarily ionic with a minor amount of elemental mercury. Recent sampling detected organic mercury, primarily methylmercury, HgCH{sub 3}{sup +} (MeHg{sup +}), and a trace amount of ethylmercury (EtHg) in these streams in addition to the ionic and elemental forms of mercury. The objective of this work was to identify the fate of the organic mercury in saltstone, a waste form containing portland cement, slag cement, and Class F fly ash. This information is needed to evaluate total mercury and organic mercury limits for the saltstone Waste Acceptance Criteria to assure regulatory compliance with mixed waste disposal requirements and to evaluate opportunities to enhance the waste form performance. Results to date indicate that the MeHg{sup +} reacts with sulfide in the cementitious reagents, slag in particular, to form nanoparticles of β-HgS, meta cinnabar, which is very insoluble and has a solubility product in water, pK{sub sp}, at 25 deg. C of 53. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Divergence in heritable life history traits suggests potential for local adaptation and trade‐offs associated with a coal ash disposal site

Abstract Globally, human activities have resulted in rapid environmental changes that present unique challenges for wildlife. However, investigations of local adaptation in response to simultaneous exposure to multiple anthropogenic selection pressures are rare and often generate conflicting results. We used an in situ reciprocal transplant design within a quantitative genetic framework to examine how adaptive evolution and phenotypic plasticity contribute to the persistence of an amphibian population inhabiting an environment characterized by high levels of multiple toxic trace elements. We found evidence of phenotypic divergence that is largely consistent with local adaptation to an environment contaminated with multiple chemical stressors, tied to potential trade‐offs in the absence of contaminants. Specifically, the population derived from the contaminated environment had a reduced risk of mortality and greater larval growth and in the contaminated environment, relative to offspring from the naïve population. Further, while survival in the uncontaminated environment was not compromised in offspring from the contaminant‐exposed population, they did show delayed development and reduced growth rates over larval development, relative to the naïve population. We found no evidence of reduced additive genetic variation in the contaminant‐exposed population, suggesting long‐term selection in a novel environment has not reduced the evolutionary potential of that population. We also saw little evidence that past selection in the ASH environment had reduced trait plasticity in the resident population. Maternal effects were prominent in early development, but we did not detect any trends suggesting these effects were associated with the maternal transfer of toxic trace elements. Our results demonstrate the potential for adaptation to multiple contaminants in a wild amphibian population, which may have facilitated long‐term persistence in a heavily impacted environment.

59 BASIC BIOLOGICAL SCIENCES↗

Selective Isotope Determination of Uranium using HR-RIMS

The detection of lowest abundances of the ultra trace isotope {sup 236}U in environmental samples requires an efficient detection method which allows a high elemental and isotopic selectivity to suppress neighbouring isotopes of the same element and other background. High Resolution Laser Resonance Ionization Mass Spectrometry (HR-RIMS) uses the individual electron structure of each isotope to provide an outstanding element and isotope selective ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancement of diffraction efficiency of laminar-type diffraction gratings overcoated with diamond-like carbon (DLC) in soft x-ray region

Boron is the critical trace element in the production of high quality steel, creating a great demand for an efficient detection method of the B-K emission band at around 6.76 nm. To meet this demand we made a simulation study and obtained a practical method to improve the diffraction efficiency of metal-coated laminar-type gratings for a grazing incidence flat-field spectrograph by overcoating a sufficiently transparent high-density material. In the simulation the diffraction efficiency in a spectral region of 3.5-8.5 nm was computed for several combinations of overcoating materials and coating metals, with various thicknesses of the overcoating layer. The result obtained are: (1) the best overcoating material is high-density diamond-like carbon (DLC) having a density of 3.1 g/cm{sup 3}, (2) its optimum thickness is 24 nm at an angle of incidence of 87.0°, and (3) with this thickness the first-order diffraction efficiency is expected to reach 29.7 %, which well exceeds 15.6 % for Ni-coated (or 14.1 % for Au-coated) grating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ liquid SIMS analysis of uranium oxide

Trace analysis of nuclear materials in solid particles collected in the environment or particles in liquid slurry generated in nuclear material manufacturing processes can pinpoint elemental, organic, and isotopic signatures of nuclear fuel cycle activities and processes. Such information can support nuclear safeguards programs by increasing our ability to detect undeclared nuclear materials, routine activities for safeguarding at declared facilities, and illicit activities. However, trace radioactive material analysis in liquids and slurries is challenging using bulk approaches. For example, one drawback of sensitive analysis such as inductively coupled plasma mass spectrometry (ICP-MS) is that sample is consumed or destroyed as a result of the technical approach. We developed a vacuum compatible microfluidic interface to enable surface analysis of liquids and liquid-solid interactions using time-of-flight secondary ion mass spectrometry (ToF-SIMS). In this work, we illustrate initial results of liquid standards containing uranium using in situ liquid SIMS. Specifically a series of diluted uranium standards used for ICPMS analysis were studied and the limit of detection was estimated. Since the liquid SIMS analysis is almost nondestructive, the same sample can be analyzed by other more destructive approaches afterwards or saved for future references. Consequently, multimodal analysis is possible. Our results demonstrate that in situ liquid SIMS can be used as a new approach to analyze radioactive materials in liquid and slurry forms of relevance to the IAEA safeguards missions.

In situ liquid ToF-SIMS, uranium, limit of detecti↗

Technical Report on the Behavior of Trace Elements, Stable Isotopes, and Radiogenic Isotopes During the Processing of Uranium Ore to Uranium Ore Concentrate

The goals of this SP-1 effort were to understand how isotopic and elemental signatures behave during mining, milling, and concentration and to identify analytes that might preserve geologic signatures of the protolith ores. The impurities that are preserved through the concentration process could provide useful forensic signatures and perhaps prove diagnostic of sample origin.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress on the Development of XRF Imaging and Analysis at the Siam Photon Laboratory

XRF imaging and analysis at the Siam Photon Laboratory have been recently developed for supporting various applications in x-ray micro analysis. An experimental setup for white beam x-ray fluorescent imaging has been installed at the beamline BL2 for elemental and quantitative analyses. A white micro beam of 163x170 {mu}m{sup 2}(FWHM) measured by wire scanning has been delivered to samples using a polycapillary x-ray half-lens. The fluorescent emissions of characteristic x-rays (1 keV and above) are detected by a Si-PIN detector. XRF imaging of Ni grids on supporting glass and XRF analysis on a trace-element standard were conducted for testing the apparatus. The test results on these samples as well as the necessary software developed for elemental identification and imaging are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing Natural Attenuation of Cr(VI) in a Chromium Plume at Los Alamos National Laboratory - 18594

Characterization of natural attenuation of hexavalent (Cr(VI)) on aquifer sediments within the Cr plume at Los Alamos National Laboratory has been conducted to (1) refine conceptual and numerical models of chromium fate and transport, (2) evaluate the long-term stability of Cr(III)/Cr(VI) in the complex groundwater system along flow paths from the source to the regional aquifer, and (3) evaluate and develop options for successful remediation. The naturally high chromium abundance in aquifer sediments at Los Alamos pose an unique challenge for characterization of chromium reduction, making conventional approaches such as uptake tests and advanced spectroscopic measurements ineffective in identifying relatively small amounts of anthropogenic Cr(VI) in the sediments. To address this challenge and as complimentary to these conventional methods, sequential leaching tests were conducted on core hole sediments obtained from sonic drilled cores taken from both contaminated and non-contaminated horizons among two mineralogically distinct formations (Puye formation and Miocene Pumiceous Unit) within the Cr plume. A series of three and coherent sequential leaching steps were conducted: 1) an alkaline leach to determine the amount of Cr(VI) sorbed on the sediments. 2) a weak acid leach (using 0.01 M and 0.1 M HNO{sub 3}) to determine the amount of anthropogenic chromium (Cr(III) and Cr(VI)) on aquifer sediment surfaces, and 3) a strong acid leach (using 2 M HNO{sub 3}) to characterize the amount of releasable Cr(III) from aquifer minerals. Additionally we tested the efficiency and detection limit of sequential leaching on bentonite, which consists mainly of smectite, used in drill muds and laboratory-grade biotite spiked with known concentrations of Cr(VI). Smectite and biotite are two phases considered to be potentially important host minerals in aquifer sediments within the plume. Thus, by comparing contaminated and uncontaminated sediment leachate results of chromium and other major and trace elements, the signature and quantity of anthropogenic Cr(VI) can be derived. Our results from the weak acid leaching test indicate that the method detection limit for Cr 'uptake' was about 1 μg/g for biotite and about 0.5 μg/g for bentonite. Our results also indicate that all samples taken from known contaminated horizons in comparison to non-contaminated ones within the Puye formation showed no statistical difference in the amount of Cr leached indicative of its insignificant Cr(VI) attenuation capacity. The amount of excess Cr leached from the magnetic fraction of the contaminated Miocene Pumiceous samples was about 2 μg/g of sediment. Considering that the magnetic fraction was about 11% by mass of the bulk sample, the excess amount of Cr leached from the bulk material would be about 0.2 μg/g of sediment, suggesting the potential for some Cr(VI) attenuation capacity in the Miocene pumice unit. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LDRD 140639 final report : investigation of transmutation claims.

The Proton-21 Laboratory in the Ukraine has been publishing results on shock-induced transmutation of several elements, including Cobalt 60 into non-radioactive elements. This report documents exploratory characterization of a shock-compressed Aluminum-6061 sample, which is the only available surrogate for the high-purity copper samples in the Proton-21 experiments. The goal was to determine Sandia's ability to detect possible shock-wave-induced transmutation products and to unambiguously validate or invalidate the claims in collaboration with the Proton-21 Laboratory. We have developed a suitable characterization process and tested it on the surrogate sample. Using trace elemental analysis capabilities, we found elevated and localized concentrations of impurity elements like the Ukrainians report. All our results, however, are consistent with the ejection of impurities that were not in solution in our alloy or were deposited from the cathode during irradiation or possibly storage. Based on the detection capabilities demonstrated and additional techniques available, we are positioned to test samples from Proton-21 if funded to do so.

36 MATERIALS SCIENCE↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neural induced embryoid bodies present high levels of metals detected by x-ray microfluorescence

Molecular mechanisms driving neural differentiation in human embryonic stem cells are not completely elucidated, specially, the role of atomic elements within this process. In this work, we described the distribution of trace elements in those stem cells growing as embryoid bodies by using synchrotron radiation X-ray microfluorescence (SR-XRF). Naive and neural induced embryoid bodies derived from embryonic stem cells were irradiated with a spatial resolution of 20 {mu}m to make elemental maps and qualitative chemical analyses. We consistently detected metallic elements content raise on neural induced embryoid bodies, mimicking characteristic brain development. The use of SR-XRF reveals that human embryoid bodies exhibit self-organization at the atomic level, which is enhanced during neurogenesis triggered in vitro.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The New Maia Detector System: Methods For High Definition Trace Element Imaging Of Natural Material

Motivated by the need for megapixel high definition trace element imaging to capture intricate detail in natural material, together with faster acquisition and improved counting statistics in elemental imaging, a large energy-dispersive detector array called Maia has been developed by CSIRO and BNL for SXRF imaging on the XFM beamline at the Australian Synchrotron. A 96 detector prototype demonstrated the capacity of the system for real-time deconvolution of complex spectral data using an embedded implementation of the Dynamic Analysis method and acquiring highly detailed images up to 77 M pixels spanning large areas of complex mineral sample sections.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Finding a needle in a haystack: quantitative HERFD-XRF imaging and HERFD-XANES characterization of trace platinum in gold solidi from the Late Roman and Byzantine Empires

High-Energy Resolution Fluorescence Detection X-Ray Fluorescence (HERFD-XRF) imaging and HERFD X-ray Absorption Near Edge Structure (XANES) spectroscopy are used to quantify and characterize trace platinum (Pt) in gold solidi from the Late Roman and Byzantine Empires. Historically, the elemental analysis of coins has been pivotal in distinguishing authentic artifacts from forgeries, elucidating minting practices, and understanding economic shifts. Notably, a new gold source with high platinum content appeared in the fourth century CE, transforming the Roman economy. Traditional methods struggled to detect platinum due to the overwhelming gold matrix. Here, this study demonstrates the effectiveness of HERFD techniques in resolving this challenge. Three gold solidi, minted between 654 and 659 CE, were analyzed alongside reference gold materials with known Pt concentrations. The HERFD-XRF imaging revealed spatial distributions of platinum, highlighting non-uniformities within the coins. Additionally, HERFD-XANES spectroscopy identified the oxidation states and chemical speciation of platinum. Results demonstrate that platinum in the solidi primarily exists as metallic Pt, with some surface oxidation. The findings align with previous measurements but reveal higher Pt concentrations and significant inhomogeneities. This research confirms the reliability of HERFD methods for quantifying trace elements and provides new insights into the raw material sources and minting techniques of ancient gold coins. The non-destructive nature of this approach allows for extensive analyses, offering valuable data for historical, economic, and archaeological studies. This innovative application of HERFD-XRF imaging and XANES in cultural heritage research underscores the potential for detailed material characterization and conservation, enhancing our understanding of ancient economies and trade patterns.

Van Loon, Lisa L.↗

An in situ approach to study trace element partitioning in the laser heated diamond anvil cell

Data on partitioning behavior of elements between different phases at in situ conditions are crucial for the understanding of element mobility especially for geochemical studies. Here, we present results of in situ partitioning of trace elements (Zr, Pd, and Ru) between silicate and iron melts, up to 50 GPa and 4200 K, using a modified laser heated diamond anvil cell (DAC). This new experimental set up allows simultaneous collection of x-ray fluorescence (XRF) and x-ray diffraction (XRD) data as a function of time using the high pressure beamline ID27 (ESRF, France). The technique enables the simultaneous detection of sample melting based to the appearance of diffuse scattering in the XRD pattern, characteristic of the structure factor of liquids, and measurements of elemental partitioning of the sample using XRF, before, during and after laser heating in the DAC. We were able to detect elements concentrations as low as a few ppm level (2-5 ppm) on standard solutions. In situ measurements are complimented by mapping of the chemical partitions of the trace elements after laser heating on the quenched samples to constrain the partitioning data. Our first results indicate a strong partitioning of Pd and Ru into the metallic phase, while Zr remains clearly incompatible with iron. This novel approach extends the pressure and temperature range of partitioning experiments derived from quenched samples from the large volume presses and could bring new insight to the early history of Earth.

36 MATERIALS SCIENCE↗

Laser-Induced Breakdown Spectroscopy (LIBS) Sensing for Environmental and Subsurface Monitoring

Groundwater monitoring is essential to timely and accurately reflect the current situations and the trends of water quality. However, the long-term stability and survival of any potential in-situ monitoring method is threatened by the harsh conditions and the groundwater monitoring in downhole environments poses numerous challenges to the sensor community. Laser induced breakdown spectroscopy (LIBS) has been demonstrated as a promising technology for chemical monitoring in high-temperature high-pressure (HTHP) environments and hard to reach places. The technique demonstrates several advantages, such as rapid, real-time, in-situ, and simultaneous detection of multiple elements with simple or no sample preparation. This chapter includes a brief review of the field-portable LIBS systems, and development of a compact, robust, and simple LIBS instrument for downhole HTHP water quality monitoring. The fieldable prototype sensor is tested in an onsite monitoring well where trace elements’ concentrations are tracked over an extended period. The testing has verified that the fiber coupled design performs as desired. The system shows good calibration linearity for tested elements and collection times, and Limits of Detection (LODs) that are comparable to those of tabletop LIBS instruments. In addition to groundwater quality monitoring, the fabricated LIBS-based sensor could have widespread sub-surface detection applications.

Jain, Jinesh [NETL Site Support Contractor, Nation↗

Analysis of Rare Earth Elements in Uranium Using Handheld Laser-Induced Breakdown Spectroscopy (HH LIBS)

In this paper, a portable handheld laser-induced breakdown spectroscopy (HH LIBS) instrument was evaluated as a rapid method to qualitatively analyze rare earth elements in a uranium oxide matrix. This research is motivated by the need for development of a method to perform rapid, at-line chemical analysis in a nuclear facility, particularly to provide a rapid first pass analysis to determine if additional actions or measurements are warranted. This will result in the minimization of handling and transport of radiological and nuclear material and subsequent exposure to their associated hazards. In this work, rare earth elements (Eu, Nd, and Yb) were quantitatively spiked into a uranium oxide powder and analyzed by the HH LIBS instrumentation. This method demonstrates the ability to rapidly identify elemental constituents in sub-percent levels in a uranium matrix. Preliminary limits of detection (LODs) were determined with values on the order of hundredths of a percent. Validity of this methodology was explored by employing a National Institute of Standards and Technology (NIST) standard reference materials (SRM) 610 and 612 (Trace Elements in Glass). Finally, it was determined that the HH LIBS method was able to clearly discern the rare earths elements of interest in the glass or uranium matrices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗