Search NASA⌕ Search

SEARCH · Search NASA

Results for “traffic awareness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

44 records · Page 3

Computer Science Research Needs for Parallel Discrete Event Simulation (PDES)

Historically, scientific computing efforts have demonstrated the clear need for, and effective use of, supercomputing with traditional time-stepped simulations. Nevertheless, there are several areas in the mission spaces of the U.S. Department of Energy and other agencies waiting to tap advanced computing research using a different, discrete event style of modeling, simulation, and analysis. These span a wide spectrum of applications including energy grid resilience, urban planning and policy, transportation science, building technologies, emergency response and planning, environmental impact analysis, computational epidemiology, Internet communications, cyber security, and cyber-physical systems, to name only a few. Even within traditional scientific applications, the role of discrete event modes of execution is increasing in the form of new event-based mathematical solvers such as quantized state integration methods and discrete-continuous hybrid system solvers. Co-design of advanced supercomputing hardware systems is another area that exploits discrete event simulation at its core for effective analyses. Complex systems, entity behaviors and interconnections play a significant role in all these applications, which are mapped to large-scale models with discrete event formulations. To make advancements in all the aforementioned scientific areas, many technical aspects need to be more thoroughly studied and deeply understood in parallel discrete event simulation (PDES). The unique dynamics inherent in a discrete event modeling approach, by their very nature, intersect and influence the entire stack of the computing system, including (a) the unique nature of the instruction sets exercised in PDES workloads without a predominance of high-precision floating point operations, (b) virtual time-constrained multi-threaded execution of many logical processes per processor, (c) extremely variable and difficult to predict network traffic characteristics, (d) interfaces and inter-dependencies with machine learning and artificial intelligence codes at higher software layers, and (e) highly challenging load balancing needs, especially in effectively accounting for accelerated/extremely heterogeneous computing in current and future high-performance computing systems. Efficient and accurate parallel execution of PDES workloads is also dominated by challenges in dealing with their asynchronous concurrency fundamentally present at the model level. Conservative synchronization, optimistic/speculative synchronization, and their hybrid schemes open new questions in fundamental computer science with respect to reversibility of computation and prediction (lookahead) of behaviors inherent within model codes. On the implementation front, there are relatively few scalable, general-purpose parallel discrete event simulators in the world, and even fewer have been studied on emerging hardware platforms. To enable scientific advances using PDES, the research needs in computer science must also be pursued and met in the intersection of the algorithmic and hardware-aware aspects of scalable PDES engines. This report is aimed at capturing a computer science-oriented view of this important area of research in PDES, presenting a sample of important applications with their inherent discrete event technology elements. Needs are outlined in core areas of parallel discrete event research as well as cross-cutting directions in computer science research that positively impact scientific advancements across several important application areas. A selection of priority research opportunities in advanced computing for PDES is identified to serve as reference for key research topics and their order of importance for scientific advancements.

97 MATHEMATICS AND COMPUTING↗

NREL Infrastructure Perception and Control Workshop

A lack of highly reliable, full state-space awareness of roadway situations is the current bottleneck for the incremental introduction of smart infrastructure control. NREL's Infrastructure Perception and Control (IPC) lab applies advanced sensing and computation controls to the coordinated movement of vehicles on the road as well as people in large facilities and has produced field test results from a Colorado Springs intersection. In this presentation, NREL discusses the state of smart infrastructure control and opportunities for partnership.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

From Sim to Real: A Pipeline for Training and Deploying Traffic Smoothing Cruise Controllers

Designing and validating controllers for connected and automated vehicles to enhance traffic flow presents significant challenges, from the complexity of replicating real-world stop-and-go traffic dynamics in simulation, to the intricacies involved in transitioning from simulation to actual deployment. In this work, we present a full pipeline from data collection to controller deployment. Specifically, we collect 772 km of driving data from the I-24 in Tennessee, and use it to build a one-lane simulator, placing simulated vehicles behind real-world trajectories. Using policy-gradient methods with an asymmetric critic, we improve fuel efficiency by over 10% when simulating congested scenarios. Our comprehensive approach includes reinforcement learning for controller training, software verification, hardware validation and setup, and navigating various sim-to-real challenges. Furthermore, we analyze the controller's behavior and wave-smoothing properties, and deploy it on four Toyota Rav4’s in a real-world validation experiment on the I-24. Lastly, we release the driving dataset, the simulator and the trained controller, to enable future benchmarking and controller design.

42 ENGINEERING↗

Probabilistic Data Association for Orbital-Element Estimation Using Multistage Expectation–Maximization

Tracking space objects is important for managing space traffic and predicting collisions, but is difficult in part due to data association and orbit model uncertainty. Expectation–maximization (EM) is a commonly used tracking method that has not been widely considered for tracking space objects. The technique consists of iteratively computing data association probabilities with a set of current element estimates, and updating estimates of the elements by solving a nonlinear weighted least-squares regression problem where the weights are the data association probabilities. In this paper, we demonstrate the use of EM for probabilistic data association and orbital-element estimation by applying the technique to simulated data from two angles-only tracking scenarios. In both scenarios, EM provides correct data associations and accurate maximum likelihood estimates of orbital elements. One scenario considers tracking a single object in clutter and quantifies the improvement of the orbital-element estimates and data associations as the detection probability increases. However, standard application of EM requires knowing the number of objects or may fail when a large number of objects are present. To address these issues, this paper employs a multistage version of EM that is applicable when there are a large and possibly unknown number of objects.

97 MATHEMATICS AND COMPUTING↗

Energy-Efficient Maneuvering of Connected and Automated Vehicles (CAVs) with Situational Awareness at Intersections (Final Progress Report)

The increased development of Connected and Automated Vehicle (CAV) systems, currently used for safety and driver convenience, presents new opportunities to improve the energy efficiency of vehicles. Southwest Research Institute (SwRI) achieved a 20% energy consumption reduction in a 2017 Toyota Prius Prime plug-in hybrid by using connectivity (V2V, V2I, V2X) as part of the Next Generation Energy Technologies for Connected and Automated on-Road Vehicles (NEXTCAR) program. The energy consumption gains were achieved by a combination of vehicle dynamics and powertrain control algorithms with a focus on SAE L1 and L2 automated vehicles where a human is still responsible for safe operation. SwRI is now involved in NEXTCAR-II, focusing on energy-efficient control tech for SAE Level 4/5 automated vehicles, aiming for a 30% energy reduction compared to stock hybrids. The rise of Mobility as a Service (MaaS) is driving investments in L4 and L5 automated vehicles. A study by the University of Michigan shows these vehicles might increase energy use and emissions by 3-20%. Technology similar to NEXTCAR can enhance energy efficiency in highly automated vehicles, leveraging improved sensing and actuation capabilities. While the NEXTCAR programs targeted energy efficiency improvements for a single vehicle, this program adopts a more expansive approach. It places its focus on understanding and testing the cumulative effects within a region or corridor, aiming to assess how a subset of vehicles equipped with NEXTCAR-style technologies influence the overall energy consumption of all vehicles traveling within that area. Additionally, the program explores infrastructure-based mobility solutions to optimize efficiency, and seeks to understand and quantify public perception and likelihood of technology adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Autonomous System Subversion Tactics: Prototypes and Recommended Countermeasures

One of the fielding requirements for Advanced and Small Modular Reactors (AR/SMR) is the ability to support remote and autonomous operations. Autonomous Control Systems (ACS) are found on platforms such as Autonomous Space Vehicles, Cruise Missiles, and advanced driver-assistance systems. Each of these ACS implementations depends upon a set of decision support subsystems responsible for supporting Autonomous Mission Managers (names vary based upon field and author preferences). These Autonomous Mission Managers receive inputs from system sensors (e.g., LIDAR collection from an automobile travelling down a street; transients from a nuclear reactor), and perform a set of classifications (e.g., Red Traffic Light; Small Pedestrian at 10m; Load Rejection; Single Coolant Pump Trip), and then use these classifications in combination with recommendation algorithms to achieve platform goals (e.g., Stop the Vehicle at the Traffic Light, Avoid the Small Pedestrian; Trip the Reactor to prevent a Safety Event). The design, implementation, and fielding of an ACS capability will alter the cyber-attack surface such that existing risk management plans will need to be updated to include how to protect and defend against data-science and decision-support-system attack classes. These attack classes would include protection of the design and training environments where algorithm selection and testing and training data would be obvious attack vectors. These attack classes would also require an informed set of detection and response procedures to identify anomalous behaviors and document best practices for anomaly assessment and vulnerability mitigation and remediation. Last year we published a Cyber Threat Assessment Methodology for Autonomous and Remote Operations for AR/SMRs along with a companion publication on Cyber Attack and Defense Use Cases. The focus of the methodology was on describing and enumerating ACS processes, components, and functions such that security engineers could: evaluate subversion options against the target; identify threat actor attributes and capabilities derived from each subversion option; and identify security controls and response countermeasures. The Use Cases document offered detailed methodology examples including an assessment of a Military Base SMR, an Autonomous System Decision Loop, and implementation of AR/SMR Machine Learning algorithms. Our proposal at the end of last year was to focus on implementation of subversion prototypes related to the last Use Case area: AR/SMR Machine Learning (ML) Algorithms. We included six attack scenarios in our Use Cases paper: a Poisoning Attack against ML functions implemented using an FPGA; a Trojaning Attack against ML classifiers exploiting the excitability of Nuclear Engineers; a Backdooring Attack against ML Training environments to ensure persistence of an attack vector; a False Positive Evasion Attack against multi-factor Access Control Systems using clever inputs; an Inference Attack against ML models by an Insider with access to the Operational environment; and an Adversarial Reprogramming Attack against a Material Access Control Video Surveillance System. At the beginning of this year these six attack scenarios were provided to our research teams at Georgia Tech and Idaho State University and each team successfully implemented a subversion attack against a ML implementation to include transient misclassifications. While this is a notable outcome from this type of research, this paper offers the reader insight into not only how to structure and execute these types of attacks, but into the thought process behind how the researcher investigated the problem space, performed initial algorithm implementation, and the trial-and-error behind arriving at the successful subversion prototypes. We include in this paper a set of associated Scenarios on how these subversion prototypes could be implemented and an initial set of guidance for AR/SMR architects, Nuclear Regulators, and Cyber Defenders to implement awareness and defense capabilities into their current operational portfolios.

42 ENGINEERING↗