Search NASA⌕ Search

SEARCH · Search NASA

Results for “two-phase simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Advanced Multiphysics Code Coupling for Cladding Surface Thermocouples During Two-Phase Heat Transfer from Nuclear Fuel

Transient testing of nuclear fuel involves the evaluation of fuel performance under off-normal and accident conditions and is essential for proving design performance. Instrumentation included in such experiments commonly includes thermocouples attached to the outer surface of the cladding to provide temperature measurements throughout the transient. However, the presence of thermocouples on the cladding surface can alter the local heat transfer characteristics with the surrounding coolant. These localized effects can influence the temperature of the nearby cladding surface and introduce uncertainties in interpreting the thermocouple data. Understanding the impact of thermocouples attached to the outer surface of the cladding is crucial for accurate data interpretation as well as its effect on the thermomechanical behavior of the cladding. This paper presents a novel methodology for simulating the impact of outer cladding thermocouples during transient testing of nuclear fuels. The simulation framework leverages the thermal-hydraulic capabilities of RELAP5-3D coupled to the BISON fuel performance code through the RELAPCouplingApp interface. The methodology is compared against Accident Tolerant Fuel Reactivity Initiated Accident-1-E experiment performed at Idaho National Laboratory. The results reveal approximately 100°C difference between thermocouple-altered temperature and virgin cladding surface. The model overpredicts surface rewet time due to conservative correlations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development and Validation of Two-Phase Flow Models in MOOSE for Molten Salt Reactor Application

Two-phase flow in Molten Salt Reactors (MSRs) is important as it impacts reactivity evolution, reactor transient response, and the removal of species dissolved in the molten salt through gas phase transfer. Therefore, accurately predicting the gas distribution and the associated liquid-gas interface area in MSRs is essential for their design and operation. Recently, we integrated two new models into Idaho National Laboratory (INL)’s Multiphysics Object-Oriented Simulation Environment (MOOSE): a multi-D generalization of a mixture drift-flux model and a Euler-Euler model. The Euler-Euler model offers higher fidelity, while the mixture drift-flux model provides greater computational efficiency, which is typically preferred for modeling reactor transients. However, the mixture model's accuracy in capturing void distribution and interfacial area in MSRs still needs to be assessed. This article begins with a description of the mathematical framework for the two-phase models implemented in MOOSE. It then presents validation of these models against relevant experimental data. Finally, both models are applied to the Molten Salt Reactor Experiment case study, analyzing various operational conditions such as different rates of fission product volatilization and diverse cover gas entrainment scenarios at the reactor pump. The article concludes by assessing the suitability of both models for capturing the two-phase flow dynamics critical to MSR operations.

42 - ENGINEERING↗

Development and Validation of Two-Phase Flow Models in MOOSE and Application to Molten Salt Reactors

Two-phase flow in Molten Salt Reactors (MSRs) is important as it impacts reactivity evolution, reactor transient response, and the removal of species dissolved in the molten salt through gas phase transfer. Therefore, accurately predicting the gas distribution and the associated liquid-gas interface area in MSRs is essential for their design and operation. Recently, we integrated two new models into Idaho National Laboratory (INL)’s Multiphysics Object-Oriented Simulation Environment (MOOSE): a multi-D generalization of a mixture drift-flux model and a Euler-Euler model. The Euler-Euler model offers higher fidelity, while the mixture drift-flux model provides greater computational efficiency, which is typically preferred for modeling reactor transients. However, the mixture model's accuracy in capturing void distribution and interfacial area in MSRs still needs to be assessed. This article begins with a description of the mathematical framework for the two-phase models implemented in MOOSE. It then presents validation of these models against relevant experimental data. Finally, both models are applied to the Molten Salt Reactor Experiment case study, analyzing various operational conditions such as different rates of fission product volatilization and diverse cover gas entrainment scenarios at the reactor pump. The article concludes by assessing the suitability of both models for capturing the two-phase flow dynamics critical to MSR operations.

42 - ENGINEERING↗

Trends in spatial correlations, two-phase coexistence, and criticality in a class of type-2 Schloegl models for autocatalysis

A class of type-2 Schloegl models is considered for particles on a square lattice with variable-range cooperativity. These models involve: (i) spontaneous particle annihilation at rate p; (ii) autocatalytic particle creation at unoccupied sites (i, j) with n ⩾ 2 particles within a specified neighborhood, Ω 𝑁 (i, j), of sites at rate $k_n$ = $\frac{^{(^n_2)}}{_{(^N_2)}}$ = $\frac{n{(n-1)}}{_{N(N-1)}}$; and (iii) possible spontaneous particle creation at unoccupied sites at “small” rate ɛ ⩾ 0. In some cases, Ω 𝑁 just includes all symmetry-equivalent sites at a single specific distance 𝑑 (in units of lattice constants) from the unoccupied site, e.g., 𝑑 = 1 (nearest-neighbor sites) where 𝑁 = 4, or 𝑑 = √5 (or √13 or…) where 𝑁 = 8. In other cases, Ω 𝑁 includes sites multiple distances from the unoccupied site, e.g., 𝑑 = {1,√2}, where 𝑁 = 8. Kinetic Monte Carlo (KMC) simulation reveals that these models exhibit a nonequilibrium discontinuous phase transition between high- and low-density states below a critical point, ɛ < ɛ c , with generic two-phase coexistence (2PC) at least for smaller 𝑁. With some exceptions, there is an approach toward mean-field behavior with increasing 𝑁 (so the regime of generic 2PC shrinks, and ɛ c approaches the mean-field value of 1/27). Additional insight into trends is provided by analysis of the exact master equations for the models via hierarchical truncation. These truncations utilize suitably tailored pair approximations which reflect the dominant nonequilibrium spatial correlations. These correlations in turn are shown to reflect the details of the autocatalytic particle creation process. For spatially heterogeneous states, the truncations produce coupled sets of lattice differential equations (LDE) which can describe orientation-dependent propagation of an interface between high- and low-density steady states for ɛ < ɛ c . Pair approximation values of 𝑝 = 𝑝 eq where the interface is stationary, and its orientation-dependence, are in semiquantitative agreement with KMC results. In conclusion, this comparison accounts for propagation failure in the LDE which complicates interpretation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Two-phase flow numerical analysis of electrode geometry for alkaline water electrolyzers

Hydrogen is a promising component of a future energy-secure and efficient economy, but its competitiveness depends on reducing production costs. One strategy is to operate alkaline water electrolyzers at higher current densities to increase output. However, this intensifies performance losses due to gas bubble accumulation, which blocks transport pathways and deactivates electrochemically active surfaces. Enhancing bubble evacuation through electrode design is therefore essential. Previous studies have explored various approaches — such as modifying surface morphology, applying sonication or pressure modulation, and introducing surfactants — but these efforts have addressed a limited range of conditions due to the complexity of two-phase flow and electrode geometries. Experiments have also largely been focused on either cell level improvements, which lack the information necessary to isolate each contributing factor, or on modified geometries that are not relevant to practical cell operation. From a modeling perspective, conventional Eulerian multiphase models do not track the complex gas–liquid interfacial dynamics and often neglect surface tension and contact angle effects, reducing their predictive accuracy. To provide insights on the effects of different electrode geometries on the performance of alklaine water electrolyzers this work employs an immersed boundary volume-of-fluid method to simulate bubble behavior in 3D porous electrodes. Multiple base electrode geometries, typically used in practice, with varying porosity are evaluated under a constant surface gas generation rate. Simulation data is analyzed to quantify electrode gas coverage, bubble size dynamics and other relevant metrics. Results show that porosity strongly influences bubble accumulation on electrode surfaces, with higher porosity reducing gas coverage, and its not strictly dependent on the electrode geometry. However, the electrode’s base geometry significantly affects gas accumulation at the separator gap, independent of porosity. A foam electrode geometry resulted in the lowest gas coverage of all electrodes with a median volumetric gas coverage of 11%, but at the cost of a 70% reduction in active area compared with the largest surface area electrode, while gyroid electrodes showed the best trade-off between gas coverage, particularly at the separator surface, and electrochemically active area. In conclusion, the results highlight the need for holistic electrode design strategies.

Alkaline↗

Heat load measurements for the PIP-II pHB650 cryomodule

Phase-3 testing of the pHB650 cryomodule at the PIP-II Injector Test Facility was conducted to evaluate the effectiveness of heat load mitigations performed after earlier phases of testing and to continue pinpointing any sources of unexpectedly high heat loads.. The programme measured HTTS, LTTS, and 2 K isothermal/non-isothermal loads under "standard", "linac", and "simulated dynamic" operating modes, recording data both inside the cryomodule and across the bayonet can circuits. Thermal-acoustic oscillations were eliminated by replacing the original G10 cooldown-valve stem with a stainless-steel stem fitted with wipers. A newly developed Python script automated acquisition of ACNET data, performed real-time heat-load calculations, and generated plots and tables that were posted to the electronic logbook within minutes, vastly reducing manual effort and accelerating feedback between SRF and cryogenics teams. Analysis showed that JT heat-exchanger effectiveness and temperature stratification in the two-phase and relief piping strongly influence the observed loads and helped isolate sources of excess heat. The campaign demonstrates that rigorous pre-test planning, real-time diagnostics, and automated reporting can improve both accuracy and efficiency, providing a template for future PIP-II cryomodule tests and for implementing targeted heat-load mitigations.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.] (ORCID:↗

Non-dimensional performance and safety parameters for heat pipes

The use of heat pipes in safety-critical systems such as nuclear microreactors dictates the development of generalized, practical, scalable performance and safety parameters. Traditional dimensional metrics, while informative, lack the universality required for comparative analysis across varying designs and operating regimes. Here, this work introduces a comprehensive set of non-dimensional parameters to characterize heat pipe performance and safety, including capillary performance, effective thermal conductivity, response time, exergetic efficiency, allowable temperature gradients, allowable rate of temperature change, priming coefficients, and factor of safety. A reference heat pipe design representative of microreactor applications was analyzed via the developed parameters using both traditional analytical models and Sockeye simulations under transient and steady-state conditions. Sodium, potassium, and water were evaluated as working fluids to demonstrate the applicability of the framework across a broad temperature range. The proposed non-dimensional parameters effectively captured key thermal-hydraulic behaviors and safety concerns, as was demonstrated via Sockeye simulations. This framework supports the development of design optimization strategies, operational protocols, and safety assurance practices for advanced reactor systems and other high-reliability applications.

42 - ENGINEERING↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nonequilibrium defect-phase nanostructures stabilized by irradiation in undersaturated Ni-Si nanocrystalline alloy

Nanocrystalline thin films of the undersaturated alloy Ni-8.5 at% Si were subjected to 2 MeV Ti irradiation at temperatures ranging from 450˚C to 550˚C. Correlative microscopy combining transmission electron microscopy (TEM), scanning-TEM and atom probe tomography (APT revealed that large dose irradiation at 450˚C of samples with initial grain sizes below 100 nm stabilized a novel nanostructure which surprisingly contained three co-existing phases, the γ face-centered-cubic (FCC) matrix, γ' L12 ordered precipitates on intragranular dislocation loops and Ni 31 Si 12 precipitates at triple junctions (TJs). In contrast, irradiation at 550˚C and irradiation of larger grain-size samples at 450˚C only produced a γ-γ' two-phase coexistence. Analysis of the three-phase nanostructure and phase field simulations indicates that radiation-induced segregation is most pronounced at TJs, thus triggering the formation of Ni 31 Si 12 precipitates. These incoherent precipitates, in turn, are expected to stabilize the grain size under irradiation. The results are generalized using the concept of driven defect-phases. It is suggested that the stabilization of driven defect-phases may impart radiation resilience by providing localized relaxation modes to the microstructure evolution during and after temporary perturbations in irradiation conditions.

36 MATERIALS SCIENCE↗

Determining the extent of potential fugitive fluid migration from geologic carbon storage in hydrocarbon-bearing reservoirs: Insights from one-dimensional numerical modeling

Numerical modeling of Geologic Carbon Sequestration in permeable reservoirs initially containing hydrocarbons is conducted using the multi-phase, multi-component thermohydrologic simulator TOGA (TOUGH Oil, Gas, Aqueous; TOUGH stands for Transport Of Unsaturated Groundwater and Heat), to determine how phase and composition of the original fluids influence the extent of the zone where upward fugitive fluid migration could potentially occur, denoted R f . The area within R f comprises regions of substantially elevated pressure and free-phase CO 2 saturation, where a breach in reservoir sealing capacity would lead to upward fugitive fluid migration. The model examines the conditions within the storage reservoir that could lead to fugitive flow, but does not model the fugitive flow itself. A one-dimensional radial model of the storage reservoir is used, and three initial phase conditions are considered: single-phase aqueous, two-phase gas-aqueous, and three-phase oil-gas-aqueous. Components that may be present are H 2 O, CO 2 , CH 4 , C 4 H 10 , and C 10 H 22 . The most important factors controlling Rf are (1) the initial gas-phase saturation within the reservoir, and (2) the lateral extent of multi-phase initial conditions, particularly CO 2 . The composition of liquid and gas phases has a secondary effect. The impact of reservoir depth, thickness, injection rate, and hydrologic properties are also briefly examined, with thickness (or equivalently injection rate) having the biggest effect. These results can help to understand important trends in potential response of CO 2 -EOR fields being considered for dedicated CO 2 storage.

CO₂ plume migration↗

3D interface size effects on slip transfer in Ti/Nb nanolaminates

Two-phase nanolaminates are well-renowned for achieving extraordinarily high strengths but at the sacrifice of reduced toughness and strain to failure. Recently ”thick” interfaces, or so called 3D interfaces, in Cu/Nb nanolaminates were experimentally shown to improve both of these mechanical properties. Here, in this work, we study the effect of 3D interfaces in the hexagonal close packed (HCP)/body centered cubic (BCC) Ti/Nb nanolaminate system. Nanoindentation hardness testing suggests increased strength with the introduction of a 3D Ti–Nb interface and a positive size effect with increases in 3D interface thickness from 5 nm to 20 nm. To understand this effect from a single dislocation perspective, we present a phase-field dislocation dynamics (PFDD) model for multi-phase HCP/BCC systems. We employ the model to simulate stress-driven transfer of single dislocations across 3D Ti/Nb interfaces of various thicknesses. Our results show that the critical stress for slip transfer increases with the thickness of the interface. This positive size effect is stronger for transfer from basal or prismatic dislocations in the Ti layer to 110$\langle$111$\rangle$ dislocations in the Nb layer than the reverse. For this Ti/Nb system, a critical thickness of 2 nm is identified at which the asymmetry in slip transfer is minimized. This work showcases 3D interfaces as a beneficial microstructure modification to strengthen as well as reduce anisotropy in nanocrystalline materials containing HCP phases.

Dislocations↗

Continuum shock mixture models for Ni+Al multilayers: Individual layers and bulk equations of state

Continuum shock mixture models are reviewed and applied to determine the equations of state for five different compositions of Ni x Al y ⁠, as well as bulk Ni+Al reactive multilayers, by combining the fundamental property data for elemental nickel and aluminum. From the literature, we down-select and evaluate two analytical models for the mixture Hugoniot, i.e., the well-known method of kinetic energy averaging (KEA) and a recent model proposed by Jordan and Baer [J. Appl. Phys. 111, 083516 (2012)]. Fundamentally, the former method assumes pressure equilibrium, whereas the latter assumes a common particle velocity and mixture sound speed from compressible two-phase cavitating flows. Additionally, we construct thermodynamically complete equations of state by fitting Einstein oscillator series models for the specific heat at constant volume. Finally, the solid solution approximation is invoked for intermetallic compositions, which are not strictly physical mixtures. Overall, the KEA model provides a better fit to the available Ni x Al y and Ni+Al multilayer shock compression data; however, there are combinations of material properties where the performance of these two models is thought to be reversed. Moreover, the results of this work include the first analytical solution of Jordan–Baer that does not require numerical root finding, as well as proposed modifications to the Einstein oscillator series to incorporate some effects of local pressure–temperature equilibrium and reaction–diffusion. Future work is planned that will use these equations of state in mesoscale simulations to study shock-induced reaction in Ni+Al multilayers, and the intended application is illustrated with a brief 2D hydrocode example.

36 MATERIALS SCIENCE↗

Insight into pseudo-film-boiling in supercritical water under simplified interfacial conditions

The focus of this paper is the physics of supercritical water film boiling through the simulation of natural convection of supercritical water in a rectangular cavity. It has been widely believed that above a fluid's critical point, only one phase exists. However, recent research has indicated the existence of distinct gas-like and liquid-like regions separated by the Widom line, which is the locus of the maxima of the specific heat. Along the Widom line, density decreases sixfold, viscosity drops by a factor of two, while specific heat spikes by an order of magnitude. These variations, specifically in density and viscosity, produce a thick pseudo-interface and flow dynamics behavior akin to film-boiling, denoted here as pseudo-two-phase flow dynamics. When the cavity is heated from the bottom, a pseudo-film of gas-like fluid is formed at the heated wall, and the flow complexity evolves, characterized by the formation of multiple vortices. Results demonstrate the ability of modern conjugate heat transfer computational fluid dynamics to capture the pseudo two-phase regime, with the formation of a pseudo-film at the heated wall. Further, the boiling curve is studied, showing an increase in heat flux with an increase in the temperature differential between the wall and the pseudo-critical temperature. Furthermore, results also show a previously uncharacterized instability, where the convection cells in the cavity oscillate and can flip directions under certain conditions.

Computational fluid dynamics↗

Effect of the volume fraction gradient on the phase interaction force model for disperse two-phase flows

In this work, the effects of the particle volume fraction gradient on fluid-particle interactions are studied. The phase interaction force is decomposed into three terms. For the first term, namely the symmetrized force density, we present theoretical reasoning and numerical evidence to assume that it is independent of the particle volume fraction gradient. The second term is the particle volume fraction gradient times a newly introduced diffusion stress. The third term is the divergence of the particle-fluid-particle (PFP) stress. If this assumption of independence of the particle volume fraction gradient for the first term can be verified, to the first order of the ratio of the mean distance between particles to the macroscopic lengthscale, all three terms can be studied and modeled in flows with uniform particle distributions. Models thus obtained are applicable to statistically inhomogeneous flows, with the second and third terms accounting for statistical inhomogeneity. To verify this assumption, numerical simulations of flows passing fixed arrays of particles are performed. Both uniform and nonuniform particle volume fractions are studied and compared for disperse multiphase flows with the particle Reynolds numbers ranging from 1 to 100, and particle volume fraction ranging from 1% to 26% in statistically steady states. It is found that the symmetrized force (first) term can be well approximated by the drag force obtained from studies of uniform flows. The diffusion stress is positive along the flow direction and negative in the directions perpendicular to the flow. In the case of moving particles, this stress could potentially cause particle aggregation in the flow direction and dispersion in the directions perpendicular to the flow. Finally, the diffusion stress is only important when there is a volume fraction gradient, while the PFP stress can be important in inhomogeneous flows with either nonuniform particle concentrations or nonuniform average relative velocities between the phases.

42 ENGINEERING↗

Three and Two Phase Rotating Field Inductive Couplers for Wireless Power Transfer with One Phase per Layer Windings

Multiphase inductive wireless charging coils have been proposed recently to improve coupler surface power density, reduce component stress and size, and provide near-constant power delivery to charge mobile electric systems. Several aspects for the fundamental characterization of multiphase coils are explored up to six phases including approximate mutual inductance with size and turn variation, induced voltage, and output power estimation. The relative component stress and size of passive components for resonant operation are compared between the multiphase variants. A combination of an experimentally validated 3D electromagnetic finite element analysis (FEA) and power electronic co-simulations are used to validate the estimated quantities approximated with a mixture of analytical equations and an artificial neural network model for mutual inductance. A novel three-phase transmitter, two-phase receiver coil pair is also proposed for electric vehicle charging to reduce the number of connections and compensation complexity on the vehicle-side with improved power output compared to a two-phase configuration.

Lewis, Donovin D. [University of Kentucky]↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗