Search NASA⌕ Search

SEARCH · Search NASA

Results for “ultrasensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ultrasensitive single-cell proteomics workflow identifies >1000 protein groups per mammalian cell

Here, we report on the combination of nanodroplet sample preparation, ultra-low-flow nanoLC, high-field asymmetric ion mobility spectrometry (FAIMS), and the latest-generation Orbitrap Eclipse Tribrid mass spectrometer for greatly improved single-cell proteome profiling. FAIMS effectively filtered out singly charged ions for more effective MS analysis of multiply charged peptides, resulting in an average of 1056 protein groups identified from single HeLa cells without MS1-level feature matching. This is 2.3 times more identifications than without FAIMS and a far greater level of proteome coverage for single mammalian cells than has been previously reported for a label-free study. Differential analysis of single microdissected motor neurons and interneurons from human spinal tissue indicated a similar level of proteome coverage, and the two subpopulations of cells were readily differentiated based on single-cell label-free quantification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ordered porous RGO/SnO 2 thin films for ultrasensitive humidity detection

In this work, ordered porous thin films of reduced graphene oxide and tin oxide (rGO/SnO 2 ) were synthesized by a polystyrene sphere monolayer colloidal crystal template method, and their gas-sensing properties were systematically studied. The formed amorphous SnO 2 and partially reduced graphene oxide were analyzed using several complementary material characterization techniques. Further, the results show that the incorporation of rGO significantly improved the humidity sensitivity and the electrical conductivity of the sensor relative to the pristine SnO 2 thin film. Fast response time and excellent selectivity towards humidity were also achieved for the rGO/SnO 2 composite film. The long-term stability of the rGO/SnO 2 sensor was confirmed by comparing its performance to a commercial humidity sensor. The enhanced sensor performance is attributed to the synergistic effects of the incorporation of rGO and the ordered porous structure of the composite film.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Contorted acene ribbons for stable and ultrasensitive neural probes

Organic materials that conduct both electrons and ions are integral to implantable bioelectronics because of their conformable nature. There is a dearth of these materials that are highly sensitive to cations, which are the majority ions on the surface of neurons. This manuscript offers a solution using an extended ribbon structure that is defect-free, providing high electronic mobility along its fused backbone, while the edge structure of these ribbons promotes high ionic conductivity. We incorporated these mixed ion/electron conductors into neural probes and implanted them in a rodent brain where they offer a suite of useful properties: high cation sensitivity, stability over several weeks after implantation, and biocompatibility. These materials represent an innovative class of implantable biosensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrasensitive bioluminescent determinations of adenosine triphosphate (ATP) for investigating the energetics of host-grown microbes

Stability and optimal concentrations of reagents were studied in bioluminescence assay of ATP levels. Luciferase enzyme was prepared and purified using Sephadex G-100. Interdependencies between enzyme and luciferin concentrations in presence of optimal Mg are illustrated. Optimal ionic strength was confirmed to be 0.05 M for the four buffers tested. Adapted features of the R- and H-systems are summarized, as well as the percentages of ATP pools released from representative microbes by heat and chloroform.

Hanks, J. H.↗

Ultrasensitive detection of atmospheric trace gases using frequency modulation spectroscopy

Frequency modulation (FM) spectroscopy is a new technique that promises to significantly extend the state-of-the-art in point detection of atmospheric trace gases. FM spectroscopy is essentially a balanced bridge optical heterodyne approach in which a small optical absorption or dispersion from an atomic or molecular species of interest generates an easily detected radio frequency (RF) signal. This signal can be monitored using standard RF signal processing techniques and is, in principle, limited only by the shot noise generated in the photodetector by the laser source employed. The use of very high modulation frequencies which exceed the spectral width of the probed absorption line distinguishes this technique from the well-known derivative spectroscopy which makes use of low (kHz) modulation frequencies. FM spectroscopy was recently extended to the 10 micron infrared (IR) spectral region where numerous polyatomic molecules exhibit characteristic vibrational-rotational bands. In conjunction with tunable semiconductor diode lasers, the quantum-noise-limited sensitivity of the technique should allow for the detection of absorptions as small as .00000001 in the IR spectral region. This sensitivity would allow for the detection of H2O2 at concentrations as low as 1 pptv with an integration time of 10 seconds.

Cooper, David E.↗

Application of reversal electron attachment for ultrasensitive detection of thermal electron-attaching molecules - CCl4 and C6H5O2

A standard gas-dilution method was used to determine the selective response of the reversal electron attachment detector to carbon tetrachloride concentrations in nitrogen. Data are provided that determine the lowest concentration of sample detectable with the present instrumental configuration as being below 1.0 part per trillion by volume. The incorporation of a 90-deg electrostatic deflector with the quadrupole mass spectrometer is shown to be vital, and with it, negative-ion quadrupole mass spectrometry is used to characterize the ionization process. Observations are also made of the reversal electron attachment response to nitrobenzene. The analytical potential of reversal electron capture negative-ion mass spectrometry is examined, and areas for future development are discussed.

Bernius, Mark T.↗

Ultrasensitive Human Radiation Dosimetry

The problem we are addressing concerns the astronauts, and their exposure to radiation during spaceflight. The amount of this radiation is a variable depending on solar events and orbital characteristics. Our goal is to measure the total integrated quantity of radiation damage to the cell nucleus in astronauts or other people exposed to radiation. In my lab, we are turning up the microscope from the level of the chromosome, about eight orders of magnitude, to the molecular level. It is well known that radiation causes DNA and chromosome damage. We are developing methods to measure a specific molecular lesion. The lesion that we have selected to measure is thymidine diol, which is created by hydroxyl radicals adding across the 5.6 double bond of thymidine in DNA.

Hammen, Richard↗

Real-time measurements of endogenous CO production from vascular cells using an ultrasensitive laser sensor

Carbon monoxide (CO) has been implicated as a biological messenger molecule analogous to nitric oxide. A compact gas sensor based on a midinfrared laser absorption spectroscopy was developed for direct and real-time measurement of trace levels (in approximate pmol) of CO release by vascular cells. The midinfrared light is generated by difference frequency mixing of two nearinfrared lasers in a nonlinear optical crystal. A strong infrared absorption line of CO (4.61 microm) is chosen for convenient CO detection without interference from other gas species. The generation of CO from cultured vascular smooth muscle cells was detected every 20 s without any chemical modification to the CO. The sensitivity of the sensor reached 6.9 pmol CO. CO synthesis was measured from untreated control cells (0.25 nmol per 10(7) cells/h), sodium nitroprusside-treated cells (0.29 nmol per 10(7) cells/h), and hemin-treated cells (0.49 nmol per 10(7) cells/h). The sensor also detected decreases in CO production after the addition of the heme oxygenase (HO) inhibitor tin protoporphyrin-IX (from 0.49 to 0.02 nmol per 10(7) cells/h) and increases after the administration of the HO substrate hemin (from 0.27 to 0.64 nmol per 10(7) cells/h). These results demonstrate that midinfrared laser absorption spectroscopy is a useful technique for the noninvasive and real-time detection of trace levels of CO from biological tissues.

Non-NASA Center↗

An Ultrasensitive Hot-Electron Bolometer for Low-Background SMM Applications

We are developing a hot-electron superconducting transition-edge sensor (TES) that is capable of counting THz photons and operates at T = 0.3K. The main driver for this work is moderate resolution spectroscopy (R approx. 1000) on the future space telescopes with cryogenically cooled (approx. 4 K) mirrors. The detectors for these telescopes must be background-limited with a noise equivalent power (NEP) approx. 10(exp -19)-10(exp -20) W/Hz(sup 1/2) over the range v = 0.3-10 THz. Above about 1 THz, the background photon arrival rate is expected to be approx. 10-100/s), and photon counting detectors may be preferable to an integrating type. We fabricated superconducting Ti nanosensors with a volume of approx. 3x10(exp -3) cubic microns on planar substrate and have measured the thermal conductance G to the thermal bath. A very low G = 4x10(exp -14) W/K, measured at 0.3 K, is due to the weak electron-phonon coupling in the material and the thermal isolation provided by superconducting Nb contacts. This low G corresponds to NEP(0.3K) = 3x10(exp -19) W/Hz(sup 1/2). This Hot-Electron Direct Detector (HEDD) is expected to have a sufficient energy resolution for detecting individual photons with v > 0.3 THz at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range is approx. 50 dB.

bolometers↗

Ultrasensitive Superconducting Transition Edge Sensors Based On Electron-Phonon Decoupling

We have successfully fabricated the superconducting transition edge sensor (TES), bolometer technology that centers on the use of electron-phonon decoupling (EPD) to thermally isolate the bolometer. Along with material characterization for large format antenna coupled bolometer arrays, we present the initial test results of bolometer based on EPD designed for THz detection. We have selected a design approach that separates the two functions of photon absorption and temperature measurement, allowing separate optimization of the performance of each element. We have integrated Molybdenum/Gold (Mo/Au) bilayer TES and ion assisted thermally evaporated (IAE) Bismuth (Bi) films as radiation absorber coupled to a low-loss microstripline from Niobium (Nb) ground plane to a twin-slot antenna structure. The thermal conductance and the time constant of these devices have been measured, and are consistent with our calculations. The device exhibits a single time constant at 0.1 K of approx.160 IlS, which is compatible with readout by a high-bandwidth single SQUID or a time domain SQUID multiplexer. The effects of thermal conductance and electrothermal feedback are major determinants of the time constant, but the electronic heat capacity also plays a major role. The NEP achieved in the device described above is 2.5x10(exp -17)W(gamma)Hz. Our plan is to demonstrate a reduction of the volume in the superconducting element to 5 microns x 5 microns in films of half the thickness at Tc = 60mK. By calculation, this new geometry corresponds to an NEP reduction of two orders of magnitude to 2.5x10(exp -19)W/(gamma)Hz, with a time constant of ~130/ls.

Jethava, Nikhil↗

Fabrication of Ultrasensitive Transition Edge Sensor Bolometric Detectors for HIRMES

The high resolution mid-infrared spectrometer (HIRMES) is a high resolving power (R approx. 100,000) instrument operating in the 25-122 micron spectral range and will fly on board the Stratospheric Observatory for Far-Infrared Astronomy (SOFIA) in 2019. Central ot HIRMES are its two transition edge sensor (TES) bolometric cameras, an 8x16 detector high resolution array and a 64x16 detector low resolution array. Both types of detectors consist of MoAu TES fabricated on leg-isolated Si membranes. Whereas the high resolution detectors, with noise equivalent power (NEP) approx. 2 aW/square root of (Hz), are fabricated on 0.45 micron Si substrates, the low resolution detectors, with NEP approx. 10 aW/square root of (Hz), are fabricated on 1.40 micron Si. Here we discuss the similarities and difference in the fabrication methodologies used to realize the two types of detectors.

Detectors↗

Ultrasensitive thermo-mechanical bolometer

A thermo-mechanical bolometer includes a substrate and a sensing component mounted on the substrate. The sensing element comprises (a) at least one thermal-actuation component mounted in parallel with the substrate and (b) a strain sensor mounted on the at least one layer of thermal-actuation component. The at least one thermal-actuation component alone or in combination (a) absorbs electromagnetic waves and converts energy from absorbed electromagnetic waves into a change in temperature and (b) converts the change in temperature into a deformation of the at least one layer. The strain sensor comprises a layer of fragments with a gap space between the fragments, wherein the strain sensor senses the deformation or mechanical movement and exhibits a change in electrical resistance in response to the sensed deformation or mechanical movement.

Lin, Yuxuan↗