Search NASA⌕ Search

SEARCH · Search NASA

Results for “underground”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A quantitative risk assessment framework for fault reactivation in underground hydrogen storage: Coupled simulation and deep learning approach

Underground hydrogen storage (UHS) is emerging as a critical solution for large-scale energy storage. However, like all subsurface fluid injection activities, UHS poses the risk of injection-induced fault reactivation. Accurate risk assessment is essential to ensuring the safety and efficiency of UHS operations. This study presents the development of deep-learning surrogate models for fault reactivation prediction in UHS, trained on a comprehensive database of fully coupled fluid flow-geomechanics simulations. Our findings reveal that analytical models often yield unreliable estimates, with errors up to 54% in the allowable injection pressure, potentially leading to a 40% reduction in UHS operational capacity. The developed surrogate models were incorporated into a quantitative risk assessment (QRA) framework, enabling probabilistic evaluation of fault reactivation risk while accounting for uncertainties in the input variables. Site-specific features, such as horizontal stress gradients, fault’s dip and strike angles, and operational parameters like bottom-hole injection pressure and well-fault distance, were identified as the primary drivers of fault reactivation across various stress regimes. Whereas other hydraulic, geological, and poroelastic reservoir properties were found to have a secondary impact. Notably, we observed that the risk of fault reactivation for a critically oriented fault with a static friction coefficient greater than 0.55 remains below 10% in a normal faulting stress regime. However, the risk significantly increases as the stress regime transitions from normal to strike-slip and ultimately to reverse faulting conditions. These findings underscore the importance of rigorous site characterization and comprehensive QRA evaluations to optimize UHS performance and minimize geomechanical risks.

25 ENERGY STORAGE↗

Underground Test Area (UGTA) Sampling Plan for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nevada National Security Site, Nevada, Revision 2

The purpose of this groundwater sampling plan (referred to herein as “the Plan”) is to describe the approach for collecting and analyzing groundwater samples to meet the objectives of the U.S. Department of Energy (DOE), Environmental Management (EM) Nevada Program’s Underground Test Area (UGTA) Activity. The Plan is focused on the Central and Western Pahute Mesa corrective action units (CAUs 101 and 102), which are currently in the Corrective Action Decision Document (CADD)/Corrective Action Plan (CAP) stage of the Federal Facility Agreement and Consent Order (FFACO) UGTA Strategy. The remaining UGTA CAUs are in the final stage of the UGTA strategy (Closure Report [CR] stage), and monitoring requirements for these CAUs are described in the Federal Facility Agreement and Consent Order Nevada National Security Site Use Restriction Management Plan (DOE/EMNV, 2024a). The Plan supersedes the Nevada National Security Site Integrated Groundwater Sampling Plan and its ensuing Record of Technical Change (ROTC) (DOE/EMNV, 2019b).

54 ENVIRONMENTAL SCIENCES↗

Calendar Year 2024 Underground Test Area Annual Sampling Letter Report, Nevada National Security Site, Nevada, Rev. 1

The Underground Test Area (UGTA) Sampling Plan for Corrective Action Units (CAUs) 101 and 102: Central and Western Pahute Mesa, Nevada National Security Site (NNSS), Nevada (referred to herein as “the Plan”) (DOE/EMNV, 2025) describes the approach for collecting and analyzing groundwater samples to meet the objectives of the U.S. Department of Energy (DOE), Environmental Management (EM) Nevada Program’s UGTA Activity. The Plan is designed to ensure compliance with the UGTA Quality Assurance Plan (QAP) (DOE/EMNV, 2024), and the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended).

54 ENVIRONMENTAL SCIENCES↗

Underground Hydrogen Storage: Transforming Subsurface Science into Sustainable Energy Solutions

As the global economy moves toward net-zero carbon emissions, large-scale energy storage becomes essential to tackle the seasonal nature of renewable sources. Underground hydrogen storage (UHS) offers a feasible solution by allowing surplus renewable energy to be transformed into hydrogen and stored in deep geological formations such as aquifers, salt caverns, or depleted reservoirs, making it available for use on demand. This study thoroughly evaluates UHS concepts, procedures, and challenges. This paper analyzes the most recent breakthroughs in UHS technology and identifies special conditions needed for its successful application, including site selection guidelines, technical and geological factors, and the significance of storage characteristics. The integrity of wells and caprock, which is important for safe and efficient storage, can be affected by the operating dynamics of the hydrogen cycle, notably the fluctuations in pressure and stress within storage formations. To evaluate its potential for broader adoption, we also examined economic elements such as cost-effectiveness and the technical practicality of large-scale storage. We also reviewed current UHS efforts and identified key knowledge gaps, primarily in the areas of hydrogen–rock interactions, geochemistry, gas migration control, microbial activities, and geomechanical stability. Resolving these technological challenges, regulatory frameworks, and environmental sustainability are essential to UHS’s long-term and extensive integration into the energy industry. This article provides a roadmap for UHS research and development, emphasizing the need for further research to fully realize the technology’s promise as a pillar of the hydrogen economy.

25 ENERGY STORAGE↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Earth-catalyzed detection of magnetic inelastic dark matter with photons in large underground detectors

Inelastic dark matter with moderate splittings, $\mathcal{O}$ (few to 150) keV, can upscatter to an excited state in the Earth, with the excited state subsequently decaying, leaving a distinctive monoenergetic photon signal in large underground detectors. The photon signal can exhibit sidereal-daily modulation, providing excellent separation from backgrounds. Using a detailed numerical simulation, we examine this process as a search strategy for magnetic inelastic dark matter with the dark matter mass near the weak scale, where the upscatter to the excited state and decay proceed through the same magnetic dipole transition operator. At lower inelastic splittings, the scattering is dominated by moderate mass elements in the Earth with high spin, especially 27 Al, while at larger splittings, 56 Fe becomes the dominant target. We show that the proposed large volume gaseous detector CYGNUS will have excellent sensitivity to this signal. Xenon detectors also provide excellent sensitivity through the inelastic nuclear recoil signal, and if a future signal is seen, we show that the synergy among both types of detection can provide strong evidence for magnetic inelastic dark matter. In the course we have calculated nuclear response functions for elements relevant for scattering in the Earth, which are publicly available on GitHub.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Efficacy of underground aggregate infiltration beds under a permeable pavement system

Urban areas often face significant flooding challenges due to impermeable surfaces that exacerbate stormwater runoff, making effective stormwater management essential. This study demonstrated that combining pervious concrete pavement systems with underground aggregate storage beds and rain gardens can significantly enhance water infiltration and drainage efficiency, providing valuable insights for designing low-impact development strategies in flood-prone regions.

Haselbach, Liv [Lamar Univ., Beaumont, TX (United ↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Laboratory evaluation of cyclic underground hydrogen storage in the Temblor sandstone of the San Joaquin Basin, California

Underground Hydrogen Storage (UHS) in depleted oil and gas reservoirs could provide a cost-effective solution to balance seasonal fluctuations in renewable energy generation. However, data and knowledge on UHS at subsurface conditions are limited so it is difficult to estimate how effective this type of storage could be. In this study, we perform high pressure experiment to measure the effectiveness of cyclic hydrogen (H 2 ) storage in a specimen of Temblor sandstone retrieved from the San Joaquin Basin of California. Our experiment mimics reservoir pressure conditions to measure H 2 -brine relative permeability and fluid-rock interactions over the course of ten charging and discharging cycles. Initial gas breakthrough occurred at 15 % to 25 % H2 saturation in the specimen with 3 % NaCl brine as the resident fluid. Continuing injecting to 4 pore volumes (PV) of H 2 yielded an asymptotic H 2 saturation of 38 % to 41 %, a level often referred to as the irreducible gas saturation based on two-phase flow. The boundary condition in this study mimics the near wellbore region, which experiences bi-directional H 2 flow. This bi-directional flow led to evaporative drying of the specimen resulting in 94 % H 2 saturation at the end of 10th cycle. This indicates that cyclic flow and evaporative drying can lead to more efficient reservoir storage where a larger fraction of the reservoir porosity is usable to store H 2 . The produced gas stream consisted of H 2 mixed with 8 % to 22 % H 2 O, indicating formation dry-out by evaporation. Meanwhile, produced water chemistry indicated calcite and silicate dissolution, with calcite sourced from fossil fragments. This led to a loss of cementation and weakened the rock sample. Combined, our results indicate dry-out, compaction, increased H 2 saturation, rock weakening, and permeability loss during cyclic UHS. Overall, we anticipate that the combined effects should lead to higher than anticipated UHS storage efficiency per volume of sandstone reservoir rock.

08 HYDROGEN↗

Cyclic loading–unloading impacts on geomechanical stability of multiple salt caverns for underground hydrogen storage

Underground caverns in a salt dome are promising geologic features to store hydrogen because of salt’s extremely low permeability and self-healing behavior. The salt cavern storage community, however, has not fully understood the geomechanical behaviors of salt rock driven by quick operation cycles of injection–production, which may significantly impact the cost-effective storage-recovery performance of multiple caverns. Our field-scale generic model captures the impact of cyclic loading–unloading on the salt creep behavior and deformation under different cycle frequencies, operating pressure, and spatial order of operating cavern(s). This systematic simulation study indicates that the initial operation cycle and arrangement of multiple caverns play a significant role in the creep-driven loss of cavern volumes and cavern deformation. Finally, our future study will develop a new salt constitutive model based on geomechanical tests of site-specific salt rock to probe the cyclic behaviors of salt precisely both beneath and above the dilatancy boundary, including reverse (inverse transient) creep, the Bauschinger effect, and damage-healing mechanism.

08 HYDROGEN↗

Strain-Based Assessment of Shale Caprock during Cyclic Underground Hydrogen Storage

Successful large-scale underground hydrogen storage (UHS) in depleted gas reservoirs depends on the integrity of the overlying caprock to prevent hydrogen loss during cyclic injection and depletion. Prior studies on crushed Marcellus shale, a potential caprock, indicate that cyclic hydrogen injection and depletion induces microstructural changes, increasing porosity and permeability. However, the extent of these changes in intact shale remains unclear. This study presents a strain-based experimental approach to quantify volumetric strain evolution in intact Marcellus shale matrix under unconstrained stress conditions. A quadrant-shaped shale sample without visible fractures underwent eight hydrostatic pore-pressure cycles (injection to 1500 psi and depletion to 500 psi in 250 psi steps). Linear strain gauges measured strain in three orthogonal directions. Results indicate progressive plastic strain accumulation, leading to an ∼12% increase in matrix porosity after eight cycles, with an estimated 19% increase after 30 cycles. This porosity increase follows a logarithmic trend, suggesting a diminishing effect in later cycles. Additionally, permeability and diffusive mass flux are projected to rise by ∼70% over 30 cycles, enhancing hydrogen migration risk. The shale matrix also exhibited mechanical stiffening over successive cycles, limiting large-scale deformation but not preventing porosity enhancement. A new parameter, α, was introduced to characterize shale sensitivity to cyclic loading, aiding UHS caprock assessments. These findings underscore the necessity of incorporating cyclic loading effects in UHS site selection and operational strategies to ensure long-term storage integrity.

08 HYDROGEN↗

Deep Learning for Subsurface Flow: A Comparative Study of U‐Net, Fourier Neural Operators, and Transformers in Underground Hydrogen Storage

Subsurface flow research is essential for the sustainable management of natural resources and the environment. Deep learning (DL) has significantly advanced this field by developing efficient and accurate surrogate models to replace computationally expensive physics‐based simulations. These surrogate models are commonly used to predict the spatiotemporal evolution of state variables, such as gas saturation and reservoir pressure, in heterogeneous geological formations. Despite the various DL models applied to this task, there is a lack of studies systematically comparing their performance. This absence of comparative analysis leads to somewhat arbitrary DL model selection in subsurface flow research, resulting in suboptimal performance and potentially inaccurate predictions. To bridge this gap, we conduct a systematic comparison study of three popular DL architectures—U‐Net, Fourier Neural Operators (FNO), and Segmentation Transformer (SETR)—in surrogate modeling of underground hydrogen storage (UHS). We focus on UHS due to its promise of enhancing clean energy resilience and its cyclic operational conditions that represent common scenarios in various subsurface applications. We evaluate the models based on accuracy, training cost, and inference speed. The comparison shows that U‐Net achieves the highest accuracy, followed by SETR and FNO. Despite its lower accuracy, FNO has the highest inference speed. SETR offers competitive accuracy with the least training memory usage, demonstrating the potential of transformers in learning subsurface flow. Our results provide guidance for selecting DL models for surrogate modeling in a wide range of subsurface flow problems.

42 ENGINEERING↗

Characterization of volcanic tuff pores pre- and post-underground nuclear detonation using ultra-small and small angle neutron scattering

The ability to accurately model the subsurface transport of radionuclides is fundamental to the remote detection and characterization of underground nuclear explosion (UNE) events. Developing more sophisticated transport models presents a significant opportunity to enhance monitoring capabilities, particularly in the reliable prediction of signature migration. Experimentally determined characterization of geologic materials associated with transport properties is the pertinent base information for such robust model development and calibration. Here, we report results from an unprecedented study demonstrating changes to the pore and fracture network structures in geological materials in response to UNEs over nanometer to micrometer length scales. Volcanic tuffs of five different lithological formations from pre- and post-UNE environments were collected from the Nevada National Security Site. Combined ultra-small and small-angle neutron scattering techniques were used to characterize the tuff pore structure. The results demonstrate measurable differences in the specific surface area and porosity of samples pre- and post-shot from texturally similar lithological formations, indicating that pore properties can serve as a direct physical signature of a UNE. The results also provide experimentally determined transport parameters in support of advanced model development through the integration of gas migration, hydrodynamic simulations, and geologic framework models.

54 ENVIRONMENTAL SCIENCES↗

Light dark matter constraints from SuperCDMS HVeV detectors operated underground with an anticoincidence event selection

This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g−days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/𝑐 2 , as well as upper limits on dark photon kinetic mixing and axionlike particle axioelectric coupling for masses between 1.2 and 23.3 eV/𝑐 2 . Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross section sensitivity was achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for inelastic boosted dark matter with the ICARUS detector at the Gran Sasso Underground National Laboratory

We present the result of a search for inelastic boosted dark matter using the data corresponding to an exposure of 0.13 kton · year , collected by the ICARUS T-600 detector during its 2012–2013 operational period at the INFN Gran Sasso Underground National Laboratory. The benchmark boosted dark matter model features a multiparticle dark sector with a U ( 1 ) ′ gauge boson, the dark photon. The kinetic mixing of the dark photon with the Standard Model photon allows for a portal between the dark sector and the visible sector. The inelastic boosted dark matter interaction occurs when a dark matter particle inelastically scatters with an electron in the ICARUS detector, producing an outgoing, heavier dark sector state which subsequently decays back down to the dark matter particle, emitting a dark photon. The dark photon subsequently couples to a Standard Model photon through kinetic mixing. The Standard Model photon then converts to an electron-positron pair in the detector. This interaction process provides a distinct experimental signature that consists of a recoil electron from the primary interaction and an associated electron-positron pair from the secondary vertex. After analyzing 4,134 triggered events, the search results in zero observed events. Exclusion limits are set in the dark photon mass and coupling ( m X , ε ) parameter space for several selected optimal boosted dark matter mass sets and cover previously unexplored parameter space. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluating radiation impact on transmon qubits in above and underground facilities

Superconducting qubits can be sensitive to energy deposits caused by cosmic rays and ambient radioactivity. While previous studies have explored correlated effects in time and space due to cosmic ray interactions, we present the first direct comparison of a transmon qubit’s performance measured at two distinct sites: the above-ground SQMS facility (Fermilab, US) and the deep-underground Gran Sasso Laboratory (Italy). Despite the stark difference in radiation levels, we observe a similar average qubit relaxation time of approximately 80 microseconds at both locations. To investigate radiation-induced events, we employ a fast decay detection protocol, comparing the relative rates of events between the two environments. Although intrinsic noise remains the dominant source of errors in superconducting qubits, our analysis revealed a significant excess of radiation-induced events for high-coherence transmon qubits operated above-ground. Finally, using γ-ray sources with increasing activity levels, we evaluate the qubit response in a controlled low-background environment.

De Dominicis, Francesco [GSSI, Aquila; INFN, LNS]↗

Real-time well integrity monitoring in underground gas storage wells using distributed temperature and strain sensing: a field demonstration

Here, this article presents the first successful field demonstration of a combined distributed temperature and strain sensing (DTSS) system installed directly on newly replaced tubing in a 5400-ft-deep operational underground gas storage well. The DTSS system uses a single optical fiber to monitor temperature and strain in real-time, providing a cost-effective solution for long-term well integrity assessment. In this study, the strain–stress correlation of the tubing—representative of material behavior analysis—is investigated as a potential method for monitoring tubing integrity throughout its lifetime. Moreover, the DTSS system’s capability to support both continuous and discrete monitoring is evaluated by comparing future data with historical records, enabling the early detection of issues such as material fatigue, corrosion, or deformation. Overall, the work examines the effectiveness and scalability of the DTSS system for real-time monitoring of well operations and integrity in a newly replaced well.

Distributed Strain Sensing↗

Complementary Subsurface Characterization Methods to Develop a Geologic Model for the EGS Collab Experiment, Sanford Underground Research Facility

The EGS (Enhanced Geothermal Systems) Collab project was performed within the Sanford Underground Research Facility (SURF) with a goal of understanding processes and evaluation of models related to hydraulic stimulation of rock at depth. The present work deals with the development of Testbed 2 where experiments were conducted at a depth of 1.25 km and were located within a well-characterized testbed in a metamorphic, amphibolite host rock. A total of eleven boreholes varying in length between 10.6 m and 81.2 m were continuously cored to develop the testbed. In addition to the continuous coring of the amphibolite host rock, geophysical instrumentation supporting electrical resistivity tomography (ERT), microearthquake (MEQ) detection, and optical fiber providing distributed temperature sensing (DTS) and distributed acoustic sensing (DAS) were installed in the monitoring boreholes, all of which produced a comprehensive complementary suite of characterization and monitoring technologies. Pre-stimulation characterization of the groundwater conditions identified only two hydraulically significant fractures, neither of which transects the central portion of the testbed. Flow and pressure monitoring indicated low preexisting pore pressure conditions likely affected by the mine openings.

15 GEOTHERMAL ENERGY↗