Search NASA⌕ Search

SEARCH · Search NASA

Results for “uniform method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Decommissioning of the V1 Nuclear Power Plant Jaslovske Bohunice - 20270

The paper focuses on introducing the approach and method applied for decommissioning of the V1 nuclear power plant (further the 'V1 NPP') located in Jaslovske Bohunice in the Slovak Republic, to the conference participants. The Paper outlines activities and steps necessary to comply with the requirements contained in the decision of the Slovak government from 1999 regarding the early shutdown of the V1 NPP. The company responsible for the V1 NPP decommissioning is Jadrova a vyradovacia spolocnost, a.s., (further JAVYS) with the State as a sole shareholder. On the basis of the V1 NPP Decommissioning Conceptual Plan, out of four assessed options, JAVYS selected the immediate decommissioning option (the 'IDO') for the V1 NPP. On the basis of multi-criteria analysis, the IDO specified the approach of immediate and continuous dismantling of equipment followed by demolition of buildings and preparation of the site for its further potential use. The IDO also included the summary of technical, environmental, legislative information as well as the determination of assumed costs for decommissioning of the V1 NPP. Prior to commencement of the V1 NPP decommissioning, within the process of termination of operation, activities connected with de-fuelling, monitoring, processing of historical waste and, not to forget, the process of obtaining the license for the V1 NPP decommissioning were executed. JAVYS decided to divide the decommissioning process into two stages. In 2011, JAVYS obtained a license for the first stage of the V1 NPP decommissioning. Within this stage, dismantling of inactive equipment, demolitions of inactive buildings, monitoring of systems and preparatory works for the upcoming stage of decommissioning were implemented. In 2015, in line with the license for the 2. stage of the V1 NPP decommissioning, the activities of decontamination and dismantling of contaminated and active equipment as well as demolitions of remaining buildings began. In this stage radioactive waste (RAW) produced during the decommissioning is to be processed. After decontamination, the material fulfilling the free release criteria is to be released into the environment, the site is to be cleared from the scope of the Atomic Act and released from the surveillance of the national regulators. Future application of certain methods and techniques for decontamination and dismantling in similar environments might bring an added value to the operators. Paper includes a description of best practices for Nuclear Power Plant VVER type reactors decommissioning. Schedule comparison is given to show how the critical path of certain projects is being managed. Application of the International Standard for Decommissioning Costing (ISDC) methodology provides a uniform method which enables comparison of cost estimates to other nuclear facilities under decommissioning. The cost estimate for the V1 NPP decommissioning has been continuously updated based on more advanced and detailed information on the decommissioning activities and projects. Monitoring of progress of the V1 NPP decommissioning is performed via four key-performance indicators. The Earned Value Management (EVM) methodology is used for evaluating time and cost aspect of decommissioning activities while waste conditioning index is calculated by comparing the actually produced waste to planned values of waste for a respective monitored period. Radiological safety index is assessed by comparison of the personnel records on the individual yearly doses received by each respective employee to the boundary value. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary investigations for the option to use fast uniform scanning with compensators on a gantry designed for IMPT

Purpose: In this experimental study, the authors explored the possibility to deliver the dose for proton therapy with fast uniform scanning on a gantry primarily designed for the delivery of conformal beam scanning and IMPT. The uniform scanning submode has been realized without equipment modifications by using the same small pencil beam used for conformal scanning, resulting in reduced realization costs. Uniform scanning has recently been adopted in a few proton therapy centers, as a basic beam delivery solution, and as an alternative to the use of scattering foils. The option to use such a mode to mimic scattering on a full-fledged scanning gantry could be of interest for treating some specific indications and as a possible solution for treating moving targets. Methods: Uniform iso-energy dose layers were painted by fast magnetic scanning alternated with fast energy changes with the gantry beam line. The layers were stacked and repainted appropriately to produce homogeneous three-dimensional dose distributions. A collimator/compensator was used to adjust the dose to coincide laterally/distally with the target volume. In addition, they applied volumetric repainting, since they are confident that this will further mitigate the effects of organ motion as compared with the presently used clinical scanning solutions. With the approach presented in this paper, they can profit from the higher flexibility of the scanning system to obtain additional advantages. For instance the shape of the energy layers can be adjusted to the projected target shape in order to reduce treatment time and neutrons produced in the collimator. The shape of the proximal layers can be shrunk, according to the cross section of the target at the corresponding range. This provides variable range modulation (proximal conformity) while standard scattering only provides fixed range modulation with unnecessary 100% dose proximal to the target. The field-specific hardware for a spherical target volume was mounted on the Gantry 2 nozzle. One field with proximal field size shrinking and one without, each of 1 Gy, were delivered. The dose distributions at different depths were recorded as CCD images of a scintillating screen. Results: The time to scan the volume once was about 4 s and the total delivery time was approximately 30 s. For the field with proximal conformity, dose sparing of up to 25% was measured in the region proximal to the target. A repainting capability of 48 times was achieved on the most distal layer. The proximal layers were repainted more due to the contribution of the plateau dose from the deeper layers. Conclusions: The flexibility of a fast scanning gantry with very fast energy changes can easily provide beam delivery by uniform layer stacking with a significant degree of volumetric repainting and with the benefit of a dose reduction proximal to the target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

All-Speed Methods and Long-Duration Time Integration for Incorporation into the 7-Equation Two-Phase Model

The numerical simulation of multiphase flows in Light Water (Nuclear) Reactors, LWRs, for normal, accident, and off-normal operation, and for operational optimization must cover a huge disparity of transient time durations, from milliseconds to years. In addition, our recent work has shown that the application of classical Riemann approaches, which pervade modern computational fluid dynamics (CFD), suffer numerical accuracy degradation, especially for compressible liquid flows. In this setting, all-speed or Mach uniform methods are need which can be accurately and efficiently integrated over a very large range of time scales. Thus we need a multi-time-scale integration approach to compliment our previously documented multi-spatial-scale approach to multiphase flow modeling. This report briefly summarizes our efforts in these areas.

42 ENGINEERING↗

Ultra-violet Sensing Characteristic and Field Emission Properties of Vertically Aligned Aluminum Doped Zinc Oxide Nanorod Arrays

Ultra-violet (UV) sensing behavior and field emission characteristic have been investigated on vertically aligned aluminum (Al) doped zinc oxide (ZnO) nanorod arrays prepared using sol-gel immersion method. Uniform and high coverage density of ZnO nanorod arrays have been successfully deposited on seeded-catalyst coated substrates. The synthesized nanorods have diameter sizes between 50 nm to 150 nm. The XRD spectra show Al doped ZnO nanorod array has high crystallinity properties with the dominancy of crystal growth along (002) plane or c-axis. UV photoresponse measurement indicates that Al doped ZnO nanorod array sensitively detects UV light as shown by conductance increment after UV illumination exposure. The nanorod array shows good field emission properties with low turn on field and threshold field at 2.1 V/{mu}m and 5.6 V/{mu}m, respectively. The result suggested that Al doped ZnO nanorod arrays prepared by low-cost sol-gel immersion method show promising result towards fabrication of multi applications especially in UV photoconductive sensor and field emission displays.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Conformity of LINAC-Based Stereotactic Radiosurgery Using Dynamic Conformal Arcs and Micro-Multileaf Collimator

Purpose: To assess the conformity of dynamic conformal arc linear accelerator-based stereotactic radiosurgery and to describe a standardized method of isodose surface (IDS) selection. Methods and Materials: In 174 targets, the conformity index (CI) at the prescription IDS used for treatment was calculated as CI = (PIV/PVTV)/(PVTV/TV), where TV is the target volume, PIV (prescription isodose volume) is the total volume encompassed by the prescription IDS, and PVTV is the TV encompassed by the IDS. In addition, a 'standardized' prescription IDS (sIDS) was chosen according to the following criteria: 95% of the TV was encompassed by the PIV and 99% of TV was covered by 95% of the prescription dose. The CIs at the sIDS were also calculated. Results: The median CI at the prescription IDS and sIDS was 1.63 and 1.47, respectively (p < 0.001). In 132 of 174 cases, the volume of normal tissue in the PIV was reduced by the prescription to the sIDS compared with the prescription IDS, in 20 cases it remained unchanged, and in 22 cases it was increased. Conclusion: The CIs obtained with linear accelerator-based stereotactic radiosurgery are comparable to those previously reported for gamma knife stereotactic radiosurgery. Using a uniform method to select the sIDS, adequate target coverage was usually achievable with prescription to an IDS greater than that chosen by the treating physician (prescription IDS), providing sparing of normal tissue. Thus, the sIDS might aid physicians in identifying a prescription IDS that balances coverage and conformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The FLUXNET2015 dataset and the ONEFlux processing pipeline for eddy covariance data

The FLUXNET2015 dataset provides ecosystem-scale data on CO2, water, and energy exchange between the biosphere and the atmosphere, and other meteorological and biological measurements, from 212 sites around the globe (over 1500 site-years, up to and including year 2014). These sites, independently managed and operated, voluntarily contributed their data to create global datasets. Data were quality controlled and processed using uniform methods, to improve consistency and intercomparability across sites. The dataset is already being used in a number of applications, including ecophysiology studies, remote sensing studies, and development of ecosystem and Earth system models. FLUXNET2015 includes derived-data products, such as gap-filled time series, ecosystem respiration and photosynthetic uptake estimates, estimation of uncertainties, and metadata about the measurements, presented for the first time in this paper. In addition, 206 of these sites are for the first time distributed under a Creative Commons (CC-BY 4.0) license. This paper details this enhanced dataset and the processing methods, now made available as open-source codes, making the dataset more accessible, transparent, and reproducible.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Machine learning-based interatomic potential development and phase transition analysis of ferroelectric hafnium dioxide

The ferroelectric phase (𝑃⁢𝑐⁢𝑎⁢2 1 , which is in orthorhombic symmetry) of hafnium dioxide (HfO 2 ) has gained much attention due to its potential applications in nanoelectronics and advanced memory devices. However, its complex phase behavior under external stimuli, such as pressure and temperature, remains a subject of intense investigation. This study focuses on developing a machine learning-based interatomic potential (MLIP) that is trained with data from density-functional theory (DFT) calculations to simulate phase transitions and mechanical properties of HfO 2 . The developed MLIP predicts lattice parameters, equations of state, bulk and shear moduli, and elastic constants that closely align with DFT predictions for several phases and at various pressures. Once validated, the MLIP is used to investigate the phase transitions of ferroelectric HfO 2 (𝑃⁢𝑐⁢𝑎⁢2 1 ) under both isobaric and constant stress conditions at elevated temperatures ranging from 200 to 2500 K. We used several complementary methods, including local symmetry identification, radial distribution function, and x-ray diffraction characterization, to identify interesting phase transitions among several competitive hafnia phases predicted from our simulations. The suggested methods uniformly reveal that under pure deviatoric condition, the system favors a transition from the orthorhombic 𝑃⁢𝑐⁢𝑎⁢2 1 phase to a tetragonal (𝑃⁢4 2 /𝑛⁢𝑚⁢𝑐) phase, whereas a zero stress condition drives the system from the 𝑃⁢𝑐⁢𝑎⁢2 1 phase to another orthorhombic (𝑃⁢𝑏⁢𝑐⁢𝑛) phase. These findings provide crucial insights into stress and temperature-induced phase behavior of hafnia, guiding future experimental and theoretical studies for optimizing hafnia-based ferroelectric devices.

Ferroelectric HfO2↗

WE-AB-204-10: Evaluation of a Novel Dedicated Breast PET System (Mammi-PET)

Purpose: To evaluate the performance characteristics of a novel dedicated breast PET system (Mammi-PET, Oncovision). The system has 2 detector rings giving axial/transaxial field of view of 8/17 cm. Each ring consists of 12 monolithic LYSO modules coupled to PSPMTs. Methods: Uniformity, sensitivity, energy and spatial resolution were measured according to NEMA standards. Count rate performance was investigated using a source of F-18 (1384uCi) decayed over 5 half-lives. A prototype PET phantom was imaged for 20 min to evaluate image quality, recovery coefficients and partial volume effects. Under an IRB-approved protocol, 11 patients who just underwent whole body PET/CT exams were imaged prone with the breast pendulant at 5–10 minutes/breast. Image quality was assessed with and without scatter/attenuation correction and using different reconstruction algorithms. Results: Integral/differential uniformity were 9.8%/6.0% respectively. System sensitivity was 2.3% on axis, 2.2% and 2.8% at 3.8 cm and 7.8 cm off-axis. Mean energy resolution of all modules was 23.3%. Spatial resolution (FWHM) was 1.82 mm and 2.90 mm on axis and 5.8 cm off axis. Three cylinders (14 mm diameter) in the PET phantom were filled with activity concentration ratios of 4:1, 3:1, and 2:1 relative to the background. Measured cylinder to background ratios were 2.6, 1.8 and 1.5 (without corrections) and 3.6, 2.3 and 1.5 (with attenuation/scatter correction). Five cylinders (14, 10, 6, 4 and 2 mm diameter) each with an activity ratio of 4:1 were measured and showed recovery coefficients of 1, 0.66, 0.45, 0.18 and 0.18 (without corrections), and 1, 0.53, 0.30, 0.13 and 0 (with attenuation/scatter correction). Optimal phantom image quality was obtained with 3D MLEM algorithm, >20 iterations and without attenuation/scatter correction. Conclusion: The MAMMI system demonstrated good performance characteristics. Further work is needed to determine the optimal reconstruction parameters for qualitative and quantitative applications.

60 APPLIED LIFE SCIENCES↗

Metallic Inks for Solar Cells: Cooperative Research and Development (Final Report)

This document describes the statement of work for National Renewable Energy Laboratory (NREL) as a subcontractor for Applied Nanotech, Inc. (ANI) for the Phase II SBIR contract with the Department of Energy to build silicon solar cells using non-contact printed, nanoparticle-based metallic inks. The conductive inks are based upon ANI's proprietary method for nanoparticle dispersion. The primary inks under development are aluminum for silicon solar cell back plane contacts and copper for top interdigitated contacts. The current direction of silicon solar cell technology is to use thinner silicon wafers. The reduction in wafer thickness reduces overall material usage and can increase efficiency. These thin silicon wafers are often very brittle and normal methods used for conductive feed line application, such as screen-printing, are detrimental. The Phase II program will be focused on materials development for metallic inks that can be applied to a silicon solar cell using non-contact methods. Uniform BSF (Back Surface Field) formation will be obtained by optimizing ink formulation and curing conditions to improve cell efficiency.

14 SOLAR ENERGY↗

Updated External Exposure Dose Coefficients

In 2018, the Environmental Protection Agency (EPA) updated and expanded the Federal Guidance Report (FGR) No. 12 to No. 15; tabulating age-specific external exposure effective dose rate coefficients for 1,252 radionuclides in the air, water, and soil (EPA 2018). However, the EPA discovered errors in the tables of dose coefficients for soil which led to the report being retracted for correction. This led to the adoption of “a uniform method of data-smoothing and extrapolation of monoenergetic organ doses at low energies across all exposure pathways; the originally-published dose coefficients utilized different methods for each media type” (EPA 2019). This resulted in all the external exposure dose coefficients being updated and FGR 15 being republished in August 2019 with corrected tables.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A novel approach to mitigating the potential release of radioisotopes under fire conditions - enhancing fire resiliency of radiological contamination fixatives during deactivation & decommissioning activities

Savannah River National Laboratory (SRNL), in close collaboration with the Florida International University Applied Research Center (FIU ARC), successfully executed a technology development activity on behalf of the Department of Energy, Office of Environmental Management (DOE EM). The purpose of the activity was to improve the capability of fixative technologies in immobilizing residual contamination when exposed to thermal stressors as postulated in accident scenarios in Basis for Interim Operations (BIO) documents across the DOE EM complex. The effort resulted in the test and evaluation of a down-selected, commercial-off-the-shelf (COTS) intumescent technology in a radioactive environment at the Savannah River Site (SRS) Building 235-F Plutonium Fuel Form (PuFF) Facility and highlighted the potential use of this technology as a stand-alone, fire retardant fixative. Furthermore, this activity highlighted significant shortfalls in common fixatives currently used to support decommissioning activities and brought to the forefront the need for a methodical, uniformed approach to certifying fixative technologies for operational use in Deactivation and Decommissioning (D&D) activities. An essential component of this research was to evaluate the state of industry fixatives currently in use and set the foundation for comparison to alternative technological solutions. A baseline of five (5) commonly used fixatives and decontamination gels (hereafter collectively referred to as fixatives) was conducted, and notable shortfalls and deficiencies were revealed, particularly when exposed to thermal, water, and other environmental stressors. At temperatures as low as 300 °F - 400 °F (148.89 °C – 204.44 °C), all commonly used fixatives melted from the substrates within 3-5 minutes of exposure, resulting in contaminant transport. Significant degradation in terms of mass loss, desiccation, and off-gassing occurred, and the chemical breakdown of the polymer was so complete researchers assessed there would likely have been a release of residual contamination. Additional vulnerabilities became evident when exposed to water immersion and high humidity; existing fixatives took up water, swelling and frequently delaminating from the substrate, once again increasing the likelihood of a contaminant release.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HEU Pancake (Jemima) Plate Preliminary Characterization Report

The HEU pancake (Jemima) plates have been used in multiple International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluations, including: HEU-MET-FAST-072, HEU-MET-FAST-073, HEU MET-FAST-102, HEU-MET-INTER-006, HEU-MET-INTER-011, HEU-MET-MIXED-021, and IEU MET-FAST-025. This report only focuses on the physical dimension characterization, since concerns have been identified about reliable diameter and height measurements. Historically, height measurements with calipers and mass measurements have been performed for every plate. However, the combination of previous measurements (mass and caliper height measurements) with the drawing dimensions for the diameters led to unrealistic densities (>19 g/cm 3 ) or large ranges of densities for parts that were manufactured at the same time (17 g/cm 3 to >19 g/cm 3 ). Due to the oxidation of the plates, questions about the flatness of each plate and what gaps are introduced into the system have been discussed, since gaps tend to be one of the largest sources of uncertainty in stacked benchmark experiments. The purpose of this report is to characterize a subset of this commonly used fuel. A uniform method for how to define the HEU pancake plates for ICSBEP evaluations will also be proposed with a discussion on what measurements should be performed on the remaining HEU pancake plates in the NCERC inventory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mechanical Properties of Unreinforced Brick Masonry, Section1

Before the advent of concrete and steel, masonry helped build civilizations. From Egypt in Africa, Rome in Europe, Maya in the America to China in Asia, masonry was exploited to construct the most significant, magnificent and long lasting structures on the Earth. Looking at the Egyptian pyramids, Mayan temples, Roman coliseum and Chinese Great Wall, one cannot stop wondering about the significance and popularity that masonry has had through out history. Lourenco et al (1989) summed up the reasons for the popularity of masonry in the following, 'The most important characteristic of masonry construction is its simplicity. Laying pieces of stone or bricks on top of each other, either with or without cohesion via mortar, is a simple, though adequate, technique that has been successful ever since remote ages. Other important characteristics are the aesthetics, solidity, durability, low maintenance, versatility, sound absorption and fire protection' Despite these advantages, masonry is no longer preferred structural material in many parts of the developed world, especially in seismically active parts of the world. Partly, masonry and especially unreinforced masonry (URM) has mechanical properties such as strength and ductility inferior to those of reinforced concrete and steel. Moreover, masonry structures were traditionally built based on rules of thumb acquired over many years of practice and/or empirical data from testing. Accordingly, we do not have a rigorous and uniform method of analysis and design for masonry. Nevertheless, the world still possesses numerous historic and ordinary masonry structures, which require maintenance and strengthening to combat the assault of time and nature. Hence, it is important to study fundamental properties of masonry so that new masonry structures can be effectively designed and built, and the cost for servicing old structures and for building new ones will be less expensive.

36 MATERIALS SCIENCE↗

Quantifying Antibiotic Distribution in Solid and Liquid Fractions of Manure Using a Two-Step, Multi-Residue Antibiotic Extraction

Antibiotic distribution and analysis within liquid and solid fractions of manure are highly variable due to each compound’s respective physiochemical properties. This study developed and evaluated a uniform method extracting 10 antibiotics from 4 antibiotic classes (tetracycline, sulfonamides, macrolides, and β-lactam) from unprocessed manure, solid–liquid separated manure, and composted solids. Through systematic manipulation of previously published liquid chromatography tandem mass spectrometry methods; this study developed an extraction protocol with optimized recovery efficiencies for varied manure substrates. The method includes a two-step, liquid-solid extraction using 10 mL of 0.1 M EDTA-McIlviane buffer followed by 10 mL of methanol. Antibiotics recoveries from unprocessed manure, separated liquids, separated solids, and heat-treated solids using the two-step extraction method had relative standard deviations < 30% for all but ceftiofur. Total antibiotic recoveries were 67–131% for tetracyclines, 56% for sulfonamide, 49–53% for macrolides, and 1.3–66% for β-lactams. This is the first study to use one protocol to assess four classes of antibiotics in liquid and solid manure fractions. This study allowed for more precise risk assessment of antibiotic transport in manure waste stream applied to fields as a liquid or solid compost.

59 BASIC BIOLOGICAL SCIENCES↗

Accelerating Application Bulk Synchronous Writes in HPC Environments

High-bandwidth storage tiers are becoming more common for their capability to absorb high-rate, bursty I/Os. Notably, the designs of these fast storage tiers differ from system to system. The variation of these layers and non-uniform methods of access can pose chal- lenges for applications seeking to run at multiple HPC facilities. Therefore, in this work, we present Spectral, a rapid-output ab- straction library to accelerate application, bulk-synchronous writes on HPC systems. We design Spectral to enable applications to use high-bandwidth storage, such as node-local storage and dis- tributed, write-caches (e.g., burst buffers) transparently without requiring modifications to the application or file system source code. The key idea is to allow applications to spend most of the time performing productive work and to not require any source code changes for maximum portability on different HPC archi- tectures. Spectral internally re-routes write-only files through available, high-performance I/O resources before ultimately mi- grating them to the shared global parallel file system. For instance, on Summit, Spectral transparently places application outputs on node-local storage and then utilizes asynchronous migration to the center-wide GPFS file system. We evaluate Spectral on the Summit HPC system (1024 nodes) using the IOR benchmark and real scientific applications. Spectral shows linear performance scaling, improving application write performance by over an order of magnitude when compared to GPFS.

Khan, Awais↗

uBoost: a boosting method for producing uniform selection efficiencies from multivariate classifiers

The use of multivariate classifiers, especially neural networks and decision trees, has become commonplace in particle physics. Typically, a series of classifiers is trained rather than just one to enhance the performance; this is known as boosting. This paper presents a novel method of boosting that produces a uniform selection efficiency in a selected multivariate space. Such a technique is well suited for amplitude analyses or other situations where optimizing a single integrated figure of merit is not what is desired.

47 OTHER INSTRUMENTATION↗

Uniform convergence of an upwind discontinuous Galerkin method for solving scaled discrete-ordinate radiative transfer equations with isotropic scattering

Here we present an error analysis for the discontinuous Galerkin (DG) method applied to the discrete-ordinate discretization of the steady-state radiative transfer equation with isotropic scattering. Under some mild assumptions, we show that the DG method converges uniformly with respect to a scaling parameter which characterizes the strength of scattering in the system. However, the rate is not optimal and can be polluted by the presence of boundary layers. In one-dimensional slab geometries, we demonstrate optimal convergence when boundary layers are not present and analyze a simple strategy for balance interior and boundary layer errors. Some numerical tests are also provided in this reduced setting.

97 MATHEMATICS AND COMPUTING↗