47 records · Page 3

Toward Tunable Magnetic Dirac Semimetals: Mn Doping of Cd 3 As 2

Magnetic impurities provide a route toward increasing functionality in electronic materials, often enabling new device concepts and architectures. In the case of topological semimetals, dilute magnetic doping presents a particularly attractive approach for inducing a Dirac to Weyl phase change via time reversal symmetry breaking. However, efforts to realize changes in the electronic structure have been limited by challenges in incorporating magnetic impurities into crystals with sufficiently high electron mobilities to detect them via transport or spectroscopic techniques. Here, we demonstrate incorporation of Mn into Cd 3 ⁢As 2 Dirac semimetal thin films grown by molecular beam epitaxy (MBE). Using As-rich growth conditions and [001] oriented thin films, Mn compositions of >10% are achieved. Films contain uniform distributions of Mn with no evidence of secondary phases and exhibit electron mobilities greater than 10 000–30 000 cm 2 /Vs up to 5% Mn. An evolution in the magnetization behavior along with the emergence of a second quantum oscillation frequency at low Mn concentrations provide preliminary evidence of Mn-induced changes in the electronic structure that are consistent with a Weyl phase. This work demonstrates the potential of magnetically doping topological semimetal thin films and a pathway for synthesizing them.

36 MATERIALS SCIENCE

Insights into mixing of non-isothermal multi-polymer melts for complex plastics recycling

Catalytic recycling or upcycling of plastics is often limited not by catalyst performance, but by transport, arising from highly viscous, non-Newtonian polymer melts. In this work, we develop a reactor-scale framework that integrates rheological measurements, constitutive modeling, computational fluid dynamics (CFD), and experiments to quantify mixing, heat transfer, and dispersion in surrogate hydrocarbon melts representing mixed plastics systems. Temperature- and shear rate-dependent viscosity of low-density polyethylene (LDPE) and high-density polyethylene (HDPE) is measured to create two surrogate polymers (PLD and PHD) that capture the dominant shear-thinning flow behavior while neglecting strong elastic effects, enabling tractable simulation of non-isothermal, polymer-melt mixing using a Carreau-Arrhenius generalized Newtonian framework. Three-dimensional CFD simulations are employed to evaluate impeller performance in PLD using mixing time, cavern volume, thermal uniformity, and interfacial area for regimes in which viscoelastic effects are not dominant. We show that magnetic stir bars commonly used in lab-scale studies produce large thermal gradients (~60 °C) and poor mixing, even under idealized power delivery and polymer flow conditions. In contrast, close-clearance anchor impellers achieve near-isothermal operation, reduce mixing times by up to 5×, and provide >90% active circulation volume. We further demonstrate that, at low pseudo-Deborah number (De*), motor power requirements can be predicted directly from shear rate-dependent rheology using the Carreau-Arrhenius framework, enabling rational selection of operating conditions. Extension to surrogate immiscible multi-polymer systems based on PLD and PHD shows that interfacial area is highly sensitive to operating conditions and impeller design, with coaxial anchor-turbine configurations enhancing dispersion by up to 4 × .

Close-clearance impellers

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING

Improving Ionic Conformality Across Polymer Electrolyte|Electrode Interfaces

Maintaining uniform ionic transport at electrode|electrolyte interfaces, i.e., ionic conformality, remains challenging in polymer electrolyte (PE)-based solid-state batteries. Morphological conformality does not necessarily imply ionic conformality. In PEs, which typically consist of a mechanically supporting component and distinct ionically conductive components, the rearrangement or depletion of mobile ion-conductive domains at interfaces can disrupt ionic transport pathways. Such localized ionic depletion contributes to interfacial instability and capacity degradation in high-voltage lithium-metal batteries. Herein, an electrolyte design approach aimed at minimizing interfacial heterogeneities is demonstrated through compositional adjustments, characterized by spatially resolved structural and chemical X-ray techniques and NMR diffusometry to elucidate ion transport dynamics. This approach improves ionic conformality at electrode interfaces, enhancing cycling stability in Li||LiNi 0.8 Co 0.1 Mn 0.1 O 2 (NMC811) coin and pouch cells cycled at high voltages. These results contribute to understanding interfacial behaviors in multiphase PEs and inform strategies for improving stability across solid-state battery interfaces.

36 MATERIALS SCIENCE

Manipulating Na/TM Ratio‐Driven Structural Heterogeneity of O3‐NaNi 1/3 Fe 1/3 Mn 1/3 O 2 Cathode for High‐Voltage Sodium‐Ion Batteries

The stability of O3-type NaNi 1/3 Fe 1/3 Mn 1/3 O 2 under high-voltage cycling is dictated by how synthesis encodes lattice strain and redox heterogeneity. Here, in this study, the role of Na:TM stoichiometry is systematically resolved by tuning the NaOH:precursor ratio during solid-state synthesis. The stoichiometric condition (Na:TM = 1.00) yields minimized microstrain, enabling uniform O3–P3 phase evolution and homogeneous multi-metal redox with preserved octahedral symmetry. In contrast, Na-excess compositions inherit disordered intermediates and heterogeneous distortion fields that trigger abrupt multiphase transitions and promote localized charge redistribution. In situ XRD captures the divergence in phase-transition pathways, TXM resolves particle-level redox heterogeneity, and XANES corroborates a stronger and more reversible Fe redox contribution at stoichiometry, shifting to diminished Fe participation and spatially inhomogeneous redox at higher Na content. These results establish Na:TM stoichiometry as a critical synthesis parameter controlling both structural coherence and redox stability. Electrochemically, the stoichiometric composition exhibits smooth voltage profiles with minimal polarization growth and retains nearly 80% of its initial capacity after 100 cycles even at an extended 4.2 V cutoff, whereas Na-excess compositions show significantly reduced initial coulombic efficiency and rapid voltage fade. Precise stoichiometric tuning provides a scalable route to defect-suppressed O3 frameworks, enabling structurally resilient, high-voltage sodium-layered cathodes.

36 MATERIALS SCIENCE

Improved high-gradient performance for medium-velocity superconducting half-wave resonators: Surface preparation and trapped flux mitigation

A development effort to improve the performance of superconducting radio-frequency half-wave resonators (SRF HWRs) is underway at the Facility for Rare Isotope Beams (FRIB), where 220 such resonators are in operation. Our goal was to achieve an intrinsic quality factor (𝑄 0 ) of ≥ 2 × 10 10 at an accelerating gradient (𝐸 acc ) of 12 MV/m. FRIB production resonators were prepared with buffered chemical polishing. First trials of electropolishing (EP) and post-EP low-temperature baking of FRIB HWRs allowed us to reach higher gradient (15 MV/m, limited by quench) with a higher quality factor at high gradient, but 𝑄 0 was still below our goal. Trapped magnetic flux during the Dewar test was found to be a source of 𝑄 0 reduction. Three strategies were used to reduce the trapped flux: (i) adding a local magnetic shield (LMGS) to supplement the “global” magnetic shield around the Dewar for reduction of the ambient magnetic field; (ii) performing a “uniform cooldown” (UC) to reduce the thermoelectric currents; and (iii) using a compensation coil to further reduce the ambient field with active field cancellation (AFC). The LMGS improved the 𝑄 0 , but not enough to reach our goal. With UC and AFC, we exceeded our goal, reaching 𝑄 0 = 2.8 ×10 10 at 𝐸 acc = 12 MV/m.

Cryogenics & vacuum technology

Staged Z-pinch experiment at the double-EAGLE pulsed power facility

The staged Z-pinch is a potential high-energy gain fusion concept where a high atomic number liner implodes on a deuterium target using a pulsed multi-MA current source. Over the past several years this concept has been studied on 0.5–1.0 MA facilities using Ar and Kr gas puffs injected at R = 1.2 cm. Neutron yield up to (2.5 ± 0.34) x 10 10 was measured, Ruskov et al (2023 IEEE Trans. Plasma Sci. 51 3310–6). Here, in this study, we present experimental results from the 4 MA, 110 ns current rise time Double-EAGLE facility at L3Harris (currently, Fisica Inc.) where a larger radius nozzle created gas density profiles peaked at R = 2.5 cm. Modeling with the MACH2 and FLASH codes indicates that the larger radius allows stronger acceleration of the liner plasma and generation of shock waves that preheat a target plasma layer next to the liner to temperatures $T_i >$1 keV. The resulting counter thermal pressure on the liner plasma limits the growth of the Magneto-Rayleigh–Taylor (MRT) instability at the liner-vacuum boundary and the implosion proceeds in a relatively stable manner. Near bang time the enormous target plasma thermal pressure smoothens the MRT perturbations developed during the earlier implosion stages. Time integrated x-ray pinhole images with cutoff energy of 100 eV confirm that a long (∼3 cm), stable and uniform high energy density plasma column is formed in the final implosion stage. Consistent neutron yield in the 10 10 –10 11 range was measured for both Ar and Kr liners imploding on a deuterium target.

Physics - Plasma physics

Neutron detector response modeling in NOvA

Neutrons can present a significant challenge for neutrino experiments in which energy reconstruction is critical. With the ability to escape detection completely and with a weak correlation between their kinetic energy and any eventual energy deposition, it is difficult to fully account for neutrons produced in neutrino interactions. This in turn leads to significant model dependence when evaluating neutron-related systematic uncertainties. The NOvA experiment is a long-baseline neutrino oscillation experiment with a high-statistics sample of antineutrino data collected by its near detector. We report an excess relative to data of simulated neutron candidates with low energy depositions when using standard Geant4 physics lists. The simulation excess is traced to an overabundance of secondary photons produced from interactions of neutrons with kinetic energy greater than \SI{20}{\mega\eV}. Improved agreement with data is obtained by applying the data-driven neutron-on-carbon \menate model for neutrons between \SI{20}{\mega\eV} and ${\sim}$\SI{100}{\mega\eV}. With \menate, the residual oversimulation is more uniform across the calorimetric neutron energy spectrum, suggesting possible overproduction of primary neutrons by the GENIE neutrino interaction generator. These results motivate the adoption of \menate-supplemented Geant4 simulation as the nominal simulation in the production of future \nova simulation.

Abubakar, S.

Evaluating Polymer Properties with Different Additives for Carbon Capture and Other Applications

Anthropogenic climate change is one of this generation’s most pressing concerns, with the potential to completely alter the delicate balance we’ve struck with nature. Already, global temperatures have risen 1.29°C, leading to disrupted weather systems, extinctions, increased risks of wildfires, and sea level rise, to name a few effects. Carbon dioxide emission from the combustion of fossil fuels and other industrial activity is a large driver of this phenomenon, as it absorbs heat before it can be radiated away from Earth, trapping it. Carbon dioxide has reached unprecedented levels in our atmosphere, showing a 50% increase from preindustrial averages to a whopping 430 ppm. Thus, reducing the amount of carbon dioxide via carbon capture technology is an important endeavor that serves to benefit everyone. The Microencapsulated CO 2 Sorbent (MECS) team at Lawrence Livermore National Laboratory (LLNL) has turned to microencapsulation to approach this endeavor. Microcapsules provide an attractive approach to carbon capture, combining large surface areas for more efficient mass transfer, regenerative abilities, reduced solvent loss, and improved handling. Additionally, while existing carbon capture technology relies on industrial plants, capsules could present a modular approach to carbon capture, reducing the need for extensive physical infrastructure. The MECS team’s design consists of a polymer membrane that contains a liquid carbon sequestering sorbent, aqueous sodium carbonate. The carbon capturing reaction occurs in three distinct steps, the first of which is the dissolution of carbon dioxide into the sorbent solution and its conversion into carbonic acid (H 2 CO 3 ), shown in equations 1 and 2 respectively. Because this step hinges upon the ability of carbon dioxide to reach the solution inside the capsule, it is necessary that the microcapsule shell is permeable to carbon dioxide gas. The MECS team produces these microcapsules using the in-air droplet encapsulation apparatus (IDEA) shown in figure 1, which can produce uniform micron-scale droplets at speeds much faster than traditional single-dispersal microfluidic-based techniques. The IDEA Is 100 times faster than these current techniques and can reach up to 1000 times their speed when incorporating a multi-nozzle design. Additionally, because droplets are produced in-air via vibration, IDEA can decrease post-processing times and material waste by 99% and can fabricate microgels that are 10 to 100 times more viscous than can be produced via traditional microfluidics. While this design represents a breakthrough in the throughput, efficiency, and tunability of microcapsule production, it imposes a major constraint on the microcapsule curing process. Because microcapsule shells are crosslinked with UV light while falling 30 cm through the air, this gives them a reaction window of approximately 0.2 seconds. Thus, the system and shell formulations must be optimized such that the shells can be fully crosslinked within this very narrow window, prompting investigations into curing behavior.

36 MATERIALS SCIENCE

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed

Synthesis‐Related Nanoscale Defects in Mo‐Based Janus Monolayers Revealed by Cross‐Correlated AFM and TERS Imaging

2D Janus transition metal dichalcogenides (TMDs) are promising candidates for various applications including non-linear optics, energy harvesting, and catalysis. These materials are usually synthesized via chemical conversion of pristine TMDs. Nanometer-scale characterization of the obtained Janus materials’ morphology and local composition is crucial for both the synthesis optimization and the future device applications. In this work, we present the results of cross-correlated atomic force microscopy (AFM) and tip-enhanced Raman spectroscopy (TERS) study of Janus monolayers synthesized by the hydrogen plasma-assisted chemical conversion of MoSe 2 and MoS 2 . We demonstrate that the choice of both the growth substrate and the starting TMD influences the residual strain, thereby shaping the nanoscale morphology of the resulting Janus material. Furthermore, by employing TERS imaging, we show the presence of nanoscale islands (≈20 nm across) of MoSe 2 - ${\mathrm{Mo}}_{{\mathrm{Se}}}^{\mathrm{S}}$ (MoS 2 -${\mathrm{Mo}}_{\mathrm{S}}^{{\mathrm{Se}}}$) vertical heterostructures originating from the bilayer nanoislands in the precursor monolayer crystals. The understanding of the origins of nanoscale defects in Janus TMDs revealed in this study can help with further optimization of the Janus conversion process towards uniform and wrinkle-/crack-free Janus materials. Moreover, this work shows that cross-correlated AFM and TERS imaging is a powerful and accessible method for studying nanoscale composition and defects in Janus TMD monolayers.

2D materials