Search NASA⌕ Search

SEARCH · Search NASA

Results for “vacuum tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Neon as a Buffer Gas for a Mercury-Ion Clock

A developmental miniature mercury-ion clock has stability comparable to that of a hydrogen-maser clock. The ion-handling components are housed in a sealed vacuum tube, wherein a getter pump is used to maintain the partial vacuum, and the evacuated tube is backfilled with mercury vapor in a buffer gas. Neon was determined to be the best choice for the buffer gas: The pressure-induced frequency pulling by neon was found to be only about two-fifths of that of helium. Furthermore, because neon diffuses through solids much more slowly than does helium, the operational lifetime of a tube backfilled with neon could be considerably longer than that of a tube backfilled with helium.

Prestage, John↗

Miniaturized Mercury Ion Clock for Ultrastable Deep Space Applications

We have recently completed a prototype ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability ~2-3x10-13 at 1 second, averaging to 10-15 at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2x10-13 at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly 1.5 years with no measurable degradation of ion trapping lifetimes or clock short-term performance. Because the tube is sealed, the Hg source and Neon buffer gas are held indefinitely, for the life of the tube. There is no consumption of Hg in this system unlike in a Cs beam tube where lifetime is often limited by Cs depletion.

mercury ion clocks↗

Charge coupled devices

The results are presented of a program to design, fabricate, and test CCD arrays suitable for operation in an electron-bombarded mode. These intensified charge coupled devices have potential application to astronomy as photon-counting arrays. The objectives of this program were to deliver arrays of 250 lines of 400 pixels each and some associated electronics. Some arrays were delivered on tube-compatible headers and some were delivered after incorporation in vacuum tubes. Delivery of these devices required considerable improvements to be made in the processing associated with intensified operation. These improvements resulted in a high yield in the thinning process, reproducible results in the accumulation process, elimination of a dark current source in the accumulation process, solution of a number of header related problems, and the identification of a remaining major source of dark current. Two systematic failure modes were identified and protective measures established. The effects of tube processing on the arrays in the delivered ICCDs were determined and are reported along with the characterization data on the arrays.

Walker, J. W.↗

Nanoklystron: A Monolithic Tube Approach to THz Power Generation

The authors propose a new approach to THz power generation: the nanoklystron. Utilizing silicon micromachining techniques, the design and fabrication concept of a monolithic THz vacuum-tube reflex-klystron source is described. The nanoklystron employs a separately fabricated cathode structure composed of densely packed carbon nanotube field emitters and an add-in repeller. The nanotube cathode is expected to increase the current density, extend the cathode life and decrease the required oscillation voltage to values below 100 V. The excitation cavity is based on ridged-waveguide and differs from the conventional cylindrical re-entrant structures found in lower frequency klystrons. A quasi-static field analysis of the cavity and output coupling structure show excellent control of the quality factor and desired field distribution. Output power is expected to occur through an iris coupled matched rectangular waveguide and integrated pyramidal feed horn. The entire circuit is designed so as to be formed monolithically from two thermocompression bonded silicon wafers processed using deep reactive ion etching (DRIE) techniques. To expedite prototyping, a 600 GHz mechanically machined structure has been designed and is in fabrication. A complete numeric analysis of the nanoklystron circuit, including the electron beam dynamics has just gotten underway. Separate evaluation of the nanotube cathodes is also ongoing. The authors will describe the progress to date as well as plans for the immediate implementation and testing of nanoklystron prototypes at 640 and 1250 GHz.

Siegel, Peter H.↗

Fixed flat plate collector with a reversible vee-trough concentrator

An asymmetrical-reversible vee-trough concentrator for use both with nonevacuated and evacuated receivers is proposed in order to improve the performance of a fixed flat plate collector. The device is capable of maintaining a year-round concentration factor of about 2 while eliminating the complications of the tilt adjustments of the collector box assembly. Efficiency improvements and cost reductions for temperatures of about 100 and 200 C are offered for the nonvacuum and vacuum tube versions, respectively. A major advantage of the vee-trough is the enhancement of the incident flux, thus extending the collection period. The vacuum collector is suitable for supplying heat to solar Rankine systems, while the nonvacuum version can be used for air conditioning purposes via an absorption air conditioner.

Selcuk, M. K.↗

On Predicting Transient Pressure in Vacuum Systems Featuring Getter Materials

Getter materials have been used to reduce pressure or partial pressures in a variety of vacuum applications ranging from vacuum tubes to space flight science instruments. Testing of getter materials has tended to emphasize the capacity of candidate materials to collect specific gas species in sufficient quantities to size them in these applications. When determining a getter material’s capacity, it is typically subjected to enough excess target gas to ensure it sorbs as quickly as possible. However, when both the gas source strength and the getter’s sorption rate exhibit transient decay behavior, such data is not sufficient to predict the targeted species’ partial pressure within a vacuum system as a function of time.

M. S. Woronowicz↗

On Predicting Transient Pressure in Vacuum Systems Featuring Getter Materials

Getter materials have been used to reduce pressure or partial pressures in a variety of vacuum applications ranging from vacuum tubes to space flight science instruments. Testing of getter materials has tended to emphasize the capacity of candidate materials to collect specific gas species in sufficient quantities to size them in these applications. When determining a getter material’s capacity, it is typically subjected to enough excess target gas to ensure it sorbs as quickly as possible. However, when both the gas source strength and the getter’s sorption rate exhibit transient decay behavior, such data is not sufficient to predict the targeted species’ partial pressure within a vacuum system as a function of time.

M. S. Woronowicz↗

On Predicting Transient Pressure in Vacuum Systems Featuring Getter Materials

Getter materials have been used to reduce pressure or partial pressures in a variety of vacuum applications ranging from vacuum tubes to space flight science instruments. Testing of getter materials has tended to emphasize the capacity of candidate materials to collect specific gas species in sufficient quantities to size them in these applications. When determining a getter material’s capacity, it is typically subjected to enough excess target gas to ensure it sorbs as quickly as possible. However, when both the gas source strength and the getter’s sorption rate exhibit transient decay behavior, such data is not sufficient to predict the targeted species’ partial pressure within a vacuum system as a function of time.

Michael Woronowicz↗

Ion pump provides increased vacuum pumping speed

Multiple-cell ion pumps with increased vacuum pumping speed are used for producing ultrahigh vacuums in vacuum tubes and mass spectrometers. The pump has eight cathode-anode magnetron cells arranged in a cylinder which increase the surface area of the cathode.

Source record↗

Chromium oxide coatings improve thermal emissivity of alumina

Chromium oxide coatings improve thermal radiation characteristics of alumina-coated heater-cathode systems in vacuum tubes. Chromium oxide is applied either as a surface layer or as a doping material. The new coatings eliminate the high temperature migration problems of carbon surface treatments.

Upshaw, V.↗

Nonelectric cathode heating.

Vacuum tube with cathode heated directly by external radioisotope source, noting heat pipe providing isothermal heat transfer

Beggs, J. E.↗

Parametric investigation of enclosed keeper discharge characteristics

Volt-ampere discharge characteristics of an enclosed keeper hollow cathode discharge were measured as a function of the mercury flow rate and external circuit impedance. Discharge currents were varied from 0 to 1 ampere and voltages were 7 to 39 volts. Batteries and a vacuum tube control circuit were used to obtain characteristics curves that were independent of power supply impedance. Variation of the neutral flow results in changes in the discharge which interact with the impedance of the external circuit, and under some conditions, give rise to multiple operating points.

Sheheen, T. W.↗

Improved solar-energy collector

Fixed, but reversible, concentrator with vacuum tube receiver is fabricated from individual asymmetrical vee-shaped members having two sides, each of which presents different preselected slope angle to Sun. Trough concentrator maintains year-round concentration factor of 2 (or better) for most significant collection period of day.

Selcuk, M. K.↗

Simple constant-current-regulated power supply

Supply incorporates soft-start circuit that slowly ramps current up to set point at turn-on. Supply consists of full-wave rectifier, regulating pass transistor, current feedback circuit, and quad single-supply operational-amplifier circuit providing control. Technique is applicable to any system requiring constant dc current, such as vacuum tube equipment, heaters, or battery charges; it has been used to supply constant current for instrument calibration.

Priebe, D. H. E.↗

High voltage compliance constant current ballast

A ballast circuit employing a constant current diode and a vacuum tube that can provide a constant current over a voltage range of 1000 volts. The simple circuit can prove useful in studying voltage breakdown characteristics.

Rosenthal, L. A.↗

Projection of distributed-collector solar-thermal electric power plant economics to years 1990-2000

A preliminary comparative evaluation of distributed-collector solar thermal power plants was undertaken by projecting power plant economics of selected systems to the 1990 to 2000 time frame. The selected systems include: (1) fixed orientation collectors with concentrating reflectors and vacuum tube absorbers, (2) one axis tracking linear concentrator including parabolic trough and variable slat designs, and (3) two axis tracking parabolic dish systems including concepts with small heat engine-electric generator assemblies at each focal point as well as approaches having steam generators at the focal point with pipeline collection to a central power conversion unit. Comparisons are presented primarily in terms of energy cost and capital cost over a wide range of operating load factors. Sensitvity of energy costs for a range of efficiency and cost of major subsystems/components is presented to delineate critical technological development needs.

Fujita, T.↗

A two-dimensional thermal analysis of a new high-performance tubular solar collector

The first of two articles are presented which describe and analyze the thermal performance of a vacuum tube solar collector. The assumptions and mathematical modeling are presented. The problem is reduced to the formulation of two simultaneous linear differential equations characterizing the collector thermal behavior. After applying the boundary conditions, a general solution is obtained which is found similar to the general Hottel, Whillier and Bliss form but with a complex flow factor.

Lansing, F. L.↗