Search NASA⌕ Search

SEARCH · Search NASA

Results for “vapor compression refrigeration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Universal Refrigerant Charge Fault Detection and Diagnostics Method Based on Pump Down Operation

The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a universal charge fault detection method which requires only a few experimental data with high prediction accuracy.Currently, pump down operations are typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repairment. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The proposed method innovatively utilizes the typical pump down operation, the compressor low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.The new charge prediction method is firstly formulated through theoretical analysis, then verified and calibrated by a quasi-steady-state simulation of the pump down process for a residential heat pump system. The quasi steady-state simulation uses an HVAC system simulation framework driven by DOE/ORNL Heat Pump Design Model (HPDM). Preliminary experiment validations with heat pump refrigerant leakage tests demonstrate the deviation of the proposed charge prediction method compared with measurement is within 8%. This technology makes refrigerant charge amount available at the technician’s fingertips and leads to shorter maintenance time and fewer site visits.

Li, Zhenning↗

Integrated Thermal Energy Storage System for Air-Conditioners with Phase-Change Composites

Thermal energy storage (TES) is a promising solution to store and dispatch energy and shave peak electric load, reducing the operational cost of HVAC systems. We present results of a TES system using phase-change materials (PCM) integrated with an air conditioner. The proposed system uses an organic PCM (tetradecane) encapsulated within compressed expanded natural graphite foams referred to as phase-change composite. The graphite foam encapsulates the PCM eliminating the need for expensive storage vessels, reduces installation costs, and provides higher thermal conductivity that can lead to faster charge/discharge rates. Two serpentines, multi-pass circuits, operating as a heat source and a sink, exchange heat to and from the phase-change composite. These two circuits are embedded in multiple slabs of this material. The "charge" circuit contains the refrigerant that is directly coupled to a vapor compression system, and the "discharge" circuit removes heat from an airstream and releases it into the PCM composite through a water-glycol liquid coupling. This configuration allows for multiple modes of operation depending on the state of charge of the thermal energy storage module, the building air-conditioning load, and the current electricity and demand charges. This flexible operation allows variable air volume capacity control without the need to have a variable capacity refrigeration system. We developed a 21 kW-hr (6 RT-hr) prototype TES system coupled with a commercial air-conditioner to characterize the component-and system-level performance.

air-conditioning↗

Electrohydrodynamic (EHD) Refrigerant Pump

An electrohydrodynamic (EHD) pump increases refrigerant flow rate and the resulting pressure in a vapor compression based cooling system for permitting reduced compressor sizes and power demands. The EHD pump disposes electrodes in a liquid path of the refrigerant flow, and increases fluid flow and resulting pressure by an induced liquid flow between a pair of asymmetric electrodes. Voltage applied to these electrodes results in a conduction pumping mechanism associated with heterocharge layers in the vicinity of the electrodes based on disassociation of a neutral electrolyte species in the refrigerant fluid and recombination of the generated ions. The induced flow draws the liquid due to a net fluid flow toward one of the electrodes based on the asymmetry of the electrode pair. Electrodes are disposed on an inner surface of a refrigerant vessel, in communication with an annular liquid film that forms around the inner circumference in two-phase fluid systems.

Yagoobi, Jamal S.↗

Advanced Serpentine Heat Exchangers to Minimize Number of Joints and Leakage in HVAC&R Systems

Refrigerant leakage has a significant impact on heating, ventilation, air conditioning and refrigeration (HVAC&R) industries in terms of both greenhouse gas (GHG) emissions and lost efficiency of the systems themselves. One of the major causes of refrigerant leakage is braze joints within a vapor compression system. The brazing process is often inconsistent and almost always imperfect. As a result, braze joints are left vulnerable to leaks and can be weaker than non-brazed tubing. Conventional tube-fin heat exchangers are manufactured using one brazed joint per tube. An alternative to the conventional approach is the use of a single continuous serpentine tube. An Advanced Serpentine Heat Exchanger was developed to provide a heat transfer solution that meets or exceeds performance while also significantly reducing the number of joints and, consequently, the potential for refrigerant leakage. The developed serpentine heat exchanger not only delivers on performance, but is also cost competitive with conventional heat exchangers on the market.

30 DIRECT ENERGY CONVERSION↗

A Comprehensive Review of Working Fluids for High-Temperature Heat Pumps: History, Selection, and Evaluation

High-temperature heat pumps (HTHPs) are essential for enhancing energy efficiency across various industrial applications, especially in terms of integrating with renewable energy sources and recovering waste heat. This article thoroughly investigates suitable working fluids for HTHPs, highlighting the evolution from traditional refrigerants to contemporary alternatives with low global warming potential (GWP). It proposes comprehensive selection criteria for these working fluids, pre-selects low-GWP working fluids, and outlines a screening methodology. The pre-selected low-GWP working fluids are evaluated for applications in three typical industrial scenarios involving HTHPs. Furthermore, this study demonstrates that regulatory compliance and environmental impacts significantly influence the development of next-generation refrigerants. The choice of working fluids is closely linked to the types of vapor compression cycles, tailored to the specific industrial applications for HTHPs. This study emphasizes areas for future research, including the development of innovative working fluids; integrated strategies that account for performance, safety, and regulatory standards; alignment of HTHP components; exploration of natural working fluids; and broadening the applications of existing working fluids.

Compression↗

NFE-24-10417: Durability and Life-time Energy Performance Enhancement of Vapor Compression Systems

This project investigated the use of a Centrifugal Particle Separation (CPS) system to improve the durability and operational reliability of outdoor heat exchangers in vapor-compression based heating, ventilation, air conditioning, and refrigeration (HVACR) systems. The developed method introduced a novel dust and fouling mitigation approach by integrating an ambient air pre-cleaner that employs centrifugal forces to remove particulate matter from incoming air before it reaches the heat exchanger. By reducing the accumulation of dust and debris on coil surfaces, the CPS system aims to lower maintenance requirements and extend equipment lifespan. The project specifically involves coupling a centrifugal air pre-cleaner with a single-zone ductless mini-split system and evaluating its effectiveness in maintaining cleaner coil surfaces. Additionally, the study examined the impact of CPS integration on system energy performance. Through controlled experimental testing and performance monitoring, this work seeks to validate CPS-based air pre-cleaning as a practical, efficient solution for mitigating outdoor coil dust accumulation and fouling in both residential and commercial HVACR applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lunar base heat pump, phase 1

This report describes the Phase 1 process and analysis used to select a refrigerant and thermodynamic cycle as the basis of a vapor compression heat pump requiring a high temperature lift, then to perform a preliminary design to implement the selected concept, including major component selection. Use of a vapor compression heat pump versus other types was based on prior work performed for the Electric Power Research Institute. A high lift heat pump is needed to enable a thermal control system to remove heat down to 275 K from a habitable volume when the external thermal environment is severe. For example, a long-term lunar base habitat will reject heat from a space radiator to a 325 K environment. The first step in the selection process was to perform an optimization trade study, quantifying the effect of radiator operating temperature and heat pump efficiency on total system mass; then, select the radiator operating temperature corresponding to the lowest system mass. Total system mass included radiators, all heat pump components, and the power supply system. The study showed that lunar night operation, with no temperature lift, dictated the radiator size. To operate otherwise would require a high mass penalty to store power. With the defined radiation surface, and heat pump performances assumed to be from 40 percent to 60 percent of the Carnot ideal, the optimum heat rejection temperature ranged from 387 K to 377 K, as a function of heat pump performance. Refrigerant and thermodynamic cycles were then selected to best meet the previously determined design conditions. The system was then adapted as a ground-based prototype lifting temperature to 360 K (versus 385 K for flight unit) and using readily available commercial-grade components. Over 40 refrigerants, separated into wet and dry compression behavioral types, were considered in the selection process. Refrigerants were initially screened for acceptable critical temperature. The acceptable refrigerants were analyzed in ideal single and two-stage thermodynamic cycles. Top candidates were analyzed assuming realistic component limits and system pressure drops, and were evaluated for other considerations such as safety, environmental impact, and commercial availability. A maximum coefficient of performance (COP) of 56 percent of the Carnot ideal was achievable for a three-stage CFC-11 cycle operating under the flight conditions above. The program was completed by defining a control scheme and by researching and selecting the major components, compressor and heat exchangers, that could be used to implement the thermodynamic cycle selected. Special attention was paid to using similar technologies for the SIRF and flight heat pumps resulting in the commercially available equivalent of the flight unit. A package concept was generated for the components selected and mass and volume estimated.

Goldman, Jeffrey H.↗

Scalable and compact magnetocaloric heat pump technology

Magnetocaloric heat pumping (MCHP) promises to be more efficient than traditional vapor compression while also eliminating the deleterious effects of gaseous refrigerants. While MCHP devices have shown the temperature spans and efficiencies needed for different heating and cooling applications, they struggle to become commercially viable due to their large size and mass, and resultant high cost. This paper evaluates a baseline MCHP device and explores methods to boost its system power density (SPD). The key components of the baseline system are the gadolinium packed-particle bed active magnetic regenerator (AMR) and a magnetic source composed of permanent magnets and high permeability magnetic steel. To enhance the SPD, the paper evaluates maximizing the AMR volume, opting for first-order magnetocaloric materials, optimizing the magnet and AMR geometry, and reducing the size of magnets and magnetic steel parts. At larger thermal powers, increasing the AMR diameter and the number of magnetic poles were evaluated. Using finite element models, solid models, and estimates of magnetocaloric material performance, thermal powers ranging from 37 W to 44 kW at a nominal 10 K temperature span were projected, and SPD was estimated to improve from 6 W/kg to 81 W/kg. Neglecting end effects, an upper limit of 114 W/g is estimated. Compared to SPD of off-the-shelf compressors with similar environment temperatures, MCHP power density using gadolinium is competitive up to roughly 200 W of cooling power. This is extended to 1 kW when using LaFeSi alloys and up to 3 kW in the limiting case. In conclusion, these results indicate that the performance and mass of MCHP can match that of compressors, which is a critical step toward cost-competitive magnetocaloric technology.

42 ENGINEERING↗

Development of a near-isothermal transcritical CO 2 compression system with a liquid piston compressor

Compressors are critical components in vapor compression cycle systems, significantly contributing to energy consumption. As global demand for HVAC&R systems rises, enhancing compressor efficiency becomes increasingly vital. This paper introduces a novel liquid piston compressor integrated with a gas cooler for the transcritical CO 2 refrigeration cycle. The liquid piston enables CO 2 refrigerant compression within various types of heat exchangers, facilitating the transfer of compression heat to the heat transfer fluid. By releasing significant heat, this compressor allows for removing or downsizing the traditional gas cooler in the refrigeration system. This paper presents the experimental performance of the first near-isothermal compressor utilizing a liquid piston in a vapor compression cycle. The critical parameters affecting heat transfer are analyzed by using a 1-D simulation model to achieve a near-isothermal compression process. The results show that the developed prototype successfully reduced the compression temperature increase from 95 K to 10 K, achieving 90 % isothermal efficiency. Furthermore, the 1-D simulation results suggest the smaller internal diameter tubes benefit the isothermal efficiency the most.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bringing Fault Detection and Diagnostics (FDD) Tools into the Mainstream: Retro Commissioning and Continuous Commissioning of HVAC and Refrigeration Systems

HVAC systems in the commercial building sector consume about 3.4 quads of energy annually. Of all the HVAC systems, packaged rooftop air–conditioning units (RTUs) provide cooling and heating for over 60 percent of the commercial building floorspace (about 90 billion ft2) in the U.S. and they are a significant source of energy consumption and peak demand. All HVAC systems suffer from faults that impact thermal comfort and increase energy consumption. There are several commercially available Automated Fault Detection and Diagnostic (AFDD) tools on the market that can detect and diagnose faults, and if those faults are corrected, can save significant national energy. However, there are multiple market barriers for these tools including lack of independent verification of their performance in the field in terms of their technical capabilities, ease of use and installation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Feasibility of High-Temperature Heat Pumps for Industrial Drying Process in the US

High-temperature heat pumps are a prospective technology for electrifying and decarbonizing industrial drying processes. This study investigates the technological potential of HTHPs in replacing fossil-fuel burners or steam boilers in industrial spray dryers. The performance of HTHPs with three configurations was investigated, including high high-temperature heat pump boosted with an electric air heater, a steam-generating high-temperature heat pump with multi-stage mechanical vapor compressions, and transcritical high-temperature heat pumps. R1336mzz(Z) is used as the refrigerant in both subcritical and transcritical high-temperature heat pumps, and R717 is used as the working fluid in the mechanical vapor recompression and the heat transfer fluids. Thermodynamic models are built to evaluate the energy efficiency of HTHPs. A case study was carried out on an industrial spray dryer integrated with a waste heat recuperator, where the HTHPs are used to recover precooled air with a dew point of 40℃ and supply heat for drying air at 200℃. For a high-temperature heat pump boosted with an electric air heater, a higher system-level COP is achieved with a high supply temperature from high-temperature heat pump. For a high-temperature heat pump with mechanical vapor recompressions, larger temperature drops in the flashing tank provide higher heat capacities but almost constant values of the coefficient of performance. For a transcritical high-temperature heat pump, an optimum discharge pressure exists for the temperature profiles within the gas cooler and the coefficient of performance. The transcritical high-temperature heat pump provides the best energy efficiency among the three configurations. The theoretical results prove the technical feasibility of high-temperature heat pumps in industrial air-drying applications. .

Wang, Pengtao↗

An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗

Shape optimization and fluid control of near isothermal compressor for transcritical carbon dioxide cycle

The compressor holds great promise for enhanced energy efficiency over a wide range of vapor compression systems (VCS). However, the majority of them focused on liquid refrigerant injection or inter-stage cooling technologies to improve heat transfer. Increasing the heat transfer area provides another perspective to promote heat dissipation, which commonly involves shape optimization whilst bringing some limitations, mainly from the manufacturing side. To fill the research gap, this paper compares the performance of isothermal compressors under different compression chamber shapes and chamber connection configurations. Additionally, the fluid control of the liquid piston was combined with shape optimization to explore the potential for further heat transfer enhancement. The simulation results have demonstrated that the COP improvements can reach up to 9% compared with the baseline case by optimizing the chamber shape and properly controlling the liquid piston speed, which provides a guideline for designing and customizing the isothermal compression chamber.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Review of Modeling Approaches for Predicting Frost Growth and Defrosting on Tube-Fin Heat Exchangers: Preprint

Frost formation and growth on the evaporator surface is a common process that deteriorates the air-refrigerant heat transfer and restricts airflow. This degrades the performance of the vapor compression system by increasing temperature lift and air-side pressure drop. To accurately predict these effects during coil frosting, as well as the energy use and duration of the defrost process, there is a need to estimate the heat and mass transfer, momentum transport, and solid-liquid and liquid-vapor phase change. Therefore, in the past few decades, continuous effort has been made to model frosting and defrosting processes using approaches ranging from empirical correlations to computational fluid dynamic models. To provide a clearer overview for researchers, engineers, and manufacturers in this field, this paper provides a comprehensive literature review for frosting and defrosting models. The paper begins with theoretical background of frost formation and defrost processes, and then reviews the common modeling approaches in literature and their underlying assumptions when trying to account for various physical phenomenon. Based on the literature review, the most critical modeling effort for frost formation is the determination of frost densification rate and frost growth rate. Various methods to predict these two parameters are reviewed. Empirical correlations commonly used for frost density and thermal conductivity are presented and compared. For the defrost process, various multi-stage models have been proposed with different assumptions. Some assume the presence of air gap between the tube wall and the frost, while others consider the melted frost flow due to gravity. We also review physics-based and empirical approaches to integrate defrost models into heat pump models. We conclude by identifying research gaps and providing recommendations.

defrost↗

Perform Life Cycle Energy and GHG Emission Analysis, Select Candidate Refrigerant(s), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Reducing environmental impacts from the energy conversion systems has been an important research topic due to recent severe global climate changes. In residential buildings, the space heating and cooling are main energy consumers, which are relying on vapor compression based heat pumps. To mitigate the environmental impacts of residential systems, the heat pumps using low-GWP refrigerants and 5mm-tube heat exchangers are proposed to replace the conventional 9 mm or 7 mm tube heat exchangers. This research uses a simulation-based design method to optimize the refrigerant circuitries of a 5-ton low-GWP refrigerant heat pumps whose indoor and outdoor heat exchangers adopt 5 mm tubes. Heat pump systems using four commercially available low-GWP refrigerants (R454A, R454C, ARM20A and ARM20B) are optimized and compared with the baseline R410A system. The results indicate that directly replacing 9 mm tubes into 5mm tubes in the baseline systems induces heat pump performance degradation; by optimizing the 5 mm tube heat pumps with added tube rows, the system refrigerant charge is reduced up to 33% compared with the baseline; the optimized low-GWP 5 mm tube heat pumps offer the same or higher performance under both cooling and heating mode; that under cooling mode, the EER improvement is up to 10.7% and under heating mode the COP improvement is up to 3.4%; and a smart flow control device to maintain counter-flow circuitry pattern on both operating modes can improve the heating performance of 5 mm tube optimized system by up to 3.0%. In an effort to better understand the environmental impacts of these systems, life cycle climate performance (LCCP) evaluation method is used to assess the baseline and optimized systems. LCCP considers the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. Our analyses indicate that the optimized systems using 5mm tubes and low-GWP refrigerants can reduce life-cycle CO 2 emission significantly. And improving system efficiency is the most effective way to reduce the emission of low-GWP refrigerant systems. This report shows that using 5 mm diameter tubes in heat exchangers is a feasible approach to develop heat pumps with low-GWP refrigerants. Using the proposed design approach can yield higher system efficiency with lower environmental impact.

42 ENGINEERING↗

Large room-temperature elastocaloric effect in a bulk polycrystalline Ni-Ti-Cu-Co alloy with low isothermal stress hysteresis

Creation of high-performance advanced elastocaloric materials is essential for the execution of elastocaloric refrigeration that can be an environment-friendly and high-efficiency substitute for the widely used traditional vapor-compression cooling technology. Here we have developed a bulk polycrystalline Ni-Ti-Cu-Co shape memory alloy exhibiting large elastocaloric effect, low stress hysteresis and room temperature working temperature, all of which are of great importance to and urgently demanded for high-efficiency room-temperature elastocaloric refrigeration. This newly developed (Ni 42.5 Ti 50 Cu 7.5 ) 99 Co 1 alloy shows a large room-temperature elastocaloric effect with directly measured adiabatic temperature change up to -14.4 K during unloading. The stress hysteresis of the isothermal superelastic stress-strain curve is as low as 60 MPa when the maximum tensile strain is 2.7%. Owing to the large elastocaloric effect and low stress hysteresis, a very high coefficient of performance up to 19 is achieved on the material level. This newly developed (Ni 42.5 Ti 50 Cu 7.5 ) 99 Co 1 alloy is a robust candidate for efficient elastocaloric refrigeration. Advanced in-situ synchrotron high-energy X-ray diffraction technique was employed to reveal the phase transformation sequence and to accurately determine the crystal structure of different phases, based on which the lattice compatibility between the transforming phases was evaluated and the phase transformation strain was predicted, providing in-depth fundamental understanding of the martensitic transformation in this newly developed alloy. This work could be useful for designing high-performance elastocaloric materials for solid-state cooling applications.

36 MATERIALS SCIENCE↗

Integration of Thermoelectric Modules to Vapor Compression Systems

This paper describes the technology of a thermoelectric (TE) integrated heat pump. It uses a TE heat pump to subcool the refrigerant liquid before entering the evaporator to enlarge the evaporating capacity; and elevate the heat in the refrigerant flow to a supplemental heating coil and discharge the capacity to the indoor air flow. Using the DOE/ORNL Heat Pump Design Model, four system configurations were modelled on a baseline two-speed heat pump, the baseline heat pump with adding a supplemental coil, the TE integrated heat pump having one stage TE heating to control a 20R liquid refrigerant temperature drop; and having two stages TE heating to control up to 40R temperature drop. The system models were used to produce performance curves for EnergyPlus building energy simulations. We selected template residential buildings, poorly insulated: pre-1990 buildings, and well-insulated: IECC2021 buildings; in five cold climate zones: 5A, 5B, 6A, 6B, 7. The building energy simulations demonstrated energy saving potentials, utility cost reductions and estimated payback periods.

Shen, Bo↗