Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable data rates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The two-dimensional diagnostic model for tropospheric OH - An uncertainty analysis

Tropospheric OH is believed to play a major role in atmospheric photochemistry, and, via its chemical interactions OH ultimately may affect the climate, stratospheric ozone levels, and the pH of rain. A valuable tool for predicting the global OH abundance as a function of latitude and altitude is the two-dimensional diagnostic model for tropospheric OH. This model can also be applied to budget studies of species which interact with OH, such as CH4, CO, and O3. In addition to laboratory-obtained kinetic data, important variables include the rate constants for several reactions, the rate of heterogeneous removal of soluble species, and the global abundance and spatial variability in H2O, O3, CO, and NOx. The uncertainties in these parameters imply over a factor of 3 variability in the calculated global OH concentration as well as significant uncertainties in the latitudinal and vertical OH distribution.

Chameides, W. L.↗

Flight-test experience in digital control of a remotely piloted vehicle.

The development of a remotely piloted vehicle system consisting of a remote pilot cockpit and a ground-based digital computer coupled to the aircraft through telemetry data links is described. The feedback control laws are implemented in a FORTRAN program. Flight-test experience involving high feedback gain limits for attitude and attitude rate feedback variables, filtering of sampled data, and system operation during intermittent telemetry data link loss is discussed. Comparisons of closed-loop flight tests with analytical calculations, and pilot comments on system operation are included.

Edwards, J. W.↗

A fixed/variable bit-rate data compression architecture

A VLSI architecture for an adaptive data compression encoder capable of sustaining fixed or variable bit-rate output has been developed. There are three modes of operation: lossless with variable bit-rate, lossy with fixed bit-rate and lossy with variable bit-rate. For lossless encoding, the implementation is identical to the USES chip designed for Landsat 7. Obtaining a fixed bit-rate is achieved with a lossy DPCM algorithm using adaptive, nonuniform scalar quantization. In lossy mode, variable bit-rate coding uses the lossless sections of the encoder for post-DPCM entropy coding. The encoder shows excellent compression performance in comparison to other current data compression techniques. No external tables or memory are required for operation.

Zweigle, Gregary C.↗

Accounting for the Speed-Accuracy Trade-Off in Quantifying Human-In-The-Loop Error Probabilities

Human-in-the-loop (HITL) simulations cannot collect enough data from human operators to validate estimates of error probabilities for task components. Error rates for tasks have been estimated by using laboratory data for error rates depending on variables such as the cognitive complexity of the task. The limited channel capacity of human operators compels error rates to be strongly related to the time available for the task, the speed-accuracy trade-off. HITL simulations can provide valuable data on the time available for the operator's tasks. We propose that the response times be used in conjunction with measured speed-accuracy curves to estimate the operator error rates contributing to mission failure. Such analyses should be especially important in the estimation of error rates in off-nominal situations.

probability↗

Solar Variability and the Near-Earth Environment: Mining Enhanced Low Dose Rate Sensitivity Data From the Microelectronics and Photonics Test Bed Space Experiment

This effort is a detailed analysis of existing microelectronics and photonics test bed satellite data from one experiment, the bipolar test board, looking to improve our understanding of the enhanced low dose rate sensitivity (ELDRS) phenomenon. Over the past several years, extensive total dose irradiations of bipolar devices have demonstrated that many of these devices exhibited ELDRS. In sensitive bipolar transistors, ELDRS produced enhanced degradation of base current, resulting in enhanced gain degradation at dose rates <0.1 rd(Si)/s compared to similar transistors irradiated at dose rates >1 rd(Si)/s. This Technical Publication provides updated information about the test devices, the in-flight experiment, and both flight-and ground-based observations. Flight data are presented for the past 5 yr of the mission. These data are compared to ground-based data taken on devices from the same date code lots. Information about temperature fluctuations, power shutdowns, and other variables encountered during the space flight are documented.

Turflinger, T.↗

Heart Rate Variability During Early Adaptation to Space

A recent report hypothesized that episodes of space motion sickness (SMS) were reliably associated with low frequency oscillations (less than 0.03 to less than 0.01 Hz) in heart rate variability. This paper archives a large data set for review of investigators in this field which may facilitate the evaluation of this hypothesis. Continuous recording of Electro-cardiography (ECG) and other measures were made for 6 to 12 hours per day (waking hours) of six Shuttle crewmembers for the first 3 mission days of two separate Shuttle flights. Spectral analyses of heart rate variability during approximately 200 hours of inflight is presented. In addition, nearly 200 hours of data collected on these same individuals during ground tests prior to the mission are presented. The Purpose of this Publication is to document the incidence of low frequency oscillations of heart rate in 4 people exposed to microgravity over a period of five days. In addition, this report contains spectral analyses of heart rate data collected on these same individuals during ground-based mission simulations. By archiving these data in this manner, it is our intention to make this information available to other investigators interested in studying this phenomena.

Toscano, W. B.↗

Advances in data compression

A rigorous real-variables treatment of general data compression and encoding problems, centered on formulation and proof of relevant existence theorems and a unified formulation of source coding (both noiseless and with a fidelity criterion) in inaccurately or incompletely specified statistical environments. Difficulties in modeling of sources with unknown or imperfectly known statistical descriptions are analyzed and source codes (SC) are classified (variable-rate noiseless SC, fixed-rate noiseless SC) and analyzed, along with types of code sequences (weighted-universal, maximin-universal, strongly or weakly minimax-universal). Universal coding on video data, variable-rate coding with distortion, and distortion-rate functions are discussed. Design strategies for universal coding algorithms are suggested, but the article is not oriented to specific methods of synthesizing data compression systems.

Davisson, L. D.↗

A study of 60 Gigahertz intersatellite link applications

Applications of intersatellite links operating at 60 GHz are reviewed. Likely scenarios, ranging from transmission of moderate and high data rates over long distances to low data rates over short distances are examined. A limited parametric tradeoff is performed with system variables such as radiofrequency power, receiver noise temperature, link distance, data rate, and antenna size. Present status is discussed and projections are given for both electron tube and solid state transmitter technologies. Monolithic transmit and receive module technology, already under development at 20 to 30 GHz, is reviewed and its extension to 60 GHz, and possible applicability is discussed.

Anzic, G.↗

A study of 60 GHz intersatellite link applications

Applications of intersatellite links operating at 60 GHz are reviewed. Likely scenarios, ranging from transmission of moderate and high data rates over long distances to low data rates over short distances are examined. A limited parametric tradeoff is performed with system variables such as radiofrequency power, receiver noise temperature, link distance, data rate, and antenna size. Present status is discussed and projections are given for both electron tube and solid state transmitter technologies. Monolithic transmit and receive module technology, already under development at 20 to 30 GHz, is reviewed and its extension to 60 GHz, and possible applicability is discussed.

Anzic, G.↗

Global radiation damage at 300 and 260 K with dose rates approaching 1 MGy s[superscript -1]

Global radiation damage to 19 thaumatin crystals has been measured using dose rates from 3 to 680 kGy s{sup -1}. At room temperature damage per unit dose appears to be roughly independent of dose rate, suggesting that the timescales for important damage processes are less than {approx}1 s. However, at T = 260 K approximately half of the global damage manifested at dose rates of {approx}10 kGy s{sup -1} can be outrun by collecting data at 680 kGy s{sup -1}. Appreciable sample-to-sample variability in global radiation sensitivity at fixed dose rate is observed. This variability cannot be accounted for by errors in dose calculation, crystal slippage or the size of the data sets in the assay.

59 BASIC BIOLOGICAL SCIENCES↗

Cardiopulmonary data-acquisition system

Computerized system controls and monitors bicycle and treadmill cardiovascular stress tests. It acquires and reduces stress data and displays heart rate, blood pressure, workload, respiratory rate, exhaled-gas composition, and other variables. Data are printed on hard-copy terminal every 30 seconds for quick operator response to patient. Ergometer workload is controlled in real time according to experimental protocol. Collected data are stored directly on tape in analog form and on floppy disks in digital form for later processing.

Crosier, W. G.↗

UV variability and the nature of the continuum source in NGC5548

The short-wave UV continuum of NGC5548 varied quasi-periodically during the IUE monitoring from December 1988 to August 1989. The spectral index of this SWP continuum varied in tight correlation with it, inviting comparison with models to search for clues to the physical nature of the continuum source. The observed covariation of spectral index and continuum are consistent with the model of a black body of constant area (that of a sphere the size of Neptune's orbit) but variable temperature ( 18,000K to 25,000 K). A thin accretion disk around a black hole may also be consistent with this data if the accretion rate can be variable on time scales of 100 days while remaining uniform across the disk. There is marginal evidence for hysteresis in which spectral index changes lead changes in the SWP flux, although the CCF peaks at zero time lag.

Stoner, R. E.↗

Retrospective analysis of pulse oximeter alarm settings in an intensive care unit patient population

Background: The cacophony of alerts and alarms in a hospital produced by medical devices results in alarm fatigue. The pulse oximeter is one of the most common sources of alarms. One of the ways to reduce alarm rates is to adjust alarm settings at the bedside. This study is aimed to retrospectively examine individual pulse oximeter alarm settings on alarm rates and inter- and intra- patient variability. Methods: Nine hundred sixty-two previously collected intensive care unit (ICU) patient records were obtained from the Multiparameter Intelligent Monitoring in Intensive Care II Database (Beth Israel Deaconess Medical Center, Boston, MA). Inclusion criteria included patient records that contained SpO 2 trend data sampled at 1 Hz for at least 1 h and a matching clinical record. SpO 2 alarm rates were simulated by applying a range of thresholds (84, 86, 88, and 90 %) and delay times (10 to 60 s) to the SpO 2 data. Patient records with at least 12 h of SpO 2 data were examined for the variability in alarm rate over time. Results: Decreasing SpO 2 thresholds and increasing delay times resulted in decreased alarm rates. A limited number of patient records accounted for most alarms, and this number increased as alarm settings loosened (the top 10 % of patient records were responsible for 57.4 % of all alarms at an SpO 2 threshold of 90 % and 15 s delay and 81.6 % at an SpO 2 threshold of 84 % and 45 s delay). Alarm rates were not consistent over time for individual patients with periods of high and low alarms for all alarm settings. Conclusion: Pulse oximeter SpO 2 alarm rates are variable between patients and over time, and the alarm rate and the extent of inter- and intra-patient variability can be affected by the alarm settings. Personalized alarm settings for a patient’s current status may help to reduce alarm fatigue for nurses.

59 BASIC BIOLOGICAL SCIENCES↗

The magnetic, basal, and radiative-equilibrium components in Mount Wilson Ca II H + K fluxes

Mount Wilson Ca II H + K flux measurements of cool dwarf stars are analyzed and compared with stellar Mg II h + k fluxes, variability amplitudes, rotation rates, and solar data. It is concluded that the Mount Wilson Ca II H + K fluxes comprise three principal parts: (1) a photospheric contribution in the line wings, (2) a basal chromospheric component that appears to be unrelated to stellar magnetic activity and is, therefore, possibly nonmagnetic in origin, and (3) a chromospheric component which is associated with magnetically active regions and the (quiet and active) network. The basal chromosphere appears to cover the entire surface of magnetically inactive stars. The basal Ca II H + K flux density for solar-type stars equals the average emission observed in the centers of solar supergranulation cells, where the magnetic flux density is small.

Schrijver, C. J.↗

Nimbus 6 satellite vs rawinsonde capabilities

The paper establishes rms errors in Nimbus 6 satellite data from discrepancies between satellite and rawinsonde data, compares rms errors in Nimbus 6 with those in rawinsonde data, and examines the capability of Nimbus 6 satellite data to depict such quantities as horizontal gradients of basic variables and computed variables such as vorticity and lapse rate of temperature. The capability of Nimbus 6 data is illustrated by comparisons of rms errors in computed variables obtained through a propagation-of-error method with average and near-extreme values of the variables obtained from two of NASA's Atmospheric Variability Experiments (AVE II and AVE IV). It is shown that the rms errors in Nimbus 6 basic variables (temperature, mixing ratio, geopotential height, and wind speed) are between 2 and 12 times larger than the corresponding errors in rawinsonde data. For all variables examined, the magnitude of the rms errors are smaller than the near-extreme values of the variables determined from AVE II and AVE IV data.

Scoggins, J. R.↗

Variability of Load and Net Load in Case of Large Scale Distributed Wind Power

Large scale wind power production and its variability is one of the major inputs to wind integration studies. This paper analyses measured data from large scale wind power production. Comparisons of variability are made across several variables: time scale (10-60 minute ramp rates), number of wind farms, and simulated vs. modeled data. Ramp rates for Wind power production, Load (total system load) and Net load (load minus wind power production) demonstrate how wind power increases the net load variability. Wind power will also change the timing of daily ramps.

17 WIND ENERGY↗

Fracture Characterization in Enhanced Geothermal Systems by Wellbore and Reservoir Analysis

This report highlights the work that was done to characterize fractured geothermal reservoirs using production data. That includes methods that were developed to infer characteristic functions from production data and models that were designed to optimize reinjection scheduling into geothermal reservoirs, based on these characteristic functions. The characterization method provides a robust way of interpreting tracer and flow rate data from fractured reservoirs. The flow-rate data are used to infer the interwell connectivity, which describes how injected fluids are divided between producers in the reservoir. The tracer data are used to find the tracer kernel for each injector-producer connection. The tracer kernel describes the volume and dispersive properties of the interwell flow path. A combination of parametric and nonparametric regression methods were developed to estimate the tracer kernels for situations where data is collected at variable flow-rate or variable injected concentration conditions. The characteristic functions can be used to calibrate thermal transport models, which can in turn be used to predict the productivity of geothermal systems. This predictive model can be used to optimize injection scheduling in a geothermal reservoir, as is illustrated in this report.

15 GEOTHERMAL ENERGY↗