Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable speed drive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Hierarchical Speed Planner for Automated Vehicles: A Framework for Lagrangian Variable Speed Limit in Mixed-Autonomy Traffic

Here, this article presents a novel hierarchical speed planning framework for variable speed limits in mixed-autonomy traffic environments, leveraging server-side macroscopic control and vehicle-side microscopic execution. The framework integrates real-time traffic state estimation (TSE) and reinforcement learning (RL)-based control to mitigate congestion and improve traffic flow. A TSE enhancement module combines macroscopic data from sources like INRIX with high-resolution observations from connected autonomous vehicles (CAVs), enabling predictive modeling to address latency and noise. The target speed design module employs kernel smoothing and a buffer zone strategy to optimize traffic density and flow around bottlenecks. The proposed system was validated in the largest open-road test to date with 100 CAVs, demonstrating an overall 8% traffic density decrease, with a specific decrease of 7% upstream, 10% downstream, and a 52% decrease during the congestion formation phase at bottlenecks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

South Texas Industrial Assessment Center (Final Report)

The South Texas Industrial Assessment Center (ST-IAC) provides small to mid-size manufacturing companies and water treatment plants in the Rio Grande Valley of Texas, free energy assessments to help them reduce costs and stay competitive for sustainable development. The ST-IAC operates within the University of Texas Rio Grande Valley (UTRGV), and is the largest Hispanic-serving IAC in the U.S. Created in 2016, the ST-IAC, situated in the most economically disadvantaged region in the country, has been successful in training students and assessing local industries served by a predominantly Hispanic population. UTRGV, now the second largest Hispanic Serving Institution (HSI) of higher education in the U.S., has a student population of 32,000, of which 90% is Hispanic. While Covid-19 had a negative impact to our program during Budget Periods (BP) 4 and 5, the center still managed to provide opportunities for individuals, manufacturing and water industries in the local region. The program developed an energy engineering program in the region and further advanced national priorities. Those include resilience and sustainability of operations by implementing energy efficiency processes, renewable energy sources, decarbonization, battery storage, and cybersecurity in south Texas.

14 SOLAR ENERGY↗

Gearbox and Drivetrain Models to Study Dynamic Effects of Modern Wind Turbines: Preprint

Wind turbine drivetrains consist of components that directly convert kinetic energy from the wind to electrical energy. Guaranteeing robust and reliable drivetrain designs is therefore important to minimize turbine downtime. Current drivetrain models often lack the ability to model both the impacts of electrical transients as well as wind turbulence and shear in one package. In this work, thecapability of the FAST wind turbine computer-aided engineering tool, developed by the National Renewable Energy Laboratory, is enhanced through integration of a dynamic model of the drivetrain. The dynamic drivetrain model is built using Simscape in the MATLAB/Simulink environment and incorporates detailed electrical generator models. This model can be used in the future to test advanced controlschemes to extend life of the gearbox.

17 WIND ENERGY↗

Prototyping of a Rotary Triboelectric Nanogenerator for Power at Sea

Increasing at-sea power generation by Triboelectric Nanogenerator (TENG) energy harvesters towards the order of 1-Watt will create significant opportunities to power ocean observation buoys and distributed sensor nodes by extending mission time and increasing sensor payload. Of the many possible configurations of harvesting wave energy with TENGs, we document the rationale for choosing and developing a rotary TENG that operates by the freestanding mode. The rotary TENG prototype consists of two plates, a rotor and a stator, to take advantage of the various mechanisms of converting wave action into rotational motion. We have constructed a testing apparatus that allows us to vary several key parameters of the device: distance between rotor and stator, triboelectric material, rotational speed, number of electrodes and output load impedance. Preliminary results show that when driven at a constant 500 rpm, we can achieve a power density of 0.7 W/m3. A variable speed motor drives the rotor, which can be driven using a velocity profile informed by the equivalent to the output from a wave energy converter (WEC). The optimized rotational TENG can be stacked and driven by a single shaft, increasing the energy density of the device. The output of such a TENG could be used to power devices in the ocean at a low cost and high durability.

electrostatic generator↗

Chapter 18: Variable Frequency Drive Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

An adjustable-speed drive (ASD) includes all devices that vary the speed of a rotating load, including those that vary the motor speed and linkage devices that allow constant motor speed while varying the load speed. The Variable Frequency Drive Evaluation Protocol presented here addresses evaluation issues for variable-frequency drives (VFDs) installed on commercial and industrial motor-driven centrifugal fans and pumps for which torque varies with speed. Constant torque load applications, such as those for positive displacement pumps, are not covered by this protocol.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Ulta-Efficient Electric Motors

Electric motors utilize a large amount of electrical energy in utility and industrial applications. Electric motors constructed with high temperature superconducting (HTS) materials have the potential to dramatically reduce electric motor size and losses. HTS motors are best suited for large motor applications at ratings above 1000 horsepower (hp), where the energy savings from the efficiency improvement can overcome the additional power required to keep the superconductors on the rotor cooled. Large HTS based motors are expected to be half the volume and have half the losses of conventional induction motors of the same rating. For a 5000 hp industrial motor, this energy savings can result in $50,000 in operating cost savings over the course of a single year of operation. Since large horsepower motors utilize (or convert) about 30% of the electrical power generated in the United States and about 70% of large motors are candidates for replacement by HTS motors, the annual energy savings potential through the utilization of HTS motors can be up to $1 Billion in the United States alone. Research in the application of HTS materials to electric motors has lead to a number of HTS motor prototypes yet no industrial HTS motor product has yet been introduced. These motor demonstrations have been synchronous motors with HTS field windings, on the rotor. Figure 1-1 shows a solid model rendering of this type of motor. The rotor winding is made with HTS coils that are held at cryogenic temperature by introducing cooling fluid from the cryocooler to the rotor through a transfer coupling. The stator winding is made of copper wire. The HTS winding is thermally isolated from the warm armature and motor shafts by a vacuum insulation space and through the use of composite torque tubes. The stator in Figure 1-1 is an air core stator in that the stator teeth and a small part of the yoke is made up of nonmagnetic material so the magnetic fields distribute themselves as if in air. Between the HTS field winding and the physical air gap is a series of concentric cylinders that act as vacuum insulation space walls as well as conducting paths for induced currents to flow in order to shield the HTS winding and the rotor cold space from time dependent fields. These time dependent fields may be caused by rotor hunting, during a change in motor load, or by non-fundamental component voltages and currents applied by the inverter. These motors are variable speed controlled by the inverter. Common large motor utility and industrial applications are pump and fan drives that are best suited by a variable speed motor. Inverter control of the HTS motor eliminates the need to design the rotor for line starting, which would dump a large amount of heat into the rotor that would then heavily tax the cryogenic cooling system. The field winding is fed by a brushless exciter that provides DC current to the HTS rotor winding. The stator winding is air or water cooled. Technical and commercial hurdles to industrial HTS motor product introduction and customer acceptance include (1) the high cost of HTS wire and the cryogenic cooling system components, (2) customer concerns about reliability of HTS motors, and (3) the ability to attain the loss reduction potential of large HTS motors. Reliance Electric has demonstrated a number of HTS based electric motors up to a 1000 hp, variable speed synchronous motor with an HTS field winding in the year 2000. In 2001 this motor was tested to 1600 hp with a sinusoidal (constant frequency) supply. Figure 1-2 shows the HTS motor on the dynamometer test stand in the Reliance Electric test lab. The extensive test program of the 1000 hp motor successfully demonstrated the technical feasibility of large HTS motors and the basic technologies involved, however the test results did indicate the need for design refinements. In addition, test results served to identify other more fundamental critical technology issues, and revealed the need to continue research efforts in order to improve future HTS motor first cost, reliability, and performance. The lessons learned from the development and testing of the 1000 hp motor were the basis for the tasks proposed for the project that is being described in this final report. These eight tasks and the technology and commercial issues they address are listed in Table 1-1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Adjustable Speed Drive Part-Load Efficiency - Motor Tip Sheet #11

An adjustable speed drive (ASD) is a device that controls the rotational speed of motor-driven equipment. Variable frequency drives (VFDs), the most common type of ASDs, efficiently meet varying process requirements by adjusting the frequency and voltage of the power supplied to an AC motor to enable it to operate over a wide speed range. External sensors monitor flow, liquid levels, or pressure and then transmit a signal to a controller that adjusts the frequency and speed to match process requirements.

Industrial, Industry↗

Ultra-Efficient and Power Dense Electric Motors for U. S. Industry

The primary purpose of this project was to combine the ease-of-installation and ease-of-use attributes of industrial induction motors with the low-loss and small size and weight advantages of PM motors to create an ultra-efficient, high power density industrial motor that can be started across-the-line or operated from a standard, Volts/Hertz drive without the need for a rotor position feedback device. PM motor products that are currently available are largely variable speed motors that require a special adjustable speed drive with rotor position feedback. The reduced size and weight helps to offset the magnet cost in order make these motors commercially viable. The scope of this project covers horsepower ratings from 20 - 500. Prototypes were built and tested at ratings ranging from 30 to 250 HP. Since fans, pumps and compressors make up a large portion of industrial motor applications, the motor characteristics are tailored to those applications. Also, since there is extensive use of adjustable frequency inverters in these applications, there is the opportunity to design for an optimal pole number and operate at other than 60 Hz frequency when inverters are utilized. Designs with four and eight pole configurations were prototyped as part of this work. Four pole motors are the most commonly used configuration in induction motors today. The results of the prototype design, fabrication, and testing were quite successful. The 50 HP rating met all of the design goals including efficiency and power density. Tested values of motor losses at 50 HP were 30% lower than energy efficient induction motors and the motor weight is 35% lower than the energy efficient induction motor of the same rating. Further, when tested at the 30 HP rating that is normally built in this 286T frame size, the efficiency far exceeds the project design goals with 30 HP efficiency levels indicating a 55% reduction in loss compared to energy efficient motors with a motor weight that is a few percentage points lower than the energy efficient motor. This 30 HP rating full load efficiency corresponds to a 46% reduction in loss compared to a 30 HP NEMA Premium ® efficient motor. The cost goals were to provide a two year or shorter efficiency-based payback of a price premium associated with the magnet cost in these motors. That goal is based on 24/7 operation with a cost of electricity of 10 cents per kW-hr. Similarly, the 250 HP prototype efficiency testing was quite successful. In this case, the efficiency was maximized with a slightly less aggressive reduction in active material. The measured full load efficiency of 97.6% represents in excess of a 50% loss reduction compared to the equivalent NEMA Premium Efficiency induction motor. The active material weight reduction was a respectable 14.5% figure. This larger rating demonstrated both the scalability of this technology and also the ability to flexibly trade off power density and efficiency. In terms of starting performance, the 30 - 50 HP prototypes were very extensively tested. The demonstrated capability included the ability to successfully start a load with an inertia of 25 times the motor's own inertia while accelerating against a load torque following a fan profile at the motor's full nameplate power rating. This capability will provide very wide applicability of this motor technology. The 250 HP prototype was also tested for starting characteristics, though without a coupled inertia and load torque. As a result it was not definitively proven that the same 25 times the motor's own inertia could be started and synchronized successfully at 250 HP. Finite element modeling implies that this load could be successfully started, but it has not yet been confirmed by a test.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of nonlinear control performance of air handling units under variable operation conditions using root distribution approach

The control systems at Air handling units (AHUs) have nonlinear nature, resulting potentially in sluggish, aggressive, or oscillatory responses under variable operation conditions. This paper is to develop an approach for evaluating the nonlinear control performance of AHUs under variable operation conditions and for identifying the impact of varying multiple operation parameters which guides controller design. To do so, an operation parameter-based root distribution technique, intended to sketch the paths traced by closed-loop poles as multiple operation parameters are varied, is first introduced. The technique—which may be viewed as an extension of conventional, single-variable root locus—is then applied to a fan speed control system that includes a motor with a variable frequency drive and a supply fan with an air duct under variable fan speed and duct static pressure. Using the technique, the system’s stability region is graphically identified. The system is also found to be aggressive and gradually lose its stability as the fan speed decreases and the duct static pressure increases, which is validated by the field tests. Here, the root distribution approach is an effective tool to evaluate the performance of any nonlinear control systems at AHUs with multiple variable operation parameters without requiring time-domain simulations.

42 ENGINEERING↗

Safety evaluation of connected and automated vehicles in mixed traffic with conventional vehicles at intersections

Connected and Automated Vehicles (CAVs) can potentially improve the performance of the transportation system by reducing human errors. This paper investigates the safety impact of CAVs in a mixed traffic with conventional vehicles at intersections. Analyzing real-world AV crashes in California revealed that rear-end crashes at intersections are the dominant crash type. Therefore, to enhance our understanding of the future interactions between human-driven vehicles with CAVs at intersections, a simulation framework was developed to model the mixed traffic environment of Automated Vehicles (AV), cooperative AVs, and conventional human-driven vehicles. In order to model AVs driving behavior, Adaptive Cruise Control (ACC) and cooperative ACC (CACC) models are utilized. Particularly, this study explores system improvements due to automation and connectivity across varying CAV market penetration scenarios. ACC and CACC car following models are used to mimic the behavior of AVs and cooperative AVs. Real-world connected vehicle data are utilized to modify and tune the acceleration/deceleration regimes of the Wiedemann model. Next, the driving volatility concept capturing variability in vehicle speeds was utilized to calibrate the simulation to represent the safety performance of a real-world environment. Two surrogate safety measures are used to evaluate the safety performance of a representative intersection under different market penetration rate of CAVs: the number of longitudinal conflicts and driving volatility. At low levels of ACC market penetration, the safety improvements were found to be marginal, but safety improved substantially with more than 40% ACC penetration. Additional safety improvements can be achieved more quickly through the addition of cooperation and connectivity through CACC. Furthermore, ACC/CACC vehicles were found to improve mobility performance in terms of average speed and travel time at intersections.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of High Rotor Pole Switched Reluctance Motors to Control Condenser Fans in a Commercial Refrigeration System

A high rotor pole switched reluctance motor (HRSRM) designed by Software Motor Corporation was evaluated for use as a condenser fan motor due to its reported high motor efficiency over a broad range of speeds and added advanced control potential. The project was split into two phases; the first of which was to determine the direct energy savings due to the increased motor efficiency, the second was to leverage the additional benefits of the energy efficiency measure (EEM) to create additional energy savings. This report only discusses results from the first phase of the project. Nine 1.5hp HRSRMs were installed parallel to the same number of legacy induction motors of a supermarket commercial refrigeration system located in Lakeside, Colorado. At this site, the 1.5 hp legacy motors had historically adjusted condenser fan speed from 200-870 rpm based on outdoor air temperature and compressor discharge pressure. This type of control is known as variable head pressure control (VHPC). These nine new motors were given a signal from the legacy variable frequency drive (VFD) to match the motor speed of the legacy motors. Determination of the energy savings of the EEM was performed over a two-month period, at which time a correlation between legacy and EEM power consumption was developed based on motor speed. Annual data that had been collected from 2016-2017 (before the two-month test period) was then leveraged to predict the annual energy savings of the EEM for a complete retrofit using both VHPC and constant fan speed control. Table 1 displays the quantitative results. The EEM saved 27% of total energy consumption of the condenser fan motors for constant fan speed control, while the energy savings increased to 32% when using VHPC. This was due to the improved motor efficiency of the HRSR motor at low speeds. While the constant speed fan control kept the motors running at 870 rpm, VHPC adjusted fan speed between 200-870rpm based on the outdoor air temperature and the compressor discharge pressure. These savings are assuming a direct replacement with no additional controls. Retrofitting a constant speed fan control system with HRSRMs and switching to VHPC would provide significant energy savings looking at the condenser alone. Additional considerations of the EEM were noted during the project as well. The HRSRM system made it possible to identify and remotely shutdown an individual motor when a piece of foam locked the fan and thereby the motor. With the traditional system, a locked rotor could have caused motor damage unless a breaker or fuse was activated. Furthermore, due to vibration complaints from the installation technicians, the ramp-up time of the HRSRM had to be increased to a minute. After implementing this change no complaints for excessive vibration were recorded.

15 GEOTHERMAL ENERGY↗

Demonstration of variable speed permanent magnet generator at small, low-head hydro site

Small hydro developers face a limited set of bad choices when choosing a generator for a small low-head hydro site. Direct drive synchronous generators are expensive and technically complex to install. Simpler induction generators are higher speed, requiring a speed increaser, which results in inefficiencies and maintenance problems. In addition, both induction and synchronous generators turn at a fixed speed, causing the turbine to run off its peak efficiency curve whenever the available head is different than the designed optimum head.The solution to these problems is the variable speed Permanent Magnet Generators (PMG). At the Weisenberger Mill in Midway, KY, a variable speed Permanent Magnet Generator has been installed and demonstrated. This new PMG system replaced an existing induction generator that had a HTD belt drive speed increaser system. Data was taken from the old generator before it was removed and compared to data collected after the PMG system was installed. The new variable speed PMG system is calculated to produce over 96% more energy than the old induction generator system during an average year. This significant increase was primarily due to the PMG generator operating at the correct speed at the maximum head, and the ability for the PMG generator to reduce its speed to lower optimum speeds as the stream flow increased and the net head decreased.This demonstration showed the importance of being able to adjust the speed of fixed blade turbines. All fixed blade turbines with varying net heads could achieve higher efficiencies if the speed can be matched to the optimum speed as the head changes. In addition, this demonstration showed that there are many potential efficiencies that could be realized with variable speed technology at hydro sites where mismatched turbine and generator speeds result in lower power output, even at maximum head. Funding for this project came from the US Dept. of Energy, through Award Number DE-EE0005429.

13 HYDRO ENERGY↗

Fractional order PID controller for improvement of PMSM speed control in aerospace applications

Because of the benefits reduced size, cost and maintenance, noise, CO2 emissions and increased control flexibility and precision, to meet these expectations, electrical equipment increasingly utilize in modern aircraft systems and aerospace industry rather than conventional mechanic, hydraulic, and pneumatic power systems. Electric motor drives are capable of converting electrical power to drive actuators, pumps, compressors, and other subsystems at variable speeds. In the past decades, permanent magnet synchronous motor (PMSM) and brushless dc (BLDC) motor were investigated for aerospace applications such as aircraft actuators. In this paper, the fractional-order PID controller is used in the design of speed loop of PMSM speed control system. Having more parameters for tuning fractional order PID controller lead to good performance ratio to integer order. This good performance is shown by comparison fractional order PID controller with the conventional PI and tuned PID controller by Genetic algorithm in MATLAB soft wear.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Data-driven fuel consumption estimation: A multivariate adaptive regression spline approach

Providing guidance and information to drivers to help them make fuel-efficient route choices remains an important and effective strategy in the near term to reduce fuel consumption from the transportation sector. One key component in implementing this strategy is a fuel-consumption estimation model. In this paper, we developed a mesoscopic fuel consumption estimation model that can be implemented into an eco-routing system. Our proposed model presents a framework that utilizes large-scale, real-world driving data, clusters road links by free-flow speed and fits one statistical model for each of cluster. This model includes predicting variables that were rarely or never considered before, such as free-flow speed and number of lanes. We applied the model to a real-world driving data set based on a global positioning system travel survey in the Philadelphia-Camden-Trenton metropolitan area. Results from the statistical analyses indicate that the independent variables we chose influence the fuel consumption rates of vehicles. But the magnitude and direction of the influences are dependent on the type of road links, specifically free-flow speeds of links. Here, a statistical diagnostic is conducted to ensure the validity of the models and results. Although the real-world driving data we used to develop statistical relationships are specific to one region, the framework we developed can be easily adjusted and used to explore the fuel consumption relationship in other regions.

30 DIRECT ENERGY CONVERSION↗

Basal Melting and Oceanic Observations Beneath Central Fimbulisen, East Antarctica

Abstract Basal melting of ice shelves is fundamental to Antarctic ice sheet mass loss, yet direct observations remain sparse. We present the first year‐round melt record (2017–2021) from a phase‐sensitive radar on Fimbulisen, one of the fastest flowing ice shelves in Dronning Maud Land, East Antarctica. The observed long‐term mean ablation rate at 350 m depth below the central ice shelf was 1.0 ± 0.5 m yr −1 , marked by substantial sub‐weekly variability ranging from 0.4 to 3.5 m yr −1 . 36‐h filtered basal melt rate fluctuations closely align with ocean velocity. On seasonal time scales, melt rates peak during austral spring to autumn (September–March), driven by both elevated ocean velocities and thermal driving near the base. The combined effect of thermal driving and current speed explains the majority of the melt rate variability ( r = 0.84), highlighting the dominant role of shear‐driven turbulence. This relationship enables parameterization of melt rates for the decade‐long ocean record (2010–2021), although deviations appear under low and high forcing conditions. Both observed and parameterized melt rates show similar yearly mean magnitudes compared to satellite‐derived melt rates but with a tenfold lower seasonal amplitude and a 3‐month delay in seasonality. These detailed concurrent ice–ocean observations provide essential validation data for remote sensing and numerical models that aim to quantify and project ice‐shelf response to a change in ocean forcing. In situ measurements and continued monitoring are crucial for accurately assessing and modeling future basal melt rates, and for understanding the complex dynamics driving ice‐shelf stability and sea‐level change.

54 ENVIRONMENTAL SCIENCES↗