Unsteady transonic flow calculations are presented for aerodynamically interfering lifting surface configurations. Calculations are performed by extending the XTRAN3S (Version 1.5) unsteady transonic small-disturbance code to allow the treatment of an additional lifting surface. The research was conducted as a first-step toward developing the capability to treat a complete flight vehicle. Grid generation procedures for swept tapered interfering lifting surface applications of XTRAN3S are described. Transonic calculations are presented for wing-tail and canard-wing configurations for several values of mean angle of attack. The effects of aerodynamic interference on transonic steady pressure distributions and steady and oscillatory spanwise lift distributions are demonstrated. Results due to wing, tail, or canard pitching motions are presented and discussed in detail.

Batina, J. T.↗

ChargeX Consortium Presentation at OCPP Plugfest

This is a presentation that outlines the past successes of the INL led Charging Experience Consortium and lists current projects related to vehicle-grid integration. The primary purpose of this presentation is to engage with industry experts and practitioners about the use of the protocol OCPP to enable key improvements to the charging experience for both drivers and the grid.

42 ENGINEERING↗

Integrating Electric Vehicles into the Grid

Historically, transportation and power systems operated independently, but the rise of electric vehicles is transforming this relationship. In the United States, EV demands are expected to become the largest source of electricity load growth, posing challenges for the grid if not properly managed. This presentation highlights how managed charging strategies and strategic infrastructure deployment can integrate EVs into the power system to enhance grid efficiency and support renewable energy.

ADVANCED PROPULSION SYSTEMS,DIRECT ENERGY CONVERSI↗

Grid-Interactive Electric Vehicle and Building Coordination Using Coupled Distributed Control: Preprint

As an increasing number of controllable devices are introduced onto the grid, they can individually provide ancillary services in support of grid stability. However, the goals of each device differ due to their type and individual objectives, causing instances where they may conflict. To reduce the chances of these devices contributing to grid instability, these devices must effectively communicate in a cooperative manner to both meet their own needs while providing services to the grid. Previous work demonstrates that the NALD (Network Lasso-ADMM - Limited Communication - DMPC) algorithm allows coordination between two subsystems that use different control algorithms (building and charging stations) to provide services to the grid and individually optimize their performance in a specific scenario. The ideal NALD algorithm should be generalized to allow plug-and-play capabilities across devices of differing characteristics. This paper takes a step toward generalizability by updating the electric vehicle charging objective and re-defining the communication scheme compared to prior work to generalize the coordination and, as a result, improve the performance of the NALD algorithm.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Gridding strategies and associated results for winged entry vehicles

Two volume grid strategies based on similar software are presented for a geometrically complex entry vehicle. It is shown that quick relatively simple grid generation techniques can be used to construct computational grids about entry vehicles with nontrivial geometric complexity. Particular attention is given to both single- and dual-block grid topologies for a lifting body and solution generated on each grid. Results indicate that the grid topology can have an effect on the nature of the solution.

Weilmuenster, K. J.↗

Grid-Constrained Electric Vehicle Fast Charging Sites: Battery-Buffered Options

This case study summarizes recent Joint Office of Energy and Transportation technical assistance work performed by the National Renewable Energy Laboratory which involved helping a state department of transportation analyze the feasibility of a battery energy storage system solution at a grid-constrained EV charging location.

ADVANCED PROPULSION SYSTEMS↗

Home charging for all: Techno-economic and life cycle assessment of multi-unit dwelling electric vehicle charging hubs

Ubiquitous electric vehicle adoption can drastically reduce greenhouse gas emissions (GHG) but will require equitable home charging infrastructure for all residences. Unlike single-family homes, Multi-Unit Dwellings (MUD) currently lack market share and access to nearby charging infrastructure partly due to expensive capital costs for reluctant residential property-owners. Further, this work evaluates the levelized cost of charging (LCOC) for Battery Electric Vehicles (BEVs) at MUD community charging hubs through a techno-economic analysis (TEA) that leverages real-world charging data and costs. Three different MUD charging types are investigated for a baseline and optimistic case: 1.9-kW Level 1 (L1), 6.6-kW Level 2 (L2), and 50-kW Direct Current Fast Charging (DCFC) stations under three different ownership models: resident, utility, and private company. Results demonstrate L1 and L2 chargers to be less expensive than the gasoline equivalent across the United States. Further, utility and private company ownership models, which avoid initial costs for residential property owners, result in a large LCOC premium for L1 and moderate LCOC premium for L2 relative to the resident ownership model. In contrast, DCFC is shown to be expensive for baseline scenarios but economical for optimistic scenarios especially under private company ownership. This work also performs a cradle to grave (C2G) life cycle assessment (LCA) of an average passenger BEV and gasoline conventional vehicle (CV) using yearly (grid mix & vehicle parameters), hourly (grid mix), and state-level (grid mix) resolution. Results show BEVs to have lower GHG emissions (-86% to-10%) than gasoline CVs in the contiguous U.S. Next, the system boundary of the TEA is extended to the total cost of ownership (TCO) of BEVs. The TCO is then coupled with the C2G GHG emissions to calculate the cost of GHG emissions reduction. Ultimately, the cost of GHG emissions reduction from MUD BEVs relative to gasoline CVs is shown to be negative for every scenario except baseline DCFC, meaning MUD BEV charging infrastructure can be a cost-effective endeavor to reduce GHG emissions.

33 ADVANCED PROPULSION SYSTEMS↗

ChargeX OCPI Recommendations

The Open Charge Point Interface (OCPI) is an open protocol that enables electric vehicle (EV) charging systems to work together across networks. It supports communication and data sharing between Charge Point Operators (CPOs), who manage charging stations, and e-Mobility Service Providers (eMSPs), who provide charging services to EV drivers. OCPI facilitates functions like user authorization, remote charge point control, charging session data exchange, and billing through Charge Detail Records (CDRs). This allows EV roaming, so drivers can charge at different networks without multiple accounts. As the EV market grows due to increased adoption and technological advancements, OCPI faces higher demands. This has revealed issues with CDR format consistency, timestamp standardization across regions, transmission of EV-side error codes for troubleshooting, and support for new use cases. These challenges can affect operations and user experience, particularly as the industry starts considering Vehicle-to-Grid (V2G) systems, where EVs supply energy to the grid, and Vehicle-to-Everything (V2X) technologies for broader energy interactions. Using feedback from the ChargeX Diagnostics taskforce discussions, industry 1-on-1 meetings, technical standards, and OCPI’s evolution through versions (e.g., OCPI 2.1.1, 2.2, and 2.2.1), this report identifies these issues and suggests practical recommendations. These aim to improve interoperability, streamline operations, and prepare OCPI for future trends in the EV charging ecosystem.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Aligning Electric Vehicle Customer Charging with Grid Needs

This talk to the National Association of Regulatory Utility Commissioners (NARUC) focuses on "Aligning Electric Vehicle Customer Charging with Grid Needs" to highlight the opportunities associated with managed electric vehicle charging and its value for consumers and the power system. Electric vehicles (EVs) are experiencing a rapid rise in popularity and adoption, and growing EV adoption offers an opportunity to increase electricity demand. With expected widespread EV adoption, supporting charging will require investments in generation, transmission, and distribution systems. Uncoordinated charging of EVs will lead to increased system peak load, possibly exceeding the maximum power that can be supported by distribution systems and generally increasing power system stress. However, vehicles are underutilized assets parked ~96% of the time: managed EV charging can satisfy mobility needs while also supporting the grid. EVs are not a burden for the grid, but a resource: The demand-side flexibility provided by managed EV charging offers significant potential benefits for the grid over multiple timescales and applications., especially for high-renewable systems. Managed charging can support power system planning and operations during normal and extreme conditions, benefitting EV owners and other electricity consumers. Managed charging is shown to consistently provide hundreds of dollars in cost savings per EV each year.

ADVANCED PROPULSION SYSTEMS↗

Emulation and Adversarial Analysis of EV Charging Networks

In the effort of decarbonization and evolution of the modern electrical grid, electric vehicles (EVs) play a key part to transform the grid. However, due to the rapid adoption of EVs and the demand of the charging infrastructure required to power said EVs, risk of a cyber-attack may impose serious consequences. There is a need to analyze and protect the charging ecosystem infrastructure from cyber threats before it reaches wide-scale deployment. In an effort to secure vehicle to grid (V2G) communications, standardization is necessary for continued reliable system operation. The protocol ISO 15118 outlines controls and practices that should be implemented for secure vehicle to grid (V2G) communications. The standard is gaining momentum for American markets as the demand for EV infrastructure grows. The adoption of ISO 15118 in American markets poses several challenges: the deployment of a public key infrastructure (PKI) as outlined within the standard, interoperability of charging different EVs with chargers from different manufactures using the PKI, and scaling the ecosystem to meet the demand while managing risks. This project was created to understand potential cyber and scaling challenges of PKI for EV infrastructure through utilizing a series of emulated components mapping to what exists in the EV ecosystem today, and the components of the PKI that are under development. The key nodes within the emulation that are under development are: electric vehicle (EV), electric vehicle supply equipment (EVSE), charge network operator (CNO), certificate authority (CA), and online certificate status protocol (OCSP) that must all interact using secure and trusted communications. With these emulated components and utilizing orchestration methods to rapidly deploy and scale the components, the ability to analyze risks of the ecosystem and address gaps before the PKI ecosystem is fully deployed to production should yield a more robust and mature production charging infrastructure. Our approach will use a modular architecture of virtual machines within an orchestration platform and will target scales of 100s, 1000s, and 10,000s of entities interacting. The core research questions trying to be answered with this scope of work are: what are the impacts of a rogue CA, what are the risks of certificate revocation list (CRL) management, what is the value of OCSP stapling, what components are vulnerable to DOS attacks, and what test effective payloads may impact the components.

charging ecosystem↗

FUN3D Grid Refinement and Adaptation Studies for the Ares Launch Vehicle

This paper presents grid refinement and adaptation studies performed in conjunction with computational aeroelastic analyses of the Ares crew launch vehicle (CLV). The unstructured grids used in this analysis were created with GridTool and VGRID while the adaptation was performed using the Computational Fluid Dynamic (CFD) code FUN3D with a feature based adaptation software tool. GridTool was developed by ViGYAN, Inc. while the last three software suites were developed by NASA Langley Research Center. The feature based adaptation software used here operates by aligning control volumes with shock and Mach line structures and by refining/de-refining where necessary. It does not redistribute node points on the surface. This paper assesses the sensitivity of the complex flow field about a launch vehicle to grid refinement. It also assesses the potential of feature based grid adaptation to improve the accuracy of CFD analysis for a complex launch vehicle configuration. The feature based adaptation shows the potential to improve the resolution of shocks and shear layers. Further development of the capability to adapt the boundary layer and surface grids of a tetrahedral grid is required for significant improvements in modeling the flow field.

Bartels, Robert E.↗

Spatial Impacts of Electric Vehicle Charging on Power Grid Stability: A Downtown Atlanta Case Study

The rapid increase in electric vehicle (EV) charging demand poses a potential risk to power grid stability, particularly as the spatial distribution of this demand remains underexplored. Existing research often focuses on technical optimization models while overlooking the geographic and human dynamics that affect energy consumption. This study addresses this gap by incorporating mobility data to estimate both building energy use and EV charging demand while also considering geographic factors for a better understanding of grid load. Using agent-based simulations and the Open-Source Distribution System Simulator, the study evaluates the effect of various EV penetration scenarios on grid voltage and unbalance. The results show that, although voltage remains within acceptable limits at lower EV penetration rates, significant voltage drop and unbalance occur as EV penetration exceeds 40%, particularly in residential areas with high charging demand. This study offers a framework for integrating spatial analysis and mobility data in power network simulations, providing insights for future EV infrastructure planning.

Pan, Melrose [ORNL] (ORCID:000000031627448X)↗

Plug-in Electric Vehicle Charging Response Characterization for Grid Integration: Implications for Smart Charge Management

The rapid expansion of plug-in electric vehicles (PEVs) has created a unique challenge for electrical grids due to their significant power demand. At the same time, PEVs also create a unique opportunity to ease their own burden on the power grid, as they create a growing fleet of distributed energy resources capable of providing grid services such as demand response, frequency regulation, and renewable balancing. For aggregators and grid operators to effectively integrate PEVs into grid management, it is essential to first understand and characterize how they would respond in such situations. This study examines 25 models of PEVs across 25 makes, spanning model years from 2013 to 2025, to characterize their responses to the basic controls used in vehicle-grid integration (VGI): stopping, starting, and modulating the charge rate. Each vehicle was tested in a controlled laboratory setting to evaluate its performance in response to varying the maximum allowable current via the SAE J1772 control pilot signal, as well as its response to wake-up commands outlined in SAE J1772. Results show measurable differences across vehicle makes in the accuracy, latency, and precision with which PEVs respond to changes in ampacity, as well as varying sleep and wake-up behavior. The test results show that all vehicles respond to changes in ampacity, though with varying accuracy, precision, latency, and resolution. Wake-up behavior also differs across makes and models. These findings indicate that effective grid integration strategies must account for these differences. The results provide a foundation for understanding current vehicle behavior and advancing smart-charging methods while also highlighting the need for further testing, broader standardization, and manufacturer collaboration to ensure the successful integration of PEVs into the electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinating the electric vehicle transition and electricity grid decarbonization in the U.S. is not essential to achieving substantial long-term carbon dioxide emissions reductions

Abstract How quickly the US can decarbonize light-duty vehicle (LDV) transportation depends on the rates of change of electric vehicle (EV) sales, stock turnover, and grid decarbonization. We build a stock turnover model to assess how sensitive achieving 2050 LDV decarbonization targets is to these rates. We estimate carbon dioxide (CO 2 ) reductions of 70%–85% by 2050, including emissions from vehicles and upstream electricity generation, provided that new vehicle sales transition to 100% EVs and substantial grid decarbonization are accomplished by 2050. This result is robust to continuation of long-term trends of increasing vehicle longevity, and to whether the timing of EV sales growth and grid decarbonization are coordinated. If the two key goals are met, the annual contribution of EV electricity use to CO 2 emissions will be small over the entire period.

Leard, Benjamin↗

Single block three-dimensional volume grids about complex aerodynamic vehicles

This paper presents an alternate approach for the generation of volumetric grids for supersonic and hypersonic flows about complex configurations. The method uses parametric two-dimensional block-face grid definitions, within the framework of GRIDGEN2D. The incorporation of a face decomposition reduces complex surfaces to simple shapes. These simple shapes are recombined to obtain the final face definition. The advantages of this method include the reduction of overall grid generation time through the use of vectorized computer code, the elimination of generating matching block faces, and simplified boundary conditions.

Alter, Stephen J.↗

Single block three-dimensional volume grids about complex aerodynamic vehicles

This paper presents an alternate approach for the generation of volumetric grids for supersonic and hypersonic flows about complex configurations. The method uses parametric two dimensional block face grid definition within the framework of GRIDGEN2D. The incorporation of face decomposition reduces complex surfaces to simple shapes. These simple shapes are combined to obtain the final face definition. The advantages of this method include the reduction of overall grid generation time through the use of vectorized computer code, the elimination of the need to generate matching block faces, and the implementation of simplified boundary conditions. A simple axisymmetric grid is used to illustrate this method. In addition, volume grids for two complex configurations, the Langley Lifting Body (HL-20) and the Space Shuttle Orbiter, are shown.

Alter, Stephen J.↗

DSMC Grid Methodologies for Computing Low-Density, Hypersonic Flows About Reusable Launch Vehicles

Two different grid methodologies are studied for application to DSMC simulations about reusable launch vehicles. One method uses an unstructured, tetrahedral grid while the other uses a structured, variable-resolution Cartesian grid. The relative merits of each method are discussed in terms of accuracy, computational efficiency, and overall ease of use. Both methods are applied to the computation of a low-density, hypersonic flow about a winged single-stage-to-orbit reusable launch vehicle concept at conditions corresponding to an altitude of 120 km. Both methods are shown to give comparable results for both surface and flowfield quantities as well as for the overall aerodynamic behavior. For the conditions simulated, the flowfield about the vehicle is very rarefied but the DSMC simulations show significant departure from free-molecular predictions for the surface friction and heat transfer as well as certain aerodynamic quantities.

Wilmoth, Richard G.↗

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.