Search NASA⌕ Search

SEARCH · Search NASA

Results for “ventilation controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Brilliant Execution of Smart Labs: Employing Best Practices to Improve Safety and Reduce Energy for Sustainable Labs: Preprint

Laboratory buildings often dominate the energy use on research campuses, consuming three to four times the energy of a typical office building. In most cases, these facilities are defined as “mission critical,” with excessive energy use as simply an unfortunate truth that cannot be avoided without compromising safety. However, case studies indicate cost savings opportunities of up to 40% in laboratories (compared to standard practices) by employing energy efficient design strategies that also improve the safety of lab spaces (Better Buildings 2018). To help stakeholders implement improvement measures, the Smart Labs Toolkit describes a proven approach to optimizing performance of laboratories and critical control environments in new or existing facilities. The Toolkit outlines distinct phases for building a successful Smart Labs program that include: Plan, Assess, Optimize, and Manage. Each phase has specific tasks, training videos, and resources to educate users, support the efforts of key stakeholders, and maximize benefits for the organization in implementing high-performance labs. The Toolkit also includes case studies from the 17 Better Buildings Smart Labs Accelerator partners, sharing lessons learned and supporting the Smart Labs approach to safe, efficient world class science. This paper reviews the technology choices for implementing Smart Labs ventilation strategies, controls, and other efficiency measures. Better Building Smart Lab Accelerator partners provide case study examples of safety and energy-savings results of using Smart Labs approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nationwide Energy Saving Potential Evaluation for Office Buildings with Occupant-Based Building Controls

The heating ventilation and air-conditioning (HVAC) system is a major contributor to building energy consumption. This paper aims to quantify the nationwide energy savings potential of implementing the occupancy-based control (OBC) for the HVAC system in typical medium-sized office buildings using a whole building simulation program (i.e., EnergyPlus). First, the medium-sized office from the DOE Commercial Prototype Building Models was modified to have detailed layout and space functions. Then, a statistic-algorithm-based tool was used to generate the dynamic occupancy schedules for various rooms. Next, both a baseline case and two OBC cases were created for the comparison based on the updated ASHRAE Standard 90.1 and ASHRAE Guideline 36. The HVAC operation in the baseline case follows a static occupancy schedule and fixed setpoint schedules for both room air temperatures and minimal system outside air flowrates, while the proposed OBC cases use the room temperature reset, system minimum outdoor airflow reset, and zone minimal supply airflow rate reset. These cases were extended to five climate zones in the United States to further quantify the energy savings potential associated with the OBC on a nationwide scale. The preliminary result of this case study shows that there could be significant energy savings potential from the proposed OBC strategies in medium-sized office buildings in the United States.

Pang, Zhihong↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Real-time Agent Based Optimization and Control Approach for Residential Building Heating Ventilation and Air Conditioning Systems

The prevalence of the loT (Internet of Things) is fostering the development of new control options and decision making that was not previously available. This is creating a wealth of opportunities for real-time control approaches and systems that can optimize for a common goal. This paper presents a smart residential neighborhood with optimization at the residential level utilizing a system of agents. The optimization utilizes information and modeling to optimize variable speed HVAC real-time operation in actual residential buildings. Data is presented showing the performance of the optimization and conclusions are drawn on next steps for development.

Hall, Joni↗

Lighting controls: not just for lighting anymore!

For the last few years, networked lighting controls (NLCs) have promised significant energy savings beyond what is achieved through a basic LED retrofit. At the same time, NLCs can substantially increase the cost and complexity of the lighting retrofit. And as lighting system wattage declines because of the increasing efficiency of LEDs, advanced controls have less lighting energy to save and the cost-effectiveness of the NLC investment decreases. But NLCs can be leveraged to achieve significant energy savings and value by enhancing control of other building systems. Integrating NLC with control of heating, ventilation and air conditioning (HVAC), plug load control, space utilization, and grid services all enhance the value of your NLC investment. There are already a few NLC products on the market that are capable of providing these enhanced benefits. Manufacturers and entrepreneurs are working hard to expand the impact of these products. But does system interoperability work? Can it be deployed at scale? Slipstream, NEEA and Pacific Northwest National Laboratory (PNNL) have all been attempting to answer these questions in recent pilot projects and describe the outcomes in this paper.

Hackel, Scott↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Consumer Guide to Durable Attics

Learn about controlling moisture and ventilation in your attic, as well as the steps to create a durable attic. This fact sheet from Energy Saver includes information on why moisture control in attics is important and the strategies you can use to control moisture and ventilation in your attic.

attic, moisture, ventilation, Energy Saver↗

Weather responsive smart ventilation system using multiple optimization parameters

A smart ventilation system which uses outdoor temperature and moisture to optimize control of the system. The main principle is to shift ventilation from time periods that have large indoor-outdoor temperature and moisture differences to periods when these differences are smaller, and their energy and comfort impacts are expected to be less. Fan flow rates are reduced when the outside temperature and moisture falls outside of optimum levels, yet overall air exchange is maintained to ensure chronic and acute exposure to pollutants remains relative to best practice. Online weather and smart thermostat data can be used as control inputs, so no specific measurement devices are needed to control ventilation fans.

Parker, Danny↗

Integrated heat and energy recovery ventilator system

A heat recovery ventilator (HRV) and/or energy recovery ventilator (ERV) that integrates with a residential capacity air handling unit (AHU) is embodied in a small footprint HRV or ERV unit that connects directly to the return side of an AHU and to outdoor air inlet and exhaust ducts. The ventilator includes a control system incorporating a processor and sensors that control the operation of the system to provide desired ventilation flow rates under varying conditions.

Puttagunta, Srikanth↗

Dynamic Simulation Modeling and Control of a Desiccant Assisted Direct-expansion Air Handling Unit

Desirable built environments demand simultaneous regulation of thermal comfort and indoor air quality (IAQ) with energy-efficient operation of heating, ventilation and air conditioning (HV AC) systems, which involves controls of temperature, humidity and airborne contaminants simultaneously. This paper presents the efforts of dynamic modeling and initial development control strategy for a desiccant-assisted multi-functional air handling unit (AHU) coupled with a direct-expansion rooftop unit (RTU) system, which aims to achieve multiple functions for indoor environment conditioning with energy efficient control. The RTU-AHU system includes a desiccant wheel for dehumidification and a conceptual direct air capture (DAC) filtering device for CO2 regulation. A Modelica-based dynamic model is developed for this conceptual system, and a simple decentralized control strategy is designed, which combines a differential-enthalpy based AHU return-air ratio control, a demand-controlled ventilation, and supply-air temperature humidity control via the RTU and DW controls. The proposed control method is evaluated with the Modelica simulation model for a selected set of scenarios

Pan, Chao↗

Evaluating the Adaptability of Reinforcement Learning Based HVAC Control for Residential Houses

Intelligent Heating, Ventilation, and Air Conditioning (HVAC) control using deep reinforcement learning (DRL) has recently gained a lot of attention due to its ability to optimally control the complex behavior of the HVAC system. However, more exploration is needed on understanding the adaptability challenges that the DRL agent could face during the deployment phase. Using online learning for such applications is not realistic due to the long learning period and likely poor comfort control during the learning process. Alternatively, DRL can be pre-trained using a building model prior to deployment. However, developing an accurate building model for every house and deploying a pre-trained DRL model for HVAC control would not be cost-effective. In this study, we focus on evaluating the ability of DRL-based HVAC control to provide cost savings when pre-trained on one building model and deployed on different house models with varying user comforts. We observed around 30% of cost reduction by pre-trained model over baseline when validated in a simulation environment and achieved up to 21% cost reduction when deployed in the real house. This finding provides experimental evidence that the pre-trained DRL has the potential to adapt to different house environments and comfort settings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Reinforcement Learning Based HVAC Control for Reducing Carbon Footprint of Buildings

In this paper, we present our work on deep reinforcement learning (DRL) based intelligent control of Heating, Ventilation, and Air Conditioning (HVAC) with the goal of reducing carbon emission. We performed this task using 1) Marginal Operating Emission Rates (MOER), where the objective was to shift the demand to the low emission period of the day and 2) Time-Of-Use (TOU) demand-response price where the objective was to shift the demand to low price period of the day. This was achieved by learning an optimal pre-cooing strategy. We found the carbon emission reduction in the range of 6%-16% depending on the opportunity presented by the MOER signal. Similarly, we observed the carbon emission reduction in the range of 23%-29% during the peak price period when TOU price was used. The results clearly demonstrated the applicability of our approach in reducing the carbon footprint of the building.

carbon emission↗

Hot, Cold, or Just Right? Using a Wide-View Infrared Biometric Sensor to Improve Occupant Comfort and Reduce Overcooling in Buildings via Closed-loop Control (CRADA Final Report)

This research adds to the understanding of building energy management by fundamentally challenging the long-standing paradigm of controlling an environmental parameter—air temperature—and assuming occupant comfort will follow. The project developed and demonstrated a novel approach that directly senses physiological indicators of human comfort to enable closedloop, human-centric control of heating, ventilation, and air conditioning (HVAC) systems. This work shifts the focus from open-loop environmental control to a closed-loop system that prioritizes the occupants' actual thermal state. The primary benefit to the public is the potential for a simultaneous improvement in the quality of indoor environments, where people spend most of their time, and a significant reduction in national energy consumption. Overcooling, or the overuse of cooling energy in a way that discomforts occupants, wastes approximately 0.5 Quads of primary energy annually in U.S. commercial buildings and creates unproductive indoor environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electricity Pricing aware Deep Reinforcement Learning based Intelligent HVAC Control

Recently, deep reinforcement learning (DRL) based intelligent control of Heating, Ventilation, and Air Conditioning (HVAC) has gained a lot of attention due to DRL's ability to optimally control HVAC for minimizing operational cost while maintaining resident's comfort. The success of such DRL-based techniques largely depends on the articulation of the problem in terms of states, actions, and reward function. Inclusion of the electricity pricing information in the problem formulation can play an important role in saving the cost of HVAC operation. However, less attention has been given in the literature on formulating well-crafted state features based on electricity pricing. In this work, we propose an approach for training the DRL model with a specific focus on feature engineering based on electricity pricing. During training, we generate random but sufficiently realistic electricity price signals so that the pre-trained DRL model is robust and adaptive to the dynamic and variable electricity prices. The validation results are encouraging and show the potential of ≈12%-15% savings in the one day cost of HVAC operation, proving the usefulness of including electricity pricing related features as state features.

Kurte, Kuldeep↗

Consumer Guide to Home Ventilation

Learn about the types of home ventilation and how ventilation can help you avoid moisture problems. This fact sheet from Energy Saver includes information why it's important to ventilate and how you can use ventilation strategies to control moisture in your home for comfort and energy savings.

ventilation, carbon monoxide, moisture, fans, duct↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗