Search NASA⌕ Search

SEARCH · Search NASA

Results for “venting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Molybdenum in basalt-hosted seafloor hydrothermal systems: Experimental, theoretical, and field sampling approaches

Here, seafloor hydrothermal vents represent potential sources of Mo and other biologically relevant transition metals to the global ocean, complementing continental runoff. Here, we use a combination of experimental, theoretical, and field-sampling approaches to investigate the behavior of Mo in basalt-hosted seafloor hydrothermal systems to provide insight into the processes controlling Mo concentrations in hydrothermal fluids and to derive estimates of vent fluid Mo concentrations and fluxes. Results of this study demonstrate that reaction fluids generated from 350°C, 500 bar hydrothermal basalt alteration experiments contain 775–801 nmol/kg Mo and are thus comparable to a recently collected time series of natural seafloor vent fluids that contained 200–220 nmol/kg Mo at 302°C and 29–30 nmol/kg at 281–282°C (Evans et al., 2023). Synchrotron-based analyses of experimentally altered basalt produced in this study and additional natural samples of altered oceanic crust originally collected from Pito Deep Rift reveal the presence of Mo-rich particles consistent with trace molybdenite. Comparisons of Mo:Cu ratios in natural vent fluids and near-vent sediment trap samples from Main Endeavour Field indicate that vent fluid Mo is readily incorporated into buoyant plume particles and advected out of the near-vent field, analogous to previous mass balance studies of Cu in this region. Thermodynamic calculations of molybdenite solubility in the context of mineral-buffered hydrothermal fluids and comparisons with natural and experimental hydrothermal fluids suggest that high-temperature vent fluids contain 30–1500 nmol/kg Mo. While a minor component of the modern Mo budget, hydrothermal Mo fluxes are estimated to have constituted 0.3–200× the contemporaneous continental weathering fluxes prior to the ~2.4 Ga ago “Great Oxidation Event” and widespread oxidative continental weathering. Overall, identification of hydrothermal vents as a source of Mo-rich plume particles with potential for dispersal into the wider marine environment has significant implications for hypotheses regarding the co-evolution of Life and Earth’s environments, specifically the form and availability of Mo in anoxic Archean-Eon oceans, where Mo-dependent enzymatic pathways are thought to have emerged and subsequently evolved.

58 GEOSCIENCES↗

Effects of 18 O Exchange on Neutron Emission Rates of Aging 238 PuO 2 LWRHUs

The Lightweight Radioisotope Heater Unit (LWRHU) provides about 1 Watt of thermal power to critical electrical and mechanical systems in the extreme temperatures of space, maintaining the operating temperature of the spacecraft’s scientific and general operating equipment. Los Alamos National Laboratory (LANL) designed and tested the LWRHU in the 1970s through early 1980s. The first production campaign at LANL was in the early 1980s in support of the Galileo mission in which over 100 LWRHUs were manufactured. In the mid-1990s, almost 200 LWRHUs were manufactured in support of the Cassini mission. After the primary Cassini manufacturing campaign, the Department of Energy (DOE) approved the fabrication of more than 10 additional LWRHUs as spares in 1998. The LWRHU assembly contains the following components: a fuel pellet, a vented capsule, a pyrolytic graphite insulator, and a fine-weave pierced fabric (FWPF) graphite aeroshell. The fuel pellet is a hot-pressed 238 PuO 2 cylindrical pellet that is sintered to create a ceramic pellet. The pellet is encapsulated in a platinum-rhodium encapsulation. The welded fueled clad is placed inside a pyrolytic graphite thermal insulation to protect the fuel from the heat produced in reentry events. The exterior layer of the LWRHU assembly is the FWPF aeroshell. Before sintering, PuO 2 granules are heated in a furnace at temperatures greater than or equal to 700°C under an enriched 16 O atmosphere in order to reduce trace quantities of 18 O. Because 18 O undergoes an (α,n) reaction, 18 O needs to be removed as much as possible to meet radiation emission requirements set by the Jet Propulsion Laboratory (JPL) and the National Aeronautics and Space Administration (NASA), as well as other agencies. The relative abundances of the oxygen isotopes are indicated by neutron emission rate (NER) measurements. LWRHUs are vented with a sintered platinum frit vent (George 1986). During extraterrestrial operation, the vent in the cladding allows helium from the decay of plutonium to escape and relieves pressure from the system while preventing the solids from escaping (Rinehart 1996, Tate 1982 & 1985). This vent is protected during manufacture by a platinum-30 rhodium cover. The capsule vent is activated by milling a 0.025-inch diameter hole through the protective cover to a nominal depth of 0.015 inches, generally immediately before the LWRHU is loaded into the aeroshell (George 1986). Prior to long-term storage, LWRHUs are vented and thus potentially allow infiltration of 18 O from the ambient atmosphere. Although NER decreases with age due to the reduction in emitted alpha particles, it might be expected that NER reduction is mitigated by the exchange of 18 O. However, this is not necessarily the case and no trend was observed relating NER to age other than the natural decay of 238 Pu (Mulford 2021). The most probable and dominant factor for determining specific NER was manufacturing discrepancies between individual units. It is important to understand the lack of observed 16 O- 18 O exchange and to compare LWRHU pellets as much as possible.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Historic Context and Mitigation Documentation for a Portion of the U12n Tunnel Ventilation and Containment Systems, Area 12, Nevada National Security Site, Nye County, Nevada

The National Nuclear Security Administration Nevada Field Office (NNSA/NFO) has proposed repurposing the U12n Vent Hole #2 (SHPO Resource S2488) and the U12n.10 Vent Hole (S2489) for water sampling in the U12n Tunnel. The vent holes are part of the historic ventilation system for the tunnel and are contributing elements to the U12n Tunnel Historic District (D84). In consultation with the SHPO, NNSA/NFO determined the undertaking will have an adverse effect on the vent holes. The NNSA/NFO and the SHPO negotiated a memorandum of (MOA) with stipulations to mitigate adverse effects. This submission is to comply with the stipulations in the executed Memorandum of Agreement Between the National Nuclear Security Administration Nevada Field Office, Environmental Management Nevada Program Office, and the Nevada State Historic Preservation Officer Regarding Repurposing of Portions of the Ventilation System of the U12n Tunnel Complex Located in Area 12 at the Nevada National Security Site. In accordance with the MOA, the manuscript provides a historic context that describes the development and functioning of the historic U12n Tunnel ventilation system for underground nuclear tests (Stipulation III.C). High resolution digital color images of the vent hole containment doors, nearby elements, and overviews were obtained and keyed to a map and a photo index (Stipulation III.A) (Appendix A). Lastly, Architectural Resource Assessment (ARA) forms were completed for each of the vent holes and Historic District D84 (Stipulation III.B) (Appendix B). The documentation including the historic context report, photographs, image files, and resource forms produced to fulfill the terms of the MOA will be archived with the Nuclear Testing Archive in Las Vegas (Stipulation III.D).

54 ENVIRONMENTAL SCIENCES↗

Measurement and analysis of clothes dryer air leakage

Each year clothes dryer appliances are sold globally in the tens of millions. Both vented and ventless types are common and are heated by combustion, electric resistance, or electric heat pumps. In the dyer air path, segments can be defined between components such as the drum, blower, filter, screens or grills, and heat exchangers (where applicable). In this work, a technique was developed to experimentally measure air leakage into and from the segments of a clothes dryer. Detailed leakage measurements were taken on two vented and one ventless residential clothes dryer. The measurements were quantified as a leakage flow coefficient for each segment. For two dryers (one vented and one ventless), these flow coefficients were combined with in situ operating pressure measurements to determine leakage flow rates for each segment. For these two units under normal operation with air pressures within 0.5 kPa (50 mm water column) of ambient pressure, volumetric system air leakage was found to be about 20–60% of the blower airflow. Furthermore, a quasi–steady state psychrometric analysis was conducted on vented dryers with negatively pressurized drums. The analysis revealed that leakage quantity, location, and direction are essential to achieving an acceptable energy balance and accurate modeling results for a vented heat pump clothes dryer but are of limited significance for vented electric resistance clothes dryers.

42 ENGINEERING↗

Pressure Transducer Measurement Variability in Deep Wells Screened Across the Water Table

Abstract Automated water level measurements collected using vented pressure transducers in deep wells screened across the water table may exhibit a greater response to barometric pressure changes than the true water level. The cause was hypothesized to be disequilibrium in barometric pressure between the wellbores and land surface due to air exchange with the deep vadose zone. In this study, vented and nonvented pressure transducers were installed and operated simultaneously in two deep wells screened across the water table. A vent tube open to the atmosphere at land surface allowed for barometric compensation of the vented transducers. Two nonvented transducers were installed in each well, one submerged in the water and one above the water surface. The difference in readings allowed for barometric compensation. Manual measurements were also collected. It was confirmed that measurements from the vented transducers exhibited greater variability in response to barometric pressure changes than the nonvented transducers and manual measurements. Comparison of the downhole barometric pressure measurements to values from a nearby meteorology station showed the response in the wells to changes in barometric pressure was time‐lagged and attenuated. Thus, the reference pressure from land surface supplied to the vented transducers was not representative of the air pressure within the wells. This caused fluctuations of the transducer readings in response to barometric pressure changes to be greater than the true water level change. This issue can be resolved by the use of nonvented pressure transducers.

McDonald, John P.↗