Search NASA⌕ Search

SEARCH · Search NASA

Results for “versatile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Versatile Approach to Stabilize Liquid–Liquid Interfaces using Surfactant Self-Assembly

Stabilizing liquid–liquid interfaces, whether between miscible or immiscible liquids, is crucial for a wide range of applications, including energy storage, microreactors, and biomimetic structures. Here, in this study, a versatile approach for stabilizing the water-oil interface is presented using the morphological transitions that occur during the self-assembly of anionic, cationic, and nonionic surfactants mixed with fatty acid oils. The morphological transitions underlying this approach are characterized and extensively studied through small-angle X-ray scattering (SAXS), rheometry, and microscopy techniques. Dissipative particle dynamics (DPD) as a simulation tool is adopted to investigate these morphological transitions both in the equilibrium ternary system as well as in the dynamic condition of the water-oil interface. Such a versatile strategy holds promise for enhancing applications such as liquid-in-liquid 3D printing. Moreover, it has the potential to revolutionize a wide range of fields where stabilizing liquid–liquid interfaces not only offers unprecedented opportunities for fine-tuning nanostructural morphologies but also imparts interesting practical features to the resulting liquid shapes. These features include perfusion capabilities, self-healing, and porosity, which could have significant implications for various industries.

36 MATERIALS SCIENCE↗

A multiphysics model of the versatile test reactor based on the MOOSE framework

The traditional modeling approach for sodium fast reactor cores relies on separate physics models, where the fuel performance, thermal–hydraulics, and neutronics calculations required to predict the core physics characteristics for nominal conditions are decoupled by relying on user-imposed boundary conditions. Here, this paper aims at evaluating the impact of multiphysics simulations for predicting the core characteristics of the Versatile Test Reactor, which is being designed as a 300-MWt sodium-cooled fast reactor. The purpose of the Versatile Test Reactor is to accelerate the testing of advanced nuclear materials in the United States. The proposed multiphysics model relies on the Griffin reactor physics code, the SAM thermal–hydraulic system code, the BISON fuel performance code, as well as generic Multiphysics Object-Oriented Simulation Environment capabilities implemented in the open-source tensor mechanics module. For k eff calculations, the introduction of a tight coupling between the neutronics, thermo-mechanical and thermal–hydraulics models induces a change of around 543 pcm in the eigenvalue, compared to the traditional standalone neutronics calculation where approximate temperature profiles are used. The multiphysics model is then employed for quantifying the impact of the thermal conductivity uncertainties on some of the key figures of merit, such as the fuel centerline temperature, assembly powers, and keff for nominal core conditions. As anticipated, uncertainties on fuel thermal conductivity mostly impact the fuel centerline temperature, and to a lesser extend the k eff .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ExaCA v2.0: A versatile, scalable, and performance portable cellular automata application for additive manufacturing solidification

The previously established ExaCA software for performance portable alloy grain structure simulation has been updated to better represent the solidification behavior during complex alloy processing conditions, such as those encountered during metal additive manufacturing (AM), and for improved performance and scalability. Here, an extension to the time–temperature history input data format and the core ExaCA algorithm to include an arbitrary number of melting and solidification events yielded improved prediction of texture for various melt pool geometries, expanding the range of AM-relevant conditions that can be accurately simulated. Improved heat transport process simulation coupling, including the creation of large raster datasets from single track time–temperature history data and in-memory coupling with the new, performance portable finite difference code Finch, were also demonstrated in example studies on the effect of multilayer AM microstructure predictions on hatch spacing and cell size, respectively. Additional new features are detailed and demonstrated, including the ability to perform simulations using various interfacial response function forms, execute simulations on state-of-the-art hardware, improved usability through post-processing versatility, and improved strong and weak scaling performance. The performance, physics, and versatility improvements demonstrated here will further enable large-scale studies on AM process–microstructure relationships that were not previously possible. Furthermore, the usability improvements and ability to run coupled AM process–microstructure simulations using the Finch-ExaCA workflow will facilitate broader use of this open-source software by the computational materials community.

36 MATERIALS SCIENCE↗

Performance of the Versatile Array of Neutron Detectors at Low Energy (VANDLE)

The Versatile Array of Neutron Detectors at Low Energy (VANDLE) is a new, highly efficient plastic-scintillator array constructed for decay and transfer reaction experimental setups that require neutron detection. The versatile and modular design allows for customizable experimental setups including beta-delayed neutron spectroscopy and (d,n) transfer reactions in normal and inverse kinematics. The neutron energy and prompt-photon discrimination is determined through the time of flight technique. Fully digital data acquisition electronics and integrated triggering logic enables some VANDLE modules to achieve an intrinsic efficiency over 70% for 300-keV neutrons, measured through two different methods. A custom Geant4 simulation models aspects of the detector array and the experimental setups to determine efficiency and detector response. Lastly, a low detection threshold, due to the trigger logic and digitizing data acquisition, allowed us to measure the light-yield response curve from elastically scattered carbon nuclei inside the scintillating plastic from incident neutrons with kinetic energies below 2 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatility of the adenovirus-vectored foot-and-mouth disease vaccine platform across multiple foot-and-mouth disease virus serotypes and topotypes using a vaccine dose representative of the AdtA24 conditionally licensed vaccine

We investigated the serotype- and topotype versatility of a replication-deficient human adenovirus serotype 5 vectored foot-and-mouth disease (FMD) vaccine platform (AdtFMD). Sixteen AdtFMD recombinant subunit monovalent vaccines targeting twelve distinct FMD virus (FMDV) serotype/topotypes in FMD Regional Pools I-VII were constructed. The AdtA24 serotype conditionally licensed vaccine served as the basis for vaccine design and target dose for cattle clinical trials. Several vaccines contained an additional RGD motif genetic insertion in the adenovector fiber knob, and/or a full-length 2B gene insertion in the FMDV P1 gene cassette. In 13 of the 22 efficacy studies conducted, naïve control and AdtFMD vaccinated cattle were challenged intradermolingually at 2 weeks post-vaccination using a FMDV strain homologous to the AdtFMD vaccine strain. Each of the 16 AdtFMD vaccines were immunogenic based on the presence of homologous neutralizing antibodies in the serum of approximately 90% of total vaccinates (n = 375) on the day of challenge. Importantly, for 75% of vaccines tested, the effective dose that conferred 100% protection against clinical FMD was identical to or in some cases lower than, the minimum protective dose for the conditionally licensed AdtA24 vaccine formulated with ENABL® adjuvant. Results also confirmed the capability of the AdtFMD vaccine platform to differentiate infected from vaccinated animals (DIVA) across the five FMDV serotypes evaluated. Collectively, this comprehensive set of FMD cattle vaccine dose ranging studies highlights the serotype- and topotype versatility of the AdtFMD vaccine platform for further development, licensure, and application in FMD outbreak control and disease eradication efforts.

59 BASIC BIOLOGICAL SCIENCES↗

Solid-State Side-Chain Functionalization of Conjugated Polymers for Expanded Chemical and Functional Versatility

Conjugated polymers that integrate diverse chemical functionalities with high electronic performance are essential for advanced organic electronic, optoelectronic, and biointerfaced technologies. Achieving such multifunctionality typically requires grafting functional units onto polymer side chains. However, conventional solution-phase approaches remain constrained by solubility limitations, side-chain-induced packing disruptions, and challenges in preserving charge transport. Here, we introduce a solid-state side-chain functionalization strategy that exploits a swellable polar side-chain architecture and azide–alkyne click chemistry to enable efficient molecular diffusion and reaction throughout predeposited polymer thin films. This approach substantially broadens the chemical compatibility of graftable units and mitigates the adverse effects on the electrical property. Moreover, the method supports spatially selective functionalization within a continuous film, enabling the patterned incorporation of chemically distinct groups to produce spatially defined optical properties. Here, this solid-state strategy thus provides a versatile platform for constructing conjugated polymers with expanded chemical versatility, preserved electronic performance, and programmable spatial functionality.

Conjugated polymers↗

PlasmidMaker is a versatile, automated, and high throughput end-to-end platform for plasmid construction

Abstract Plasmids are used extensively in basic and applied biology. However, design and construction of plasmids, specifically the ones carrying complex genetic information, remains one of the most time-consuming, labor-intensive, and rate-limiting steps in performing sophisticated biological experiments. Here, we report the development of a versatile, robust, automated end-to-end platform named PlasmidMaker that allows error-free construction of plasmids with virtually any sequences in a high throughput manner. This platform consists of a most versatile DNA assembly method using Pyrococcus furiosus Argonaute ( Pf Ago)-based artificial restriction enzymes, a user-friendly frontend for plasmid design, and a backend that streamlines the workflow and integration with a robotic system. As a proof of concept, we used this platform to generate 101 plasmids from six different species ranging from 5 to 18 kb in size from up to 11 DNA fragments. PlasmidMaker should greatly expand the potential of synthetic biology.

59 BASIC BIOLOGICAL SCIENCES↗

Structural Insights into Catalytic Versatility of the Flavin-dependent Hydroxylase (HpaB) from Escherichia coli

4-Hydroxyphenylacetate 3-hydroxylase (EcHpaB) from Escherichia coli is capable of efficient orthohydroxylation of a wide range of phenolic compounds and demonstrates great potential for broad chemoenzymatic applications. To understand the structural and mechanistic basis of its catalytic versatility, we elucidated the crystal structure of EcHpaB by X-ray crystallography, which revealed a unique loop structure covering the active site. We further performed mutagenesis studies of this loop to probe its role in substrate specificity and catalytic activity. Our results not only showed the loop has great plasticity and strong tolerance towards extensive mutagenesis, but also suggested a flexible loop that enables the entrance and stable binding of substrates into the active site is the key factor to the enzyme catalytic versatility. These findings lay the groundwork for editing the loop sequence and structure for generation of EcHpaB mutants with improved performance for broader laboratory and industrial use.

59 BASIC BIOLOGICAL SCIENCES↗

A versatile strategy for controlled assembly of plasmonic metal/semiconductor hemispherical nano-heterostructure arrays

Recent advances in manipulating plasmonic properties of metal/semiconductor heterostructures have opened up new avenues for basic research and applications. Herein, we present a versatile strategy for the assembly of arrays of plasmonic metal/semiconductor hemispherical nano-heterostructures (MSHNs) with control over spacing and size of the metal/semiconductor heterostructure array, which can facilitate a wide range of scientific studies and applications. The strategy combines nanosphere lithography for generating the metal core array with solution-based chemical methods for the semiconductor shell that are widely available and kinetically controllable. Periodic arrays of Au/Cu 2 O and Ag/Cu 2 O heterostructures are synthesized to demonstrate the approach and highlight the versatility and importance of the tunability of plasmonic properties. The morphology, structure, optical properties, and elemental compositions of the heterostructures were analyzed. Finally, this strategy can be important for understanding and manipulating fundamental nanoscale solid-state physical and chemical properties, as well as assembling heterostructures with desirable structure and functionality for applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Versatile Low Level RF System For Linear Accelerators

The Low Level RF (LLRF) system is the source of all of the rf signals required for an rf linear accelerator. These signals are amplified to drive accelerator and buncher cavities. It can even provide the synchronizing signal for the rf power for a synchrotron. The use of Direct Digital Synthesis (DDS) techniques results in a versatile system that can provide multiple coherent signals at the same or different frequencies with adjustable amplitudes and phase relations. Pulsing the DDS allows rf switching with an essentially infinite on/off ratio. The LLRF system includes a versatile phase detector that allows phase-locking the rf frequency to a cavity at any phase angle over the full 360 deg. range. With the use of stepper motor driven slug tuners multiple cavity resonant frequencies can be phase locked to the rf source frequency. No external phase shifters are required and there is no feedback loop phase setup required. All that is needed is to turn the frequency feedback on. The use of Digital Signal Processing (DSP) allows amplitude and phase control over the entire rf pulse. This paper describes the basic principles of a LLRF system that has been used for both proton accelerators and electron accelerators, including multiple tank accelerators, sub-harmonic and fundamental bunchers, and synchrotrons.

43 PARTICLE ACCELERATORS↗

A Versatile Ion Injector at KACST

A versatile ion-beam injector is presently being constructed at the National Centre for Mathematics and Physics (NCMP) at the King Abdul-Aziz City for Science and Technology (KACST), Saudi Arabia. This versatile injector will provide an electrostatic storage ring with high-quality ion beams of energies up to 30 keV per charge q. It will also allow for crossed-beams experiments in single-pass setups. The injector has been designed to include beams from two different ion sources, switched by a 90 deg. deflection setup, and to allow for matching of the beam parameters to the Twiss parameters of the ring. The injector is equipped with two crossed beam-lines (inlets), with duplicated beam extraction and acceleration systems. As part of the initial setup, a simple electric discharge ion source has been developed for commissioning of the whole injector. In this paper, we report on the ion optics layout and the design parameters of the injector.

43 PARTICLE ACCELERATORS↗

Versatile module for experiments with focussing neutron guides

We report the development of a versatile module that permits fast and reliable use of focussing neutron guides under varying scattering angles. A simple procedure for setting up the module and neutron guides is illustrated by typical intensity patterns to highlight operational aspects as well as typical parasitic artefacts. Combining a high-precision alignment table with separate housings for the neutron guides on kinematic mounts, the change-over between neutron guides with different focussing characteristics requires no readjustments of the experimental setup. Exploiting substantial gain factors, we demonstrate the performance of this versatile neutron scattering module in a study of the effects of uniaxial stress on the domain populations in the transverse spin density wave phase of single crystal Cr.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

VERDI: VERsatile DIffractometer with wide-angle polarization analysis for magnetic structure studies in powders and single crystals

The VERsatile DIffractometer will set a new standard for a world-class magnetic diffractometer with versatility for both powder and single crystal samples and capability for wide-angle polarization analysis. The instrument will utilize a large single-frame bandwidth and will offer high-resolution at low momentum transfers and excellent signal-to-noise ratio. A horizontal elliptical mirror concept with interchangeable guide pieces will provide high flexibility in beam divergence to allow for a high-resolution powder mode, a high-intensity single crystal mode, and a polarized beam option. A major science focus will be quantum materials that exhibit emergent properties arising from collective effects in condensed matter. The unique use of polarized neutrons to isolate the magnetic signature will provide optimal experimental input to state-of-the-art modeling approaches to access detailed insight into local magnetic ordering.

36 MATERIALS SCIENCE↗

Highly efficient, versatile, self-Q-switched, high-repetition-rate microchip laser generating Ince–Gaussian modes for optical trapping

Lasers operating in the Ince-Gaussian (IG) mode have potential applications for optical manipulation of microparticles and formation of optical vortices, as well as for optical trapping and optical tweezers. Versatile, self-Q-switched, high-peak-power, high-repetition-rate Cr, Nd:YAG microchip lasers operating in the IG mode are implemented under tilted, tightly focused laser-diode pumping. An average output power of over 2 W is obtained at an absorbed pump power of 6.4 W. The highest optical-to-optical efficiency of 33.2% is achieved at an absorbed pump power of 3.9 W. Laser pulses with a pulse energy of 7.5 μJ, pulse width of 3.5 ns and peak power of over 2 kW are obtained. A repetition rate up to 335 kHz is reached at an absorbed pump power of 5.8 W. Highly efficient, versatile, IG-mode lasers with a high repetition rate and a high peak power ensure a better flexibility in particle manipulation and optical trapping. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Versatile technique for assessing thickness of 2D layered materials by XPS

X-ray photoelectron spectroscopy (XPS) has been utilized as a versatile method for thickness characterization of various two-dimensional (2D) films. Accurate thickness can be measured simultaneously while acquiring XPS data for chemical characterization of 2D films having thickness up to approximately 10 nm. For validating the developed technique, thicknesses of few-layer graphene (FLG), MoS 2 and amorphous boron nitride (a-BN) layer, produced by microwave plasma chemical vapor deposition (MPCVD), plasma enhanced chemical vapor deposition (PECVD), and pulsed laser deposition (PLD) respectively, were accurately measured. The intensity ratio between photoemission peaks recorded for the films (C 1s, Mo 3d, B 1s) and the substrates (Cu 2p, Al 2p, Si 2p) is the primary input parameter for thickness calculation, in addition to the atomic densities of the substrate and the film, and the corresponding electron attenuation length (EAL). The XPS data was used with a proposed model for thickness calculations, which was verified by cross-sectional transmission electron microscope (TEM) measurement of thickness for all the films. The XPS method determines thickness values averaged over an analysis area which is orders of magnitude larger than the typical area in cross-sectional TEM imaging, hence provides an advanced approach for thickness measurement over large areas of 2D materials. The study confirms that the versatile XPS method allows rapid and reliable assessment of the 2D material thickness and this method can facilitate in tailoring growth conditions for producing very thin 2D materials effectively over a large area. Furthermore, the XPS measurement for a typical 2D material is non-destructive and does not require special sample preparation. Furthermore, after XPS analysis, exactly the same sample can undergo further processing or utilization.

2D film thickness↗

Versatile recognition of graphene layers from optical images under controlled illumination through green channel correlation method

In this study, a simple yet versatile method is proposed for identifying the number of exfoliated graphene layers transferred on an oxide substrate from optical images, utilizing a limited number of input images for training, paired with a more traditional number of a few thousand well-published Github images for testing and predicting. Two thresholding approaches, namely the standard deviation-based approach and the linear regression-based approach, were employed in this study. The method specifically leverages the red, green, and blue color channels of image pixels and creates a correlation between the green channel of the background and the green channel of the various layers of graphene. This method proves to be a feasible alternative to deep learning-based graphene recognition and traditional microscopic analysis. The proposed methodology performs well under conditions where the effect of surrounding light on the graphene-on-oxide sample is minimum and allows rapid identification of the various graphene layers. Here, the study additionally addresses the functionality of the proposed methodology with nonhomogeneous lighting conditions, showcasing successful prediction of graphene layers from images that are lower in quality compared to typically published in literature. In all, the proposed methodology opens up the possibility for the non-destructive identification of graphene layers from optical images by utilizing a new and versatile method that is quick, inexpensive, and works well with fewer images that are not necessarily of high quality.

36 MATERIALS SCIENCE↗

The AUREX cell: a versatile operando electrochemical cell for studying catalytic materials using X-ray diffraction, total scattering and X-ray absorption spectroscopy under working conditions

Understanding the structure–property relationship in electrocatalysts under working conditions is crucial for the rational design of novel and improved catalytic materials. This paper presents the Aarhus University reactor for electrochemical studies using X-rays (AUREX) operando electrocatalytic flow cell, designed as an easy-to-use versatile setup with a minimal background contribution and a uniform flow field to limit concentration polarization and handle gas formation. The cell has been employed to measure operando total scattering, diffraction and absorption spectroscopy as well as simultaneous combinations thereof on a commercial silver electrocatalyst for proof of concept. This combination of operando techniques allows for monitoring of the short-, medium- and long-range structure under working conditions, including an applied potential, liquid electrolyte and local reaction environment. The structural transformations of the Ag electrocatalyst are monitored with non-negative matrix factorization, linear combination analysis, the Pearson correlation coefficient matrix, and refinements in both real and reciprocal space. Upon application of an oxidative potential in an Ar-saturated aqueous 0.1 M KHCO 3 /K 2 CO 3 electrolyte, the face-centered cubic (f.c.c.) Ag gradually transforms first to a trigonal Ag 2 CO 3 phase, followed by the formation of a monoclinic Ag 2 CO 3 phase. A reducing potential immediately reverts the structure to the Ag (f.c.c.) phase. Following the electrochemical-reaction-induced phase transitions is of fundamental interest and necessary for understanding and improving the stability of electrocatalysts, and the operando cell proves a versatile setup for probing this. In addition, it is demonstrated that, when studying electrochemical reactions, a high energy or short exposure time is needed to circumvent beam-induced effects.

Frank, Sara (ORCID:0000000163218363)↗

A versatile scalable PET processing system

Positron Emission Tomography (PET) historically has major clinical and preclinical applications in cancerous oncology, neurology, and cardiovascular diseases. Recently, in a new direction, an application specific PET system is being developed at Thomas Jefferson National Accelerator Facility (Jefferson Lab) in collaboration with Duke University, University of Maryland at Baltimore (UMAB), and West Virginia University (WVU) targeted for plant eco-physiology research. The new plant imaging PET system is versatile and scalable such that it could adapt to several plant imaging needs - imaging many important plant organs including leaves, roots, and stems. The mechanical arrangement of the detectors is designed to accommodate the unpredictable and random distribution in space of the plant organs without requiring the plant be disturbed. Prototyping such a system requires a new data acquisition system (DAQ) and data processing system which are adaptable to the requirements of these unique and versatile detectors.

43 PARTICLE ACCELERATORS↗