Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Addressing Limitations of the Endpoint Slippage Analysis

Some rate of oxidation and reduction side-reactions will inevitably coexist in most rechargeable batteries. While parasitic reduction traps electrons, parasitic oxidation donates electrons to the cell’s inventory and may cause temporary capacity gain. Consequently, capacity measurements can provide unreliable information about the total extent of side-reactions occurring in the cell. The most widely used method to determine the rate of both these parasitic processes involves analyzing the slippage of endpoints, which consists in tracking the termination of cell charge and discharge when data is represented along a cumulative capacity axis. Here, we argue that this approach could lead to inaccuracies when applied to certain systems, which includes Si electrodes in Li-ion batteries and hard carbon in Na-ion batteries. This inaccuracy originates from the smooth nature of the voltage profiles of these materials at low and high alkali-ion content, causing the termination of charge and discharge to be dictated by voltage changes at both the positive and negative electrodes. We analyze this issue in quantitative terms and propose equations that can provide true rates of parasitic processes from experimental endpoint slippage data. This work shows that, in battery science, well-established analytical approaches may not be directly transferrable to new electrode systems.

25 ENERGY STORAGE↗

Thermodynamic Modeling of a Solid Oxide Fuel Cell to Couple with an Existing Gas Turbine Engine Model

The Controls and Dynamics Technology Branch at NASA Glenn Research Center are interested in combining a solid oxide fuel cell (SOFC) to operate in conjunction with a gas turbine engine. A detailed engine model currently exists in the Matlab/Simulink environment. The idea is to incorporate a SOFC model within the turbine engine simulation and observe the hybrid system's performance. The fuel cell will be heated to its appropriate operating condition by the engine s combustor. Once the fuel cell is operating at its steady-state temperature, the gas burner will back down slowly until the engine is fully operating on the hot gases exhausted from the SOFC. The SOFC code is based on a steady-state model developed by The U.S. Department of Energy (DOE). In its current form, the DOE SOFC model exists in Microsoft Excel and uses Visual Basics to create an I-V (current-voltage) profile. For the project's application, the main issue with this model is that the gas path flow and fuel flow temperatures are used as input parameters instead of outputs. The objective is to create a SOFC model based on the DOE model that inputs the fuel cells flow rates and outputs temperature of the flow streams; therefore, creating a temperature profile as a function of fuel flow rate. This will be done by applying the First Law of Thermodynamics for a flow system to the fuel cell. Validation of this model will be done in two procedures. First, for a given flow rate the exit stream temperature will be calculated and compared to DOE SOFC temperature as a point comparison. Next, an I-V curve and temperature curve will be generated where the I-V curve will be compared with the DOE SOFC I-V curve. Matching I-V curves will suggest validation of the temperature curve because voltage is a function of temperature. Once the temperature profile is created and validated, the model will then be placed into the turbine engine simulation for system analysis.

Brinson, Thomas E.↗

Manipulating Na/TM Ratio‐Driven Structural Heterogeneity of O3‐NaNi 1/3 Fe 1/3 Mn 1/3 O 2 Cathode for High‐Voltage Sodium‐Ion Batteries

The stability of O3-type NaNi 1/3 Fe 1/3 Mn 1/3 O 2 under high-voltage cycling is dictated by how synthesis encodes lattice strain and redox heterogeneity. Here, in this study, the role of Na:TM stoichiometry is systematically resolved by tuning the NaOH:precursor ratio during solid-state synthesis. The stoichiometric condition (Na:TM = 1.00) yields minimized microstrain, enabling uniform O3–P3 phase evolution and homogeneous multi-metal redox with preserved octahedral symmetry. In contrast, Na-excess compositions inherit disordered intermediates and heterogeneous distortion fields that trigger abrupt multiphase transitions and promote localized charge redistribution. In situ XRD captures the divergence in phase-transition pathways, TXM resolves particle-level redox heterogeneity, and XANES corroborates a stronger and more reversible Fe redox contribution at stoichiometry, shifting to diminished Fe participation and spatially inhomogeneous redox at higher Na content. These results establish Na:TM stoichiometry as a critical synthesis parameter controlling both structural coherence and redox stability. Electrochemically, the stoichiometric composition exhibits smooth voltage profiles with minimal polarization growth and retains nearly 80% of its initial capacity after 100 cycles even at an extended 4.2 V cutoff, whereas Na-excess compositions show significantly reduced initial coulombic efficiency and rapid voltage fade. Precise stoichiometric tuning provides a scalable route to defect-suppressed O3 frameworks, enabling structurally resilient, high-voltage sodium-layered cathodes.

36 MATERIALS SCIENCE↗

ADMS Test Bed Updates

This webinar will present results from a joint project with utility partner Xcel Energy in which we evaluated their ADMS application for volt-var optimization using different levels of model quality. We were able to help Xcel Energy understand the trade-offs of telemetry measurements and model quality when managing a feeder's voltage profile to maximize energy conservation. We simulated scenarios with varying levels of model quality and measurement density to evaluate Xcel's options for best using its ADMS. The results help Xcel and other utilities understand how network data affects voltage management as grid operations see continued growth in solar photovoltaic (PV) systems and electric vehicles (EVs).

ADMS↗

Predictive Coordinated and Cooperative Voltage Control for Systems With High Penetration of PV

In this paper, we propose a predictive coordinated and cooperative voltage control method in a power distribution system with high penetration of photovoltaic (PV) units. First, an integrated coordinated voltage control of voltage regulators (VRs) tap positions and cooperative distributed control of the reactive power output from PV inverters are used to maintain system voltages within an appropriate bandwidth. Next, solar power forecasting is applied to predict voltage changes, which are used to set the VR tap positions and capacitor switch status to prevent large voltage fluctuations. The fine tuning of voltage adjustment is then achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on a modified IEEE 123-node test feeder with high penetration of PVs using real measurement data and compared with the base case. Simulation results demonstrate the effectiveness of the integrated voltage control, as well as the enhancement from the predictive control through solar power forecasting-enabled voltage change estimates. Comparison to previous work in the literature shows significant improvement in terms of voltage deviation and reduction in excessive tap changes.

14 SOLAR ENERGY↗

Probabilistic impact of electricity tariffs on distribution grids considering adoption of solar and storage technologies

This study models the role of electricity tariffs on the long-term adoption of photovoltaic and storage technologies as well as the consequent impact on the distribution grid. An adoption model that captures the economic rationality of tariff-driven investments and considers the stochastic nature of individual consumers’ decisions is proposed. This model is then combined with a probabilistic load flow to evaluate the long-term impacts of the adoption on the voltage profiles of the distribution grid. To illustrate the methodology, different components of the electricity tariffs, including solar compensation mechanisms and time differentiation of Time-of-Use (ToU) rates, are evaluated, using a case study involving a section of a medium-voltage network with 118 nodes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Atom-Precise Approach to Damp First-Order Phase Transitions and Its Implications for Neuromorphic Signal Processing

Neuromorphic computing inspired by mammalian intelligence aims to emulate the nonlinear dynamics of biological neurons and synapses to achieve fast, low-energy, and highly efficient information processing. Brain-inspired computing relies on the design and discovery of materials exhibiting nonlinear current–voltage profiles, frequently underpinned by electronic state transitions, to achieve spiking neurons and dynamically tunable synapses. A signature challenge in the design of artificial neurons is controlling the steepness of first-order transitions in active elements, as abrupt transitions are at risk of driving unstable voltage and temperature oscillations, which result in catastrophic device failure. A critical knowledge gap is the lack of structure–function correlations mapping the composition and atomistic structure of crystalline solids to nonlinear dynamical response characteristics. Here, we address the key question of how modification of atomistic structure correlates with alteration of neuron-like functionality. Constructing oscillator circuits from millimeter-scale single crystals enables high-resolution atomic structure solutions, which we use to demonstrate that the selective positioning of Pb cations modifies charge ordering along a one-dimensional CuxV2O5 framework even at low insertion stoichiometries, thereby providing an atom-precise design parameter for damping first-order transitions. We use temperature-variant X-ray diffraction and X-ray spectroscopy to elucidate the suppression of Cu-ion shuttling based on the precise positioning of Pb ions in seven-coordinated tunnel interstitial sites as the mechanistic basis for transition broadening, thus bridging a critical gap between statistical mechanics and quantum chemical descriptions of phase transitions. Such mechanistic understanding thus paves the way to site-selective modification strategies for modulating the sharpness of first-order transitions, with an exemplary demonstration here in tuning neuronal signal processing.

Crystal structure↗

Distributed Data-Driven Optimization for Voltage Regulation in Distribution Systems

Here, this paper proposes a distributed data-driven optimization framework for voltage regulation in distribution systems. The recursive kernel regression and alternating direction method of multipliers (ADMM) are selected to cover the system learning and distributed optimization tasks. The proposed distributed data-driven framework is capable of having a rapid response to system or load changes while considering the operation optimality. Besides, the distributed algorithm parallels the computation tasks and reduces the computational expense of a single agent. To validate the performance of the proposed method, a hypothetical 7-Bus system and the IEEE 123-Bus system are selected to show the effectiveness of the proposed data-driven framework. According to the numerical study results, the proposed method offers great flexibility for selecting customized kernel models for different regions and can effectively improve the system voltage profile in a distributed manner.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Model-Free Voltage Control Approach to Mitigate Motor Stalling and FIDVR for Smart Grids

Electric power networks are large and highly nonlinear dynamical systems that present unique challenges to control design. Though there is a large number of dynamic models for power system stability and control, many models are only useful with right assumptions and wrong for other tasks. Moreover, the dynamic behavior of the grid is increasingly complex under the banner of smart grids. These lead to the difficulty of developing appropriate dynamic modeling, and thus an efficient control strategy. To avoid such modeling challenges, here we present a novel dynamic voltage control strategy based on a model-free control (MFC) approach, requiring no modeling procedure. In particular, it focuses on fault-induced delayed voltage recovery (FIDVR) events, which require complex and accurate dynamic load models to replicate such events. This work utilizes MFC as an online controller to achieve the desired voltage stability under the FIDVR event. The proposed MFC strategy allows simple implementation and low computational cost for efficient mitigation of FIDVR. For benchmarking, a reasonably accurate dynamic performance model is explored. Simulation results with the IEEE 57 bus test network demonstrate the enhanced dynamic voltage profile for load buses having induction motors with the support of reactive power resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiagent-Based Dynamic Voltage Support of Power Converters During Fault Ride-Through

Reference point of applicability (RPA) is a predefined point in a distribution network that performance requirements shall apply. As RPA is not directly controlled by a dedicated distributed energy resource (DER), it requires an aggregate response of multiple DERs over a complex meshed network. Here, this article presents a multiagent-based distributed dynamic voltage support (DDVS) method for coordinated aggregate response of multiple DER units to support RPA voltage profile during and after fault ride-through. DDVS implements a multiagent-based leader target tracking scheme with velocity matching and flock centering features to avoid uncoordinated current injections of cooperative DERs. The DDVS is an event-based approach based on RPA requirements. Two-dimensional voltage support objective is handled: 1) coordinated positive sequence current injection for voltage magnitude boosting and 2) coordinated negative sequence current injection for unbalance voltage mitigation. The results demonstrate that the proposed DDVS algorithm addresses emerging coordinated DVS requirement of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimized Dispatch of Distributed Energy Resources for Resiliency and Power Quality Improvements at the Grid-Edge

Distributed Energy Resources (DERs) installed on low-voltage distribution systems, both utility-owned and nonutility owned may be employed to make improvements to system resiliency and power quality, in addition to simply serving load demand. By selectively dispatching active and reactive power from these existing DERs, improvements in voltage profiles and service availability during adverse events may be achieved. Further benefits can be gained by optimally choosing which DERs to dispatch power from, and the distribution of power from those DERs. For a given operating condition, using Linear Programming methods, optimal power dispatch values for individual DERs can be determined, while considering variables such as voltage gains, losses in the lines and the DERs, and DER reserve capacities. One such optimization technique is developed in this paper, and results from a real-time simulation study on a modified IEEE 13-bus distribution system with three DERs, are being presented. The operation of the optimized DER selection and dispatch algorithm is shown during normal operation of the transmission system when the DERs operate in grid-connected mode. Similar analyses can drive decision making during transmission system failure when the DERs operate in grid-forming or islanded mode.

Chowdhury, Prithwiraj Roy↗

Area scaling investigations of charging phenomena

The charging and discharging behavior of square, planar samples of silvered, fluorinated ethylene-propylene (FEP) Teflon thermal control tape was measured. The equilibrium voltage profiles scaled with the width of the sample. A wide range of discharge pulse characteristics was observed, and the area dependences of the peak current, charge, and pulse widths are described. The observed scaling of the peak currents with area was weaker than that previously reported. The discharge parameters were observed to depend strongly on the grounding impedance and the beam voltage. Preliminary results suggest that measuring only the return-current-pulse characteristics is not adequate to describe the spacecraft discharging behavior of this material. The seams between strips of tape appear to play a fundamental role in determining the discharging behavior. An approximate propagation velocity for the charge cleanoff was extracted from the data. The samples - 232, 1265, and 5058 square centimeters in area - were exposed at ambient temperature to a 1- to 2-nA/sq cm electron beam at energies of 10, 15, and 20 kilovolts in a 19-meter-long by 4.6-meter-diameter simulation facility at the Lewis Research Center.

Aron, P. R.↗

Degradation in Ni-Rich LiNi 1– x – y Mn x Co y O 2 /Graphite Batteries: Impact of Charge Voltage and Ni Content

Ni-rich LiNi 1– x–y Mn x CoyO 2 (NMC) materials are attractive as cathodes for Li-ion batteries due to their high energy density and low Co content. However, these materials may display poor electrochemical reversibility relating to structural and interfacial instabilities. The influence of Ni content and level of delithiation during charge on degradation mechanisms and relevance to electrochemical cycling behavior are probed for LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) and LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) cathode materials in a full cell configuration under two upper voltage limits (4.1 and 4.3 V). The combined use of dQ/dV analysis of electrochemical voltage profiles, operando XRD, and postcycling scanning electron microscopy (SEM) measurements indicates that a major contributor to capacity fade is the large anisotropic volume change from an H2 $\leftrightarrows$ H3 phase transition and associated mechanical degradation particularly for NMC811. Notably, transition metal dissolution and deposition on the negative electrode are found to correlate with the structural changes occurring in the cathode under high voltage charge. X-ray photoelectron spectroscopy (XPS) analyses of the cycled cathodes reveal a more organic-rich cathode–electrolyte interphase (CEI) when cycling to 4.3 V with lower relative amounts of LiF. Surface reconstruction is not a significant factor under these cycling conditions as determined by soft X-ray absorption spectroscopy (sXAS) analysis. The results emphasize the opportunity to match the electrochemical test parameters with the specific NMC active material to mitigate degradation and extend cycle life.

36 MATERIALS SCIENCE↗

Structural Stabilization of P2-type Sodium Iron Manganese Oxides by Electrochemically Inactive Mg Substitution: Insights of Redox Behavior and Voltage Decay

Layered P2-type Na 0.8 Mn 0.5 Fe 0.5 O 2 cathode material is a promising candidate for next-generation sodium-ion batteries due to the economical and environmentally benign characteristics of Mn and Fe. The poor cycling stability of the material, however, is still a problem that must be solved. To address the problem, here, electrochemically inactive Mg 2+ was introduced into the structure by substituting some of the Fe ions. It was shown that Mg substitution led to a smoother voltage profile with improved cycling performance and rate capability. These observations were attributed to the suppressed structural changes during electrochemical processes. Detailed redox mechanisms, associated local structural changes, and phase transitions were investigated by X-ray absorption spectroscopy and X-ray diffraction. From the detailed analysis of electrochemical behaviors, it was also identified how the redox reactions and structural disordering occurred in the high-and low-voltage regions and how Mg substitution stabilized the structure.

25 ENERGY STORAGE↗

Biomimetic composite architecture achieves ultrahigh rate capability and cycling life of sodium ion battery cathodes

Sodium ion batteries are an emerging candidate to replace lithium ion batteries in large-scale electrical energy storage systems due to the abundance and widespread distribution of sodium. Despite the growing interest, the development of high-performance sodium cathode materials remains a challenge. In particular, polyanionic compounds are considered as a strong cathode candidate owing to their better cycling stability, a flatter voltage profile, and stronger thermal stability compared to other cathode materials. Here, we report the rational design of a biomimetic bone-inspired polyanionic Na3V2(PO4)3-reduced graphene oxide composite (BI-NVP) cathode that achieves ultrahigh rate charging and ultralong cycling life in a sodium ion battery. At a charging rate of 1 C, BI-NVP delivers 97% of its theoretical capacity and is able to retain a voltage plateau even at the ultra-high rate of 200 C. It also shows long cycling life with capacity retention of 91% after 10 000 cycles at 50 C. The sodium ion battery cells with a BI-NVP cathode and Na metal anode were able to deliver a maximum specific energy of 350 W h kg−1 and maximum specific power of 154 kW kg−1. In situ and postmortem analyses of cycled BI-NVP (including by Raman and XRD spectra) HRTEM, and STEM-EELS, indicate highly reversible dilation–contraction, negligible electrode pulverization, and a stable NVP-reduced graphene oxide layer interface. The results presented here provide a rational and biomimetic material design for the electrode architecture for ultrahigh power and ultralong cyclability of the sodium ion battery full cells when paired with a sodium metal anode.

25 ENERGY STORAGE↗

Multi-agent voltage control in distribution systems using GAN-DRL-based approach

Active distribution grids can experience voltage fluctuations and violations due to the high penetration of variable distributed energy resources (DERs). These problems might occur because of the uncertain and variable generation natures of these resources, especially solar photovoltaic resources, during panel shadowing scenarios. Volt-VAR control (VVC) is an efficient method that controls the reactive power set-points of the inverters to regulate the voltage of distribution grids. Although several VVC approaches have been proposed recently, the performance of these approaches degrades significantly if behind-the-meter solar generation data are unobservable/missing. Therefore, it is necessary to impute missing/unobservable PV data accurately to be utilized in VVC approaches. Further, this paper proposes a model-free, data-driven, centrally trained, and decentrally executed multi-agent deep reinforcement learning-based VVC architecture to regulate the voltage of distribution networks. A generative adversarial network (GAN) is incorporated to impute the unobservable PV data accurately, which improves the performance of the proposed control architecture. The proposed multi-agent-soft-actor–critic algorithm (MASAC)-based VVC technique utilizes the actual PV dataset as well as the imputed dataset from the GAN framework to learn the optimal coordinated control policy for controlling the optimal reactive power set-points of PV inverters. The effectiveness of the proposed approach is analyzed on a modified IEEE 34-bus test case with added PV inverters. The results are compared and analyzed with a base case model with no VVC and VVC with a local droop control approach, genetic algorithm optimization, and a centralized soft actor–critic-based approach. Moreover, the performance of the proposed approach is compared with that of a multi-agent VVC framework without using the PV generation data and load information as the system state. The results illustrate that the proposed method with more state input improves the voltage profile and reduces the power loss of the network across various loading and PV generation scenarios.

14 SOLAR ENERGY↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comparison of DER Voltage Regulation Technologies Using Real-Time Simulations

Grid operators are now considering using distributed energy resources (DERs) to provide distribution voltage regulation rather than installing costly voltage regulation hardware. DER devices include multiple adjustable reactive power control functions, so grid operators have the difficult decision of selecting the best operating mode and settings for the DER. In this work, we develop a novel state estimation-based particle swarm optimization (PSO) for distribution voltage regulation using DER-reactive power setpoints and establish a methodology to validate and compare it against alternative DER control technologies (volt–VAR (VV), extremum seeking control (ESC)) in increasingly higher fidelity environments. Distribution system real-time simulations with virtualized and power hardware-in-the-loop (PHIL)-interfaced DER equipment were run to evaluate the implementations and select the best voltage regulation technique. Each method improved the distribution system voltage profile; VV did not reach the global optimum but the PSO and ESC methods optimized the reactive power contributions of multiple DER devices to approach the optimal solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗