Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Lunar Science Conference, 4th, Houston, Tex., March 5-8, 1973, Proceedings. Volume 1 - Mineralogy and petrology. Volume 2 - Chemical and isotope analyses. Organic chemistry. Volume 3 - Physical properties

The mineralogy, petrology, chemistry, isotopic composition, and physical properties of lunar materials are described in papers detailing methods, results, and implications of research on samples returned from eight lunar landing sites: Apollo 11, 12, 14, 15, 16, 17, and Luna 16 and 20. The results of experiments conducted or set up on the lunar surface by the astronauts are also described along with observations taken from Command Modules and subsatellites. Major topics include general geology, soil and breccia studies, petrologic studies, mineralogic analyses, elemental compositions, radiometric age determinations, rare gas chemistry, radionuclides, organogenic compounds, particle track records, thermal properties, seismic studies, resonance studies, orbital mapping, lunar atmosphere, magnetic studies, electrical studies, optical properties, and microcratering. Individual items are announced in this issue.

Gose, W. A.↗

Lunar Science Conference, 5th, Houston, Tex., March 18-22, 1974, Proceedings. Volume 1 - Mineralogy and petrology. Volume 2 Chemical and isotope analyses. Organic chemistry. Volume 3 - Physical properties

Numerous studies on the properties of the moon based on Apollo findings and samples are presented. Topics treated include ages of the lunar nearside light plains and maria, orange material in the Sulpicius Gallus formation at the southwestern edge of Mare Serenitatis, impact-induced fractionation in the lunar highlands, igneous rocks from Apollo 16 rake samples, experimental liquid line of descent and liquid immiscibility for basalt 70017, ion microprobe mass analysis of plagioclase from 'non-mare' lunar samples, grain size and the evolution of lunar soils, chemical composition of rocks and soils at Taurus-Littrow, the geochemical evolution of the moon, U-Th-Pb systematics of some Apollo 17 lunar samples and implications for a lunar basin excavation chronology, volatile-element systematics and green glass in Apollo 15 lunar soils, solar wind nitrogen and indigenous nitrogen in Apollo 17 lunar samples, lunar trapped xenon, solar flare and lunar surface process characterization at the Apollo 17 site, and the permanent and induced magnetic dipole moment of the moon. Individual items are announced in this issue.

Gose, W. A.↗

Lunar Science Conference, 7th, Houston, Tex., March 15-19, 1976, Proceedings. Volume 1 - Regolith studies. Volume 2 - Petrogenetic studies of mare and highland rocks. Volume 3 - The moon and other bodies

Attention is given to lunar core studies (multi-core, deep drill, and drive tube), surface soil studies (petrography and geochemistry, light and volatile element studies, and agglutinate related studies), and surfaces process studies. Also considered are mare basalts, with emphasis on mineralogy and petrology, chemical and isotopic studies, and constraints and models of basalt evolution, along with breccia and highland samples with attention given to geochronology, boulders and consortium studies and the formation of highland samples. Remote sensing and photogeology of the moon, crustal bombardment, physical properties of the moon, and comparative planetology are also discussed.

Merrill, R. B.↗

Lunar Science Conference, 8th, Houston, Tex., March 14-18, 1977, Proceedings. Volume 1 - The moon and the inner solar system. Volume 2 - Petrogenetic studies of mare and highland rocks. Volume 3 - Planetary and lunar surfaces

Solar system processes are considered along with the origin and evolution of the moon, planetary geophysics, lunar basins and crustal layering, lunar magnetism, the lunar surface as a planetary probe, remote observations of lunar and planetary surfaces, earth-based measurements, integrated studies, physical properties of lunar materials, and asteroids, meteorites, and the early solar system. Attention is also given to studies of mare basalts, the kinetics of basalt crystallization, topical studies of mare basalts, highland rocks, experimental studies of highland rocks, geochemical studies of highland rocks, studies of materials of KREEP composition, a consortium study of lunar breccia 73215, topical studies on highland rocks, Venus, and regional studies of the moon. Studies of surface processes, are reported, taking into account cratering mechanics and fresh crater morphology, crater statistics and surface dating, effects of exposure and gardening, and the chemistry of surfaces.

Merril, R. B.↗

Storage management in Ada. Three reports. Volume 1: Storage management in Ada as a risk to the development of reliable software. Volume 2: Relevant aspects of language. Volume 3: Requirements of the language versus manifestations of current implementations

The risk to the development of program reliability is derived from the use of a new language and from the potential use of new storage management techniques. With Ada and associated support software, there is a lack of established guidelines and procedures, drawn from experience and common usage, which assume reliable behavior. The risk is identified and clarified. In order to provide a framework for future consideration of dynamic storage management on Ada, a description of the relevant aspects of the language is presented in two sections: Program data sources, and declaration and allocation in Ada. Storage-management characteristics of the Ada language and storage-management characteristics of Ada implementations are differentiated. Terms that are used are defined in a narrow and precise sense. The storage-management implications of the Ada language are described. The storage-management options available to the Ada implementor and the implications of the implementor's choice for the Ada programmer are also described.

Auty, David↗

Data Management Systems (DMS): Complex data types study. Volume 1: Appendices A-B. Volume 2: Appendices C1-C5. Volume 3: Appendices D1-D3 and E

Two categories were chosen for study: the issue of using a preprocessor on Ada code of Application Programs which would interface with the Run-Time Object Data Base Standard Services (RODB STSV), the intent was to catch and correct any mis-registration errors of the program coder between the user declared Objects, their types, their addresses, and the corresponding RODB definitions; and RODB STSV Performance Issues and Identification of Problems with the planned methods for accessing Primitive Object Attributes, this included the study of an alternate storage scheme to the 'store objects by attribute' scheme in the current design of the RODB. The study resulted in essentially three separate documents, an interpretation of the system requirements, an assessment of the preliminary design, and a detailing of the components of a detailed design.

Leibfried, T. F., Jr.↗

Changes in Excision Cavity Volume: Prediction of the Reduction in Absolute Volume During Breast Irradiation

Purpose: The aim of this study was to determine the changes in the excision cavity volume due to the resolution of the surgical effects during the whole breast treatment. Materials and Methods: Seventy-seven patients with early-stage (T1-2 N0) breast cancer treated with breast-conserving therapy were included for this study. All patients underwent a standard planning computed tomography (CT) scan before irradiation treatment. A second CT scan was performed in the week before the start of the boost. Excision cavity volumes were delineated based on the surgical clips and the (surrounding) seroma or hematoma or other surgical changes on both scans by an experienced physician. This resulted in the gross tumor volumes GTV1 and GTV2. Results: The delineated volumes of the GTVs were on average 78.7 cm{sup 3} (range, 1.1-236.0 cm{sup 3}) and 29.7 cm{sup 3} (range, 1.3-123.6 cm{sup 3}) for, respectively, GTV1 and GTV2. The time between the CT scans was on average 37 days (range, 29-74 days). This resulted in a reduction of on average 62%. The absolute reduction per day of the GTV1 was -1.3 cm{sup 3}/day (range, 0.3 to -5.4 cm{sup 3}/day). A linear correlation (correlation coefficient r{sup 2} = 0.81) was observed between the absolute volume of GTV1 and the absolute reduction per day. Conclusion: A significant reduction in excision cavity volume during whole breast irradiation was shown. The observed correlation might be helpful in the decision to perform a second CT scan to adapt the treatment plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging- Versus Computed Tomography-Based Target Volume Delineation of the Glandular Breast Tissue (Clinical Target Volume Breast) in Breast-Conserving Therapy: An Exploratory Study

Purpose: To examine MRI and CT for glandular breast tissue (GBT) volume delineation and to assess interobserver variability. Methods and Materials: Fifteen breast cancer patients underwent a planning CT and MRI, consecutively, in the treatment position. Four observers (two radiation oncologists and two radiologists) delineated the GBT according to the CT and separately to the MR images. Volumes, centers of mass, maximum extensions with standard deviations (SD), and interobserver variability were quantified. Observers viewed delineation differences between MRI and CT and delineation differences among observers. Results: In cranio-lateral and cranio-medial directions, GBT volumes were delineated larger using MRI when compared with those delineated with CT. Center of mass on MRI shifted a mean (SD) 17% (4%) into the cranial direction and a mean 3% (4%) into the dorsal direction when compared with that on the planning CT. Only small variations between observers were noted. The GBT volumes were approximately 4% larger on MRI (mean [SD] ratio MRI to CT GBT volumes, 1.04 [0.06]). Findings were concordant with viewed MRI and CT images and contours. Conformity indices were only slightly different; mean conformity index was 77% (3%) for MRI and 79% (4%) for CT. Delineation differences arising from personal preferences remained recognizable irrespective of the imaging modality used. Conclusions: Contoured GBT extends substantially further into the cranio-lateral and cranio-medial directions on MRI when compared with CT. Interobserver variability is comparable for both imaging modalities. Observers should be aware of existing personal delineation preferences. Institutions are recommended to review and discuss target volume delineations and to design supplementary guidelines if necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variation in the Gross Tumor Volume and Clinical Target Volume for Preoperative Radiotherapy of Primary Large High-Grade Soft Tissue Sarcoma of the Extremity Among RTOG Sarcoma Radiation Oncologists

Purpose: To evaluate variability in the definition of preoperative radiotherapy gross tumor volume (GTV) and clinical target volume (CTV) delineated by sarcoma radiation oncologists. Methods and Materials: Extremity sarcoma planning CT images along with the corresponding diagnostic MRI from two patients were distributed to 10 Radiation Therapy Oncology Group sarcoma radiation oncologists with instructions to define GTV and CTV using standardized guidelines. The CT data with contours were then returned for central analysis. Contours representing statistically corrected 95% (V95) and 100% (V100) agreement were computed for each structure. Results: For the GTV, the minimum, maximum, mean (SD) volumes (mL) were 674, 798, 752 {+-} 35 for the lower extremity case and 383, 543, 447 {+-} 46 for the upper extremity case. The volume (cc) of the union, V95 and V100 were 882, 761, and 752 for the lower, and 587, 461, and 455 for the upper extremity, respectively. The overall GTV agreement was judged to be almost perfect in both lower and upper extremity cases (kappa = 0.9 [p < 0.0001] and kappa = 0.86 [p < 0.0001]). For the CTV, the minimum, maximum, mean (SD) volumes (mL) were 1145, 1911, 1605 {+-} 211 for the lower extremity case and 637, 1246, 1006 {+-} 180 for the upper extremity case. The volume (cc) of the union, V95, and V100 were 2094, 1609, and 1593 for the lower, and 1533, 1020, and 965 for the upper extremity cases, respectively. The overall CTV agreement was judged to be almost perfect in the lower extremity case (kappa = 0.85 [p < 0.0001]) but only substantial in the upper extremity case (kappa = 0.77 [p < 0.0001]). Conclusions: Almost perfect agreement existed in the GTV of these two representative cases. Tshere was no significant disagreement in the CTV of the lower extremity, but variation in the CTV of upper extremity was seen, perhaps related to the positional differences between the planning CT and the diagnostic MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volume III. DUNE far detector technical coordination

The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume III of this TDR describes how the activities required to design, construct, fabricate, install, and commission the DUNE far detector modules are organized and managed. This volume details the organizational structures that will carry out and/or oversee the planned far detector activities safely, successfully, on time, and on budget. It presents overviews of the facilities, supporting infrastructure, and detectors for context, and it outlines the project-related functions and methodologies used by the DUNE technical coordination organization, focusing on the areas of integration engineering, technical reviews, quality assurance and control, and safety oversight. Because of its more advanced stage of development, functional examples presented in this volume focus primarily on the single-phase (SP) detector module.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A framework to measure myocardial extracellular volume fraction using dual-phase low dose CT images

Purpose: Myocardial extracellular volume fraction (ECVF) is a surrogate imaging biomarker of diffuse myocardial fibrosis, a hallmark of pathologic ventricular remodeling. Low dose cardiac CT is emerging as a promising modality to detect diffuse interstitial myocardial fibrosis due to its fast acquisition and low radiation; however, the insufficient contrast in the low dose CT images poses great challenge to measure ECVF from the image. Methods: To deal with this difficulty, the authors present a complete ECVF measurement framework including a point-guided myocardial modeling, a deformable model-based myocardium segmentation, nonrigid registration of pre- and post-CT, and ECVF calculation. Results: The proposed method was evaluated on 20 patients by two observers. Compared to the manually delineated reference segmentations, the accuracy of our segmentation in terms of true positive volume fraction (TPVF), false positive volume fraction (FPVF), and average surface distance (ASD), were 92.18% ± 3.52%, 0.31% ± 0.10%, 0.69 ± 0.14 mm, respectively. The interobserver variability measured by concordance correlation coefficient regarding TPVF, FPVF, and ASD were 0.95, 0.90, 0.94, respectively, demonstrating excellent agreement. Bland-Altman method showed 95% limits of agreement between ECVF at CT and ECVF at MR. Conclusions: The proposed framework demonstrates its efficiency, accuracy, and noninvasiveness in ECVF measurement and dramatically advances the ECVF at cardiac CT toward its clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helium-volume dynamics of Upper Freeport coal powder and lumps

Exposure to 7 MPa of helium at room temperature alters the texture of Upper Freeport coal in a lump form. The differences in texture and porosity between coal powder and lumps may affect the transport and interaction of fluids and coal. In this work, the information about the coal texture and micro- and meso-porosity was obtained via the BET, BJH, and Dubinin–Astakhov analyses. We further investigated the free-fluid-phase volume (free-volume) effects due to helium interaction with the powder and the lumps. During the manometric experiment, helium penetration into the dry coal matrix resulted in slow relaxation of pressure. After exposure of coal to helium, there have been no significant changes of the macroscopic dimensions observed and the relaxation process can be attributed to microscopic ‘free-volume’ effects. Evolution of the sorption–desorption rates indicates that exposure to helium may change the texture and apparent (helium) density of dry coal.

ADSORPTION HEAT↗

SU-E-J-241: Wavelet-Based Temporal Feature Extraction From DCE-MRI to Identify Sub-Volumes of Low Blood Volume in Head-And-Neck Cancer

Purpose: A previous study showed that large sub-volumes of tumor with low blood volume (BV) (poorly perfused) in head-and-neck (HN) cancers are significantly associated with local-regional failure (LRF) after chemoradiation therapy, and could be targeted with intensified radiation doses. This study aimed to develop an automated and scalable model to extract voxel-wise contrast-enhanced temporal features of dynamic contrastenhanced (DCE) MRI in HN cancers for predicting LRF. Methods: Our model development consists of training and testing stages. The training stage includes preprocessing of individual-voxel DCE curves from tumors for intensity normalization and temporal alignment, temporal feature extraction from the curves, feature selection, and training classifiers. For feature extraction, multiresolution Haar discrete wavelet transformation is applied to each DCE curve to capture temporal contrast-enhanced features. The wavelet coefficients as feature vectors are selected. Support vector machine classifiers are trained to classify tumor voxels having either low or high BV, for which a BV threshold of 7.6% is previously established and used as ground truth. The model is tested by a new dataset. The voxel-wise DCE curves for training and testing were from 14 and 8 patients, respectively. A posterior probability map of the low BV class was created to examine the tumor sub-volume classification. Voxel-wise classification accuracy was computed to evaluate performance of the model. Results: Average classification accuracies were 87.2% for training (10-fold crossvalidation) and 82.5% for testing. The lowest and highest accuracies (patient-wise) were 68.7% and 96.4%, respectively. Posterior probability maps of the low BV class showed the sub-volumes extracted by our model similar to ones defined by the BV maps with most misclassifications occurred near the sub-volume boundaries. Conclusion: This model could be valuable to support adaptive clinical trials with further validation. The framework could be extendable and scalable to extract temporal contrastenhanced features of DCE-MRI in other tumors. We would like to acknowledge NIH for funding support: UO1 CA183848.

60 APPLIED LIFE SCIENCES↗

Table and charts of equilibrium normal-shock properties for hydrogen-helium mixtures with velocities to 70 km/sec. Volume 1: 0.95 H2-0.05 He (by volume)

Equilibrium thermodynamic and flow properties are presented in tabulated and graphical form for moving, standing, and reflected normal shock waves into hydrogen-helium mixtures representative of postulated outer planet atmospheres. These results are presented in four volumes and the volmetric compositions of the mixtures are 0.95H2-0.05He in Volume 1, 0.90H2-0.10He in Volume 2, 0.85H2-0.15He in Volume 3, and 0.75H2-0.25He in Volume 4. Properties include pressure, temperature, density, enthalpy, speed of sound, entropy, molecular-weight ratio, isentropic exponent, velocity, and species mole fractions. Incident (moving) shock velocities are varied from 4 to 70 km/sec for a range of initial pressure of 5 N/sq m to 100 kN/sq m. Results are applicable to shock-tube flows and for determining flow conditions behind the normal portion of the bow shock about a blunt body at high velocities in postulated outer planet atmospheres. The document is a revised version of the original edition of NASA SP-3085 published in 1974.

Miller, C. G., III↗

A robust and efficient finite volume method for compressible inviscid and viscous two-phase flows [A robust and efficient finite volume method for compressible viscous two-phase flows]

A robust and efficient density-based finite volume method is developed for solving the six-equation single pressure system of two-phase flows at all speeds on hybrid unstructured grids. Unlike conventional approaches where an expensive exact Riemann solver is normally required for computing numerical fluxes at the two-phase interfaces in addition to AUSM-type fluxes for single-phase interfaces in order to maintain stability and robustness in cases involving interactions of strong pressure and void-fraction discontinuities, a volume-fraction coupling term for the AUSM + -up fluxes is introduced in this work to impart the required robustness without the need of the exact Riemann solver. The resulting method is significantly less expensive in regions where otherwise the Riemann solver would be invoked. A transformation from conservative variables to primitive variables is presented and the primitive variables are then solved in the implicit method in order for the current finite volume method to be able to solve, effectively and efficiently, low Mach number flows in traditional multiphase applications, which otherwise is a great challenge for the standard density-based algorithms. Here, a number of benchmark test cases are presented to assess the performance and robustness of the developed finite volume method for both inviscid and viscous two-phase flow problems. The numerical results indicate that the current density-based method provides an attractive and viable alternative to its pressure-based counterpart for compressible two-phase flows at all speeds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Variations of target volume definition and daily target volume localization in stereotactic body radiotherapy for early-stage non–small cell lung cancer patients under abdominal compression

We aimed to compare gross tumor volumes (GTV) in 3-dimensional computed tomography (3DCT) simulation and daily cone beam CT (CBCT) with the internal target volume (ITV) in 4-dimensional CT (4DCT) simulation in stereotactic body radiotherapy (SBRT) treatment of patients with early-stage non–small cell lung cancer (NSCLC) under abdominal compression. We retrospectively selected 10 patients with NSCLC who received image-guided SBRT treatments under abdominal compression with daily CBCT imaging. GTVs were contoured as visible gross tumor on the planning 3DCT and daily CBCT, and ITVs were contoured using maximum intensity projection (MIP) images of the planning 4DCT. Daily CBCTs were registered with 3DCT and MIP images by matching of bony landmarks in the thoracic region to evaluate interfractional GTV position variations. Relative to MIP-based ITVs, the average 3DCT-based GTV volume was 66.3 ± 17.1% (range: 37.5% to 92.0%) (p < 0.01 in paired t-test), and the average CBCT-based GTV volume was 90.0 ± 6.7% (daily range: 75.7% to 107.1%) (p = 0.02). Based on bony anatomy matching, the center-of-mass coordinates for CBCT-based GTVs had maximum absolute shift of 2.4 mm (left-right), 7.0 mm (anterior-posterior [AP]), and 5.2 mm (superior-inferior [SI]) relative to the MIP-based ITV. CBCT-based GTVs had average overlapping ratio of 81.3 ± 11.2% (range: 45.1% to 98.9%) with the MIP-based ITV, and 57.7 ± 13.7% (range: 35.1% to 83.2%) with the 3DCT-based GTV. Even with abdominal compression, both 3DCT simulations and daily CBCT scans significantly underestimated the full range of tumor motion. In daily image-guided patient setup corrections, automatic bony anatomy-based image registration could lead to target misalignment. Soft tissue-based image registration should be performed for accurate treatment delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurements of long-wavelength spin waves for the magnetic field in the Damon-Eshbach, backward-volume and forward-volume geometries of an yttrium iron garnet film

In this paper, we report systematic measurements of the dispersion of long wavelength spin waves for a wide range of wave vectors for the magnetic field along the three principal directions defining the forward volume, backward volume and Damon-Eshbach modes of a 9.72 μm thick film of an yttrium iron garnet obtained using lithographically patterned, multi-element, spatially resonant, antennas. Overall good agreement is found between the experimental data for the backward volume and Damon-Eshbach modes and the magnetostatic theory of Damon and Eshbach. Also, good agreement is found between the experimental data for the forward volume mode and the theory of Damon and van de Vaart.

36 MATERIALS SCIENCE↗