Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Estimating Residual Solids Volume In Underground Storage Tanks

The Savannah River Site liquid waste system consists of multiple facilities to safely receive and store legacy radioactive waste, treat, and permanently dispose waste. The large underground storage tanks and associated equipment, known as the 'tank farms', include a complex interconnected transfer system which includes underground transfer pipelines and ancillary equipment to direct the flow of waste. The waste in the tanks is present in three forms: supernatant, sludge, and salt. The supernatant is a multi-component aqueous mixture, while sludge is a gel-like substance which consists of insoluble solids and entrapped supernatant. The waste from these tanks is retrieved and treated as sludge or salt. The high level (radioactive) fraction of the waste is vitrified into a glass waste form, while the low-level waste is immobilized in a cementitious grout waste form called saltstone. Once the waste is retrieved and processed, the tanks are closed via removing the bulk of the waste, chemical cleaning, heel removal, stabilizing remaining residuals with tailored grout formulations and severing/sealing external penetrations. The comprehensive liquid waste disposition system, currently managed by Savannah River Remediation, consists of 1) safe storage and retrieval of the waste as it is prepared for permanent disposition; (2) definition of the waste processing techniques utilized to separate the high-level waste fraction/low-level waste fraction; (3) disposition of LLW in saltstone; (4) disposition of the HLW in glass; and (5) closure state of the facilities, including tanks. This paper focuses on determining the effectiveness of waste removal campaigns through monitoring the volume of residual solids in the waste tanks. Volume estimates of the residual solids are performed by creating a map of the residual solids on the waste tank bottom using video and still digital images. The map is then used to calculate the volume of solids remaining in the waste tank. The ability to accurately determine a volume is a function of the quantity and quality of the waste tank images. Currently, mapping is performed remotely with closed circuit video cameras and still photograph cameras due to the hazardous environment. There are two methods that can be used to create a solids volume map. These methods are: liquid transfer mapping / post transfer mapping and final residual solids mapping. The task is performed during a transfer because the liquid level (which is a known value determined by a level measurement device) is used as a landmark to indicate solids accumulation heights. The post transfer method is primarily utilized after the majority of waste has been removed. This method relies on video and still digital images of the waste tank after the liquid transfer is complete to obtain the relative height of solids across a waste tank in relation to known and usable landmarks within the waste tank (cooling coils, column base plates, etc.). In order to accurately monitor solids over time across various cleaning campaigns, and provide a technical basis to support final waste tank closure, a consistent methodology for volume determination has been developed and implemented at SRS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimating Highway Volumes Using Vehicle Probe Data - Proof of Concept: Preprint

This paper examines the feasibility of using sampled commercial probe data in combination with validated continuous counter data to accurately estimate vehicle volume across the entire roadway network, for any hour during the year. Currently either real time or archived volume data for roadways at specific times are extremely sparse. Most volume data are average annual daily traffic (AADT) measures derived from the Highway Performance Monitoring System (HPMS). Although methods to factor the AADT to hourly averages for typical day of week exist, actual volume data is limited to a sparse collection of locations in which volumes are continuously recorded. This paper explores the use of commercial probe data to generate accurate volume measures that span the highway network providing ubiquitous coverage in space, and specific point-in-time measures for a specific date and time. The paper examines the need for the data, fundamental accuracy limitations based on a basic statistical model that take into account the sampling nature of probe data, and early results from a proof of concept exercise revealing the potential of probe type data calibrated with public continuous count data to meet end user expectations in terms of accuracy of volume estimates.

25 ENERGY STORAGE↗

Release of magmatic water on Mars: Estimated timing and volumes

By estimating the total amount of water released by volcanic processes on Mars, the abundance of H2O at 10 m was estimated. This value was based on mapping volcanic units, estimating thicknesses and volumes, and using a 10 wt. percent value H2O from terrestrial analogs. By combining such estimates with crater count ages, it is also possible to estimate the timing of water release through Martian history.

Greeley, R.↗

Estimating forest biomass and volume using airborne laser data

An airborne pulsed laser system was used to obtain canopy height data over a southern pine forest in Georgia in order to predict ground-measured forest biomass and timber volume. Although biomass and volume estimates obtained from the laser data were variable when compared with the corresponding ground measurements site by site, the present models are found to predict mean total tree volume within 2.6 percent of the ground value, and mean biomass within 2.0 percent. The results indicate that species stratification did not consistently improve regression relationships for four southern pine species.

Nelson, Ross↗

Using multiple x-ray emission images of inertially confined implosions to identify spatial variations and estimate confinement volumes (invited)

We describe two methods to analyze multiple x-ray images of a small, self-emitting object, and we apply these methods to the stagnating hotspots in inertial confinement fusion experiments. The first method, the common integrated profile, can be employed to assess and quantify spatial variations in opacity. It is both a simple assessment of consistency and a sophisticated measurement of variations in a region that is otherwise difficult to observe. Second, we present a method to estimate volumes of highly asymmetric objects using multiple images of x-ray emission. The method is based on image intensities and does not require any explicit assumption of symmetry

47 OTHER INSTRUMENTATION↗

Automated and Manual Rocket Crater Measurement Software

An update has been performed to software designed to do very rapid automated measurements of craters created in sandy substrates by rocket exhaust on liftoff. The previous software was optimized for pristine lab geometry and lighting conditions. This software has been enhanced to include a section for manual measurements of crater parameters; namely, crater depth, crater full width at half max, and estimated crater volume. The tools provide a very rapid method to measure these manual parameters to ease the burden of analyzing large data sets. This software allows for rapid quantization of the rocket crater parameters where automated methods may not work. The progress of spreadsheet data is continuously saved so that data is never lost, and data can be copied to clipboards and pasted to other software for analysis. The volume estimation of a crater is based on the central max depth axis line, and the polygonal shape of the crater is integrated around that axis.

Metzger, Philip↗

Evaluation of the Waste Streams from Management of Reprocessing Off-Gas Streams - 18483

Nuclear fuel reprocessing is being considered in the United States as part of an effort to help meet US energy needs and as a means to improve waste management. During the chemical processing of UNF to recover the valuable components for reuse, a number of volatile radionuclides will be released into the off-gas streams of the reprocessing plant. These volatile radionuclides include H-3, C-14, Kr-85, and I-129. Off-gas abatement systems for the volatile radionuclides will be required to ensure that air emissions from a UNF reprocessing facility can meet or exceed emission requirements set forth by the US Environmental Protection Agency and the US Nuclear Regulatory Commission. An initial engineering evaluation of offgas abatement systems was completed recently. The evaluation addressed the designs of the head-end offgas treatment system, which typically includes both the shear off-gas and the dissolver off-gas and vessel off-gas treatment system. Based on this study, the waste volumes for each of the four primary volatile radionuclides (H-3, C-14, Kr-85, and I-129) were estimated. Included in these estimates were the nonradioactive isotopes and the 'tramp' elements found in air (e.g., Kr and C-12 as CO{sub 2}) and process chemicals (e.g., I and Cl). Because the final waste form for these radionuclides has not been selected, estimated volumes were calculated for various alternative waste forms as appropriate. The resulting waste volume for I was found to be highly dependent on the final waste form selected and increased by a factor of 2 to 4 by tramp halogens that would be released into the off-gas stream from the process chemicals. The volume of tritiated water from the fuel was quite small, but the estimated volume of the final waste form depended on the tritium management approach employed within the reprocessing plant. The Kr waste volume was calculated assuming pure Kr (i.e., assuming complete separation of Xe and Ar). For the case of no Xe separation, the estimated waste volume increased by factor of ∼10. Argon from the air, if not removed, increased the estimated volume by a factor of 425. The estimated volume of C-14 waste was dominated by the CO{sub 2} from the air leaking into the processing cell. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimating traffic volumes for signalized intersections using connected vehicle data

Recently connected vehicle (CV) technology has received significant attention thanks to active pilot deployments supported by the US Department of Transportation (USDOT). At signalized intersections, CVs may serve as mobile sensors, providing opportunities of reducing dependencies on conventional vehicle detectors for signal operation. However, most of the existing studies mainly focus on scenarios that penetration rates of CVs reach certain level, e.g., 25%, which may not be feasible in the near future. How to utilize data from a small number of CVs to improve traffic signal operation remains an open question. In this work, we develop an approach to estimate traffic volume, a key input to many signal optimization algorithms, using GPS trajectory data from CV or navigation devices under low market penetration rates. To estimate traffic volumes, we model in this paper vehicle arrivals at signalized intersections as a time-dependent Poisson process, which can account for signal coordination. The estimation problem is formulated as a maximum likelihood problem given multiple observed trajectories from CVs approaching to the intersection. An expectation maximization (EM) procedure is derived to solve the estimation problem. Two case studies were conducted to validate our estimation algorithm. One uses the CV data from the Safety Pilot Model Deployment (SPMD) project, in which around 2800 CVs were deployed in the City of Ann Arbor, MI. The other uses vehicle trajectory data from users of a commercial navigation service in China. Mean absolute percentage error (MAPE) of the estimation is found to be 9–12%, based on benchmark data manually collected and data from loop detectors. Finally, considering the existing scale of CV deployments, the proposed approach could be of significant help to traffic management agencies for evaluating and operating traffic signals, paving the way of using CVs for detector-free signal operation in the future.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-12: A New Stereological Method for Tumor Volume Evaluation for Esophageal Cancer

Purpose: Stereological method used to obtain three dimensional quantitative information from two dimensional images is a widely used tool in the study of cells and pathology. But the feasibility of the method for quantitative evaluation of volumes with 3D image data sets for radiotherapy clinical application has not been explored. On the other hand, a quick, easy-to-use and reliable method is highly desired in image-guided-radiotherapy(IGRT) for tumor volume measurement for the assessment of response to treatment. To meet this need, a stereological method for evaluating tumor volumes for esophageal cancer is presented in this abstract. Methods: The stereology method was optimized by selecting the appropriate grid point distances and sample types. 7 patients with esophageal cancer were selected retrospectively for this study, each having pre and post treatment computed tomography (CT) scans. Stereological measurements were performed for evaluating the gross tumor volume (GTV) changes after radiotherapy and the results was compared with the ones by planimetric measurements. Two independent observers evaluated the reproducibility for volume measurement using the new stereological technique. Results: The intraobserver variation in the GTV volume estimation was 3.42±1.68cm3 (the Wilcoxon matched-pairs test Resultwas Z=−1.726,P=0.084>0.05); the interobserver variation in the GTV volume estimation was 22.40±7.23 cm3 (Z=−3.296,P=0.083>0.05), which showed the consistency in GTV volume calculation with the new method for the same and different users. The agreement level between the results from the two techniques was also evaluated. Difference between the measured GTVs was 20.10±5.35 cm3 (Z=−3.101,P=0.089>0.05). Variation of the measurement results using the two techniques was low and clinically acceptable. Conclusion: The good agreement between stereological and planimetric techniques proves the reliability of the stereological tumor volume estimations. The optimized stereological technique described in this abstract may provide a quick, unbiased and reproducible tool for tumor volume estimation for treatment response assessment. Supported by NSFC (#81041107, #81171342 and #31000784)

60 APPLIED LIFE SCIENCES↗

Inter-slice bidirectional registration-based segmentation of the prostate gland in MR and CT image sequences

Purpose: Accurate segmentation and volume estimation of the prostate gland in magnetic resonance (MR) and computed tomography (CT) images are necessary steps in diagnosis, treatment, and monitoring of prostate cancer. This paper presents an algorithm for the prostate gland volume estimation based on the semiautomated segmentation of individual slices in T2-weighted MR and CT image sequences. Methods: The proposedInter-Slice Bidirectional Registration-based Segmentation (iBRS) algorithm relies on interslice image registration of volume data to segment the prostate gland without the use of an anatomical atlas. It requires the user to mark only three slices in a given volume dataset, i.e., the first, middle, and last slices. Next, the proposed algorithm uses a registration algorithm to autosegment the remaining slices. We conducted comprehensive experiments to measure the performance of the proposed algorithm using three registration methods (i.e., rigid, affine, and nonrigid techniques). Results: The results with the proposed technique were compared with manual marking using prostate MR and CT images from 117 patients. Manual marking was performed by an expert user for all 117 patients. The median accuracies for individual slices measured using the Dice similarity coefficient (DSC) were 92% and 91% for MR and CT images, respectively. The iBRS algorithm was also evaluated regarding user variability, which confirmed that the algorithm was robust to interuser variability when marking the prostate gland. Conclusions: The proposed algorithm exploits the interslice data redundancy of the images in a volume dataset of MR and CT images and eliminates the need for an atlas, minimizing the computational cost while producing highly accurate results which are robust to interuser variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An in-situ view cell system for investigating swelling behavior of elastomers upon high-pressure hydrogen exposure

The transition to hydrogen as a clean and efficient energy carrier is impeded by challenges in the compatibility of hydrogen with materials used within hydrogen infrastructure. Elastomers, crucial in sealing components, often exhibit premature failures in high-pressure hydrogen environments due to excessive swelling. This study employs an innovative in-situ view cell system to assess the swelling behavior of hydrogenated nitrile butadiene rubber (HNBR) under various hydrogen conditions. The system, designed to withstand pressures up to 96.5 MPa, incorporates Digital Image Correlation (DIC) for strain measurements and volume estimation. Results reveal non-linear volume increases during depressurization, challenging conventional assumptions. Furthermore, investigations into peak hydrogen pressures and pressure-holding scenarios during decompression highlight complex swelling trends. The introduction of a novel computer vision (CV) method enhances precision in volume estimation, overcoming DIC limitations. The study provides insights into mitigating elastomer swelling, crucial for developing robust materials to support future hydrogen-driven energy systems.

Elastomer↗

SU-E-T-319: The Effect of Slice Thickness On IMRT Planning

Purpose: The accuracy of volume estimated of a treatment planning system is investigated in this study. In addition, the effect of slice thickness on IMRT planning is also studied. Methods: The accuracy in volume determination was investigated using a water phantom containing various objects with known volumes ranging from 1–100cm{sup 3}. The phantom was scanned with different slice thickness (1–10 mm). The CT data sets were sent to Eclipse TPS for contour delineation and volume calculation. The effect of slice thickness on IMRT planning was studied using a commercial phantom containing four different shaped objects. The phantom was scanned with different slice thickness (1–5 mm). IMRT plans were generated for the different CT datasets to calculate TCP, homogeneity (HI) and conformity indices (CI). Results: The variability of volumes with CT slice thickness was significant especially for small volume structures. The minimum and maximum error in the volume estimation is in the range of −2.3% to 92%. On the other hand, with increasing slice thickness, the PTV mean dose and TCP values decreases. Maximum variation of ∼5% was observed in mean dose and ∼2% in TCP with slice thickness change from 1–5 mm. The relative decrease in target volume receiving 95% of prescribed dose is ∼5% slice thickness change from 1–5 mm. HI increases up to 163% and CI decreases by 4% between 1–5 mm slice thickness change, producing highly inhomogeneous and least conformal plan. Conclusion: Accuracy of volume estimation is dependent on CT slice thickness and the contouring algorithm in a TPS. During TPS commissioning and for all clinical protocols, evaluation of volume should be included to provide the limit of accuracy in DVH calculation. A smaller slice thickness provides superior dosimetry with improved TCP values. Thus, the smallest possible slice thickness should be used for IMRT planning.

07 ISOTOPE AND RADIATION SOURCES↗

Simple estimate of critical volume

Method for estimating critical molar volume of materials is faster and simpler than previous procedures. Formula sums no more than 18 different contributions from components of chemical structure of material, and is as accurate (within 3 percent) as older more complicated models. Method should expedite many thermodynamic design calculations.

Fedors, R. F.↗

Contour interpolated radial basis functions with spline boundary correction for fast 3D reconstruction of the human articular cartilage from MR images

Purpose: The aim of this work is to demonstrate a new image processing technique that can provide a “near real-time” 3D reconstruction of the articular cartilage of the human knee from MR images which is user friendly. This would serve as a point-of-care 3D visualization tool which would benefit a consultant radiologist in the visualization of the human articular cartilage. Methods: The authors introduce a novel fusion of an adaptation of the contour method known as “contour interpolation (CI)” with radial basis functions (RBFs) which they describe as “CI-RBFs.” The authors also present a spline boundary correction which further enhances volume estimation of the method. A subject cohort consisting of 17 right nonpathological knees (ten female and seven male) is assessed to validate the quality of the proposed method. The authors demonstrate how the CI-RBF method dramatically reduces the number of data points required for fitting an implicit surface to the entire cartilage, thus, significantly improving the speed of reconstruction over the comparable RBF reconstruction method of Carr. The authors compare the CI-RBF method volume estimation to a typical commercial package (3D DOCTOR), Carr’s RBF method, and a benchmark manual method for the reconstruction of the femoral, tibial, and patellar cartilages. Results: The authors demonstrate how the CI-RBF method significantly reduces the number of data points (p-value < 0.0001) required for fitting an implicit surface to the cartilage, by 48%, 31%, and 44% for the patellar, tibial, and femoral cartilages, respectively. Thus, significantly improving the speed of reconstruction (p-value < 0.0001) by 39%, 40%, and 44% for the patellar, tibial, and femoral cartilages over the comparable RBF model of Carr providing a near real-time reconstruction of 6.49, 8.88, and 9.43 min for the patellar, tibial, and femoral cartilages, respectively. In addition, it is demonstrated how the CI-RBF method matches the volume estimation of a typical commercial package (3D DOCTOR), Carr’s RBF method, and a benchmark manual method for the reconstruction of the femoral, tibial, and patellar cartilages. Furthermore, the performance of the segmentation method used for the extraction of the femoral, tibial, and patellar cartilages is assessed with a Dice similarity coefficient, sensitivity, and specificity measure providing high agreement to manual segmentation. Conclusions: The CI-RBF method provides a fast, accurate, and robust 3D model reconstruction that matches Carr’s RBF method, 3D DOCTOR, and a manual benchmark method in accuracy and significantly improves upon Carr’s RBF method in data requirement and computational speed. In addition, the visualization tool has been designed to quickly segment MR images requiring only four mouse clicks per MR image slice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Forest Classification and Inventory System using Landsat, digital terrain, and ground sample data

Accurate timber inventory data for cost-effective forest management is the primary goal of a Forest Classification and Inventory System (FOCIS) designed to provide estimates of timber volume by species aggregated by compartments, townships, or other spatial management units. FOCIS uses Landsat spectral data, including a synthesized texture channel, and Forest Service ground sample data to produce timber volume-homogeneous classes through a two-step unsupervised clustering process. Registered digital terrain data, including derived slope angle and slope aspect channels, are used to predict species proportions through a trend surface model, again using ground sample data for model calibration. In the final stage of FOCIS, volume estimates and predicted species proportions are merged and aggregated to yield timber volumes by species within management areas.

Strahler, A. H.↗

Space Shuttle propulsion parameter estimation using optimal estimation techniques, volume 1

The mathematical developments and their computer program implementation for the Space Shuttle propulsion parameter estimation project are summarized. The estimation approach chosen is the extended Kalman filtering with a modified Bryson-Frazier smoother. Its use here is motivated by the objective of obtaining better estimates than those available from filtering and to eliminate the lag associated with filtering. The estimation technique uses as the dynamical process the six degree equations-of-motion resulting in twelve state vector elements. In addition to these are mass and solid propellant burn depth as the ""system'' state elements. The ""parameter'' state elements can include aerodynamic coefficient, inertia, center-of-gravity, atmospheric wind, etc. deviations from referenced values. Propulsion parameter state elements have been included not as options just discussed but as the main parameter states to be estimated. The mathematical developments were completed for all these parameters. Since the systems dynamics and measurement processes are non-linear functions of the states, the mathematical developments are taken up almost entirely by the linearization of these equations as required by the estimation algorithms.

Source record↗

Integrated Life Cycle and Techno-Economic Assessments of Central Appalachian Legacy Mine Sites for Biomass Development and Waste Coal Utilization

This project, funded by the U.S. Department of Energy – National Energy Technology Laboratory (DOE-NETL) under award DE-FE0032212, evaluated how legacy coal mine lands and coal refuse piles in Central Appalachia (West Virginia and Pennsylvania) can be reclaimed and repurposed to support biomass development and beneficial utilization of waste coal, with the long-term goal of supporting net-zero or net-negative greenhouse gas (GHG) pathways. The project had two primary objectives: 1. Characterize legacy mine sites (including site conditions, waste coal/refuse resources, and soil/ecosystem indicators) and develop reclamation and best management practices (BMPs) for biomass cultivation; and 2. Conduct integrated machine learning (ML)-assisted life cycle assessment (LCA) and techno-economic analysis (TEA) to quantify environmental and economic outcomes for multiple biomass and waste-coal utilization pathways. Across West Virginia, the team identified ~625 coal refuse sites covering ~19,705 acres, and developed methods to estimate refuse pile volume using digital elevation models (DEMs) and geospatial workflows. A large subset of sites received volume estimates totaling ~1.6 billion m³.

01 COAL, LIGNITE, AND PEAT↗