Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Efficient Encoding and Rendering of Time-Varying Volume Data

Visualization of time-varying volumetric data sets, which may be obtained from numerical simulations or sensing instruments, provides scientists insights into the detailed dynamics of the phenomenon under study. This paper describes a coherent solution based on quantization, coupled with octree and difference encoding for visualizing time-varying volumetric data. Quantization is used to attain voxel-level compression and may have a significant influence on the performance of the subsequent encoding and visualization steps. Octree encoding is used for spatial domain compression, and difference encoding for temporal domain compression. In essence, neighboring voxels may be fused into macro voxels if they have similar values, and subtrees at consecutive time steps may be merged if they are identical. The software rendering process is tailored according to the tree structures and the volume visualization process. With the tree representation, selective rendering may be performed very efficiently. Additionally, the I/O costs are reduced. With these combined savings, a higher level of user interactivity is achieved. We have studied a variety of time-varying volume datasets, performed encoding based on data statistics, and optimized the rendering calculations wherever possible. Preliminary tests on workstations have shown in many cases tremendous reduction by as high as 90% in both storage space and inter-frame delay.

CODING↗

The Occlusion Spectrum for Volume Classification and Visualization

Despite the ever-growing improvements on graphics processing units and computational power, classifying 3D volume data remains a challenge. In this paper, we present a new method for classifying volume data based on the ambient occlusion of voxels. This information stems from the observation that most volumes of a certain type, e.g., CT, MRI or flow simulation, contain occlusion patterns that reveal the spatial structure of their materials or features. Furthermore, these patterns appear to emerge consistently for different data sets of the same type. We call this collection of patterns the \emph{occlusion spectrum} of a dataset. We show that using this occlusion spectrum leads to better two-dimensional transfer functions that can help classify complex data sets in terms of the spatial relationships among features. In general, the ambient occlusion of a voxel can be interpreted as a weighted average of the intensities in a spherical neighborhood around the voxel. Different weighting schemes determine the ability to separate structures of interest in the occlusion spectrum. We present a general methodology for finding such a weighting. We show results of our approach in 3D imaging for different applications, including brain and breast tumor detection and the visualization of turbulent flow.

42 ENGINEERING↗

Vorticity-induced flow-focusing leads to bubble entrainment in an inkjet printhead: Synchrotron x-ray and volume-of-fluid visualizations

The oscillatory flows present in an inkjet printhead can lead to strong deformations of the air-liquid interface at the nozzle exit. Such deformations may lead to an inward directed air jet with bubble pinch-off and the subsequent entrainment of an air bubble, which is highly detrimental to the stability of inkjet printing. Understanding the mechanisms of bubble entrainment is therefore crucial to improving print stability. Here, in the present work, we use ultrafast x-ray phase-contrast imaging and direct numerical simulations based on the volume-of-fluid method to study the mechanisms underlying the bubble entrainment in a piezoacoustic printhead. We first demonstrate good agreement between experiments and numerics. We then show the different classes of bubble pinch-off obtained in experiments, and that those were also captured numerically. The numerical results are then used to show that the baroclinic torque, which is generated at the gas-liquid interface due to the misalignment of density and pressure gradients, results in a flow-focusing effect that drives the formation of the air jet from which a bubble can pinch off.

42 ENGINEERING↗

Bimodal Visualization of Industrial X-Ray and Neutron Computed Tomography Data

Advanced manufacturing creates increasingly complex objects with material compositions that are often difficult to characterize by a single modality. Our collaborating domain scientists are going beyond traditional methods by employing both X-ray and neutron computed tomography to obtain complementary representations expected to better resolve material boundaries. However, the use of two modalities creates its own challenges for visualization, requiring either complex adjustments of bimodal transfer functions or the need for multiple views. Together with experts in nondestructive evaluation, we designed a novel interactive bimodal visualization approach to create a combined view of the co-registered X-ray and neutron acquisitions of industrial objects. Using an automatic topological segmentation of the bivariate histogram of X-ray and neutron values as a starting point, the system provides a simple yet effective interface to easily create, explore, and adjust a bimodal visualization. Here, we propose a widget with simple brushing interactions that enables the user to quickly correct the segmented histogram results. Our semiautomated system enables domain experts to intuitively explore large bimodal datasets without the need for either advanced segmentation algorithms or knowledge of visualization techniques. We demonstrate our approach using synthetic examples, industrial phantom objects created to stress bimodal scanning techniques, and real-world objects, and we discuss expert feedback.

image segmentation↗

Parallel Rendering of Large Time-Varying Volume Data

Interactive visualization of large time-varying 3D volume datasets has been and still is a great challenge to the modem computational world. It stretches the limits of the memory capacity, the disk space, the network bandwidth and the CPU speed of a conventional computer. In this SURF project, we propose to develop a parallel volume rendering program on SGI's Prism, a cluster computer equipped with state-of-the-art graphic hardware. The proposed program combines both parallel computing and hardware rendering in order to achieve an interactive rendering rate. We use 3D texture mapping and a hardware shader to implement 3D volume rendering on each workstation. We use SGI's VisServer to enable remote rendering using Prism's graphic hardware. And last, we will integrate this new program with ParVox, a parallel distributed visualization system developed at JPL. At the end of the project, we Will demonstrate remote interactive visualization using this new hardware volume renderer on JPL's Prism System using a time-varying dataset from selected JPL applications.

Garbutt, Alexander E.↗

Temporal Evolution and Dose-Volume Histogram Predictors of Visual Acuity After Proton Beam Radiation Therapy of Uveal Melanoma

Purpose: To perform an in-depth temporal analysis of visual acuity (VA) outcomes after proton beam radiation therapy (PBRT) in a large, uniformly treated cohort of uveal melanoma (UM) patients, to determine trends in VA evolution depending on pretreatment and temporally defined posttreatment VA measurements; and to investigate the relevance of specific patient, tumor and dose-volume parameters to posttreatment vision loss. Methods and Materials: Uveal melanoma patients receiving PBRT were identified from a prospectively maintained database. Included patients (n=645) received 56 GyE in 4 fractions, had pretreatment best corrected VA (BCVA) in the affected eye of count fingers (CF) or better, with posttreatment VA assessment at specified post-PBRT time point(s). Patients were grouped according to the pretreatment BCVA into favorable (≥20/40) or unfavorable (20/50-20/400) and poor (CF) strata. Temporal analysis of BCVA changes was described, and univariate and forward stepwise multivariate logistic regression analyses were performed to identify predictors for VA loss. Results: Median VA follow-up was 53 months (range, 3-213 months). At 60-month follow up, among evaluable treated eyes with favorable pretreatment BCVA, 45% retained BCVA ≥20/40, whereas among evaluable treated eyes with initially unfavorable/poor BCVA, 21% had vision ≥20/100. Among those with a favorable initial BCVA, attaining BCVA of ≥20/40 at any posttreatment time point was associated with subsequent maintenance of excellent BCVA. Multivariate analysis identified volume of the macula receiving 28GyE (P<.0001) and optic nerve (P=.0004) as independent dose-volume histogram predictors of 48-month post-PBRT vision loss among initially favorable treated eyes. Conclusions: Approximately half of PBRT-treated UM eyes with excellent pretreatment BCVA assessed at 5 years after treatment will retain excellent long-term vision. 28GyE macula and optic nerve dose-volume histogram parameters allow for rational treatment planning optimization that may lead to improved visual outcomes. The detailed temporal analysis with intermediate as well as long-term functional prognosis, and the relationship of outcomes with clinical and treatment planning parameters, is critical for informed care of UM patients before and after PBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Attribute-Aware RBFs: Interactive Visualization of Time Series Particle Volumes Using RT Core Range Queries

Smoothed-particle hydrodynamics (SPH) is a mesh-free method used to simulate volumetric media in fluids, astrophysics, and solid mechanics. Visualizing these simulations is problematic because these datasets often contain millions, if not billions of particles carrying physical attributes and moving over time. Radial basis functions (RBFs) are used to model particles, and overlapping particles are interpolated to reconstruct a high-quality volumetric field; however, this interpolation process is expensive and makes interactive visualization difficult. Existing RBF interpolation schemes do not account for color-mapped attributes and are instead constrained to visualizing just the density field. To address these challenges, we exploit ray tracing cores in modern GPU architectures to accelerate scalar field reconstruction. We use a novel RBF interpolation scheme to integrate per-particle colors and densities, and leverage GPU-parallel tree construction and refitting to quickly update the tree as the simulation animates over time or when the user manipulates particle radii. We also propose a Hilbert reordering scheme to cluster particles together at the leaves of the tree to reduce tree memory consumption. Finally, we reduce the noise of volumetric shadows by adopting a spatially temporal blue noise sampling scheme. Our method can provide a more detailed and interactive view of these large, volumetric, time-series particle datasets than traditional methods, leading to new insights into these physics simulations.

Particle Volumes↗

CoordNet: Data Generation and Visualization Generation for Time-Varying Volumes via a Coordinate-Based Neural Network

Although deep learning has demonstrated its capability in solving diverse scientific visualization problems, it still lacks generalization power across different tasks. To address this challenge, we propose CoordNet, a single coordinate-based framework that tackles various tasks relevant to time-varying volumetric data visualization without modifying the network architecture. The core idea of our approach is to decompose diverse task inputs and outputs into a unified representation (i.e., coordinates and values) and learn a function from coordinates to their corresponding values. We achieve this goal using a residual block-based implicit neural representation architecture with periodic activation functions. We evaluate CoordNet on data generation (i.e., temporal super-resolution and spatial super-resolution) and visualization generation (i.e., view synthesis and ambient occlusion prediction) tasks using time-varying volumetric data sets of various characteristics. Here, the experimental results indicate that CoordNet achieves better quantitative and qualitative results than the state-of-the-art approaches across all the evaluated tasks. Source code and pre-trained models are available at https://github.com/stevenhan1991/CoordNet.

97 MATHEMATICS AND COMPUTING↗

TU-G-BRA-02: Can We Extract Lung Function Directly From 4D-CT Without Deformable Image Registration?

Purpose: Dynamic CT ventilation imaging (CT-VI) visualizes air volume changes in the lung by evaluating breathing-induced lung motion using deformable image registration (DIR). Dynamic CT-VI could enable functionally adaptive lung cancer radiation therapy, but its sensitivity to DIR parameters poses challenges for validation. We hypothesize that a direct metric using CT parameters derived from Hounsfield units (HU) alone can provide similar ventilation images without DIR. We compare the accuracy of Direct and Dynamic CT-VIs versus positron emission tomography (PET) images of inhaled {sup 68}Ga-labelled nanoparticles (‘Galligas’). Methods: 25 patients with lung cancer underwent Galligas 4D-PET/CT scans prior to radiation therapy. For each patient we produced three CT- VIs. (i) Our novel method, Direct CT-VI, models blood-gas exchange as the product of air and tissue density at each lung voxel based on time-averaged 4D-CT HU values. Dynamic CT-VIs were produced by evaluating: (ii) regional HU changes, and (iii) regional volume changes between the exhale and inhale 4D-CT phase images using a validated B-spline DIR method. We assessed the accuracy of each CT-VI by computing the voxel-wise Spearman correlation with free-breathing Galligas PET, and also performed a visual analysis. Results: Surprisingly, Direct CT-VIs exhibited better global correlation with Galligas PET than either of the dynamic CT-VIs. The (mean ± SD) correlations were (0.55 ± 0.16), (0.41 ± 0.22) and (0.29 ± 0.27) for Direct, Dynamic HU-based and Dynamic volume-based CT-VIs respectively. Visual comparison of Direct CT-VI to PET demonstrated similarity for emphysema defects and ventral-to-dorsal gradients, but inability to identify decreased ventilation distal to tumor-obstruction. Conclusion: Our data supports the hypothesis that Direct CT-VIs are as accurate as Dynamic CT-VIs in terms of global correlation with Galligas PET. Visual analysis, however, demonstrated that different CT-VI algorithms might have varying accuracy depending on the underlying cause of ventilation abnormality. This research was supported by a National Health and Medical Research Council (NHMRC) Australia Fellowship, an Cancer Institute New South Wales Early Career Fellowship 13-ECF-1/15 and NHMRC scholarship APP1038399. No commercial funding was received for this work.

60 APPLIED LIFE SCIENCES↗

Visualization and modeling of factors influencing visibility in computer-aided crewstation design

We have developed two modules for use in computer-aided design (CAD) of crewstation environments that enhance the designer's appreciation of factors influencing the pilot's vision and visual processing capacity. The Binocular Optics Module (BOM) is an interactive tool for visualizing geometric aspects of (1) how retinal imagery of the environment changes on the pilot's retinas under conditions of eye and object motion, and (2) how visual capabilities that can be modeled as regions or contours on the retinas, affect spatial perception of the environment. The Visual Performance Module (VPM) contains a signal processing model of human visual discrimination that quantitatively predicts visual discrimination performance. The outputs of the VPM are retinal contours that represent performance probabilities. These contours may be used as inputs to the BOM for visualizing those volumes of space within the crewstation that bound different levels of the pilot's of visual discrimination capability. Used together, the BOM and VPM provide the designer with the opportunity to interactively explore relationships between environmental retinal imagery and visual function, and the ability to factor the pilot's visual capabilities into the earliest phases of crewstation CAD.

Arditi, Aries↗

The quantitative modelling of human spatial habitability

A theoretical model for evaluating human spatial habitability (HuSH) in the proposed U.S. Space Station is developed. Optimizing the fitness of the space station environment for human occupancy will help reduce environmental stress due to long-term isolation and confinement in its small habitable volume. The development of tools that operationalize the behavioral bases of spatial volume for visual kinesthetic, and social logic considerations is suggested. This report further calls for systematic scientific investigations of how much real and how much perceived volume people need in order to function normally and with minimal stress in space-based settings. The theoretical model presented in this report can be applied to any size or shape interior, at any scale of consideration, for the Space Station as a whole to an individual enclosure or work station. Using as a point of departure the Isovist model developed by Dr. Michael Benedikt of the U. of Texas, the report suggests that spatial habitability can become as amenable to careful assessment as engineering and life support concerns.

Wise, James A.↗

Computational Science - Scientific Visualization: Closeout Certifications; CSSV Newsletter Volume I; CSSV Newsletter Volume II; CSSV Activity Journal; CSSV Final Financial Report (Final Technical Progress Report)

This Project's third year of implementation in 2007-2008, the final year, as designated by Elizabeth City State University (ECSU), in cooperation with the National Association of Mathematicians (NAM) Inc., in an effort to promote research and research training programs in computational science & scientific visualization (CSSV). A major goal of the Project was to attract the energetic and productive faculty, graduate and upper division undergraduate students of diverse ethnicities to a program that investigates science and computational science issues of long-term interest to the Department of Energy (DoE) and the nation. The breadth and depth of computational science & scientific visualization and the magnitude of resources available are enormous for permitting a variety of research activities. ECSU's Computational Science-Science Visualization Center will serve as a conduit for directing users to these enormous resources.

97 MATHEMATICS AND COMPUTING↗

Focused Ion Beam Tomography of Alloy 617 Corroded in Molten Chloride Salt

Materials qualification of reactor structural materials is a critical step in rapid implementation of advanced nuclear reactor technologies, particularly to assess the corrosion performance in these designs. Accelerated qualification of reactor structural materials requires incorporating powerful computational toolsets, such as phase field modelling in the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework, to predict the evolution of structural materials due to corrosion. Accordingly, computational toolsets will require experimental data generated at appropriate length scales to validate accuracy. Focused ion beam (FIB) provides a high degree of control over manipulation of materials for analytical purposes, including capturing data on the evolution in the microstructure and elemental composition of materials at the mesoscale, an appropriate length scale for phase field modelling of intergranular diffusion phenomena using the MOOSE framework. For instance, the FEI Helios G4 UX dual beam plasma FIB microscope at the Irradiated Materials Characterization Laboratory (IMCL) is capable of backscatter diffraction (EBSD) and energy-dispersive x-ray spectroscopy (EDS) documenting the evolution in the microstructure and elemental composition, respectively. The Helios can perform EDS and EBSD three-dimensionally (3D) using tomography, which is then combined using different software packages to visualize 3D volumes correlating elemental composition to microstructural data. The purpose of this investigation was to develop a streamlined characterization and data processing workflow for 3D tomography studies on the FEI Helios G4 plasma FIB. The investigation is segmented into three parts: 1) Optimizing the data collection workflow, 2) identifying appropriate data processing and visualization software (i.e. DREAM.3D, MIPAR, and VGStudioMax), and 3) establishing an infrastructure for public release. The optimization of the data collection workflow is in collaboration with members of the U220 department to setup formal training on the tomography operation of the G4, through ThermoFisher Scientific, and exploring DREAM.3D, MIPAR, and VGStudioMax data processing/visualization software packages. VGStudioMax currently demonstrates the most promise for future use. Optimization of the data collection and processing workflow is still ongoing. A collaboration with INL High Performance Computing (HPC) established an open-source license for expediting the public release of FIB tomography datasets through HPC. FIB tomography data generated by the G4 will provide comprehensive data for validating 3D phase field mesoscale modelling tools within the MOOSE framework for accelerated qualification of reactor structural materials.

Copeland-Johnson, Trishelle↗

Strategies for Effectively Visualizing a 3D Flow Using Volume Line Integral Convolution

This paper discusses strategies for effectively portraying 3D flow using volume line integral convolution. Issues include defining an appropriate input texture, clarifying the distinct identities and relative depths of the advected texture elements, and selectively highlighting regions of interest in both the input and output volumes. Apart from offering insights into the greater potential of 3D LIC as a method for effectively representing flow in a volume, a principal contribution of this work is the suggestion of a technique for generating and rendering 3D visibility-impeding 'halos' that can help to intuitively indicate the presence of depth discontinuities between contiguous elements in a projection and thereby clarify the 3D spatial organization of elements in the flow. The proposed techniques are applied to the visualization of a hot, supersonic, laminar jet exiting into a colder, subsonic coflow.

Interrante, Victoria↗

SU-E-J-153: Reconstructing 4D Cone Beam CT Images for Clinical QA of Lung SABR Treatments

Purpose: To verify that the planned Primary Target Volume (PTV) and Internal Gross Tumor Volume (IGTV) fully enclose a moving lung tumor volume as visualized on a pre-SABR treatment verification 4D Cone Beam CT. Methods: Daily 3DCBCT image sets were acquired immediately prior to treatment for 10 SABR lung patients using the on-board imaging system integrated into a Varian TrueBeam (v1.6: no 4DCBCT module available). Respiratory information was acquired during the scan using the Varian RPM system. The CBCT projections were sorted into 8 bins offline, both by breathing phase and amplitude, using in-house software. An iterative algorithm based on total variation minimization, implemented in the open source reconstruction toolkit (RTK), was used to reconstruct the binned projections into 4DCBCT images. The relative tumor motion was quantified by tracking the centroid of the tumor volume from each 4DCBCT image. Following CT-CBCT registration, the planning CT volumes were compared to the location of the CBCT tumor volume as it moves along its breathing trajectory. An overlap metric quantified the ability of the planned PTV and IGTV to contain the tumor volume at treatment. Results: The 4DCBCT reconstructed images visibly show the tumor motion. The mean overlap between the planned PTV (IGTV) and the 4DCBCT tumor volumes was 100% (94%), with an uncertainty of 5% from the 4DCBCT tumor volume contours. Examination of the tumor motion and overlap metric verify that the IGTV drawn at the planning stage is a good representation of the tumor location at treatment. Conclusion: It is difficult to compare GTV volumes from a 4DCBCT and a planning CT due to image quality differences. However, it was possible to conclude the GTV remained within the PTV 100% of the time thus giving the treatment staff confidence that SABR lung treatements are being delivered accurately.

60 APPLIED LIFE SCIENCES↗