Search NASA⌕ Search

SEARCH · Search NASA

Results for “wakefields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Acceleration of electrons in the plasma wakefield of a proton bunch

High-energy particle accelerators have been crucial in providing a deeper understanding of fundamental particles and the forces that govern their interactions. To increase the energy of the particles or to reduce the size of the accelerator, new acceleration schemes need to be developed. Plasma wakefield acceleration, in which the electrons in a plasma are excited, leading to strong electric fields (so called ‘wakefields’), is one such promising acceleration technique. Experiments have shown that an intense laser pulse or electron bunch traversing a plasma can drive electric fields of tens of gigavolts per metre and above—well beyond those achieved in conventional radio-frequency accelerators (about 0.1 gigavolt per metre). However, the low stored energy of laser pulses and electron bunches means that multiple acceleration stages are needed to reach very high particle energies. The use of proton bunches is compelling because they have the potential to drive wakefields and to accelerate electrons to high energy in a single acceleration stage. Long, thin proton bunches can be used because they undergo a process called self-modulation, a particle–plasma interaction that splits the bunch longitudinally into a series of high-density microbunches, which then act resonantly to create large wakefields. The Advanced Wakefield (AWAKE) experiment at CERN uses high-intensity proton bunches—in which each proton has an energy of 400 gigaelectronvolts, resulting in a total bunch energy of 19 kilojoules—to drive a wakefield in a ten-metre-long plasma. Electron bunches are then injected into this wakefield. Here we present measurements of electrons accelerated up to two gigaelectronvolts at the AWAKE experiment, in a demonstration of proton-driven plasma wakefield acceleration. Measurements were conducted under various plasma conditions and the acceleration was found to be consistent and reliable. The potential for this scheme to produce very high-energy electron bunches in a single accelerating stage means that our results are an important step towards the development of future high-energy particle accelerators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase control with two-beam interferometry method in a terahertz dielectric wakefield accelerator

High-gradient, beam-driven wakefield acceleration in THz structures is a promising technology for future free electron lasers and colliders. In this scheme, the main beam is accelerated by the wakefield of the high current drive beam. The time separation between the main and drive beams has to be chosen carefully to ensure that the main beam is in an accelerating phase of the drive's wakefield. THz accelerating structures provide high gradient acceleration due to their small apertures, but their phase control is difficult due to the picosecond-scale period. Here, we report on a wakefield acceleration experiment in a 460 GHz dielectric wakefield accelerator (DWA). The optimum phase of the main beam during the experiment is determined with a two-beam wakefield interferometry (TBI) measurement. This is performed without the measurement of the main and drive beam bunch lengths or their separation. In TBI, the interference of the wakefields produced by the drive and main beams is measured with an integrating THz detector. The TBI signal, as a function of separation between the drive and main beams, exhibits a minimum due to destructive interference of these wakefields, which corresponds to maximum acceleration of the main beam as is confirmed by the energy spectrometer measurement. The maximum energy gain of 0.8 MeV and maximum energy loss of 1.2 MeV for the main beam have been measured, which agrees well with theoretical predictions. Published by AIP Publishing.

43 PARTICLE ACCELERATORS↗

Control of wakefield in sub-THz dielectric-lined waveguides using multiple-bunch excitation

Beam-driven wakefield accelerators offer the potential to achieve accelerating fields approaching the sub-GV/m range, paving the way for compact and cost-effective next-generation high-energy colliders. This method typically employs a two-bunch system: a drive bunch that excites an electromagnetic wakefield in a solid-state or plasma medium, and a witness bunch that extracts energy from the wake for acceleration. Our research focuses on two key challenges in wakefield acceleration using structures. First, we investigate strategies to suppress transverse instabilities by employing non-cylindrical geometries that damp dipole modes. Second, we explore methods to precisely terminate the wakefield after the interaction region, thereby improving the efficiency of energy transfer. This paper presents detailed simulation results and the corresponding experimental design developed to validate these concepts. Furthermore, the proposed experiment will be carried out at the Argonne Wakefield Accelerator (AWA) facility, focusing on controlling wakefield duration through tailored drive and witness bunch configurations and evaluating dielectric-lined structures with non-cylindrical cross sections.

43 PARTICLE ACCELERATORS↗

Generation of wakefields by whistlers in spin quantum magnetoplasmas

The excitation of electrostatic wakefields in a magnetized spin quantum plasma by the classical and the spin-induced ponderomotive force (CPF and SPF, respectively) due to whistler waves is reported. The nonlinear dynamics of the whistlers and the wakefields is shown to be governed by a coupled set of nonlinear Schroedinger and driven Boussinesq-like equations. It is found that the quantum force associated with the Bohm potential introduces two characteristic length scales, which lead to the excitation of multiple wakefields in a strongly magnetized dense plasma (with a typical magnetic field strength B{sub 0} or approx. 10{sup 9} T and particle density n{sub 0} > or approx. 10{sup 36} m{sup -3}), where the SPF strongly dominates over the CPF. In other regimes, namely, B{sub 0} < or approx. 10{sup 8} T and n{sub 0} < or approx. 10{sup 35} m{sup -3}, where the SPF is comparable to the CPF, a plasma wakefield can also be excited self-consistently with one characteristic length scale. Numerical results reveal that the wakefield amplitude is enhanced by the quantum tunneling effect; however, it is lowered by the external magnetic field. Under appropriate conditions, the wakefields can maintain high coherence over multiple plasma wavelengths and thereby accelerate electrons to extremely high energies. The results could be useful for particle acceleration at short scales, i.e., at nanometer and micrometer scales, in magnetized dense plasmas where the driver is the whistler wave instead of a laser or a particle beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of pulse profile and chirp on a laser wakefield generation

A laser wakefield driven by an asymmetric laser pulse with/without chirp is investigated analytically and through two-dimensional particle-in-cell simulations. For a laser pulse with an appropriate pulse length compared with the plasma wavelength, the wakefield amplitude can be enhanced by using an asymmetric un-chirped laser pulse with a fast rise time; however, the growth is small. On the other hand, the wakefield can be greatly enhanced for both positively chirped laser pulse having a fast rise time and negatively chirped laser pulse having a slow rise time. Simulations show that at the early laser-plasma interaction stage, due to the influence of the fast rise time the wakefield driven by the positively chirped laser pulse is more intense than that driven by the negatively chirped laser pulse, which is in good agreement with analytical results. At a later time, since the laser pulse with positive chirp exhibits opposite evolution to the one with negative chirp when propagating in plasma, the wakefield in the latter case grows more intensely. These effects should be useful in laser wakefield acceleration experiments operating at low plasma densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of acceleration and deceleration in gigaelectron-volt-per-metre gradient dielectric wakefield accelerators

There is urgent need to develop new acceleration techniques capable of exceeding gigaelectron-volt-per-metre (GeV m –1 ) gradients in order to enable future generations of both light sources and high-energy physics experiments. To address this need, short wavelength accelerators based on wakefields, where an intense relativistic electron beam radiates the demanded fields directly into the accelerator structure or medium, are currently under intense investigation. One such wakefield based accelerator, the dielectric wakefield accelerator, uses a dielectric lined-waveguide to support a wakefield used for acceleration. Here we show gradients of 1.347±0.020 GeV m –1 using a dielectric wakefield accelerator of 15 cm length, with sub-millimetre transverse aperture, by measuring changes of the kinetic state of relativistic electron beams. We follow this measurement by demonstrating accelerating gradients of 320±17 MeV m –1 . As a result, both measurements improve on previous measurements by and order of magnitude and show promise for dielectric wakefield accelerators as sources of high-energy electrons.

43 PARTICLE ACCELERATORS↗

Plasma Density Tapering for Laser Wakefield Acceleration of Electrons and Protons

Extended acceleration in a Laser Wakefield Accelerator can be achieved by tailoring the phase velocity of the accelerating plasma wave, either through profiling of the density of the plasma or direct manipulation of the phase velocity. Laser wakefield acceleration has also reached a maturity that proton acceleration by wakefield could be entertained provided we begin with protons that are substantially relativistic, {approx}1 GeV. Several plasma density tapering schemes are discussed. The first scheme is called ''bucket jumping'' where the plasma density is abruptly returned to the original density after a conventional tapering to move the accelerating particles to a neighboring wakefield period (bucket). The second scheme is designed to specifically accelerate low energy protons by generating a nonlinear wakefield in a plasma region with close to critical density. The third scheme creates a periodic variation in the phase velocity by beating two intense laser beams with laser frequency difference equal to the plasma frequency. Discussions and case examples with simulations are presented where substantial acceleration of electrons or protons could be obtained.

43 PARTICLE ACCELERATORS↗

A New Type of Plasma Wakefield Accelerator Driven By Magnetowaves

We present a new concept for a plasma wakefield accelerator driven by magnetowaves (MPWA). This concept was originally proposed as a viable mechanism for the 'cosmic accelerator' that would accelerate cosmic particles to ultra-high energies in the astrophysical setting. Unlike the more familiar plasma wakefield accelerator (PWFA) and the laser wakefield accelerator (LWFA) where the drivers, the charged-particle beam and the laser, are independently existing entities, MPWA invokes the high-frequency and high-speed whistler mode as the driver, which is a medium wave that cannot exist outside of the plasma. Aside from the difference in drivers, the underlying mechanism that excites the plasma wakefield via the ponderomotive potential is common. Our computer simulations show that under appropriate conditions, the plasma wakefield maintains very high coherence and can sustain high-gradient acceleration over many plasma wavelengths. We suggest that in addition to its celestial application, the MPWA concept can also be of terrestrial utility. A proof-of-principle experiment on MPWA would benefit both terrestrial and celestial accelerator concepts.

43 PARTICLE ACCELERATORS↗

Results from Plasma Wakefield Experiments at FACET

We report initial results of the Plasma Wakefield Acceleration (PWFA) Experiments performed at FACET - Facility for Advanced aCcelertor Experimental Tests at SLAC National Accelerator Laboratory. At FACET a 23 GeV electron beam with 1.8 x 10{sup 10} electrons is compressed to 20 {mu}m longitudinally and focused down to 10 {mu}m x 10 {mu}m transverse spot size for user driven experiments. Construction of the FACET facility completed in May 2011 with a first run of user assisted commissioning throughout the summer. The first PWFA experiments will use single electron bunches combined with a high density lithium plasma to produce accelerating gradients > 10 GeV/m benchmarking the FACET beam and the newly installed experimental hardware. Future plans for further study of plasma wakefield acceleration will be reviewed. The experimental hardware and operation of the plasma heat-pipe oven have been successfully commissioned. Plasma wakefield acceleration was not observed because the electron bunch density was insufficient to ionize the lithium vapor. The remaining commissioning time in summer 2011 will be dedicated to delivering the FACET design parameters for the experimental programs which will begin in early 2012. PWFA experiments require the shorter bunches and smaller transverse sizes to create the plasma and drive large amplitude wakefields. Low emittance and high energy will minimize head erosion which was found to be a limiting factor in acceleration distance and energy gain. We will run the PWFA experiments with the design single bunch conditions in early 2012. Future PWFA experiments at FACET are discussed in [5][6] and include drive and witness bunch production for high energy beam manipulation, ramped bunch to optimize tranformer ratio, field-ionized cesium plasma, preionized plasmas, positron acceleration, etc.. We will install a notch collimator for two-bunch operation as well as new beam diagnostics such as the X-band TCAV [7] to resolve the two bunches. With these new instruments and desired beam parameters in place next year, we will be able to complete the studies of plasma wakefield acceleration in the next few years.

43 PARTICLE ACCELERATORS↗

Fabrication of THz corrugated wakefield structure and its high power test

We present overall process for developing terahertz (THz) corrugated structure and its beam-based measurement results. 0.2-THz corrugated structures were fabricated by die stamping method as the first step demonstration towards GW THz radiation source and GV/m THz wakefield accelerator. 150-μm thick disks were produced from an OFHC (C10100) foil by stamping. Two types of disks were stacked alternately to form 46 mm structure with ~ 170 corrugations. Custom assembly was designed to provide diffusion bonding with a high precision alignment of disks. The compliance of the fabricated structure have been verified through beam-based wakefield measurement at Argonne Wakefield Accelerator Facility. Both measured longitudinal and transverse wakefield showed good agreement with simulated wakefields. Measured peak gradients, 9.4 MV/m/nC for a long single bunch and 35.4 MV/m/nC for a four bunch trains, showed good agreement with the simulation.

43 PARTICLE ACCELERATORS↗