Morphological stability in the presence of fluid flow in the melt

Recent experiments have shown that the presence of a vertical buoyancy-driven flow adjacent to an initially cylindrical crystal-melt interface may produce a time-dependent helical deformation of the interface, with a rotation period ranging from several minutes to many hours, depending upon the width of the melt. The temperature distribution is such that the interface is expected to be morphologically stable in the absence of fluid flow. A linear stability analysis reveals that the instability is due to a coupling between a basic hydrodynamic instability in the buoyant flow and the deformable boundary separating the two phases. The crystal-melt interface lowers the critical Grashof number of an analogous rigid-walled system by an order of magnitude for succinonitrile with a Prandtl number P = 22.8; furthermore, the hydrodynamic mode that is actually destabilized by the interface is not the least stable mode in the rigid-walled system for P = 22.8. The results show that the instability may be regarded either as a rather large alteration of a basic hydrodynamic instability by the crystal-melt interface, or as a significant modification of the morphological stability of the interface by the presence of the buoyant flow.

Mcfadden, G. B.↗

A wall interference assessment and correction system

A wall signature method has been selected to be adapted for the Ames 12-ft Wind Tunnel WIAC system. This uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used to estimate wall interference at the model location. The development and implementation of a working prototype will be completed, delivered and documented with a software manual.

Lo, C. F.↗

Thermochemistry of tantalum-wall cooling system with lithium and sodium working fluids

Plots are presented which show the distribution of oxygen between liquid lithium and tantalum or niobium, and between liquid sodium and tantalum at elevated temperatures. Additional plots showing the composition of the gas phase above the solutions of oxygen and alkali metal are presented. The use of the plots is illustrated by an example tantalum heat pipe filled with lithium.

Tower, L. K.↗

A low dimensional dynamical system for the wall layer

Low dimensional dynamical systems which model a fully developed turbulent wall layer were derived.The model is based on the optimally fast convergent proper orthogonal decomposition, or Karhunen-Loeve expansion. This decomposition provides a set of eigenfunctions which are derived from the autocorrelation tensor at zero time lag. Via Galerkin projection, low dimensional sets of ordinary differential equations in time, for the coefficients of the expansion, were derived from the Navier-Stokes equations. The energy loss to the unresolved modes was modeled by an eddy viscosity representation, analogous to Heisenberg's spectral model. A set of eigenfunctions and eigenvalues were obtained from direct numerical simulation of a plane channel at a Reynolds number of 6600, based on the mean centerline velocity and the channel width flow and compared with previous work done by Herzog. Using the new eigenvalues and eigenfunctions, a new ten dimensional set of ordinary differential equations were derived using five non-zero cross-stream Fourier modes with a periodic length of 377 wall units. The dynamical system was integrated for a range of the eddy viscosity prameter alpha. This work is encouraging.

Aubry, N.↗

Effective field theory of fluctuating wall in open systems: from a kink in Josephson junction to general domain wall

We investigate macroscopic behaviors of fluctuating domain walls in nonequilibrium open systems with the help of the effective field theory based on symmetry. Since the domain wall in open systems breaks the translational symmetry, there appears a gapless excitation identified as the Nambu-Goldstone (NG) mode, which shows the non-propagating diffusive behavior in contrast to those in closed systems. After demonstrating the presence of the diffusive NG mode in the (2+1)-dimensional dissipative Josephson junction, we provide a symmetry-based general analysis for open systems breaking the one-dimensional translational symmetry. A general effective Lagrangian is constructed based on the Schwinger-Keldysh formalism, which supports the presence of the gapless diffusion mode in the fluctuation spectrum in the thin wall regime. Besides, we also identify a term peculiar to the open system, which possibly leads to the instability in the thick-wall regime or the nonlinear Kardar-Parisi-Zhang coupling in the thin-wall regime although it is absent in the Josephson junction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noise control prediction for high-speed, propeller-driven aircraft

An analytical study is described which explores add-on treatments and advanced concepts for the reduction of noise levels in three high-speed aircraft driven by propellers. Noise reductions of 25 to 28 dB are required to achieve a goal of an A-weighted sound level not greater than 80 dB. It is found that only a double-wall system, with a limp inner wall or trim panel, can achieve the required noise reductions. Weight penalties are estimated for the double-wall treatments. These penalties are 0.75% to 1.51% of the aircraft takeoff weight for the particular baseline designs selected.

Wilby, J. F.↗

A wall interference assessment/correction system

The Hackett method (a Wall Pressure Signature Method) was selected to be adapted for the 12 ft Wind Tunnel WIAC system. This method uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used in term for estimating wall interference at the model location. Hackett's method will have to be formulated for application to the unique geometry of the 12 ft tunnel. The WIAC code will be validated by conducting numerically simulated experiments rather than actual wind tunnel experiments. The simulations will be used to generate both free air and confined wind tunnel flow fields for each of the test articles over a range of test configurations. Specifically the pressure signature at the test section wall will be computed for the confined case to provide the simulated 'measured' data. These data will serve as the input for the WIAC method. The performance of the WIAC method then may be evaluated by comparing the corrected parameters with those for the free air simulation.

Lo, C. F.↗

Implementation of the WICS Wall Interference Correction System at the National Transonic Facility

The Wall Interference Correction System (WICS) is operational at the National Transonic Facility (NTF) of NASA Langley Research Center (NASA LaRC) for semispan and full span tests in the solid wall (slots covered) configuration, The method is based on the wall pressure signature method for computing corrections to the measured parameters. It is an adaptation of the WICS code operational at the 12 ft pressure wind tunnel (12ft PWT) of NASA Ames Research Center (NASA ARC). This paper discusses the details of implementation of WICS at the NTF including, tunnel calibration, code modifications for tunnel and support geometry, changes made for the NTF wall orifices layout, details of interfacing with the tunnel data processing system, and post-processing of results. Example results of applying WICS to a semispan test and a full span test are presented. Comparison with classical correction results and an analysis of uncertainty in the corrections are also given. As a special application of the code, the Mach number calibration data from a centerline pipe test was computed by WICS. Finally, future work for expanding the applicability of the code including online implementation is discussed.

Iyer, Venkit↗

Implementation of the WICS Wall Interference Correction System at the National Transonic Facility

The Wall Interference Correction System (WICS) is operational at the National Transonic Facility (NTF) of NASA Langley Research Center (NASA LaRC) for semispan and full span tests in the solid wall (slots covered) configuration. The method is based on the wall pressure signature method for computing corrections to the measured parameters. It is an adaptation of the WICS code operational at the 12 ft pressure wind tunnel (12ft PWT) of NASA Ames Research Center (NASA ARC). This paper discusses the details of implementation of WICS at the NTF including tunnel calibration, code modifications for tunnel and support geometry, changes made for the NTF wall orifices layout, details of interfacing with the tunnel data processing system, and post-processing of results. Example results of applying WICS to a semispan test and a full span test are presented. Comparison with classical correction results and an analysis of uncertainty in the corrections are also given. As a special application of the code, the Mach number calibration data from a centerline pipe test was computed by WICS. Finally, future work for expanding the applicability of the code including online implementation is discussed.

Iyer, Venkit↗

Development and performance evaluation of active insulation systems using solid-state thermal switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs) that dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. However, materials and assembly development still need a cost-effective product that achieves the required performance. Here, in this study, we present the process of developing an AIS that we will install in a test hut for its performance evaluation. Minimum performance criteria of the AIS system are developed based on R-low/R-high ratio, required time and efficiency to switch states, and cost estimates. The following steps during this study are creating the concept to meet the requirements, predicting the performance via simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to environmental chamber tests. The selected approach uses off-the-shelf products to create an AIS that can switch R-value between 0.98 ft 2 ·°F·h/BTU (0.173 m 2 ·K/W) and 5.81 ft 2 ·°F·h/BTU (1.02 m 2 ·K/W) and have a switching time of less than one minute between R-high and R-low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Video System For Inspecting Walls Of Cavities

Endoscopic video-imaging system generates panoramic image of part of wall of cavity surrounding tip of probe inserted in cavity. Not necessary to rotate probe to obtain panoramic image. If simple inspection without measurement required, device called "cylindrical light ring" mounted on probe to illuminate scene. Different illumination device used when required to measure distance of wall of cavity from cylindrical axis of probe. System used, for example, to inspect inner surface of tube, passage, or manifold located deep within engine or other complex structure.

Gilbert, John A.↗

Re-design and fabrication of titanium multi-wall Thermal Protection System (TPS) test panels

The Titanium Multi-wall Thermal Protection System (TIPS) panel was re-designed to incorporate Ti-6-2-4-2 outer sheets for the hot surface, ninety degree side closures for ease of construction and through panel fastness for ease of panel removal. Thermal and structural tests were performed to verify the design. Twenty-five panels were fabricated and delivered to NASA for evaluation at Langley Research Center and Johnson Space Center.

Blair, W.↗

Effect of a crystal-melt interface on Taylor-vortex flow

The linear stability of circular Couette flow between concentric infinite cylinders is considered for the case that the stationary outer cylinder is a crystal-melt interface rather than a rigid surface. A radial temperature difference is maintained across the liquid gap, and equations for heat transport in the crystal and melt phases are included to extend the ordinary formulation of this problem. The stability of this two-phase system depends on the Prandtl number. For small Prandtl number the linear stability of the two-phase system is given by the classical results for a rigid-walled system. For increasing values of the Prandtl number, convective heat transport becomes significant and the system becomes increasingly less stable. Previous results in a narrow-gap approximation are extended to the case of a finite gap, and both axisymmetric and nonaxisymmetric disturbance modes are considered. The two-phase system becomes less stable as the finite gap tends to the narrow-gap limit. The two-phase system is more stable to nonaxisymmetric modes with azimuthal wavenumber n = 1; the stability of these n = 1 modes is sensitive to the latent heat of fusion.

Mcfadden, G. B.↗

Parameter Sensitivity Study of the Wall Interference Correction System (WICS)

An off-line version of the Wall Interference Correction System (WICS) has been implemented for the "NASA Langley National Transonic Facility. The correction capability is currently restricted to corrections for solid wall interference in the model pitch plane for Mach numbers, less than 0.45 due to a limitation in tunnel calibration data. A study to assess output sensitivity to the aerodynamic parameters of Reynolds number and Mach number was conducted on this code to further ensure quality during the correction process. In addition, this paper includes all investigation into possible correction due to a semispan test technique using a non metric standoff and all improvement to the standard data rejection algorithm.

Walker, Eric L.↗

Sensitivity Study of the Wall Interference Correction System (WICS) for Rectangular Tunnels

An off-line wall version of the Wall Interference Correction System (WICS) has been implemented for the NASA Langley National Transonic Facility. The correction capability is currently restricted to corrections for solid wall interference in the model pitch plane for MAch numbers less than 0.45 due to limitation in tunnel calibration data. A study to assess output sensitivity to measurement uncertainty was conducted to determine standard operational procedures and guidelines to ensure data quality during the testing process.

Walker, Eric L.↗

Earthquake-induced impact of base-isolated buildings: theory, numerical modeling, and design solutions

Earthquake shaking more intense than that used to size the horizontal clearance between a base–isolated building and near–rigid perimeter moat wall will result in hard impact, producing high–frequency, high–amplitude acceleration response in the structure and supported equipment. Herein this paper provides a design solution for the damaging effects of hard impact by installing a compliant engineered element in the load path between the base–isolated building and the moat wall, resulting in soft impact and a much smaller acceleration response. The engineered element assumed herein is a commercial–off–the–shelf marine fender with mechanical properties determined by physical testing. The attachment of a flexible engineered element, with well–defined stiffness and damping, to a near–rigid moat wall, simplifies the numerical modeling of the building–moat wall system and eliminates the need to bound the lateral stiffness of the wall for impact calculations. The simple model of the engineered element can be implemented in commercial finite element codes. Theory is developed for two–sided impact of a single–degree–of–freedom oscillator. Analytical solutions are derived for the shifted first–mode frequency of the impacted oscillator and for its free–vibration response. The shifted first–mode frequency is a function of the composite lateral stiffness of the isolator–engineered element assembly and its earthquake–induced displacement. Local peaks in the spectral response of the impacted oscillator form at odd integer multiples of the shifted first–mode frequency. The analytical solutions can be used to verify, in part, the numerical model used for impact analysis.

42 ENGINEERING↗

Do Flashing and Sealant Materials Need to be Exposed to Extreme Cycling?

In the U.S., over 50% of homes were built before 1980, when minimal building codes existed. The aging of building envelopes can significantly contribute to the air leakage, moisture intrusion, and durability of buildings leading to higher energy demands. Although the durability of building materials and envelope systems has been studied extensively, the durability of specific components like window-wall flashing and sealants remains underexplored. Current standards such as ASTM, NIST, and AAMA primarily focus on durability testing considering the high temperatures only and require sealant testing on anodized aluminum panels, leaving questions about performance in cold or fluctuating temperatures unanswered. Current ASTM and AAMA standards provide guidelines for durability testing but predominantly focus on exposure to higher temperature conditions. It remains unclear how exposure to cold temperatures, or cycles of both hot and cold conditions, affect the durability of these materials. Furthermore, AAMA standards mandate that flashing materials be tested on anodized aluminum panels, which may not reflect real-world applications. Therefore, this initial study aims to explore this concern through testing by constructing two window-wall interface prototypes and applying five different flashing and sealant materials to their joints. These samples were subjected to extreme temperatures, ranging from −34 ℃ (−30 °F) to 50 ℃ (122 °F), over a 28-day period (fourteen cycles of 24 hours), with daily visual inspections to document any signs of deterioration such as wrinkling, distortion, or warping. The study has two main objectives: (1) to determine whether flashing and sealant materials lose their durability and strength when exposed to varying climate conditions, specifically cold climates, and (2) to assess whether the interaction of these materials with different substrates (e.g., lumber, PVC, insulation) affects their durability and strength under varying climate conditions. The findings demonstrate how aging impacts the durability of window-wall systems interfaces, justifying future research that potentially could lead to the development of new testing protocols if significant defects are identified.

Palani, Hevar [ORNL] (ORCID:0000000220211994)↗