Search NASA⌕ Search

SEARCH · Search NASA

Results for “water end-use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

47 records · Page 3

Filtering Water by Use of Ultrasonically Vibrated Nanotubes

Devices that could be characterized as acoustically driven molecular sieves have been proposed for filtering water to remove all biological contaminants and all molecules larger than water molecules. Originally intended for purifying wastewater for reuse aboard spacecraft, these devices could also be attractive for use on Earth in numerous settings in which there are requirements to obtain potable, medical-grade, or otherwise pure water from contaminated water supplies. These devices could also serve as efficient means of removing some or all water from chemical products . for example, they might be useful as adjuncts or substitutes for stills in the removal of water from alcohols and alcoholic beverages. These devices may be constructed using various materials, such as ceramics, metallics, or polymers, depending on end-use requirements. A representative device of this type (see figure) would include a polymeric disk, about 1 mm in diameter and between 1 and 40 microns thick, within which would be embedded single-wall carbon nanotubes aligned along the thickness axis. The polymeric disk would be part of a unitary polymeric ring assembly. An acoustic transducer in the form of a piezoelectric-film-and-electrode subassembly - typically 9 microns thick and made of poly(vinylidene fluoride) coated with copper 150 nm thick -. would be affixed to the outside of the outer polymeric ring by means of an electrically nonconductive epoxy. The nanotubes would be chosen to have diameters between about 8 and about 13.5 A because water molecules could fit into the nanotubes, but larger molecules could not. Water to be purified would be placed in contact with one face (typically, the upper face) of the filter disk. The surface tension of water is low enough that water molecules should enter and travel along the nanotubes, and computational simulations of molecular dynamics and experimental measurements have shown that the water molecules inside the nanotubes in this size range can be expected to become aligned into helical columns that exhibit properties of both hexagonal ice crystals and liquid water

Gavalas, Lillian Susan↗

Stochastic simulation of occupant-driven energy use in a bottom-up residential building stock model

The residential buildings sector is one of the largest electricity consumers worldwide and contributes disproportionally to peak electricity demand in many regions. Strongly driven by occupant activities, household energy consumption is stochastic and heterogeneous in nature. However, most residential energy models applied by industry use homogeneous, deterministic activity schedules, which work well for predictions of annual energy consumption, but can result in unrealistic hourly or sub-hourly electric load profiles, with exaggerated or muted peaks. The increasing proportion of variable renewable energy generators means that representing the heterogeneity and stochasticity of occupant behavior is now crucial for reliable planning at both bulk-power and distribution-system scales. This work presents a novel and open-source occupancy simulation approach that can simulate a diverse set of individual occupant and household event schedules for all major electricity, fuel, and hot water end uses. To accomplish this, we evaluated three alternative occupant activity simulation approaches before selecting a hybrid combining time-inhomogeneous Markov chains and probability-sampling of event durations and magnitudes. Further, we integrated the stochastic occupancy simulation with an open-source bottom-up physics-simulation building stock model and published a set of 550,000 diverse household end-use activity schedules representing a national housing stock. The simulator was verified against time-use survey data, and simulation results were validated against measured end-use electricity data for accuracy and reliability. While we use data for the United States, our application demonstrates how similar approaches could be applied using the time-use survey data collected in many countries around the world.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Household energy resilience in extreme weather events: An investigation of energy service importance, HVAC usage behaviors, and willingness to pay

Household energy resilience, particularly maintaining essential energy services within an acceptable and affordable level, is critical during extreme weather events (e.g., winter storms, heat waves) with power shortages or outages. However, the research on the importance and acceptable compromise levels of energy services, HVAC usage behavior changes, and willingness to pay (WTP) for energy services during disasters is limited. Therefore, this study investigates the importance and compromise of household energy services, HVAC usage behaviors, and WTP, as three key dimensions of household energy resilience, in both normal days and disaster scenarios through surveys (n=485). First, 12 common residential end-uses are grouped into high, mid, and low-priority services using hierarchical clustering, in which high-priority services (perceived as important and un-compromisable) include food cooking and storage (refrigerator and freezer) and thermal comfort (space heating and cooling), mid-priority services involve water heating and lighting, while low-priority services are mostly related to entertainment and housework (e.g., TV, laundry). Also, HVAC use patterns demonstrate that occupants become more energy conservative during disasters, e.g., reducing durations of running HVAC and adjusting temperature setpoints to save energy. In terms of energy cost, approximately 60% of respondents are willing to pay more to maintain energy services during disasters, although only 13% are prepared to pay over double the normal energy prices. The regression models further reveal that household energy resilience varies across different sociodemographic groups (e.g., age, income, family size) and is impacted by disaster experience and beliefs in clean energy and climate. In conclusion, these research findings provide important perspectives to understand household energy resilience and inform measures for disaster adaptation of households in extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing mixed cool thermal storage systems across a connected community

A high level of electric demand flexibility must be integrated into our building infrastructure to enable greater renewable energy penetration in the grid. In the U.S., 9% of electricity generated is used to cool buildings in a periodic manner, making this end-use an ideal target for active management through cool thermal energy storage (CTES) technologies. Historic uses for CTES are designed around central chilled water plants, but these systems cool less than 25% of U.S. commercial floorspace. Emerging technologies are under development to serve the many smaller distributed cooling systems, such as rooftop units (RTUs), and have the potential to add CTES to an additional 66% of cooled commercial floorspace. However, these unitary thermal storage systems (UTSS) lack the modeling and analysis tools to evaluate them in the future interactive grid context. Here, this study develops the modeling and optimization tools necessary to simultaneously examine central and distributed ice storage systems within the multi-building, connected community context. An integrated simulation-optimization workflow is created to allow for rapid customized analysis. Results demonstrate the energy and flexibility tradeoffs of various implementations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-economic and life cycle analysis of synthetic natural gas production from low-carbon H 2 and point-source or atmospheric CO 2 in the United States

Synthetic natural gas (SNG) is of great interest in reducing fossil energy consumption while maintaining compatibility with existing NG infrastructure and end-use applications equipment. SNG can be produced using clean H 2 generated from renewable or nuclear energy and CO 2 captured from stationary sources or the atmosphere. In this study, we develop an engineering process model of SNG production using Aspen Plus® and production scales reported by the industry. We examine the levelized cost and life cycle greenhouse gas (GHG) emissions of SNG production under various CO 2 supply scenarios. Considering the higher cost of H 2 transportation compared with CO 2 transportation, we assume that CO 2 feedstock is transported via pipeline to the H 2 production location, which is collocated with the SNG plant. We also evaluate the cost of CO 2 captured from the atmosphere, assuming the direct air capture process can occur near the SNG facility. Depending on the CO 2 supply chain, the levelized cost of SNG is estimated to be in the range of $\$45–76$ per million British thermal units (MMBtu) on a higher heating value (HHV) basis. The SNG production cost may be reduced to $\$27–57$/MMBtu-HHV by applying a tax credit available in the United States for low-carbon H 2 production (45V). With a lower electricity price of 3¢/kWh for water electrolysis and accounting for a 45V tax credit, the SNG cost reaches parity with the cost of fossil NG. Depending on the CO 2 supply chain, SNG can reduce life cycle GHG emissions by 52–88% compared with fossil NG.

03 NATURAL GAS↗

Design, modeling and simulation of nuclear-powered integrated energy systems with cascaded heating applications

Nuclear-renewable integrated energy systems (IES) consist of a variety of energy generation and conversion technologies and can be used to meet heterogeneous end uses (e.g., electricity, heat, and cooling demands). In addition to supply-demand balance, end-use heat demands usually require heat supply of certain temperature ranges. The effective and efficient utilization of heat produced within an IES is, therefore, a critical challenge. Here, this paper examines design options of an IES that includes heating processes of multiple temperature grades. We investigate a cascaded design configuration, where the remaining residual heat after high-grade heating processes [e.g., hydrogen production through high-temperature steam electrolysis (HTSE)] is recovered to meet the low-grade heating needs [e.g., district heating (DH)]. Additionally, a thermal energy storage system is integrated into the DH system to address the imbalance between heat supply and demand. This paper primarily focuses on the design and modeling of the proposed system and evaluates its operation with a 24-h transient process simulation using a DH demand profile with hourly resolution. The results indicate that the residual heat from the HTSE exhaust is insufficient for the DH demand, and additional topping heat directly from the reactor process steam is needed. Furthermore, the inclusion of thermal energy storage within the DH system provides the necessary balance between thermal generation and demand, thereby ensuring a consistent rated temperature of the DH supply water. This approach helps minimize the control actions needed on the reactor side.

08 HYDROGEN↗

Analysis of Space-Conditioning Loads in Commercial Buildings

Space conditioning end-uses, which include heating, cooling, and ventilation, represent a significant fraction of commercial building energy use, with a wide variety of heating and cooling technology options available in the market. In the interest of improving the overall efficiency of heating, ventilation and air-conditioning (HVAC) technologies, governments, utilities and private sector entities have implemented a variety of market transformation policies that aim to influence consumer purchase decisions. To evaluate the costs and benefits of such programs, analysts typically postulate a hypothetical default equipment choice, and compare it to one that provides comparable service with lower energy and/or power use. The corresponding reduced operating cost provides a benefit that offsets the potential higher cost of improved efficiency. Typically, life-cycle cost or cash-flow analyses are used to quantify the net economic benefit. These analyses require the capability to assess how a given equipment design would perform across a broad range of characteristics, both of the building and of the local weather. While these assessments can be performed using customized building simulations, it is generally not practical to develop and validate detailed building simulation code to cover all the potential variations of equipment design and installation. An alternative, and somewhat simpler, approach is to solely use detailed building simulations to generate time series of heating and cooling loads in commercial buildings. These loads can then be used as input to more detailed, stand-alone engineering models that simulate HVAC system performance under different equipment designs. This approach was used to evaluate a range of high-efficiency commercial packaged air conditioner design options for the Department of Energy’s Appliance and Equipment Standards Program (DOE-EERE 2015). While there may be some loss of precision relative to full simulation, the accuracy of this approach is sufficient for practical applications of cost-benefit analysis. This report describes the development of a database of commercial building heating and cooling loads, generated using the EnergyPlus software package, a whole building energy use model supported by the Department of Energy (DOE-EERE 2020a). EnergyPlus takes as input a set of configuration files that describe the building itself (size, zoning, envelope characteristics, etc.) and the various systems within it (HVAC, lighting, water heating, etc.). This analysis uses a publicly available collection of commercial reference buildings (CRB), comprised of sixteen building types and three vintages (DOE-EERE 2020b; Deru et al 2011). Each building is simulated in eighteen different locations, covering a wide range of climatic conditions. The prototype building description files assign the type of HVAC equipment used, and capacities across climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economic Analysis of Lithium Extraction from Geothermal Brines

The United States has a large, domestic source of lithium in geothermal fluids, especially at the Salton Sea region of southern California, where estimates of lithium pass-through at geothermal plants exceed 24,000 metric tons per year, based on 2019 geothermal plant operations. Lithium extraction from geothermal brines offers the potential to provide the United States with a secure, domestic supply of lithium to meet the increasing demands of electric vehicles, grid energy storage, portable electronics, and other end-use applications. Additionally, the use of direct extraction technologies allows for a more sustainable lithium supply relative to current evaporative brine and hardrock mining operations in terms of land use, water use, time to market with lithium products, and carbon intensity of operations. This report is part of an effort to assess geothermal brines as a source of commercial lithium supply for the United States. In this study, the National Renewable Energy Laboratory (NREL) reviews and summarizes public technoeconomic analyses of lithium extraction technologies. The work was coordinated with the Critical Minerals Institute at the Colorado School of Mines who focused on supply chain analysis of lithium.

15 GEOTHERMAL ENERGY↗

ComStock Measure Scenario Documentation: Chiller Replacement

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at a subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations. This report describes the modeling methodology for a single end-use savings shape measure - chiller replacement - and briefly introduces key results. The full public dataset can be accessed on the ComStock (TM) data lake or via the Data Viewer at comstock.nrel.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Production of Renewable Natural Gas from Waste Carbon Dioxide Sources (CRADA Final Report)

This CRADA provides new funding from SoCalGas and DOE's BETO and FCTO Offices focused hydrogen mass transfer limitations in H2@Scale processes. The project leverages the existing hydrogen production capabilities at the Energy Systems Integration Facility (ESIF) and SoCalGas' 700 L bioreactor system designed, built, and delivered to NLR under the first phase of this CRADA. This Joint Work Statement will cover new hardware modifications between NLR's electorlyzer stack and the SoCalGas bioreactor located outdoors. The new hardware and controls will provide researchers with the tools needed to obtain preliminary experimental data for a non-provisional application due in July 2019. The IP being developed is expected to improve the productivity of the bioreactor and would have wider impacts on other end-use processes using pressurized hydrogen (H2). In addition, this new funding enhances an existing BETO Biopower award by developing a 10-15 kW electrolyzer that is scalable to the MW-class with reduced capital cost and higher efficiency aimed at improving H2 mass transfer to downstream processes, like biomethanation. Finally due to the close-coupling between the electrolyzer stack and bioreactor, R&D will focus on cell retention, nutrient maintenance, optimal water management and process controls.

08 HYDROGEN↗

The Modeling of the Synfuel Production Process: Process models of Fischer-Tropsch production with electricity and hydrogen provided by various scales of nuclear plants

Synthetic fuels (synfuels), also known as electro-fuels (E-fuels), are hydrocarbon fuels produced from waste CO2 streams and water electrolysis, with electricity as the primary source of energy. To achieve substantial reductions in greenhouse gas (GHG) emissions, electricity sources must release zero carbon or near-zero carbon, as is the case with solar, wind, hydro, and nuclear power. Nuclear power is one of the largest and steadiest domestic sources of clean energy in the United States. Moreover, nuclear power has the potential to produce hydrogen economically for less than $2/kg, reaching the DOE near-term target price. Thus, using nuclear power to produce synfuels has the unique potential to significantly reduce the GHG emissions of hydrocarbon fuels production and end-use applications. Fisher-Tropsch or FT fuel (a mixture of naphtha, jet fuel, and diesel) is of great interest because it is a drop-in fuel that can be blended with conventional petroleum counterparts and is compatible with existing infrastructure. By using the ASPEN Plus model, this report develops FT fuel production models on three scales, corresponding to nuclear plants with capacities of 1000 MWe, 437 Mwe, and 100 MWe, respectively. The FT model case with energy from a 437-MWe nuclear plant is used as a baseline case. This report summarizes the baseline ASPEN Plus model results with a detailed mass and energy analysis. Our modeled facility produces 507 MT/day (185,000 gal/day) of FT fuel by converting 255 MT/day of hydrogen and 1,580 MT/day of CO2. The FT fuel production energy efficiency from hydrogen and electricity energy inputs is 70% (lowerheating-value or LHV-based). Including the high-temperature electrolyzer in the system boundary, the FT fuel production LHV efficiency from electricity and thermal energy inputs is 51%, considering 39.8 kWh/kg of electricity and 6.86 kWh/kg of thermal energy use from a nuclear plant for hydrogen production. The FT production efficiency can potentially be increased by further integrating the heat exchange between nuclear plant and FT process, and this study is underway. The carbon conversion ratio in the baseline case is 99%, with process CO2 capture and recirculation and oxy-combustion using the oxygen by-product from water electrolysis. The hydrogen consumption is 1.38 kg/gal-FT fuel and the CO2 consumption is 8.56 kg/gal-FT fuel in the baseline case. With different FT production scales determined by the nuclear plant capacity, the FT model was scaled using the same operating parameters, which led to the same conversion efficiency regardless of scale. However, the different FT plant scales will impact the economics of FT fuel production; this impact will be examined in the next phase of this study.

Zang, Guiyan↗