Search NASA⌕ Search

SEARCH · Search NASA

Results for “water sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Estimating Major Ion and Nutrient Concentrations in Mangrove Estuaries in Everglades National Park Using Leaf and Satellite Reflectance

Coastal mangrove ecosystems are under duress worldwide because of urban development, sea-level rise, and climate change, processes that are capable of changing the salinity and nutrient concentration of the water utilized by the mangroves. This study correlates long-term water chemistry in mangrove environments, located in Everglades National Park,with mangrove spectral reflectance measurements made at both the leaf and canopy scales. Spectral reflectance measurements were collected using a handheld spectrometer for leaf-level measurements and Landsat 5TMdata for regional coverage. Leaf-level reflectance data were collected from three mangrove species (i.e., red, black and white mangroves) across two regions; a tall mangrove (approximately 18m) and dwarf mangrove (1- 2 m) region. The reflectance data were then used to calculate a wide variety of biophysical reflectance indices (e.g., NDVI, EVI, SAVI) to determine signs of stress. Discrete, quarterly water samples from the surface water, groundwater, and pore water (20 and 85 cm depths) and daily autonomous surface water samples were collected at each site and analyzed for major anions (Cl(−) and SO(2(-)/4)), cations (Na(+), K(+), Mg(sup 2(+)), and Ca(sup 2(+)), total nitrogen (TN) and total phosphorus (TP).Mangrove sites that exhibited the highest salinity and ionic concentrations in the surface and subsurface water also had the lowest near-infrared reflectance at both the leaf and satellite levels. Seasonal reflectance responses were measured in the near-infrared (NIR) wavelengths at both the leaf and canopy scales and were strongly correlated with nutrient and ionic concentrations in the surface and subsurface water, even though there was no significant separability between the three mangrove species. Study sites that experienced the greatest variability in surface and subsurface water ionic concentrations also exhibited the greatest fluctuations in NIR spectral reflectance. Landsat 5TM images were able to detect tall and dwarf mangroves by the differences in spectral indices (e.g., NDVI, NDWI, and EVI) because of the variability in the background conditions amongst the environments. In addition, Landsat 5TM images spanning 16 years (1993- 2009) were successfully used to estimate the seasonal variability in ionic concentrations in the surface water across the Florida Coastal mangrove ecotone. This study has shown that water chemistry can be estimated indirectly by measuring the change in spectral response at the leaf- or satellite-scale. Furthermore, the results of this research may be extrapolated to similar coastal mangrove systems throughout the Caribbean and world-wide wherever red, black, and white mangroves occur.

Mangroves↗

Characterization of C-Reactor (105-C) Moderator Tanks 204 and 205

Area Completion Project (ACP)/Savannah River Nuclear Solutions (SRNS) has requested Savannah River National Laboratory (SRNL) to perform chemical and radiological analyses on moderator heavy water samples from C-Reactor (105-C) in Moderator Tanks 204 and 205. The heavy water samples have been characterized using SRNL analytical methods. Information generated from the characterization of these heavy water samples provide a basis for determining the residual contamination remaining in the tanks. These analyses are needed in order to update the C-Reactor Contaminant migration groundwater model and report, to help determine a disposition pathway for the moderator water, and to ship samples off-site to the Southwest Research Institute (SWRI). This report presents characterization results for the March 2024 C-Reactor Moderator Tank 204 and 205 heavy water samples. SRNL results are critical to allow ACP to complete this Performance Based Incentive project on time. Based on the characterization data provided in this report, results of these samples meet customer expectations and satisfy the Technical Assistance Request (TAR).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Precision cleaning verification of fluid components by air/water impingement and total carbon analysis

NASA personnel at Kennedy Space Center's Material Science Laboratory have developed new environmentally sound precision cleaning and verification techniques for systems and components found at the center. This technology is required to replace existing methods traditionally employing CFC-113. The new patent-pending technique of precision cleaning verification is for large components of cryogenic fluid systems. These are stainless steel, sand cast valve bodies with internal surface areas ranging from 0.2 to 0.9 sq m. Extrapolation of this technique to components of even larger sizes (by orders of magnitude) is planned. Currently, the verification process is completely manual. In the new technique, a high velocity, low volume water stream impacts the part to be verified. This process is referred to as Breathing Air/Water Impingement and forms the basis for the Impingement Verification System (IVS). The system is unique in that a gas stream is used to accelerate the water droplets to high speeds. Water is injected into the gas stream in a small, continuous amount. The air/water mixture is then passed through a converging/diverging nozzle where the gas is accelerated to supersonic velocities. These droplets impart sufficient energy to the precision cleaned surface to place non-volatile residue (NVR) contaminants into suspension in the water. The sample water is collected and its NVR level is determined by total organic carbon (TOC) analysis at 880 C. The TOC, in ppm carbon, is used to establish the NVR level. A correlation between the present gravimetric CFC113 NVR and the IVS NVR is found from experimental sensitivity factors measured for various contaminants. The sensitivity has the units of ppm of carbon per mg/sq ft of contaminant. In this paper, the equipment is described and data are presented showing the development of the sensitivity factors from a test set including four NVRs impinged from witness plates of 0.05 to 0.75 sq m.

Barile, Ronald G.↗

Precision Cleaning Verification of Fluid Components by Air/Water Impingement and Total Carbon Analysis

NASA personnel at Kennedy Space Center's Material Science Laboratory have developed new environmentally sound precision cleaning and verification techniques for systems and components found at the center. This technology is required to replace existing methods traditionally employing CFC-113. The new patent-pending technique of precision cleaning verification is for large components of cryogenic fluid systems. These are stainless steel, sand cast valve bodies with internal surface areas ranging from 0.2 to 0.9 m(exp 2). Extrapolation of this technique to components of even larger sizes (by orders of magnitude) is planned. Currently, the verification process is completely manual. In the new technique, a high velocity, low volume water stream impacts the part to be verified. This process is referred to as Breathing Air/Water Impingement and forms the basis for the Impingement Verification System (IVS). The system is unique in that a gas stream is used to accelerate the water droplets to high speeds. Water is injected into the gas stream in a small, continuous amount. The air/water mixture is then passed through a converging-diverging nozzle where the gas is accelerated to supersonic velocities. These droplets impart sufficient energy to the precision cleaned surface to place non-volatile residue (NVR) contaminants into suspension in the water. The sample water is collected and its NVR level is determined by total organic carbon (TOC) analysis at 880 C. The TOC, in ppm carbon, is used to establish the NVR level. A correlation between the present gravimetric CFC-113 NVR and the IVS NVR is found from experimental sensitivity factors measured for various contaminants. The sensitivity has the units of ppm of carbon per mg-ft(exp 2) of contaminant. In this paper, the equipment is described and data are presented showing the development of the sensitivity factors from a test set including four NVR's impinged from witness plates of 0.05 to 0.75 m(exp 2).

Barile, Ronald G.↗

Water Analysis of the Heat Melt Compactor

The Heat Melt Compactor (HMC) recovers water from trash at low temperatures and under vacuum conditions to obtain relatively cleaner water with less contaminants. The effluent water vapor is condensed and collected for analysis. The objectives of the analysis are to identify chemical components in the water sample, evaluate water quality, and assess the compatibility of the liquid effluent with the International Space Station (ISS) water systems. The evaluation of water quality includes total organic carbon (TOC) concentrations which provide a general indication of overall water quality, other defining characteristics such as pH and conductivity, and comparison with previous ISS water analytical data as a baseline for the evaluation.

trash↗

The correlation and quantification of airborne spectroradiometer data to turbidity measurements at Lake Powell, Utah

A water sampling program was accomplished at Lake Powell, Utah, during June 1975 for correlation to multispectral data obtained with a 500-channel airborne spectroradiometer. Field measurements were taken of percentage of light transmittance, surface temperature, pH and Secchi disk depth. Percentage of light transmittance was also measured in the laboratory for the water samples. Analyses of electron micrographs and suspended sediment concentration data for four water samples located at Hite Bridge, Mile 168, Mile 150 and Bullfrog Bay indicated differences in the composition and concentration of the particulate matter. Airborne spectroradiometer multispectral data were analyzed for the four sampling locations. The results showed that: (1) as the percentage of light transmittance of the water samples decreased, the reflected radiance increased; and (2) as the suspended sediment concentration (mg/l) increased, the reflected radiance increased in the 1-80 mg/l range. In conclusion, valuable qualitative information was obtained on surface turbidity for the Lake Powell water spectra. Also, the reflected radiance measured at a wavelength of 0.58 micron was directly correlated to the suspended sediment concentration.

Merry, C. J.↗

An ICP-OES method for the precise and accurate quantification of rare earth elements in natural water: A comparative study from mine waste sites in New Mexico, USA

Inductively coupled plasma techniques such as ICP-OES and ICP-MS are routinely used to determine the concentrations of rare earth elements (REE) in water samples. However, their performance for the determination of REE concentration in mine drainage waters from epithermal vein and porphyry copper mining districts has not been evaluated extensively. In this work, we develop an REE analysis method on an Agilent 5900 ICP-OES instrument and assess the accuracy and precision for the quantification of REE in the natural waters collected from mine adits and an acid seep of mine sites in the Steeple Rock and Hillsboro mining districts, New Mexico, USA. The total REE concentrations in the water samples were measured using the methods we developed for both ICP-OES and ICP-MS. The power of the new ICP-OES method lies in routine analysis of μg/L level concentrations normally analyzed using ICP-MS, including a U.S. Geological Survey standard reference sample, laboratory blank samples spiked with a National Institute of Standards and Technology traceable standard, and surface water samples from mine waste sites. This ICP-OES method achieves low quantification limits ranging from 0.2 to 5 μg/L and excellent analytical accuracy and precision for REE analysis. The precision of light (La-Gd) and heavy (Tb-Lu) REE analysis using this method are better than 5% at average concentrations above 5 ± 4 μg/L and 3 ± 2 μg/L, respectively, and 3% at average concentrations above 10 ± 9 μg/L and 5 ± 4 μg/L, respectively. This method also shows excellent sensitivity and reproducibility for our laboratory and field samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geochemistry, volumetric water content, and active layer depths from rainfall simulations at the Kougarok Fire Site, Seward Peninsula, Alaska, 2022

Rainfall frequency and intensity is expected to increase in the Arctic, with potential implications for permafrost thaw and geochemical fluxes in soils. To conduct controlled rainfall experiments at remote field sites in the Arctic, the Next-Generation Ecosystem Experiments Arctic Rainfall Simulator (NARS) was developed at Los Alamos National Laboratory as part of the NGEE Arctic project. To better understand how rainfall may affect interflow biogeochemistry and permafrost thaw, rainfall simulations were performed on the Seward Peninsula of Alaska during late September and early October 2022 at the Kougarok Fire Site near mile marker 86 of the Nome-Taylor Highway. Water samples were collected before, during, and after rainfall simulations until interflow had ceased. Additional data collected included soil pore water samples from macrorhizons, active layer depths, and volumetric water content at each of the experimental plots. This dataset contains one *.csv file of water sample properties, one *.csv file of thaw depths, one *.csv file of soil moisture measurements, and one *.kml file of the locations where samples were collected.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy’s Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy’s Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

ESS-DIVE Reporting Format for Sample-based Water and Soil Chemistry Measurements

The ESS-DIVE (Environmental Systems Science Data Infrastructure for a Virtual Ecosystem) reporting format for sample-based water and soil chemistry measurements are written guidelines and spreadsheet templates, that facilitate archiving water/soil/sediment chemistry data. The templates and terminology lists provided as part of the reporting format can help organize data and potentially enable data reuse.The reporting format consists of a general instructions file (instructions.md) as well as more detailed instructions files for each template (files beginning “Detailed_Instructions_*.md). The “examples” folder includes an example of each data template with just the limited set of required fields filled out as well as other examples with both required and optional fields complete.The 'templates' folder contains CSV templates for data, methods, and terminology file templates. Similar to the examples folder, the blank templates are provided with versions for required fields only as well as required and optional fields. Lastly, the term list folder provides common terminology used in each of the templates as well as a definition and any constraints for the fields.

54 ENVIRONMENTAL SCIENCES↗

Lake Superior water quality near Duluth from analysis of aerial photos and ERTS imagery

ERTS imagery of Lake Superior in the late summer of 1972 shows dirty water near the city of Duluth. Water samples and simultaneous photographs were taken on three separate days following a heavy storm which caused muddy runoff water. The water samples were analyzed for turbidity, color, and solids. Reflectance and transmittance characteristics of the water samples were determined with a spectrophotometer apparatus. This same apparatus attached to a microdensitometer was used to analyze the photographs for the approximate colors or wavelengths of reflected energy that caused the exposure. Although other parameters do correlate for any one particular day, it is only the water quality parameter of turbidity that correlates with the aerial imagery on all days, as the character of the dirty water changes due to settling and mixing.

Scherz, J. P.↗

ISS Potable Water Quality for Expeditions 26 through 30

International Space Station (ISS) Expeditions 26-30 spanned a 16-month period beginning in November of 2010 wherein the final 3 flights of the Space Shuttle program finished ISS construction and delivered supplies to support the post-shuttle era of station operations. Expedition crews relied on several sources of potable water during this period, including water recovered from urine distillate and humidity condensate by the U.S. water processor, water regenerated from humidity condensate by the Russian water recovery system, and Russian ground-supplied potable water. Potable water samples collected during Expeditions 26-30 were returned on Shuttle flights STS-133 (ULF5), STS-134 (ULF6), and STS-135 (ULF7), as well as Soyuz flights 24-27. The chemical quality of the ISS potable water supplies continued to be verified by the Johnson Space Center s Water and Food Analytical Laboratory (WAFAL) via analyses of returned water samples. This paper presents the chemical analysis results for water samples returned from Expeditions 26-30 and discusses their compliance with ISS potable water standards. The presence or absence of dimethylsilanediol (DMSD) is specifically addressed, since DMSD was identified as the primary cause of the temporary rise and fall in total organic carbon of the U.S. product water that occurred in the summer of 2010.

Straub, John E., II↗

Data for Kim et al., "Variations in the optical and molecular composition of dissolved organic matter exported from coastal wetlands"

Knowledge about sources and composition of marsh-derived dissolved organic matter (DOM) is critical for understanding the role of marshes in coastal biogeochemical cycling and the fate of marsh-derived DOM in the ocean. To investigate tidal variability in composition of marsh-derived DOM, Kim et al. examined the optical and molecular characteristics of hourly surface water samples at three tidal creeks in the Chesapeake Bay. Groundwater samples along the terrestrial landscape gradient as well as estuarine water from the adjacent estuary at each site were also collected to help resolve sources of surface water DOM. Samples were collected in summer 2024 at three sites – SWH: Sweet Hall Marsh, GCW: Kirkpatrick Marsh, and GWI: Goodwin Islands – which are part of synoptic sites in the Chesapeake Bay region of the COMPASS-FME (Coastal Observations, Mechanisms, and Predictions Across Systems and Scales - Field, Measurements, and Experiments) project. Surface water samples were collected hourly over a 48-hour period at each site. Groundwater and estuarine water samples were collected once. This dataset includes- Surface water depth and salinity- Dissolved organic carbon (DOC) and total dissolved nitrogen (TDN) concentrations- Optical indices and relative composition of parallel factor analysis (PARAFAC) components- High resolution mass spectrometry data.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Microbial Communities as Indicators of Microbially Induced Corrosion Potential in Stainless Steel Piping

The 200 West Area Pump-and-Treat (200W P&T) facility is part of the final remedy decision for the 200 ZP-1 Operable Unit (OU) and is the interim remedial action for 200-UP-1 OU at the Hanford Site. The facility also treats water from other sources across the site, including 200-DV-1 OU perched water, groundwater from the 200-BP-5 OU, and leachate from the Environmental Restoration Disposal Facility. The facility originally operated a biological treatment process for nitrate that resulted in systemic biofouling and loss of injection well capacity, requiring frequent and costly well rehabilitation. Biofouling has also contributed to corrosion of welds and pitting of stainless-steel piping at the facility. The biological treatment for nitrate was suspended at the end of 2019 calendar year to eliminate negative impacts from biological treatments which improve facility operations and treatment of carbon tetrachloride. Evaluation of the 200W P&T facility’s response to operational improvements, specifically the suspension of the biological treatment, provides information on the potential for continued microbially induced corrosion (MIC). To this end, historical data sets (2015-2017) were compared with molecular biological analyses of 200W P&T water samples from 2018-2020 to quantify trends in total microbial biomass and specific microbial indicator species (iron, sulfate, nitrate, and manganese reducing bacteria) known to cause and enhance metal corrosion. Results showed unequivocal reductions (in excess of 90%) in all microbiological indicators measured following the suspension of the biological treatment. Although abundance measurements for all corrosive MIC populations initially declined after removal of the treatment system, nitrate-reducing bacteria (nirK) and sulfate-reducing bacteria remain highly abundant in the system, an order of magnitude higher than the number of cells present prior to the removal of the biological treatment system [5.14e (1.4) cells/L, vs. 1.14e (0.07) cells/L, reported as average (±SD) for n=3]. In addition, there was an unexpected inflection point in 2019 where all microbial indicators increased unexpectedly in abundance in 2020 by as much as two orders of magnitude compared to 2019 samples. Given the limited number of water samples available for this analysis, the cause of the increase in microbial indicators post-biological treatment has not yet been determined. Systematic sampling of the facility for continued monitoring is recommended so that the responses of MIC populations can be evaluated to ensure that further corrosion is avoided, allowing the 200W P&T facility to operate safely and efficiently at design capacity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of microplastics in bivalves along Fourmile Branch

Microplastics are commonly found near wastewater treatment facilities with the source originating typically from fibers associated with laundry detergents. Fourmile branch would have limited laundry associated effluent and does not receive any input from water originating from upstream industry sources, therefore microplastics would have originated from Site operations or through atmospheric deposition which are both unexplored pathways. In order to assess environmental inventory effects on the biota, water samples were collected from sampling locations along Fourmile Branch on the Savannah River Site using plankton nets and grab samples at Fourmile Branch locations (i.e., FM-2B, FM-A7, and FM6). Fourmile Branch has a long history of receiving industrial effluents from site operations as well effluent from the site’s wastewater treatment plant. Water samples and the debris collected in the nets were rinsed with deionized water and sieved to remove the larger fractions of plastics (4000-2000 µm) and retain fractions <500 µm. The water samples were analyzed for the type and size of plastics by μ-Raman, mass spectrometry, and Fourier Transform Infrared Spectroscopy (FTIR) methods. Previously collected bivalves were prepared into thin sections and analyzed using microscopy.

54 ENVIRONMENTAL SCIENCES↗

Examination of coal combustion management sites for microbiological and chemical signatures of groundwater impacts

Coal combustion accounts for 40% of the world’s electricity and generates more than a billion tons of coal combustion products (CCP) annually, half of which end up in landfills and impoundments. CCP contain mixtures of chemicals that can be mobile in the environment and impact the quality of surface water and potable groundwater. In this investigation, water samples from 14 coal combustion management sites across 4 physiographic regions in the United States, paired with background and down-gradient groundwater samples, were analyzed for water chemistry and microbiology. The objective was to determine if microbiology data alone, or supported by chemistry data, could reliably differentiate source waters and identify sites where CCP is known or expected to be influencing groundwater. Two percent of the total amplicons showed genus level conservation across CCP management sites, regions, and sample types; corresponding to ubiquitous, facultatively aerobic proteobacterial taxa that are generally recognized for the potential to respire using different terminal electron acceptors. Ordination plots did not reveal significant differences ( p > 0.05) in 16S rRNA gene amplicon diversity by CCP management site, water sample types, or physiographic regions. Contrastingly, chemistry distinguished sample types by standard water quality metrics (total dissolved solids, Ca:SO 4 ratio), alkali earth metals (K, Na, Li), selenium, boron, and fluoride. A focused evaluation of 16S rRNA gene amplicons for a subset of CCP management sites revealed microbiological features and chemical drivers (F, Ca, temperature) that positively identified the single CCP management site confirmed to have groundwater impacted by CCP leachate. At this site, 9 genera (>0.5% relative abundance) were exclusive to CCP porewater and downgradient groundwater. Inferred metabolisms for these taxa indicates potential for N and S biogeochemical transformations and 1-C metabolism that are consistent with a reducing environment, as evidenced by low ORP and depleted SO 4 2− . This research contributes to a growing understanding of conditions where these data types, analyses, and interpretation methods could be applied for distinguishing influence from CCP on the surrounding environment, as well as practical limitations.

01 COAL, LIGNITE, AND PEAT↗

Chemical Analysis Results for Potable Water from ISS Expeditions 21 Through 25

The Johnson Space Center Water and Food Analytical Laboratory (WAFAL) performed detailed ground-based analyses of archival water samples for verification of the chemical quality of the International Space Station (ISS) potable water supplies for Expeditions 21 through 25. Over a 14-month period the Space Shuttle visited the ISS on four occasions to complete construction and deliver supplies. The onboard supplies of potable water available for consumption by the Expeditions 21 to 25 crews consisted of Russian ground-supplied potable water, Russian potable water regenerated from humidity condensate, and US potable water recovered from urine distillate and condensate. Chemical archival water samples that were collected with U.S. hardware during Expeditions 21 to 25 were returned on Shuttle flights STS-129 (ULF3), STS-130 (20A), STS-131 (19A), and STS-132 (ULF4), as well as on Soyuz flights 19-23. This paper reports the analytical results for these returned potable water archival samples and their compliance with ISS water quality standards.

Straub, John E., II↗

Effect of bolus fluid intake on energy expenditure values as determined by the doubly labeled water method

The doubly labeled water (DLW, 2H(2)18O) method is a highly accurate method for measuring energy expenditure (EE). A possible source of error is bolus fluid intake before body water sampling. If there is bolus fluid intake immediately before body water sampling, the saliva may reflect the ingested water disproportionately, because the ingested water may not have had time to mix fully with the body water pool. To ascertain the magnitude of this problem, EE was measured over a 5-day period by the DLW method. Six subjects were dosed with 2H2(18)O. After the reference salivas for the two-point determination were obtained, subjects drank water (700-1,000 ml), and serial saliva samples were collected for the next 3 h. Expressing the postbolus saliva enrichments as a percentage of the prebolus value, we found 1) a minimum in the saliva isotopic enrichments were reached at approximately 30 min with the minimum for 2H (95.48 +/- 0.43%) being significantly lower than the minimum for 18O (97.55 +/- 0.44, P less than 0.05) and 2) EE values calculated using the postbolus isotopic enrichments are appreciably higher (19.9 +/- 7.5%) than the prebolus reference values. In conclusion, it is not advisable to collect saliva samples for DLW measurements within approximately 1 h of bolus fluid intake.

NASA Discipline Musculoskeletal↗

Tape Cassette Bacteria Detection System

The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

Source record↗