Search NASA⌕ Search

SEARCH · Search NASA

Results for “wearables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Multifunctional Silk Fibroin Hydrogels with Strong Adhesion for Tissue Sealing and Wearable Electronic Sensors

Multifunctional hydrogels with excellent adhesion, biodegradability, and conductivity are essential for overcoming the obstacles of postoperative secondary injury, flexible sensing instability, and so on. Herein, we develop a multifunctional silk fibroin (SF) hydrogel modified with poly(acrylic acid). Owing to the stable chemical cross-linking network and the abundant carboxylic acid groups of the SF network, the SF hydrogel exhibits a high tensile strength of 74.34 kPa due to sufficient cohesion and interfacial interactions. Additionally, the tensile strain reaches a maximum of 414.6%, the compressive strength is 0.9 MPa, and the shear adhesive strength for pig skin tissues is as high as 64 kPa. Compared with most hydrogels, our multifunctional SF hydrogel with a low swelling ratio provides excellent adhesion, biodegradation, and conductivity, which shows advantages in terms of invasive tissue sealing. Furthermore, the use of self-adhesive SF hydrogels as conductive hydrogels in flexible sensors also benefits the collection of physiological electricity and human motion signals in the field of wearable and implantable electronic devices.

adhesive↗

A wearable patch for continuous analysis of thermoregulatory sweat at rest

The body naturally and continuously secretes sweat for thermoregulation during sedentary and routine activities at rates that can reflect underlying health conditions, including nerve damage, autonomic and metabolic disorders, and chronic stress. However, low secretion rates and evaporation pose challenges for collecting resting thermoregulatory sweat for non-invasive analysis of body physiology. Here we present wearable patches for continuous sweat monitoring at rest, using microfluidics to combat evaporation and enable selective monitoring of secretion rate. We integrate hydrophilic fillers for rapid sweat uptake into the sensing channel, reducing required sweat accumulation time towards real-time measurement. Along with sweat rate sensors, we integrate electrochemical sensors for pH, Cl - , and levodopa monitoring. We demonstrate patch functionality for dynamic sweat analysis related to routine activities, stress events, hypoglycemia-induced sweating, and Parkinson’s disease. By enabling sweat analysis compatible with sedentary, routine, and daily activities, these patches enable continuous, autonomous monitoring of body physiology at rest.

47 OTHER INSTRUMENTATION↗

Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate

Abstract Many health diagnostic systems demand noninvasive sensing of respiratory rate, respiratory volume, and heart rate with high user comfort. Previous methods often require multiple sensors, including skin-touch electrodes, tension belts, or nearby off-the-body readers, and hence are uncomfortable or inconvenient. This paper presents an over-clothing wearable radio-frequency sensor study, conducted on 20 healthy participants (14 females) performing voluntary breathing exercises in various postures. Two prototype sensors were placed on the participants, one close to the heart and the other below the xiphoid process to couple to the motion from heart, lungs and diaphragm, by the near-field coherent sensing principle. We can achieve a satisfactory correlation of our sensor with the reference devices for the three vital signs: heart rate ( r = 0.95), respiratory rate ( r = 0.93) and respiratory volume ( r = 0.84). We also detected voluntary breath-hold periods with an accuracy of 96%. Further, the participants performed a breathing exercise by contracting abdomen inwards while holding breath, leading to paradoxical outward thorax motion under the isovolumetric condition, which was detected with an accuracy of 83%.

60 APPLIED LIFE SCIENCES↗

Carbon nanotube thermoelectric devices by direct printing: Toward wearable energy converters

Thermoelectric devices convert thermal energy to electrical energy and are particularly well-suited for energy harvesting from waste heat. Even as the number of electronic devices used in daily life proliferates, technical advances diminish the average power such devices require to perform a given function. Here, localized thermal gradients that abound in our living environments, despite having modest energy densities, are therefore becoming increasingly viable and attractive to power such devices. With this motivation, we report the design, fabrication, and characterization of single-wall carbon nanotube thermoelectric devices (CNT-TDs) on flexible polyimide substrates as a basis for wearable energy converters. Our aqueous-solution-based film fabrication process could enable readily scalable, low-cost TDs; here, we demonstrate CNT-hydroxypropyl cellulose (HPC) composite thermoelectric films by aerosol jet printing. The electrical conductivity of the composite films is controlled through the number of CNT/HPC layers printed in combination with control of the annealing conditions.

30 DIRECT ENERGY CONVERSION↗

Expanding the access of wearable silicone wristbands in community-engaged research through best practices in data analysis and integration

Wearable silicone wristbands are a rapidly growing exposure assessment technology that offer researchers the ability to study previously inaccessible cohorts and have the potential to provide a more comprehensive picture of chemical exposure within diverse communities. However, there are no established best practices for analyzing the data within a study or across multiple studies, thereby limiting impact and access of these data for larger meta-analyses. We utilize data from three studies, from over 600 wristbands worn by participants in New York City and Eugene, Oregon, to present a first-of-its-kind manuscript detailing wristband data properties. We further discuss and provide concrete examples of key areas and considerations in common statistical modeling methods where best practices must be established to enable meta-analyses and integration of data from multiple studies. Finally, we detail important and challenging aspects of machine learning, meta-analysis, and data integration that researchers will face in order to extend beyond the limited scope of individual studies focused on specific populations.

Bramer, Lisa M.↗

Wearable robotics could save the day (and your back)

How can a lightweight back-assisted exosuit help material handlers decrease back strain from repetitive lifting tasks? What are the benefits of a passive robotic shoulder support in reducing fatigue and injury for environmental cleanup workers? How can mechanical devices reduce joint and muscle injuries in a manufacturing environment? These are some of the questions a group of Laboratory engineers are asking in their ongoing quest to identify and evaluate specially designed wearable advanced technologies to assist workers and help keep them safe.

42 ENGINEERING↗

Data to Accompany: Expanding the access of wearable silicone wristbands in community-engaged research through best practices in data analysis and integration

Wearable silicone wristbands are a rapidly growing exposure assessment technology that offer researchers the ability to study previously inaccessible cohorts and have the potential to provide a more comprehensive picture of chemical exposure within diverse communities. However, there are no established best practices for analyzing the data within a study or across multiple studies, thereby limiting impact and access of these data for larger meta-analyses. We utilize data from three studies, from over 600 wristbands worn by participants in New York City and Eugene, Oregon, to present a first-of-its-kind manuscript detailing wristband data properties. We further discuss and provide concrete examples of key areas and considerations in common statistical modeling methods where best practices must be established to enable meta-analyses and integration of data from multiple studies. Finally, we detail important and challenging aspects of machine learning, meta-analysis, and data integration that researchers will face in order to extend beyond the limited scope of individual studies focused on specific populations.

Bramer, Lisa M↗

Wearable Environmental and Physiological Sensing Unit

The wearable environmental and physiological sensing unit (WEPS) is a prototype of systems to be worn by emergency workers (e.g., firefighters and members of hazardous-material response teams) to increase their level of safety. The WEPS includes sensors that measure a few key physiological and environmental parameters, a microcontroller unit that processes the digitized outputs of the sensors, and a radio transmitter that sends the processed sensor signals to a computer in a mobile command center for monitoring by a supervisor. The monitored parameters serve as real-time indications of the wearer s physical condition and level of activity, and of the degree and type of danger posed by the wearer s environment. The supervisor could use these indications to determine, for example, whether the wearer should withdraw in the face of an increasing hazard or whether the wearer should be rescued.

Spremo, Stevan↗

Wearable Health Monitoring Systems

The shrinking size and weight of electronic circuitry has given rise to a new generation of smart clothing that enables biological data to be measured and transmitted. As the variation in the number and type of deployable devices and sensors increases, technology must allow their seamless integration so they can be electrically powered, operated, and recharged over a digital pathway. Nyx Illuminated Clothing Company has developed a lightweight health monitoring system that integrates medical sensors, electrodes, electrical connections, circuits, and a power supply into a single wearable assembly. The system is comfortable, bendable in three dimensions, durable, waterproof, and washable. The innovation will allow astronaut health monitoring in a variety of real-time scenarios, with data stored in digital memory for later use in a medical database. Potential commercial uses are numerous, as the technology enables medical personnel to noninvasively monitor patient vital signs in a multitude of health care settings and applications.

Bell, John↗

Wearable Beat-to-Beat Blood Pressure Monitor

Linea Research Corporation has developed a wearable noninvasive monitor that provides continuous blood pressure and heart rate measurements in extreme environments. Designed to monitor the physiological effects of astronauts' prolonged exposure to reduced-gravity environments as well as the effectiveness of various countermeasures, the device offers wireless connectivity to allow transfer of both real-time and historical data. It can be modified to monitor the health status of astronaut crew members during extravehicular missions.

Lee, Yong Jin↗

Wearable Technology Development at NASA JSC

Final document is attached. I am going to be presenting at the Bluetooth World 2018 conference. I will be talking about my role as the lead of the Wearable Electronics and Application Research (WEAR) lab, the projects we have created using Bluetooth technology, and the future features of Bluetooth 5 that we are excited about.

Bautista, Justin↗

Wearable Biosensor Monitor to Support Autonomous Crew Health and Performance

During future human exploration missions, spaceflight crews will encounter adverse health outcomes and decrements in performance during the missions and for long term health. The Psychophysiological Research Lab is currently conducting a technology demonstration of a prototype wearable biosensor system (Astroskin) on astronaut surrogates during 30 day missions within NASAs Human Exploration Research Analog (HERA). HERA, located at Johnson Spaceflight Center, represents a flight analog for simulation of isolation, confinement and remote conditions of mission exploration scenarios. Astroskin, an autonomous medical monitoring system, consists of an intelligent garment for the upper body and a headband fitted with sensors, and associated software and hardware that can measure, transmit and store vital signs (ECG, respiration, blood pressure, etc.), sleep quality and activity level of the wearer. One of the main goals of the technology demonstration is to evaluate the performance of the Astroskin system (i.e., data quality), crew usability and comfort. To validate the Astroskin as a viable option for use during future spaceflight missions, crew data from HERA are sent to Ames researchers for processing and analyses. Crew surveys on usability and comfort will also be evaluated. This work supports the Exploration Medical Capabilities element within NASAs Human Research Program.

space analog↗

Wearable Biosensor Monitor to Support Autonomous Crew Health and Readiness to Perform

For future human exploration missions, NASA needs a health monitoring system composed of hardware that is compact, fully interoperable with an integrated data management system, and requires minimal consumables. Such a system will be achieved through the integration of small, easy to use biomedical sensors that will have the ability to measure, store and transmit physiological parameters during operational and ambulatory activity. Since 2012, the Canadian Space Agency (CSA) has been active in funding the development of wearable biomonitoring sensors. The Astroskin is the first prototype and consists of a shirt-based garment and headband with embedded sensors, and associated software and technology that measure vital signs, sleep quality and activity level of the wearer. NASA and CSA have been collaborating since 2014 to test and validate this system in a lab environment at Ames Research Center and more recently in the Human Exploration Research Analog (HERA) located at Johnson Spaceflight Center. Specific objectives of the HERA study were: 1) to assess the performance of the Astroskin biosensor system for long-term health monitoring (24-hours) capabilities and during exercise as a measure of crew fitness; 2) to obtain crew feedback on comfort and usability of the Astroskin system; 3) to demonstrate performance of Bluetooth communication during real-time transmission and for verification of data in this environment; and 4) to obtain baseline data for further development of algorithms and tools that facilitate decision support for diagnosing and monitoring of a sick or injured crewmember. HERA Campaign 3 included four missions (each 30-days in duration) with four crewmembers assigned to each mission. A total of 9 men and 7 women participated in the Astroskin evaluation that included continuous physiological monitoring (24-hours) on mission days MD-11, MD1 (high workload), MD15 (low workload), MD19, MD29, and MD+7. Mission days 19 and 29 also included 30 minutes of sub-maximal exercise on a cycle ergometer. Following each 24-hour monitoring session crew physiological data were downloaded to laptops and each crewmember completed a 28 question survey on their experiences with the Astroskin hardware and software. This presentation will focus on lessons learned from the HERA missions. Specifically it will address Astroskin system performance in terms of data loss and data quality (no comparison to lab standard devices), wireless communication with the onboard mobile device, crew usability and comfort, and future development of a next generation biomonitoring system.

crew fitness↗

Additively Printed Flexible Temperature Sensor for Wearable Applications

The flexible sensor has the capability to be mounted on any curved surfaces of applications and be used for portable devices. Additively printed sensors have received attention owing to their compact design and ability of application to non-planar surfaces. Wearable applications require capability of integration into a variety of surfaces with ability to flex, fold, twist and stretch under the stresses of daily motion. There is scarcity of data on the interaction of the process parameters with the realized performance. In addition, there is need for data focused on sensor accuracy, repeatability, and reliability. In this study, experimental analysis on function of the fabricated sensing board is conducted. The temperature sensors are made by direct write printing method with nScrypt printer. A calibration of the sensors has been conducted to confirm that resistance is well related to actual temperature and find TCR (temperature coefficient to resistance). The evolution of resistance has been correlated with the environmental temperature. The sensor hysteresis has been quantified using upswing and downswing of the environmental temperature. In addition, the effect of humidity on the temperature sensor accuracy and performance has been quantified. The effect of a polymide coat on the sensor to prevent humidity effects has also been quantified.

Pradeep Lall↗

Wearable health monitoring device

A wearable patient device is provided that includes one or more sensors. The one or more sensors can record one or both of ECG information or phonocardiographic information. The sensor information can be used to determine the blood pressure of a monitored individual, including on a continuous basis. Blood pressure can be determined using one or both of a determined time to empty or fill one or more heart chambers or first and second blood velocities. Vital sign information can be provided to a monitoring individual, including graphical representations of trend information.

Gosink, Luke J.↗