Search NASA⌕ Search

SEARCH · Search NASA

Results for “weighted residual methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

42 records · Page 3

Invariant-mass spectroscopy in projectile fragmentation reactions

The fragmentation of a projectile into a number of pieces can lead to the creation of many resonances in different nuclei. We discuss application of the invariant-mass method to the products from such reactions to find some of the most exotic resonances located furthest beyond the proton drip line. We show examples from fragmentation of a fast 13 O beam including the production of the newly identified 9 N resonance. In extracting resonance parameters from invariant-mass spectra, accurate estimates of the background from nonresonant prompt protons are needed. These prompt protons are correlated with the resonances due to long-range Coulomb interactions and will suppress events when resonance decay products and the prompt protons have small invariant masses. The shape of this background is especially important in determining the widths of wide resonances typically found at the edge of the chart of nuclides. An event-mixing recipe is proposed to describe this background, where the mixed events have reduced weighting for the smaller invariant masses to account for the effect of the Coulomb final-state interactions. The weighting is based on the measured correlations of heavier hydrogen isotopes with the resonances or the projectile residues. We also show that the relative magnitude of the background can be reduced in some cases by selecting events where the resonance decay products are accompanied by a deuteron or triton cluster. Here, the deuteron and triton clusters are largely not products of resonant decay and thus events with an accompanying cluster are associated with fewer background protons than events without them. The width of the 5/2¯ state in 9 C with the new background prescription was found to be consistent with the value obtained using proton elastic scattering on 8 B. Improved values for the widths of 10 C, 10,11 N, and 12 O resonances were also obtained using the new background prescription.

6 ≤ A ≤ 19↗

Infrared Cloud Imager Instrument Intercomparison Report

The Infrared Cloud Imager Instrument Intercomparison was a guest instrument deployment by NWB Sensors to the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) User Facility observatory on the Southern Great Plains (SGP) between May 18 and December 12, 2023. NWB Sensors is a company that has developed a commercially available infrared cloud imager (ICI). The ICI provides radiometrically calibrated, full-sky images of the downwelling infrared radiance in the 7.3-14 µm band. In addition, it provides cloud radiance as the residual between the observed radiance and the modeled cloud-free radiance as well as derived cloud products. The instrument is used in applications that require consistent detection of clouds across day and night. For more information, consult the instrument's webpage. The primary goal of the deployment was to validate the radiometric accuracy of the ICI. The ICI uses a proprietary calibration method to convert the raw data from its infrared camera into downwelling radiance. Unlike similar instruments, the system does not have an onboard blackbody calibration standard. Instead, NWB Sensors characterizes each ICI camera individually in an environmental chamber while looking at a blackbody standard. The resulting (proprietary) calibration is used operationally in the instrument and has been demonstrated to be stable over long periods. To validate the radiometric products from the ICI, an intercomparison between the ICI data products and those from ARM’s atmospheric emitted radiance interferometer (AERI) was made. The AERI is a best-in-class instrument for measuring downwelling infrared radiance (Gero et al. 2025). A weighted integration of the AERI’s spectral radiances across the ICI’s camera response was performed. The resulting radiance (herein called the AERI radiance) was directly compared to the zenith radiance concurrently observed by the ICI. The results of these comparisons are reported in the next section of this report.

54 ENVIRONMENTAL SCIENCES↗

Tomography of the gamma-ray sky from cross-correlation with DESI DR2 and unWISE galaxies

We study the origin of extragalactic gamma-ray emission observed by Fermi-LAT, using the cross-correlation of the gamma-ray sky with maps of large-scale structure provided by the DESI and unWISE surveys. Tomographic cross-correlation reveals the bias-weighted redshift distributions of gamma-ray sources. We first illustrate this method by cross-correlating detected gamma-ray point sources with large-scale structure. We find a significant cross-correlation and infer a point source redshift distribution broadly consistent with the distribution of identified optical counterparts previously reported in the literature, as well as a similar linear bias ($b \approx 2$) to massive galaxies that host bright active galactic nuclei. We then study the clustering of the Fermi unresolved gamma-ray background (UGRB), both in auto-correlation and in cross-correlation with large-scale structure. We detect the cross-correlation of the UGRB and LSS at $\sim 10σ$ in total, with highly significant detections from both DESI and unWISE. Our measurements suggest that the redshift distribution of the UGRB is broadly consistent with the redshift distribution of detected point sources. Additionally, we find a relatively weak amplitude for the cross-correlation with large-scale structure at z < 2, suggesting a significant fraction of the UGRB does not come from z < 2 large-scale structure. A natural candidate is contamination of from residual Galactic emission, and our best estimate of the contamination level derived from the UGRB auto-spectrum suggests that the mean bias of UGRB sources is indeed quite similar to the bias of detected Fermi point sources. However, we cannot exclude additional emission from gamma-ray sources at high redshift, z > 2, and we suggest that cross-correlation with tracers at z > 2, including CMB lensing, would be the ideal way to determine the fraction of z > 2 emission.

Krolewski, Alex [Waterloo U., Math. Dept.; Waterlo↗

Atomistic Simulations of Polydisperse Lignin Melts Using Simple Polydisperse Residue Input Generator

Understanding the physics of lignin will help rationalize its function in plant cell walls as well as aiding practical applications such as deriving biofuels and bioproducts. Here, in this work, we present SPRIG (Simple Polydisperse Residue Input Generator), a program for generating atomic-detail models of random polydisperse lignin copolymer melts i.e., the state most commonly found in nature. Using these models, we use all-atom molecular dynamics (MD) simulations to investigate the conformational and dynamic properties of polydisperse melts representative of switchgrass (Panicum virgatum L.) lignin. Polydispersity, branching and monolignol sequence are found to not affect the calculated glass transition temperature, T g . The Flory–Huggins scaling parameter for the segmental radius of gyration is 0.42 ± 0.02, indicating that the chains exhibit statistics that lie between a globular chain and an ideal Gaussian chain. Below T g the atomic mean squared displacements are independent of molecular weight. In contrast, above T g , they decrease with increasing molecular weight. Therefore, a monodisperse lignin melt is a good approximation to this polydisperse lignin when only static properties are probed, whereas the molecular weight distribution needs to be considered while analyzing lignin dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Tank 9H Annulus Sample in Support of Residual Material Inventory Determinations

The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC) to provide sample preparation and characterization of the Tank 9H annulus sample in support of Residual Material Inventory Determinations. One Tank 9H sample in three vials [HTF-9-25-13, HTF-9-25-14 and HTF-9-25-15], with each vial containing approximately 200 mL of the Tank 9H annulus salt solution, were delivered to the SRNL Shielded Cells for sample preparation and characterizations in February 2025. The density of the “as-received” solution contained in each of the three Tank 9H annulus sample vials were determined followed by a solid-liquid separation on each one using 0.45-micron Nalgene® nylon filter membranes. The resulting filtrates were combined to form the Tank 9H annulus sample with a total volume of about 600 mL. The combined wet solid fractions, about a total of 4.8 grams of salt material, remaining on the filter membranes were air-dried in the Shielded Cells for 72 hours. The total weight of the air-dried solids was 2.1 grams. These air-dried solids were washed with deionized water (DI water) at a phase ratio of 60 mL DI water/gram of solids to recover insoluble solids, if any. No visible or measurable quantity of insoluble solids were recovered after DI water washing of the air-dried solids because the air-dried solids completely dissolved in the DI water. The solid fraction-wash water was not combined with the 600 mL of the filtrate solution, and the resulting solution was not screened or analyzed for radionuclides. Aliquot sample volumes of the undiluted Tank 9H annulus sample were sent to the SRNL analytical services groups for radionuclides, elementals, anions and total mercury analysis by various methods including radiochemical separations/counting methods, inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) and special preparations. All sample analyses were performed in triplicate. This report presents the analytical characterization results for the Tank 9H annulus sample. The results are also reported where analytical methods yielded additional analytes, other than those requested by SRMC. In the characterization of the Tank 9H annulus sample, the detection limits for all the analytes, as specified in the Technical Task Request (TTR) and Task Technical and Quality Assurance Plan (TTQAP), were met.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reducing Mass of Steel Auto Bodies using Thin Advanced High Strength Steel with Carbon-Fiber Reinforced Epoxy

Diversitak, a company based in Detroit, MI, has developed a proprietary, low specific gravity, carbon fiber-reinforced epoxy (CFRE) under U.S. patent number 9,963,58832. Preliminary testing on this new material conducted in collaboration with ArcelorMittal Steel Company proved out the CFRE concept. A thin layer of this CFRE was applied to a stamped sheet of steel with residual stamping oils from a mill, in a time corresponding to automotive processing (e.g., ~15 seconds), and processed following automotive e-coat procedures (phosphating + 175–200°C heating), to complete the curing. No problems with adherence or performance were noted. While the CFRE does add weight to a thin gauge steel panel, it weighs much less than what is displaced by using thicker conventional mild steel gauges. The application of the coating showed a significant increased dent resistance, oil canning resistance, and part stiffness.This current two-year project was designed to mature this new technology to near manufacturing readiness to reduce the weight of a vehicle and lower the cost of weight reduction. The process involves the use of thinner gauge steels than are currently used. The collaborative development team included two industrial manufacturers: Diversitak and ArcelorMittal Steel Company; LightMAT; and two National Laboratories: Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL). The team developed a new manufacturing process to reduce the weight of a vehicle and lower the cost of weight reduction, as well as a better understanding of how to apply the coating so that it will perform to a high standard in-service. The team also performed an in-depth study to determine the long-term durability of the materials manufactured using this technology and well-known automotive industry standard tests.The overall process involved stiffening the thinner gauge steel by applying the CFRE on only one side. To accomplish this goal, the optimal reinforcement fiber length and fiber concentration was first determined. This was followed by measuring the coefficient of thermal expansion (CTE) in all three directions, so it could be fed into manufacturing models and methods for rapidly and inexpensively applying the coating. This was followed by panel level evaluations of the coating and steel combination, and then by full part demonstration of the technology on door panels. The final step was corrosion testing of the parts.ArcelorMittal characterized the advanced high strength steel (AHSS) (e.g., metallurgy-heat treatment for required AHSS properties as a function of the sheet thickness, state of internal stress) and quantified CFRE adhesion to the steel as a function of sheet preparation (e.g., rolling and stamping).ORNL optimized the fiber length, fiber concentration, and coating thickness for best vehicle function and performance at the least cost. Along with the suppliers, ORNL developed a durable CFRE application process (e.g., gun material, design, robotic dispensing process) and identified the adhesion stability of the CFRE during process holding. An approach to ensure that application/curing timing conforms to conventional assembly line speed and plant cycle times was determined. ORNL also determined the CTE of the material in all three directions and performed material scanning electron microscopy (SEM) analyses.INL characterized the corrosion properties of the steel panels coated with CFRE. The panels were investigated for corrosion resistance and stability as replacement materials used in automotive body panels to reduce mass. The coupons tested at INL were supplied by Diversitak after an optimized CFRE formulation was achieved in the already coated form for corrosion testing.

99 GENERAL AND MISCELLANEOUS↗