Cosmic X-ray observations with OSO-8

The GSFC Cosmic X-ray Spectroscopy experiment aboard OSO-8 has operated successfully since launch providing spectral and temporal data on X-ray sources in tha energy range 2-60 keV. Analysis of quick look data shows a variety of spectral features, some stable, others variable, which will increase understanding of the nature of individual sources. In particular, observed emission and absorption features that can be attributed to iron will result in abundance measures of this important element in sources such as some X-ray binaries, the supernova remnant Cas A, and the nucleus of the galaxy Cen A.

Serlemitsos, P. J.↗

X ray spectra of X Per

The cosmic X-ray spectroscopy experiment on OSO-8 observed X Per for twenty days during two observations in Feb. 1976 and Feb. 1977. The spectrum of X Per varies in phase with its 13.9 min period, hardening significantly at X-ray minimum. Unlike other X-ray binary pulsar spectra, X Per's spectra do not exhibit iron line emission or strong absorption features. The data show no evidence for a 22 hour periodicity in the X-ray intensity of X Per. These results indicate that the X-ray emission from X Per may be originating from a neutron star in a low density region far from the optically identified Be star.

Becker, R. H.↗

X-ray spectra of X Persei

The GSFC cosmic X-ray spectroscopy experiment on OSO 8 observed X Per for 20 days during two observations in 1976 February and 1977 February. The spectrum of X Per varies in phase with its 13.9 minute period, hardening significantly at X-ray minimum. Unlike other X-ray binary pulsar spectra, those of X Per do not exhibit iron line emission or strong absorption features. Our data show no evidence for a 22 hour periodicity in the X-ray intensity of X Per. These results indicate that the X-ray emission from X Per may be originating from a neutron star in a low-density region far from the optically identified Be star.

Becker, R. H.↗

New X-ray and optical observations of the X-ray discovered QSO-galaxy pair 1E 0104.2 + 3153

New X-ray and optical observations are presented of the QSO-galaxy pair 1E 0104.2 + 3153, originally discovered as a serendipitous source in the Einstein Observatory Medium Sensitivity Survey (Gioia et al., 1984). Results from an extremely deep Exosat observation are used to suggest that the QSO rather than the compact group of galaxies is the optical counterpart of the IPC source. High-resolution (1-A) spectroscopy of the broad-absorption-line QSO, which fails to confirm the Ca II H and K absorption features reported by Stocke et al., (1984), is presented and discussed. The presence of broad absorption lines in the QSO spectrum may indicate that intrinsic absorption is the cause of the nondetection of this source in the soft Exosat energy band. Optical monitoring of the QSO over a 2-yr period indicates variability. Possible interpretations of this phenomenon are intrinsic luminosity variation or a cessation of a gravitational lensing effect acting at the time of the Einstein observation.

Gioia, I. M.↗

Studies of the Si/SiO2 interface using synchrotron radiation

Synchrotron radiation photoemission spectroscopy (SRPS) in the 1-4 KeV photon energy range is a useful tool for interface characterization. Results are presented of a series of studies of the near-interface region of Si/SiO2 which confirm that a bond strain gradient exists in the oxide as a result of lattice mismatch. These experiments include measurement of photoemission lineshape changes as a function of photon energy, corresponding changes in the electron escape depth near the interface, and surface extended X-ray absorption fine structure (SEXAFS) measurements directly indicating the shortening of the Si-Si second nearest neighbor distance in the near-interface region of the oxide.

Hecht, M. H.↗

X-ray spectroscopy of AGN with the AXAF 'Microcalorimeter'

A novel technique for X-ray spectroscopy has been configured as part of the definition payload of the AXAF Observatory. It is basically a calorimeter which, operating at 0.1 K, senses the total conversion of single photoelectrically absorbed X-rays via the differential temperature rise of the absorber. The technique promises to achieve less than 10 eV FWHM with near-unit efficiency simultaneously over the entire AXAF bandpass. This combination of high resolution and high efficiency allows for the possibility of investigating thermal, fluorescent and absorption X-ray line features in many types of X-ray source, including a large sample of active galactic nuclei.

Holt, Stephen S.↗

Accretion powered X-ray pulsars

The current theoretical understanding of the properties of X-ray pulsars is assessed through a comparison with unified descriptions of 14 such systems, extending over six orders of magnitude in luminosity, in whose phase averaged spectra the only notable trend is a less abrupt high energy cutoff in the lower luminosity systems. Detailed pulse phase spectroscopy is given for five of the systems. A reexamination of the pulse phase spectra of 4U 0115 + 63 has uncovered electron cyclotron lines at 11.5 and 23 keV that appear to be in absorption at pulse peak and in emission during an interpulse. Spectral hardening regions such as those from Her X-1 are a common feature in the low energy pulse of many pulsars, and may represent the passage of the magnetic axis through the observer's line of sight. Attention is given to the nature of the beaming from Her X-1, and it is concluded that a pencil beam configuration represents the simplest explanation of the overall properties of the pulse.

White, N. E.↗

X-ray photometry and spectroscopy of T Tauri stars

Follow-up Einstein X-ray observations of four fields containing pre-main-sequence stars are presented. A search has been made for evidence of variability on time scales of hours and of 1 year. A large, slow flare in AS 205, and the X-ray disappearance of AA Tau are reported. Otherwise, T Tauri stars appear no more variable in X-rays than do active solar-like stars. An attempt has been made to determine spectral parameters for a number of the brighter sources. X-ray absorption column densities are consistent with those inferred from A(v), and T(x) of about 10-million K, in all cases. The importance of these observations for models of T Tauri stars and their coronae is considered.

Walter, F. M.↗

Phase resolved optical spectroscopy of the compact X-ray binary 2A1822-371

The optical, X-ray, and ultraviolet emissions of the X-ray system 2A1822-371 are modulated with a period of 5.57 hr. The 5.57 hr modulation is believed to reflect orbital motion about a mass donating companion star. The modulation at high energies is caused by the combined effects of an occultation by the companion and by a bulge on the accretion disk. The present investigation is concerned with an extension of the study of 2A1822-371, taking into account medium resolution optical spectroscopy of the system covering the 5.57 hr cycle. Broad shallow absorption lines are observed in the optical spectrum of 2A1822-371. These lines are similar to the rotationally broadened lines which are found in the spectra of disk accreting cataclysmic variables. Their presence in 2A1822-371 is, therefore, strong confirmation that it is a disk accreting star. The He II 4686 A and H-alpha emission lines have a breadth comparable to the absorption lines at all phases in the 5.57 hr cycle.

Mason, K. O.↗

X-ray spectroscopy of five BL Lacertae objects

Five X-ray bright BL Lacertae objects were observed in the energy range 0.6-4.5 keV with the solid state spectrometer (SSS) of the Einstein Observatory. The 14 SSS spectra obtained represent most of the X-ray spectra of BL Lac objects with resolution better than approximately 3. These data do not reveal the presence of large amounts of thermal gas, with upper limits for the equivalent width of individual spectral features typically less that about 100 eV. However, the SSS spectra are the first set of X-ray data to indicate low-energy absorption in excess of that caused by the cold interstellar matter in the Galaxy. Comparison with contemporaneous, lower energy X-ray data implies that this absorption does not arise in cold neutral material, but in hotter, highly ionized material, probably intrinsic to the source. All five BL Lac objects have X-ray continua that are well fitted by power-law models, with power-law energy indices usually greater than about 1. In a few cases, a flattening at higher energies is observed; these and other data suggest that two-component X-ray spectra, steep at low energies and flat at high energies, are a common feature of BL Lac objects. Three of the five sources clearly vary between SSS observations, with time scales ranging from days to years. A historical synopsis of the X-ray spectral data confirms the tendency for BL Lacertae objects to be highly variable in the X-ray band but reveals no correlation between spectral and intensity changes.

Urry, C. M.↗

High-resolution X-ray spectroscopy of the Crab Nebula and the oxygen abundance of the interstellar medium

The measurement and analysis of a high-resolution soft X-ray spectrum of the Crab Nebula obtained with the Focal Plane Crystal Spectrometer on the Einstein Observatory are reported. A hydrogen column density of 3.45 + or - 0.42 x 10 to the 21st/sq cm and an oxygen column density of 2.78 + or - 0.55 x 10 to the 18th/sq cm, corresponding to an oxygen abundance of 1.1 + or - 0.3 times solar, were obtained. The absence of any evident oxygen depletion effects suggests that most interstellar grains are reasonably transparent to soft X-rays, implying sizes of less than 0.4 micron. The detailed spectrum in the vicinity of the oxygen edge gives marginal evidence for a resonant absorption line and suggests an edge from singly ionized oxygen.

Schattenburg, M. L.↗

X-ray spectroscopy of the ultrasoft transient 4U 1543 - 47

The X-ray transient 4U 1543 - 47 was observed in August 1983 by the Exosat observatory near the maximum of an outburst. The X-ray spectrum was measured using a gas scintillation proportional counter (GSPC) and a transmission grating spectrometer (TGS). A broad (FWHM about 2.7 keV) line at 5.9 keV is detected in the GSPC, which is interpreted as a redshifted and broadened iron K-alpha line. The line broadening and redshift may arise from either Compton scattering in a cool plasma with small optical depth and/or from Droppler and relativistic effects in the vicinity of compact object. The spectrum below 2 keV, obtained with the TGS, shows evidence for a broad emission feature at 0.74 keV, which may be an iron L-transition complex. However, such an emission feature could be an artifact caused by an anomalously low interstellar absorption by neutral oxygen. The contimuum emission is extremely soft and is well described by an unsaturated Comptonized spectrum from very cool plasma (kT = 0.84 keV) with large scattering depth.

Van Der Woerd, H.↗

Observations of absorption lines from highly ionized atoms

In the ultraviolet spectra of hot stars, absorption lines can be seen from highly ionized species in the interstellar medium. Observations of these features which have been very influential in revising the perception of the medium's various physical states, are discussed. The pervasiveness of O 6 absorption lines, coupled with complementary observations of a diffuse background in soft X-rays and EUV radiation, shows that there is an extensive network of low density gas (n approx. few x 0.001/cu cm) existing at coronal temperatures log T = 5.3 or 6.3. Shocks created by supernova explosions or mass loss from early-type stars can propagate freely through space and eventually transfer a large amount of energy to the medium. To create the coronal temperatures, the shocks must have velocities in excess of 150 km/sec; shocks at somewhat lower velocity (v = 100 km/sec) can be directly observed in the lines of Si3. Observations of other lines in the ultraviolet, such as Si 4V and C 5, may highlight the widespread presence of energetic UV radiation from very hot, dwarf stars. More advanced techniques in visible and X-ray astronomical spectroscopy may open up for inspection selected lines from atoms in much higher stages of ionization.

Jenkins, Edward B.↗

Observations of Absorption Lines from Highly Ionized Atoms

In the ultraviolet spectra of hot stars, absorption lines can be seen from highly ionized species in the interstellar medium. Observations of these features which have been very influential in revising the perception of the medium's various physical states, are discussed. The pervasiveness of O 6 absorption lines, coupled with complementary observations of a diffuse background in soft X-rays and EUV radiation, shows that there is an extensive network of low density gas (n approx. fewX 0.001/cucm) existing at coronal temperatures, 5.3 or = log T or = 6.3. Shocks created by supernova explosions or mass loss from early-type stars can propagate freely through space and eventually transfer a large amount of energy to the medium. To create the coronal temperatures, the shocks must have velocities in excess of 150 km/sec; shocks at somewhat lower velocity 9v or = 100 km/sec) can be directly observed in the lines of Si3. Observations of other lines in the ultraviolet, such as Si 4V and C 5, may highlight the widespread presence of energetic uv radiation from very hot, dward stars. More advanced techniques in visible and X-ray astronomical spectroscopy may open up for inspection selected lines from atoms in much higher stages of ionization.

Jenkins, E. B.↗

Stellar crystal X-ray spectroscopy on OSO-8

The large-area graphite crystal X-ray spectrometer on the OSO-8 satellite is described, and its response to stellar line and continuum radiation is discussed. A high resolution X-ray spectrum of Sco X-1 obtained from a preliminary analysis of quick look data shows a strong, smooth continuum with an absence of emission or absorption features over the energy range 2.2 to 8 keV. Upper limits are set on narrow line emission from highly ionized states of S, Ca, and Fe.

Kestenbaum, H. L.↗

The case for a burst from 3U 0614+09

A single flare event with a rise time of about 7 s and a decay time of approximately 40 s was observed by the Goddard cosmic X-ray spectroscopy experiment on OSO-8 during observations of 3U 0614+09 in September 1975. The possibility is discussed that the source was 3U 0614+09, which has been compared with the low-mass binary Sco X-1. The spectra during the event could be fitted with blackbody (kT = 0.8-1.1 keV) or thermal bremsstrahlung (kT = 1.1-2.5 keV) models with absorption by cool material. In the blackbody model the source was of the order of 1 million cm in size.

Swank, J. H.↗

Einstein Observatory pulse-phase spectroscopy of Hercules X-1

Spectra of the Her X-1 pulsations from 0.15 to 4.5 keV have been obtained with the Objective-Grating and Solid State Spectrometers on the HEAO 2 Einstein Observatory. The spectra show no distinct atomic emission or absorption features, except for broad emission near 1 keV possibly due to unresolved Fe L shell emission lines. Spectrally resolved pulse waveforms show a dramatic 240 deg phase shift for E less than 0.85 keV. The soft X-rays are interpreted as the result of the reprocessing of the hard X-ray beam by the inner disk at the magnetospheric boundary of the neutron star, and several spectroscopic and phase observations are suggested which could provide further knowledge of these structures.

Mccray, R. A.↗

Analysis of TQCM surface contamination adsorbed during the Spacelab I Mission

The Temperature-Controlled Quartz Crystal Microbalance (TQCM) system was flown on the Spacelab I Mission as part of the Induced Environment Contamination Monitor to monitor surface contamination (SC) in the payload bay. SC on the five sensors of the TQCM was analyzed by means of IR spectroscopy, scanning electron spectroscopy, and energy dispersive X-ray fluorescence. The amount of SC ranged from 1.4 micrograms/sq cm for the -Z sensor to 39.9 micrograms/sq cm for the +X sensor. The IR analysis showed strong CH2, CH3, and carbonyl absorption bands, indicative of ester and polyester compounds found in adhesives, plasticizers, and tape. The particulates (mostly ranging from 1 micron to 20 microns in size) were mainly composed of Mg, Al, Al2O3, and Si, and probably originated in the solid rocket firings.