Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

X-ray line emission from the Puppis A supernova remnant - Oxygen lines

Six prominent X-ray emission lines of O VII and O VIII have been detected from a portion of the Puppis A supernova remnant in observations with the Einstein Observatory Focal Plane Crystal Spectrometer. The lines are sufficiently well resolved to serve as diagnostics of the emitting plasma. From the relative intensities of the lines, it is inferred that the population of O VIII is about 1.5 times that of O VII, and that electron collisions are the dominant excitation mechanism in the plasma. A locus of allowed electron temperatures and interstellar-absorption column densities is derived: 1.5 x 10 to the 6th K, and (2-6) x 10 to the 21st per sq cm. The data are consistent with either a thin plasma source in equilibrium at a temperature of 2.2 x 10 to the 6th K with a column density of 4 x 10 to the 21st per sq cm, or with a nonequilibrium source in which the electrons have been shock-heated to a higher temperature and oxygen is underionized.

Winkler, P. F.↗

The multifrequency spectrum of the starburst galaxy NGC 2782

The nuclear region of NGC 2782 has been observed at radio, millimeter, infrared, optical, ultraviolet, and X-ray frequencies to understand the ionization source that gives rise to the narrow emission lines. The continuum is probably caused by a normal galactic population plus considerable numbers of young stars and warm dust. In the ultraviolet and optical spectra, which are powerful diagnostics, no strong lines are detected in the 1200 A-3200 A region aside from L-alpha, and the optical emission lines cover only a narrow ionization range. The line and continuum properties suggest that NGC 2782 is a starburst galaxy, in which young stars photoionize the surrounding gas.

Kinney, A. L.↗

Three-dimensional reconstruction and display of the heart, lungs and circulation by multiplanar X-ray scanning videodensitometry

A device was developed which makes possible the dynamic reconstruction of the heart and lungs within the intact thorax of a living dog or human and which can record approximately 30 multiplanar X-ray images of the thorax practically instantaneously, and at frequent enough intervals of time and with sufficient density and spatial resolution to capture and resolve the most rapid changes in cardiac structural detail throughout each cardiac cycle. It can be installed in a clinical diagnostic setting as well as in a research environment and its construction and application for determination and display in real-time modes of cross sections of the functioning thorax and its contents of living animals and man is technologically feasible.

Robb, R. A.↗

High-resolution, far-ultraviolet study of Beta Draconis (G2 Ib-II) - Transition region structure and energy balance

High-resolution far ultraviolet spectra of the star Beta Draconis have been obtained with the IUE satellite. The observations and emission line data from the spectra are presented, the interpretation of the emission line widths and shifts is discussed, and the implications are given in terms of atmospheric properties. The emission measure distribution is derived, and density diagnostics involving both line ratios and line opacity arguments is investigated. The methods for calculating spherically symmetric models of the atmospheric structure are outlined, and several such models are presented. The extension of these models to log T(e) greater than 5.3 using the observed X-ray flux is addressed, the energy balance of an 'optimum' model is investigated, and possible models of energy transport and deposition are discussed.

Brown, A.↗

Science on the Space Shuttle

On the Space Shuttle's third flight, scientific instruments will study the electromagnetic environment with charging and electron beams. Beam plasma discharge will be studied. The plasma diagnostics package contains electromagnetic and particle sensors to study the ionosphere. An attempt will be made to establish a more accurate base of solar UV irradiance measurements with an absolute error of 10 percent or less over the wavelength region 120-400 nm. The solar flare X-ray polarimeter will observe flare X-rays emitted between 5 and 30 keV and measure their polarization as a function of time and photon energy. A photopolarimeter will help study zodiacal light, and interplanetary dust will be sampled by a section of thick aluminum foil. Plant seedlings will be grown to research the effect of near-zero gravity on lignification. A thermal canister experiment will help determine whether instruments can be maintained at a fixed temperature under varying thermal loads.

Neupert, W. M.↗

Polar 5 - An electron accelerator experiment within an aurora. I - Instrumentation and geophysical conditions

A mother-daughter rocket was launched over two auroral structures, which included a 10 keV electron accelerator and a series of diagnostic instruments for monitoring optical and wave effects generated through beam-atmospheric interactions and production of secondary electrons. The instrumentation, the ground and rocket background measurements obtained, and some of the beam effects on various geophysical parameters are presented. Attention is given to the rocket geometry, capacitance probe, particle counters, photometers, and the bremsstrahlung X-ray detector. Observations on the plasma environment, auroral particle precipitation, d.c. electric field, optical emissions, and auroral background HF and VLF emissions are also discussed.

Maehlum, B. N.↗

Fabrication of optical components for the ultraviolet spectrometer and polarimeter on the Solar Maximum Mission

The Solar Maximum Mission (SMM) satellite was launched in February 1980 into a 573 km high circular orbit. It contains X-ray, UV, and optical instruments for the simultaneous observation of solar flares. The ultraviolet spectrometer and polarimeter (UVSP) is one of these instruments. The objectives of the UVSP require the employment of a raster scanning telescope to study the spatial dynamics of flares, the use of a high resolution spectrometer to select and scan spectral lines for temperature and velocity diagnostics, and the utilization of a polarimeter to measure magnetic fields in the solar transition zone. The present paper has the objective to provide a description of the optical fabrication techniques developed for the instrument. Attention is given to telescope mirrors, metering rods, the Ebert mirror, grating blanks, a four-mirror polarizer, beam splitter assemblies, beam splitter fabrication, deflector mirrors, and shipping containers.

Spencer, R. S.↗

Extremely rapid radio spikes in flares: A review

Radio spikes of a few to tens of milliseconds of the solar radio emission have recently seen a surge of interest of theoreticians who are fascinated by their high brightness temperature of up to 10 to the 15th power K, their association with hard X-ray bursts, and a possibly very intimate relation to electron acceleration. Their bandwidth and global distribution in frequency were quantitatively measured only recently. This review is intended to emphasize the considerable extend of old and new observational knowledge which is hardly touched upon by theory. The wide range of spike observations is summarized and brought into perspective of recent models. It is concluded that spikes yield a considerable potential for the diagnostics of energetic particles, their origin, and history in astrophysical plasmas.

Benz, A. O.↗

Dense plasma focus production in a hypocycloidal pinch

A type of high-power pinch apparatus consisting of disk electrodes was developed, and diagnostic measurements to study its mechanism of dense plasma production were made. The collapse fronts of the current sheets are well organized, and dense plasma focuses are produced on the axis with radial stability in excess of 5 microns. A plasma density greater than 10 to the 18th power/cubic cm was determined with Stark broadening and CO2 laser absorption. A plasma temperature of approximately 1 keV was measured with differential transmission of soft X-rays through thin foils. Essentially complete absorption of a high-energy CO2 laser beam was observed. The advantages of this apparatus over the coaxial plasma focus are in (1) the plasma volume, (2) the stability, (3) the containment time, (4) the easy access to additional heating by laser or electron beams, and (5) the possibility of scaling up to a multiple array for high-power operation.

Lee, J. H.↗

Computerized X-ray reconstruction tomography in stereometric analysis of cardiovascular dynamics

A computerized technique is proposed for obtaining cross-sectional images of the dynamic spatial distribution of X-ray attenuation covering the entire anatomic extent of the thorax and its contents in living dogs with a resolution of 1 mm and at time intervals of 1/60 sec. Use is made of an X-ray imaging chain which is a new high-performance video-fluoroscopic system, unique in its design and construction and called SSDSR for single source dynamic spatial reconstructor. This dynamic spatial reconstruction system is shown to provide the temporally and spatially coherent multiple cross sections required to obtain the full three-dimensional anatomic and simultaneous hemodynamic information necessary for detailed quantitative analyses of regional cardiopulmonary and vascular functions in both basic investigations of animals and clinical diagnostic applications to patients. Numerous photographs supplement the text.

Robb, R. A.↗

High temperature UF6 and plasma research

Research currently under way on technology for uranium plasma core reactors is reviewed. A feeder system to provide a controlled and steady flow of UF6 at rates up to 5 g/sec and temperatures up to 500 K into rf plasma test chambers operating at pressures of up to 20 atm has been developed. Plasma emission and dye laser absorption measurements have been used to estimate the radial distribution of uranium atom number density within the plasma. X-ray absorption equipment and techniques have also been employed to measure the amount of uranium in the plasma, and dc plasma torch experiments have shown variations in plasma VUV emission with temperature. Analysis of residues deposited on various test-chamber components after plasma tests reveals traces of several uranium oxides, including UO2F2, and various exhaust duct configurations with flow augmentation are under investigation as means of preventing uranium deposition. Other areas of research include off- and on-line exhaust gas diagnostics, and a UF6/Ar injection, separation and recirculation system.

Roman, W. C.↗

A theoretical model study of observed correlations between whistler mode waves and energetic electron precipitation events in the magnetosphere

A recently extended test particle computer model of the gyroresonance wave-particle interaction in the magnetosphere is applied to previously reported cases of observed correlations between whistler mode waves and ionospheric responses to particle precipitation. Three different ionospheric effects, namely, X-ray bursts, photoemissions, and D region perturbations, all correlated with VLF waves and believed to be caused by precipitated particles, are considered. The precipitation flux level, the pulse shape, and the associated time delays are computed for the parameters relevant to each case and are compared with values deduced from the data. The results demonstrate that the existing theoretical model can be useful for interpreting experimental results of this kind. Furthermore, the model results and observations, used together, provide a basis for additional diagnostics of the various parameters of the cold and energetic particle distributions in the magnetosphere. For example, when applied to the observed photoemission case (Helliwell et al., 1980) the model results imply that the trapped energetic particle distribution function at the time could be modeled as proportional to E exp -n/2 with n about 3.5 to 6, where E is the particle energy.

Chang, H. C.↗

Inner-shell transitions in Fe XIX-XXII in the X-ray spectra of solar flares and Tokamaks

Calculated spectra of the ions Fe XIX-XXII for various densities and temperatures are presented, thereby extending the work begun by Doschek, Feldman, and Cowan (1981). The calculations are based on a code (the Cowan code) that computes both the level structure of an ion and intensity factors for the 1s-2p satellite lines. A comparison is made between the calculated spectra and those observed in solar flares by the P78-1 and SMM instruments. The observed intensities of Fe XX lines, which are the most sensitive to density, are found to agree well with those calculated in the low-density limit. The agreement for lines arising from other ions is also very good. It is also seen that the predicted density variations in Fe XX are confirmed by the higher density Princeton Large Torus plasmas. Thus a possible useful density diagnostic is indicated for tokamak and high-density astrophysical plasmas, perhaps including some solar flares.

Phillips, K. J. H.↗

Solar wind and coronal structure

Spectroscopic diagnostic techniques used to determine the coronal source region of the solar wind, and results of preliminary applications are examined. The topics reviewed are magnetic fields, coronal mass ejections, coronal holes, flow velocities, coronal temperatures, fine spatial structure, and future observational programs. The physical mechanisms responsible for plasma heating, solar-wind acceleration, the transport of mass momentum and energy, and the spatial differentiation of chemical abundances are also discussed. Among the data presented are Skylab's white-light coronagraph photograph of a coronal transient, X-ray photographs of the corona, and spectroheliograms showing bright points overlying polar plumes, and macrospicules.

Withbroe, G. L.↗

Production of dense plasmas in a hypocycloidal pinch apparatus

A high-power pinch apparatus consisting of disk electrodes was developed, and diagnostic measurements to study its mechanism of dense plasma production have been made. The collapse fronts of the current sheets are well organized, and dense plasma foci are produced on the axis with radial stability in excess of 5 microsec. A plasma density greater than 10 to the 18th power per cu cm is determined with Stark broadening and CO2 laser absorption. Essentially complete absorption of a high-energy CO2 laser beam has been observed. A plasma temperature of approximately 1 keV is measured with differential transmission of soft X-rays through thin foils. The advantages of this apparatus over the coaxial plasma focus are improvements in (1) plasma volume, (2) stability, (3) containment time, (4) access to additional heating by laser or electron beams, and (5) the possibility of scaling up to a multiple array for high-power operation.

Lee, J. H.↗

A survey of X-ray line emission from the supernova remnant Puppis A

Initial results from the first high-resolution study of the X-ray spectrum of a supernova remnant are reported. The spectrum of Puppis A between 500 and 1100 eV has been surveyed with the Focal Plane Crystal Spectrometer on the Einstein Observatory and the flux in eight lines and three line blends from various transitions of highly ionized nitrogen, oxygen, neon, and iron has been measured. The spectrum resembles that of active regions in the solar corona, but the neon lines seem enhanced relative to the oxygen lines, and both are enhanced relative to iron. The observed line strengths serve as diagnostics of the physical conditions in the emitting material. Without a priori assumptions, the ionization temperatures of O (2.2 million K) and Ne (4 million K) and the dominant ionization stage of Fe (Fe XVII) are deduced. Isothermal equilibrium plasmas or homogeneous nonequilibrium plasmas as descriptions of the source are ruled out. It is concluded that Puppis A must contain plasma over a temperature range 2-million to 5-million K with an intervening absorption column of 4 x 10 to the 21st/sq cm.

Winkler, P. F.↗

Cardiovascular and pulmonary dynamics by quantitative imaging

The accuracy and range of studies on cardiovascular and pulmonary functions can be greatly facilitated if the motions of the underlying organ systems throughout individual cycles can be directly visualized and readily measured with minimum or preferably no effect on these motions. Achievement of this objective requires development of techniques for quantitative noninvasive or minimally invasive dynamic and stop-action imaging of the organ systems. A review of advances in dynamic quantitative imaging of moving organs reveals that the revolutionary value of cross-sectional and three-dimensional images produced by various types of radiant energy such as X-rays and gamma rays, positrons, electrons, protons, light, and ultrasound for clinical diagnostic and biomedical research applications is just beginning to be realized. The fabrication of a clinically useful cross-section reconstruction device with sensing capabilities for both anatomical structural composition and chemical composition may be possible and awaits future development.

Wood, E. H.↗

The Pinhole/Occulter Facility

A large occulting system in space can be used for high resolution X-ray observations and for large aperture coronagraphic observations in visible and UV light. The X-ray observations can combine high angular resolution in hand (10 keV) X-radiation with the high sensitivity of a multiple pinhole camera, and can permit sensitive observations of bremsstrahlung from nonthermal particles in the corona. The large aperture coronagraphs have two major advantages: high angular resolution and good photon collection. This will permit observations of small scale structures in the corona for the first time and will give sufficient counting rates above the coronal background rates for sensitive diagnostic analysis of intensities and line profiles for coronal structures in the solar wind acceleration region. The technical basis for performing observations with a large occulting system in these three wavelength ranges is described as well as a pinhole/occulter facility presently being considered for Spacelab. Some indications about future developments are included.

Hudson, H. S.↗