Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ion Transport and Crystal Rotation in Plastic Crystal Electrolytes Under Applied Electric Fields

Organic ionic plastic crystal electrolytes, containing a plastic crystal and lithium salt, offer a potential balance between mechanical and electrochemical properties for solid state lithium-ion battery electrolytes. These electrolytes contain multiple mobile ionic species (three or four), resulting in complex transport mechanisms which have not yet been established. Plastic crystals are defined by long-range positional order and short-range rotational disorder. It is therefore necessary to quantify changes in the local crystal structure of the electrolyte as current flows through it. Herein, we examine the electrochemical properties of pyrrolidinium-based plastic crystal electrolytes containing lithium salt and zwitterion additives, including measurements of current fraction and limiting current. We obtain species-specific insight into electrolyte transport using pulsed-field gradient nuclear magnetic resonance spectroscopy and find that, while the zwitterion additive increases ionic conductivity, it decreases lithium diffusivity with respect to other ionic components. With operando spatiotemporally resolved wide-angle X-ray scattering we observe location-specific crystal rotations due to the passage of ionic current. In conclusion, we posit that reducing energy dissipation due to rotation is essential for using plastic crystal electrolytes in practical applications.

Yap, Kyra M. K. [University of California, Berkele↗

Electrochemical testing of metals for petroleum wastewater monitoring

The purpose of this project was to determine the feasibility of ion-selective electrode (ISE) as compared to x-ray fluorescence (XRF) for determining the concentrations of metal ions in petroleum wastewater. ISEs for silver and cadmium were tested in a laboratory under increasingly realistic conditions, then deployed in the sewer wastewater monitoring complex to simulate a petroleum wastewater system. By verifying the ISE calibration after wastewater exposure and comparing its measurements to the XRF systems within the wastewater monitoring system, we determined that the ISE is more sensitive but less feasible for use in live wastewater monitoring due to fouling concerns.

Energy - Petroleum↗

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters↗

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ↗

High Pressure Synthesis of Ultrasmall Nanodiamonds with Nitrogen Vacancy Centers

C–H terminated nanometer scale diamonds ( d = 1 to 15 nm) are synthesized from 1-fluoroadamantane at high pressure (6–8 GPa) and high temperature (500–1500 °C) in a multianvil press. High resolution transmission electron microscopy, X-ray diffraction, Raman, diffuse reflectance Fourier transform infrared, and X-ray absorption spectroscopies demonstrate the excellent crystallinity and atomically flat C–H terminated surfaces of nanodiamonds with (111) and (110) facets. The importance of hydrogen to the synthesis of nanodiamond and its faceting is discussed. Following vacancy generation, annealing and oxidation of the nanodiamonds, optically detected magnetic resonance and electron spin resonance coherence times ( T 2 = 0.9 and 2.1 μs) of nitrogen vacancy (NV) centers are measured. Finally, the obtained T 2 values are equivalent to the shallow NV centers (depth <10 nm) in bulk diamond crystals and larger nanocrystals prepared by mechanical milling.

36 MATERIALS SCIENCE↗

Synthesis, Characterization, and Testing of High-Lithium-Density Composite Breeders

Solid tritium breeder materials must first and foremost have sufficiently high concentrations of lithium to enable a plant-scale tritium breeding ratio greater than 1:1. However, in addition to lithium content, such breeder materials must also meet other performance metrics including high tritium release rates, thermal conductivities, and irradiation damage tolerance. Perhaps most importantly, tritium breeders must maintain their mechanical integrity during reactor operation so as to avoid degradation which can jeopardize the functionality of the tritium breeder blanket module, which in most designs takes the form of a pebble bed geometry. Unfortunately, the mechanical robustness of most lithium-bearing ceramics under investigation for fusion applications is often inversely related to the lithium atom density. For example, a material such as lithium oxide (Li2O), which has one of the highest lithium atom densities, has a much lower mechanical splitting strength than lithium metatitanate (Li2TiO3), though Li2TiO3 has less than half the lithium atom density of Li2O. This work seeks to provide an alternative to monolithic ceramic tritium breeders, in the form of metal-reinforced composite tritium breeders. Specifically, composite tritium breeders have been synthesized combining Li2O with various ferrous metal reinforcements via electric field assisted sintering (EFAS), also known as spark plasma sintering (SPS). As the metal reinforcement content is increased, metallic networks are observed, via electron microscopy and X-ray computed tomography, to form throughout the composite material. Through destructive mechanical testing, even dilute metal reinforcement loading enables drastic mechanical strength improvements over pure Li2O while higher loadings give rise to quasi-ductile behavior and higher ultimate strengths than Li2TiO3 – while still maintaining a higher density of lithium atoms than Li2TiO3 and many other breeder candidates. In addition to microstructural characterization and mechanical testing, thermal property measurements and hydrogen permeability testing are underway to further assess the suitability of such composites for fusion reactor applications.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of the Hubble constant with high-energy neutrinos

Measuring distances in the Universe is one of the hardest problems in physics and astronomy. Almost every distance probe relies on photons, whose propagation across cosmic distances introduces extinction, absorption, scattering, and radiative-transfer effects. Neutrinos suffer none of these and propagate unattenuated through dust, intergalactic medium, and dense source environments alike. We introduce a new distance-ladder method for measuring the Hubble constant $H_0$ using high-energy astrophysical neutrinos from point sources as standardizable candles, and report its first observational realization. Using 12 X-ray-selected Seyfert galaxies for which IceCube reports significant per-source neutrino excesses in its 14-year public point-source release, we exploit the disk-corona correlation $L_ν= κ\, L_X^β$ between neutrino and X-ray luminosities to construct a neutrino distance ladder anchored by non-redshift distances to NGC 1068 (Cepheid + TRGB). We find $H_0 = 49^{+40}_{-30}\,\mathrm{km\,s^{-1}\,Mpc^{-1}}$ and $β= 0.67^{+0.16}_{-0.25}$ (68% credible intervals), with the corona slope disfavoring the calorimetric limit $β= 1$ at ${\sim}2σ$. The result is consistent with existing $H_0$ determinations from Planck and SH0ES within 1$σ$. While the uncertainty on $H_0$ is large, the measurement is free of electromagnetic propagation systematics and demonstrates the viability of neutrinos as a novel cosmographical probe.

Herrera, Gonzalo [MIT, MKI; Harvard U.] (ORCID:000↗

Battery Failure Databank

The Battery Failure Databank contains thermal runaway results gathered from nearly 300 small format fractional thermal runaway calorimetry (S-FTRC) experiments. A majority of these experiments were conducted at synchrotron facilities where high-speed x-ray videography was conducted of the cell while tested inside of the S-FTRC. The databank is a two-component system which consists of a Microsoft ExcelTM spreadsheet which provides S-FTRC results in tabular format and a radiographic video library containing the high-speed x-ray videos. Overall, the databank provides thermal results from S-FTRC experiments conducted on a mixture of commercially available lithium-ion (Li-ion) cells and specialized Li-ion test cells with varying cell format (18650, 21700, and D-cell) and trigger mechanism (heaters, heaters plus internal short circuiting device, and nail penetration). The radiography video component provides insight into the initiation and propagation of TR in the cells, in addition to consequences of TR measured by the FTRC. Fractions of mass ejected for the cell types are separated into regimes based on the different failure modes of the cells, such as purely venting, partial ejection, and total ejection. With knowledge of the rate and characterization of the internal degradation of the cells during TR, and the amounts of mass ejected and unrecovered, the extent of TR, and therefore the mitigation of TR, is revealed relative to cell types and failure modes.

Lithium-ion battery↗

Synthesis and application of thermally responsive nanofiber coatings for overtemperature monitoring

This study presents a one-pot synthesis route to organometallic nanofibers based on copper thiolate, exhibiting distinctive chemical and physical characteristics. Electron microscopy analysis of morphology and composition revealed 2-10 μm-long, 50-90 nm-diameter hollow and non-hollow fibers composed of copper, sulfur, oxygen, hydrocarbon, and chlorine. Thermogravimetric analysis showed a pronounced mass loss within 120°C-135°C. To elucidate the thermal responsive pathways, the nanofibers were characterized before and after heating. X-ray photoelectron spectroscopy indicates that an initially mixed Cu(I)/Cu(II) oxidation states transition to predominantly Cu(I) upon heating. A layer of nanofiber was coated on battery pouch foil and evaluated as a candidate thermally sensitive coating. At elevated temperature (100-130°C), nanofiber coating released volatile organic compounds, sulfide and sulfur dioxide as detected using multiple gas sensors. This thermally responsive gas release/sensing approach provides a potential large-area temperature monitoring strategy, which is particularly relevant where direct temperature measurements of individual batteries is impractical. The results established proof of concept for nanofiber-coated battery pouch foil as overtemperature warning platform that can provide alerts when surface temperatures exceed a critical threshold. More broadly, the ability to form interconnected fiber networks positions copper thiolate nanofiber coatings as promising materials for advanced applications.

Ihala Gamaralalage, Chanaka [ORNL] (ORCID:00000002↗

Metrology for femtosecond pulsed x-ray heating in diamond anvil cell experiments at the European XFEL: Revisiting the iron phase diagram up to 150 GPa

The development of pulsed intense x-ray sources, such as free electron laser, offers new avenues for high pressure experiments. Here, we study the feasibility and metrology of x-ray heating in diamond anvil cells at the European x-ray free electron laser. This method enables one to volumetrically heat the sample while inhibiting chemical migration and probing the crystallographic structure of the sample throughout the heating with a high repetition rate. We focus our study on iron, whose phase diagram is well established up to 100 GPa, to explore the possibilities and limitations of this technique. We volumetrically heat iron samples at starting pressures ranging from 10 to 138 GPa, using the x-ray beam pulsed at 4.5 MHz in a serial pump-and-probe experimental design. Experimental challenges arise from temperature gradients within the sample, changes in temperature at the 100 ns timescale, the difficulty of direct temperature estimates, the effect of thermal pressure, and the presence of metastable crystallites due to rapid cycles of heating and cooling. Hence, we develop a multi-crystal-like data processing method that allows us to account for sample heterogeneity in probed conditions. We then calibrate our measurements using known physical properties of iron under pressure. Thermal pressure in our experiments increases from 4% of the isochoric prediction at 10 GPa to 23% at 138 GPa, and we show that our data are in agreement with most previous observations of iron in this pressure range. The method can now be implemented at higher pressures and temperatures and on materials with unknown phase diagrams.

Materials science↗

Kondo effect in ferromagnetic quantum critical CeRh 6 ⁢Ge 4

The mechanism of a pressure-induced quantum critical point in the heavy fermion ferromagnet CeRh 6 ⁢Ge 4 has attracted interest, as ferromagnetic quantum criticality in a clean itinerant Ce compound is typically avoided. The localized versus itinerant character of the 4⁢𝑓 electrons is a key aspect for understanding this behavior. We investigated the electronic structure of the 4⁢𝑓 shell in CeRh 6 ⁢Ge 4 using core-level photoelectron and x-ray absorption spectroscopy, demonstrating the hybridization of Ce 4⁢𝑓 with the conduction electrons. Linearly polarized x-ray absorption reveals a temperature-dependent linear dichroism consistent with the crystal-electric-field sequence as inferred from the static susceptibility. This dichroism cannot be described by an ionic full-multiplet model alone, but is reproduced by including the Kondo effect within a single-impurity Anderson model in the noncrossing approximation. The Kondo effect mixes higher-lying crystal-field states into a resulting multiorbital ground state with 4⁢𝑓 occupancy, 𝑛 𝑓 ∼ 0.9. Deviations at low temperatures between the measured linear dichroism and calculated dichroism suggest an orbital-dependent Kondo effect. A scenario in which there is a multiorbital ground state and orbital-dependent Kondo hybridization should be a starting point for a model of pressure-induced criticality in CeRh 6 ⁢Ge 4 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anomalous lattice expansion of bcc Ta in helium-loaded diamond anvil cells

Anomalous lattice expansion of bcc Ta is observed in helium-loaded diamond anvil cell (DAC) experiments near 6 GPa and above 400 K, while co-loaded W, Mo, and Au exhibit normal thermal expansion. The Ta volume expansion increases with temperature, reaching ~14% near 650 K before plateauing, and is largely retained after recovery to ambient conditions. Time-resolved measurements at 500 K reveal progressive expansion over several hours, consistent with gradual, thermally activated He incorporation. The largely retained expansion during subsequent cooling and holding at 400 K indicates that the incorporated He is predominantly kinetically trapped. The data reveal two distinct regimes: below ~550 K, modest and spatially uniform expansion consistent with interstitial He trapping at isolated, randomly distributed vacancies; above ~550 K, He-vacancy cluster growth producing dramatically larger expansion, peak broadening, and a core–shell microstructure revealed by micron-resolution X-ray diffraction mapping. These results demonstrate that He is not always a passive pressure medium in DAC experiments and reveal a previously unrecognized regime of He-mediated lattice modification in Ta, complementing conventional ion-implantation studies relevant to nuclear and fusion structural materials.

Diamond anvil cell↗

High Pressure X-ray Diffraction and Equation of State of Hydrazine

Synchrotron X-ray diffraction has been used to investigate the structure and equation of state (EOS) of hydrazine (N 2 H 4 ) up to 54.3 GPa at 298 K. The diffraction patterns could be fit to a monoclinic unit-cell structure and put strong constraints on previously reported phase transitions documented by vibrational spectroscopy over this pressure range. Pressure–volume ( P–V ) data were fit using a Vinet EOS, yielding parameters: V 0 = 45.2 Å 3 /molecule (fixed), K 0 = 11.8(7) GPa, and K 0 ′ = 6.5(2). Previously measured high-pressure vibrational frequency shifts were used to estimate the vibrational free energy and model P–V–T isotherms from 0 to 1200 K. The results of the P–V–T isotherms are compared to existing shock Hugoniot data on hydrazine and 298 K isotherms for assemblages of possible decomposition products. This comparison suggests dissociation at high density under shock loading. Good correspondence was found between the static lattice EOS as calculated by the model and the previously reported EOS as calculated by density functional theory. Finally, these results resolve existing uncertainties about the EOS and crystal symmetry of hydrazine at high pressure and provide valuable baseline information on this important energetic material.

diffraction↗

Epitaxial registry and transport properties in V4O7 thin films

We report the growth of V4O7 thin films deposited simultaneously on amorphous SiO2 and crystalline c-cut Al2O3 substrates. x-ray diffraction shows that films grown on SiO2 are polycrystalline with no preferred orientation, while films grown on Al2O3 exhibit a well-defined out-of-plane orientation and an in-plane registry consistent with epitaxial growth. Transmission electron microscopy confirms the crystallographic relationship between the V4O7 film and the Al2O3 substrate. Atomic force microscopy indicates substantially lower surface roughness for films grown on Al2O3 (~6 nm) compared to those grown on SiO2 (~22 nm), and Raman spectroscopy confirms stabilization of the same V4O7 phase on both substrates. Electrical transport measurements reveal a metal–insulator transition near 244 K for both substrates, with thermal hysteresis not exceeding ~1 K. Although the transition temperature remains essentially unchanged, films grown on Al2O3 exhibit higher conductivity over the entire temperature range, exceeding that of films grown on SiO2 by approximately two orders of magnitude at 100 K and by a factor of five at 300 K. These results indicate that the conductivity differences are consistent with variations in microstructural connectivity associated with crystallographic order.

36 MATERIALS SCIENCE↗

Establishing the Stability of Cross-Linked Poly(ethylene oxide) Blended with Poly(pentyl malonate) against Lithium Metal Anodes

This work focuses on an electrolyte obtained by infusing linear poly(pentyl malonate) (PPM) chains into cross-linked poly(ethylene oxide) (PEO). A lithium salt is added to enable ion transport. Obtaining this electrolyte is only possible because PPM is miscible with PEO irrespective of salt concentration. The properties of this electrolyte are compared against two benchmarks: an electrolyte obtained by infusing linear PEO into cross-linked PEO and cross-linked PEO with no added linear polymer. Measurements of storage moduli and ion transport efficacies are found to be similar across the three electrolytes, suggesting similar stability behavior against lithium metal anodes, based on current theoretical models. Instead, the PPM infused electrolyte outperforms the other two electrolytes. In the cycling tests, the current supported by the PPM infused electrolyte was a factor of 20 higher than that of the PEO infused electrolyte and a factor of 4 higher than that of the cross-linked PEO electrolyte. In the unidirectional plating experiments, the other two electrolytes fail after about 4 h or less, while the PPM containing electrolyte did not fail during the 140 h testing period. Insight into the nature of failure modes was obtained using synchrotron hard X-ray microtomography.

Gido, Lily [University of California, Berkeley]↗

Electron-Deficient Phenazines: Synthesis, Structures, Redox, and Optoelectronic Properties in the Gas Phase, in Solution, and in the Solid State

High-temperature gas-phase reactions of 1,4-C4F8I2 with phenazine (PHNZ) afforded new thermally- and air-stable derivatives with cyclo-C4F8 substituents, viz. 1,2-PHNZ(C4F8), 2,3-PHNZ(C4F8), 1,2:6,7-PHNZ(C4F8)2, 1,2:7,8-PHNZ(C4F8)2, and 1,2:8,9-PHNZ(C4F8)2. Reactions in the presence of Cu powder resulted in reductive-defluorination/aromatization of some of the cyclo-C4F8 substituents to produce 2,3-PHNZ(C4F4), 2,3-PHNZ(C4HF3), and 1,2:6,7-PHNZ(C4F8)(C4F4), which are formally tri- or tetrafluoro derivatives of benzo[a]phenazine. Single-crystal X-ray diffraction structures of these compounds demonstrate the planarity of 2,3-PHNZ(C4F4) and 2,3-PHNZ(C4HF3) and ordered p-stacking in 1,2-PHNZ(C4HF3), 1,2-PHNZ(C4F4), 1,2-PHNZ(C4F8), and 2,3-PHNZ(C4F8). Low-temperature gas-phase photoelectron spectra of the PHNZ(C4F8)1,2 compounds show that they are strong electron acceptors, with the three PHNZ(C4F8)2 isomers having electron affinities exceeding that of C60. Cyclic voltammetry in acetonitrile show that the five PHNZ(C4F8)1,2 compounds exhibit reversible one-electron reductions with large positive shifts in their reduction potentials relative to unsubstituted PHNZ. Spectroelectrochemical absorption and EPR spectra of PHNZ(C4F8)1,2- • anion radicals and extensive DFT calculations revealed the significant role that the different substitution patterns have on determining the optoelectronic properties of the PHNZ(C4F8)1,2 derivatives and PHNZ(C4F8)1,2- • anion radicals. Time-resolved microwave conductivity measurements and photoluminescence spectra of blends of the PHNZ(C4F8)1,2 derivatives with the donor poly(3-hexylthiophene) (P3HT) were recorded to assess the possible use of the new compounds in optoelectronic devices.

Balser, Sebastian↗

Electron–Ion Covariance Reveals Geometry-Resolved Inner-Shell Spectra in CS 2 Photodissociation

The chemical shifts of inner-shell atomic orbitals are highly sensitive to chemical bonding and molecular structure. In evolving systems, however, the spectra of distinct molecular species and geometries overlap, obscuring the underlying chemical dynamics. Here we demonstrate the use of electron–ion covariance analysis to combine the structural sensitivity of Coulomb explosion imaging with inner-shell spectroscopy, yielding geometry-specific spectra of transient and product species. We apply this approach to the excited state dynamics of CS 2 probed by ionization above the S 2p edge. Electron–ion covariance with time- and momentum-selected S + and S 2+ ions isolates distinct S 2p photoelectron spectra for ground-state CS 2 , bent photoexcited CS 2 , the CS photoproduct, and bare atomic sulfur ─ species whose spectra overlap strongly in the channel-averaged measurement. Clear chemical shifts are observed in the covariance photoelectron spectrum for each of these species, all of which are consistent with high-level calculations. Here, by extracting the atomic S contribution to the photoelectron spectrum in a finely time-resolved manner we can disentangle this contribution to the overall time-resolved photoelectron spectrum as the photodissociation proceeds. These results demonstrate the promise of electron–ion covariance as a general approach to geometry-resolved inner-shell spectroscopy, opening a route to tracking structural evolution through chemical shifts in complex photoexcited molecules.

Ionization↗

Structural and spectroscopic characterization of a Tb(IV) polyoxometalate

There has been a renaissance in high valent lanthanide chemistry, which has resulted in the first examples of tetravalent praseodymium (Pr) and terbium (Tb) in molecular systems. These feats have been achieved with tailored ligands that facilitate tetravalent lanthanide stability in non-aqueous conditions. The next step in realizing the potential of high valent lanthanide chemistry is moving towards complexes that are stable in ambient and aqueous conditions. In this investigation, we advance this paradigm by obtaining definitive evidence of Tb(IV) in a molecular system under aqueous conditions utilizing the lacunary Wells-Dawson polyoxometalate, K 10 P 2 W 17 O 61 •20H 2 O. Herein we present the single crystal structure of K 16 Tb(IV)(P 2 W 17 O 61 ) 2 •39.85H 2 O (Tb(IV)W 34 ) as well as extensive spectroscopic evidence obtained via UV–Vis-NIR, X-ray absorption near edge spectroscopy, continuous wave X-band electron paramagnetic resonance spectroscopy and SQUID magnetometry measurements to confirm the oxidation state of Tb in W 34 complexes as +4.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗