Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Low blaze angle grating for fully dispersive x-ray spectroscopy

We demonstrate fabrication of an ultra-low blaze angle (LBA) grating designed for time-resolved spectroscopy in the x-ray region. A blaze angle of 0.12° was achieved by the groove depth reduction process providing a perfect saw-tooth shape of the grooves. The 200 lines/mm LBA grating exhibited high diffraction efficiency at a photon energy of 8 KeV. Use in a spectrometer would open up dispersive x-ray absorption spectroscopy across a wide energy range including the K edges of 3d transition metals, with much greater efficiency than traditional crystal spectrometers.

Voronov, D. L.↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Instrumentation and Samples (CRADA Final Report)

Instruments which are categorized as shared user instruments at the National Laboratory of the Rockies (NLR) will be utilized for ongoing technical work. Samples will be provided by University of Colorado Boulder (CU) and thus no need for materials at NLR is anticipated.

(Ga1- xZnx)(N1-xOx)↗

Physics of Ultra-High Energy Density Relativistic Plasmas from Ordered Nanostructures

This award funded a four-year program at Colorado State University on the physics of ultra-high energy density plasmas generated by focusing femtosecond, >1021 Wcm-2 laser pulses onto ordered nanowire arrays. We used the ALEPH petawatt-class Ti:Sa laser with its high contrast 400 nm second harmonic beamline to irradiate arrays of Ni and TiO2 nanowires made by template assisted electrodeposition and atomic layer deposition over a wide range of average densities. We met two of the three original project goals: radial ion acceleration via doppler shifted K shell emission, and time and spectrally resolved K shell measurements. The main experimental advance was integrating the Lawrence Livermore National Laboratory (LLNL) TREX ultrafast x-ray streak camera with a suite of spherically bent quartz Bragg crystal spectrometers built using Princeton Plasma Physics Laboratory (PPPL) methodology. This is the first TREX-on-bent-quartz setup fielded at a femtosecond, >1021 Wcm-2 facility. It is now a permanent diagnostic at ALEPH and is offered to the LaserNetUS user community. The program produced three peer reviewed journal articles that acknowledge this award. The platform will continue at the upgraded CSU ATLAS facility, where the ALEPH laser is being upgraded to 2 PW.

Hollinger, Reed [Colorado State University]↗

Oxygen Opacity Measurements at High-Energy-Density Conditions

We present the first benchmark measurements of oxygen opacity at high-energy-density, crucial for understanding stellar interiors. A 3–5−μm thick SiO 2 sample was heated using a Z facility x-ray source, and opacity was measured in the 5–19.5 Å range with multiple spectrometers. The electron temperature and density inferred from Si 𝐾-shell spectra were 148 ± 4 eV and 8.6 ±1.4 × 10 21 cm −3 , respectively. Six experiments showed opacity reproducibility within ±15% and 5%–25% opacity uncertainty. Measured oxygen opacity and seven different opacity models exhibit extraordinary overall agreement. Discrepancies near the H-like photon ionization threshold and in certain spectral lines suggest the need for model refinements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

XAFS Analysis Report

X-ray absorption spectroscopy (XAS) measurements were performed using a laboratory-based easyXAFS 300+ spectrometer. The XAFS data shows predominantly metallic phases.

42 - ENGINEERING↗

Spectral line identification from a photoionised silicon plasma in emission

Next-generation X-ray satellite telescopes such as XRISM, NewAthena and Lynx will enable observations of exotic astrophysical sources at unprecedented spectral and spatial resolution. Proper interpretation of these data demands that the accuracy of the models is at least within the uncertainty of the observations. One set of quantities that might not currently meet this requirement is transition energies of various astrophysically relevant ions. Current databases are populated with many untested theoretical calculations. Accurate laboratory benchmarks are required to better understand the coming data. We obtained laboratory spectra of X-ray lines from a silicon plasma at an average spectral resolving power of ∼7500 with a spherically bent crystal spectrometer on the Z facility at Sandia National Laboratories. Many of the lines in the data are measured here for the first time. We report measurements of 53 transitions originating from the K-shells of He-like to B-like silicon in the energy range between ∼1795 and 1880 eV (6.6–6.9 Å). The lines were identified by qualitative comparison against a full synthetic spectrum calculated with ATOMIC. The average fractional uncertainty (uncertainty/energy) for all reported lines is ∼5.4 × 10 −5 . We compare the measured quantities against transition energies calculated with RATS and FAC as well as those reported in the NIST ASD and XSTAR’s uaDB. Average absolute differences relative to experimentally measured values are 0.20, 0.32, 0.17 and 0.38 eV, respectively. All calculations/databases show good agreement with the experimental values; NIST ASD shows the closest match overall.

astrophysical plasmas↗

Structured ionized winds shooting out from a quasar at relativistic speeds

Evidence indicates that supermassive black holes (SMBHs) exist at the centres of most galaxies. Their mass correlates with the galactic bulge mass, suggesting a coevolution with their host galaxies, most likely through powerful winds. X-ray observations have detected highly ionized winds outflowing at sub-relativistic speeds from the accretion disks around SMBHs. However, the limited spectral resolution of present X-ray instruments has left the physical structure and location of the winds poorly understood, hindering accurate estimates of their kinetic power. Here, in this study, the first X-Ray Imaging and Spectroscopy Mission (XRISM) observation of the luminous quasar PDS 456 is reported. The high-resolution spectrometer Resolve aboard XRISM enabled the discovery of five discrete velocity components outflowing at 20–30% of the speed of light. This demonstrates that the wind structure is highly inhomogeneous, which probably consists of up to a million clumps. The mass outflow rate is estimated to be 60–300 solar masses per year, with the wind kinetic power exceeding the Eddington luminosity limit. Compared with the galaxy-scale outflows, the kinetic power is more than three orders of magnitude larger, whereas the momentum flux is ten times larger. These estimates disfavour both energy-driven and momentum-driven outflow models. This suggests that such wind activity occurs in less than 10% of the quasar phase and/or that its energy/momentum is not efficiently transferred to the galaxy-scale outflows owing to the clumpiness of the wind and the interstellar medium.

Audard, Marc [Univ. of Geneva, Versoix (Switzerlan↗

X-Ray and Particle Detection With the Si(Li) Tracker Module of the GAPS Experiment

Here, this work describes the architecture and the experimental results from the characterization of the lithium-drifted silicon (Si(Li)) detector module, which constitutes the building block of the tracker in the general antiparticle spectrometer (GAPS) experiment to search for dark matter. The instrument is designed for the identification of low-energy cosmic anti-nuclei (antiprotons, antideuterons, and antihelium) to be performed during an Antarctic long-duration balloon flight scheduled for late 2025. The GAPS Si(Li) tracker, that is the core of the instrument, is the assembly of 252 modules, each comprised of four Si(Li) detectors and a full custom-integrated circuit designed for detector readout and produced in a commercial 180-nm planar CMOS technology. A general overview of the detector module architecture and its components is provided, together with a description of the test setup and the experimental results obtained from the characterization of the low-noise analog readout channel. In order to verify the effective operation of the entire module, results concerning the detection of X-rays from a 241Am source and cosmic muons are also provided.

Manghisoni, Massimo [Università di Bergamo (Italy)↗

Solvation Structure of 237 Np 4+ in a Noncomplexing Environment

Here, the solvation structure of an Np 4+ ion in an aqueous, noncomplexing and nonoxidizing environment of trifluoromethanesulfonic (triflic) acid was investigated with X-ray absorption spectroscopy (XAS) combined with ab initio molecular dynamics (AIMD) and time-dependent density functional theory (TDDFT) calculations. Np L III -edge X-ray absorption near-edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) data were collected for Np 4+ in 1, 3, and 7 M triflic acid using a laboratory-scale spectrometer and separately at a synchrotron facility, producing data sets in excellent agreement. TDDFT calculations revealed a weak pre-edge feature not previously reported for Np L III -edge XANES. AIMD modeling results showed differences in the hydration shell of the Np 4+ ion at different concentrations of triflic acid; these results are supported by the experiment. EXAFS fit models to the experiment resulted in similar coordination of Np 4+ in noncomplexing aqueous media as reported in the literature for 1 M perchloric acid but, together with calculations, revealed more than one distance between Np and O atoms in 7 M triflic acid. These results imply monodentate coordination with sulfonate groups in 7 M triflic acid and suggest the possibility of proto-neptunyl species in relatively low-concentration Np 4+ acid solutions.

Boglaienko, Daria V. [Pacific Northwest National L↗

Autonomous Infrared and Small (Wide) Angle X-Ray Scattering (IR-S(W)AXS) Capability

Thin water films are 2-D, nanoconfined layers that form on solid surfaces exposed to humid atmospheres—environments ubiquitous across catalysis, corrosion science, soil science, and subsurface geochemistry. At relative humidity (RH) values below saturation, these films are Å–nm thick and exhibit properties that differ sharply from bulk water, including disrupted H-bonding and impeded mass transport. Owing to their high surface-to-volume ratio, dissolution of the solid can rapidly drive strong supersaturation with respect to secondary phases. Reactivity in thin water films is highly sensitive to film thickness, and critically, thickness evolves during reaction because the hygroscopicity of the interfacial system changes as ions accumulate or diminish in the film and as reaction products transform. To accurately probe and control these dynamics, a capability is needed that can measure and automatically maintain a constant water-film thickness while simultaneously monitoring solid dissolution, nucleation, and growth. This project developed an autonomous Infrared/Small Angle X-ray Scattering-Wide Angle X-ray Scattering (IR/(W)SAXS) for investigating reactivity in thin water films on solid surfaces exposed to humidified gases. The capability consists of an IR spectrometer, a (W)SAXS instrument, and a mass flow controller system for generating variably humidified gas flows to a custom reaction cell. Progress on each of the major components of the capability are detailed below.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Supporting Data for "Constraints on magnetism and correlations in RuO2 from lattice dynamics and Mössbauer spectroscopy"

Contents of this DOI are data for the research paper "Constraints on magnetism and correlations in RuO2 from lattice dynamics and Mossbauer spectroscopy" by the authors: George Yumnam, et. al. The dataset contains data from inelastic x-ray scattering measurements of RuO2 single crystals performed at the Advanced Photon Source in Argonne National Lab. This dataset also contains data from inelastic neutron scattering experiments of RuO2 powder performed at the ARCS spectrometer at Spallation Neutron Source at ORNL. Supporting theoretical calculations based on density functional theory with r2SCAN and DFT+U methods is also included in this dataset. Please see the README.txt files for more information of the dataset and file contents. For comments and questions, please contact: George Yumnam (yumnamg@ornl.gov) and/or Raphael P Hermann (hermannrp@ornl.gov)

density functional theory↗

The meV-resolved Inelastic X-ray Scattering Beamline at NSLS-II: Design and Performance

The ultrahigh resolution inelastic X-ray scattering (IXS) beamline at NSLS-II is designed and built to achieve sub-meV resolution at a moderate energy of 9.13 keV for IXS experiments with high momentum resolution and high spectral contrast. The key instrument is a novel spectrometer featuring a new type of analyzer optics, which combines post-sample collimation with angular dispersive crystal optics. As the first user instrument of its kind, the spectrometer has demonstrated unique research capabilities in exploring low momentum transfer (Q), THz dynamics in soft material systems characterized by mesoscopic heterogeneity and complexity, such as liquid crystals and bio-membranes. Ongoing efforts to improve performance since the start of user operations have resulted in a state-of-the-art energy resolution in routine operations of less than 1.4 meV, with sharp Gaussian-like tails, making it a premier IXS spectrometer for studying the dynamics of soft materials, while also delivering competitive performance for investigating phonon dynamics in hard condensed matter systems, including a broad range of quantum materials.

43 PARTICLE ACCELERATORS↗

Phosphate Textural Diversity in CI Chondrites and C-Type Asteroids

Introduction: Apatite, Ca 5 (PO 4 ) 3 (CL/F/OH-), is a ubiquitous phosphate found throughout the solar system, including the most primitive solids, CI-chondrites [1,2] and related samples of carbonaceous asteroids Ryugu [3] and Bennu [4], returned by JAXA’s Hayabusa2 and NASA’s OSIRIS-REx missions, respectively. Apatite in these primitive solids is found as individual grains or mineral clusters and has been inferred to form from the hydrothermal sequence during cooling of their respective parent body or bodies. To better understand the formation history and reworking of these early phosphates we have undertaken a highly coordinated study of phosphate microstructures, geochemistry and U/Pb geochronology from a suite of CI meteorites and carbonaceous asteroid samples. These data have identified novel phosphate microstructures and complex relationships across a suite of apatite grains from the early solar system, indicating multiple episodes of growth and modification on the CI parent body(ies). Methods: Samples of CI chondrites, Alais, Ivuna, Orgueil, Oued Chebeika 002, Yamato (Y) 82162, Y980115, Y980134, and two chips of Hayabusa2 Ryugu particles (A0262 and C0263) have been acquired for analysis. The bulk texture of the samples were first scanned by X-ray Computed Tomography (XCT) using the Nikon XT H 320 within the XFACT facility at NASA JSC or the Xradia 620 Versa at the UTCT facility. Based on the identification of petrofabrics or features of interest from the XCT data, samples were chipped, oriented, potted in epoxy and thick sections were prepared. After anhydrously polishing the samples with silicon carbide and dry diamond powder down to 1 µm, the samples were ion polished using a Hitachi ArBlade. Energy dispersive Xray spectrometry (EDS) maps were collected to ID phosphates of interest using a JEOL 7900F SEM. The internal microstructures of identified phosphates were then mapped by electron backscatter diffraction (EBSD) using the JEOL 7900F. Based on the EDS and EBSD data, domains of interest were targeted for quantitative chemical analyses using a JEOL 8530 EPMA. Subsequently, in situ U-Pb and 207 Pb/ 206 Pb ages will be collected using a Cameca ims1290 secondary ion mass spectrometer at UCLA across a range of microstructures. Results: Apatite grains are ubiquitous throughout the CI chondrites and carbonaceous asteroid materials, found as individual grains, disseminated clusters or grain aggregates. Apatite grains are associated with serpentine, magnet-ite, and/or carbonate. Of particular interest, we have identified individual and aggregate polycrystalline grains ex-hibiting an internal ‘honeycomb’ texture (Fig. 1). Some of these grains appear overprinted by subsequent alteration while others remain unaltered. Apatite halogen sites are dominated by the missing component, assumed to be OH, and F, comparable to published values from Bennu, Ryugu and CM-chondrites [3-5]. However, the Yamato CI-like meteorites show a broader range of Cl values, and one grain from Alais is dominated by CL. Summary: Apatite growth features indicate a protracted and complex growth history, consistent with precipitation from an evolving fluid system. The ‘honeycomb’ texture identified in some CI meteorites is, to the best of our knowledge, the first report of such a microstructure in meteoritic phosphate. The microtextures and zoning will guide subsequent age analyses, to better constrain the formation and reworking of phosphate in CI(-like) materials. Acknowledgments: We thank the National Institute of Polar Research, Japan for samples of Y82162, 980115 and 980134 meteorites, ASU’s Buseck Center for Meteorite Studies for samples of Ivuna and Alais meteorites, and JAXA curation for chips of Ryugu material. This work was funded by NASA ROSES LARS grant 24-LARS24-0014. References: [1] Morlok et al., 2016, GCA 70:5371-5394. [2] Alfin g et al., 2019, Geochemistry 79:125532. [3] Nakamura et al. (2022) Science 379:1-15. [4] Seifert et al. (2026) MAPS 61:504-521. [5] Piralla et al. (2021) MAPS 56:809-828.

CI chondrites↗

Spectral deconvolution without the deconvolution: Extracting temperature from x-ray Thomson scattering spectra without the source-and-instrument function

X-ray Thomson scattering (XRTS) probes the dynamic structure factor of the system, but the measured spectrum is broadened by the combined source-and-instrument function (SIF) of the setup. In order to extract properties such as temperature from an XRTS spectrum, the broadening by the SIF needs to be removed. Recent work [Dornheim et al. Nat. Commun. 13 , 7911 (2022)] has suggested that the SIF may be deconvolved using the two-sided Laplace transform. However, the extracted information can depend strongly on the shape of the input SIF, and the SIF is in practice challenging to measure accurately. Here, we propose an alternative approach: we demonstrate that considering ratios of Laplace-transformed XRTS spectra collected at different scattering angles is equivalent to performing the deconvolution, but without the need for explicit knowledge of the SIF. From these ratios, it is possible to directly extract the temperature from the scattering spectra, when the system is in thermal equilibrium. We find the method to be generally robust to spectral noise and physical differences between the spectrometers, and we explore situations in which the method breaks down. Furthermore, the fact that consistent temperatures can be extracted for systems in thermal equilibrium indicates that non-equilibrium effects could be identified by inconsistent temperatures of a few eV between the ratios of three or more scattering angles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

X-ray escape peaks in gamma-ray spectrum acquired by perovskite detector

The X-ray escape peaks are clearly visible in the high-resolution gamma spectra acquired by CsPbBr 3 , credit to the rapidly improving energy resolution of perovskite gamma detectors. But it also raises concerns. If this peak remains as significant as it is, perovskite gamma detectors would have very limited use in complex gamma spectrometry applications. This paper discusses the origin of the escape peaks in CsPbBr 3 detectors, benchmarked against Ge and CZT detectors. The Pb escape peak consists of four escape peaks that are merged together, while the Cs and Br escape peaks are hidden inside the photopeak of 137 Cs (662 keV). These combined effects either create a noticeable gamma peak observed to the left of the 662 keV photopeak when acquired using a high-resolution CsPbBr 3 detector or raise the left slope of the photopeak. We also explore potential methods to mitigate these peaks, such as applying anti-coincidence method. The height of the escape peaks diminishes as the detector volume increases but will not go away entirely. The relationship between the observed Pb escape peak and the detector's dimensions is demonstrated through Monte Carlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗