Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Shape evolution of Eu-doped Bi{sub 2}WO{sub 6} and their photocatalytic properties

Highlights: • Hydrothermal synthesis of Eu-doped Bi{sub 2}WO{sub 6} micro/nanostructure without any additives. • Dopant and doping level affect the shape evolution and photocatalytic activities. • Eu-doped Bi{sub 2}WO{sub 6} exhibit superior photocatalytic activity in degradation of RhB. - Abstract: Europium-doped bismuth tungstate (Eu-doped Bi{sub 2}WO{sub 6}) was synthesized via hydrothermal method. The composition, structure, and microstructure of the products were characterized by X-ray diffraction and scanning electron microscopy. Depending on the doping level, nanoflakes and 3D hierarchical microspheres were formed. The photocatalytic activities of all products obtained were evaluated by the degradation of Rhodamine-B under visible light irradiation. A substantially improved photocatalytic performance of Eu-doped Bi{sub 2}WO{sub 6} is achieved. This study demonstrates a simple method that could produce stable photocatalysts with greatly enhanced performance.

36 MATERIALS SCIENCE↗

Technical Note: Radiological properties of tissue surrogates used in a multimodality deformable pelvic phantom for MR-guided radiotherapy

Purpose: Phantom surrogates were developed to allow multimodal [computed tomography (CT), magnetic resonance imaging (MRI), and teletherapy] and anthropomorphic tissue simulation as well as materials and methods to construct deformable organ shapes and anthropomorphic bone models. Methods: Agarose gels of variable concentrations and loadings were investigated to simulate various soft tissue types. Oils, fats, and Vaseline were investigated as surrogates for adipose tissue and bone marrow. Anthropomorphic shapes of bone and organs were realized using 3D-printing techniques based on segmentations of patient CT-scans. All materials were characterized in dual energy CT and MRI to adapt CT numbers, electron density, effective atomic number, as well as T1- and T2-relaxation times to patient and literature values. Results: Soft tissue simulation could be achieved with agarose gels in combination with a gadolinium-based contrast agent and NaF to simulate muscle, prostate, and tumor tissues. Vegetable oils were shown to be a good representation for adipose tissue in all modalities. Inner bone was realized using a mixture of Vaseline and K{sub 2}HPO{sub 4}, resulting in both a fatty bone marrow signal in MRI and inhomogeneous areas of low and high attenuation in CT. The high attenuation of outer bone was additionally adapted by applying gypsum bandages to the 3D-printed hollow bone case with values up to 1200 HU. Deformable hollow organs were manufactured using silicone. Signal loss in the MR images based on the conductivity of the gels needs to be further investigated. Conclusions: The presented surrogates and techniques allow the customized construction of multimodality, anthropomorphic, and deformable phantoms as exemplarily shown for a pelvic phantom, which is intended to study adaptive treatment scenarios in MR-guided radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Graphene-Polypyrrole Nanocomposite as a Highly Efficient and Low Cost Electrically Switched Ion Exchanger for Removing ClO4- from Wastewater

Perchlorate (ClO4-) contamination is now recognized as a widespread concern affecting many water utilities. In this report, graphene is employed as the scaffold to synthesize novel graphene-polypyrrole nanocomposite, which is demonstrated as excellent electrically switched ion exchanger for perchlorate removal. Scanning electron microscopy (SEM) and electrochemical measurements showed that the 3D nanostructured graphene/Ppy nanocomposite exhibited the significantly improved uptake capacity for ClO4- compared with Ppy film. X-ray photoelectron spectroscopy (XPS) confirmed the uptake and release process of ClO4- in graphene/Ppy nanocomposite. In addition, the presence of graphene substrate resulted in high stability of graphene/Ppy nanocomposite during potential cycling. The present work provides a promising method for large scale water treatment.

36 MATERIALS SCIENCE↗

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

Exchange-correlation functional challenges in modeling quaternary chalcogenides

The development of next-generation quaternary chalcogenides, such as Cu2ZnSnS4 (CZTS) and Cu2ZnGeS4 (CZGS), for solar energy and thermoelectric applications hinges upon both careful experimentation and accurate quantum mechanical modeling. To address the latter, many have turned to density functional theory (DFT), which offers several choices for the approximate treatment of electron exchange and correlation (XC). Popular XC functionals include the Perdew-Burke-Ernzerhof (PBE) generalized gradient approximation (GGA) and the recently developed strongly constrained and appropriately normed (SCAN) meta-GGA. Extensions of DFT functionals, such as adding a Hubbard U correction and introducing a fraction of the Fock exchange (hybrid functionals), have been used widely to model systems containing 3d metal ions. However, no studies yet have compared comprehensively PBE(+U) and SCAN(+U) in the quality of their predictions of the bulk and defect thermodynamics of quaternary chalcogenides, which play a critical role in device fabrication and performance. Hence, here we calculate the (i) 0 K formation energies of bulk Ge compounds and (ii) neutral defect formation energies including charge-balanced (e.g., CuZn + ZnCu) and charge-imbalanced (e.g., CuSn) combinations of antisites and vacancies in CZTS and CZGS using the PBE, PBE +U, SCAN, SCAN +U, and the hybrid Heyd-Scuseria-Ernzerhof XC frameworks. We find that the formation energies of charge-imbalanced defects are more sensitive to the choice of the XC functional than those of charge-balanced defects, which can be explained by the differences in the extent of penalization of defect-generated delocalized electrons/holes by PBE, PBE +U, SCAN, and SCAN +U. Additionally, our results show that SCAN systematically underbinds Ge-containing compounds, thus highlighting the need for even further improvement of XC functionals. Based on our findings, we recommend the use of SCAN for modeling quaternary chalcogenides because its errors are systematic, and it has the firmest theoretical underpinning. Our work provides guidance for future modeling of quaternary chalcogenides.

14 SOLAR ENERGY↗

High-resolution 3D microwave imaging using an optically tracked linear array

Active three-dimensional microwave or millimeter-wave imaging is typically performed using a linear array that is mechanically scanned over a uniform planar or cylindrical aperture. However, an image can also be formed with a linear array that is scanned over a non-uniform irregular aperture. This requires that the precise position of the array be known for each radar sample. This paper explores high-resolution 3D microwave imaging of stationary targets using an optically tracked manually scanned linear array. The image reconstruction techniques necessary to account for a non-uniform irregular aperture are also developed.

Clark, Richard T.↗

3D strain field reconstruction by inversion of dynamical scattering

Strain governs not only the mechanical response of materials but also their electronic, optical, and catalytic properties. For this reason, the measurement of the 3D strain field is crucial for a detailed understanding and for further development of material properties through strain engineering. However, measuring strain variations along the electron beam direction has remained a major challenge for (scanning-) transmission electron microscopy (S/TEM). In this article, we present a method for 3D strain field determination using 4D-STEM. The method is based on the inversion of dynamical diffraction effects, which occur at strain field variations along the beam direction. We test the method against simulated data with a known ground truth and demonstrate its application to an experimental 4D-STEM dataset from an inclined pseudomorphically grown Al0.47Ga0.53N layer.

Niermann, Laura↗

Three dimensional simulations of plasma filaments in the scrape off layer: A comparison with models of reduced dimensionality

This paper presents simulations of isolated 3D filaments in a slab geometry obtained using a newly developed 3D reduced fluid code, written using the BOUT++ framework. First, systematic scans were performed to investigate how the dynamics of a filament are affected by its amplitude, perpendicular size, and parallel extent. The perpendicular size of the filament was found to have a strong influence on its motions, as it determined the relative importance of parallel currents to polarization and viscous currents, whilst drift-wave instabilities were observed if the initial amplitude of the blob was increased sufficiently. Next, the 3D simulations were compared to 2D simulations using different parallel closures; namely, the sheath dissipation closure, which neglects parallel gradients, and the vorticity advection closure, which neglects the influence of parallel currents. The vorticity advection closure was found to not replicate the 3D perpendicular dynamics and overestimated the initial radial acceleration of all the filaments studied. In contrast, a more satisfactory comparison with the sheath dissipation closure was obtained, even in the presence of significant parallel gradients, where the closure is no longer valid. Specifically, it captured the contrasting dynamics of filaments with different perpendicular sizes that were observed in the 3D simulations which the vorticity advection closure failed to replicate. However, neither closure successfully replicated the Boltzmann spinning effects nor the associated poloidal drift of the blob that was observed in the 3D simulations. Although the sheath dissipation closure was concluded to be more successful in replicating the 3D dynamics, it is emphasized that the vorticity advection closure may still be relevant for situations where the parallel current is inhibited from closing through the sheath due to effects such as strong magnetic shear around X points or increased resistivity near the targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation

This study introduces a charge coupled device (CCD) area detector based optical-computed tomography (optical-CT) scanner for comprehensive verification of radiation dose distributions recorded in nonscattering radiochromic dosimeters. Defining characteristics include: (i) a very fast scanning time of {approx}5 min to acquire a complete three-dimensional (3D) dataset, (ii) improved image formation through the use of custom telecentric optics, which ensures accurate projection images and minimizes artifacts from scattered and stray-light sources, and (iii) high resolution (potentially 50 {mu}m) isotropic 3D dose readout. The performance of the CCD scanner for 3D dose readout was evaluated by comparison with independent 3D readout from the single laser beam OCTOPUS-scanner for the same PRESAGE dosimeters. The OCTOPUS scanner was considered the 'gold standard' technique in light of prior studies demonstrating its accuracy. Additional comparisons were made against calculated dose distributions from the ECLIPSE treatment-planning system. Dose readout for the following treatments were investigated: (i) a single rectangular beam irradiation to investigate small field and very steep dose gradient dosimetry away from edge effects, (ii) a 2-field open beam parallel-opposed irradiation to investigate dosimetry along steep dose gradients, and (iii) a 7-field intensity modulated radiation therapy (IMRT) irradiation to investigate dosimetry for complex treatment delivery involving modulation of fluence and for dosimetry along moderate dose gradients. Dose profiles, dose-difference plots, and gamma maps were employed to evaluate quantitative estimates of agreement between independently measured and calculated dose distributions. Results indicated that dose readout from the CCD scanner was in agreement with independent gold-standard readout from the OCTOPUS-scanner as well as the calculated ECLIPSE dose distribution for all treatments, except in regions within a few millimeters of the edge of the dosimeter, where edge artifact is predominant. Agreement of line profiles was observed, even along steep dose gradients. Dose difference plots indicated that the CCD scanner dose readout differed from the OCTOPUSscanner readout and ECLIPSE calculations by {approx}10% along steep dose gradients and by {approx}5% along moderate dose gradients. Gamma maps (3% dose-difference and 3 mm distance-to-agreement acceptance criteria) revealed agreement, except for regions within 5 mm of the edge of the dosimeter where the edge artifact occurs. In summary, the data demonstrate feasibility of using the fast, high-resolution CCD scanner for comprehensive 3D dosimetry in all applications, except where dose readout is required close to the edges of the dosimeter. Further work is ongoing to reduce this artifact.

61 RADIATION PROTECTION AND DOSIMETRY↗

A hard x-ray nanoprobe for scanning and projection nanotomography

To fabricate and qualify nanodevices, characterization tools must be developed to provide a large panel of information over spatial scales spanning from the millimeter down to the nanometer. Synchrotron x-ray-based tomography techniques are getting increasing interest since they can provide fully three-dimensional (3D) images of morphology, elemental distribution, and crystallinity of a sample. Here we show that by combining suitable scanning schemes together with high brilliance x-ray nanobeams, such multispectral 3D volumes can be obtained during a single analysis in a very efficient and nondestructive way. We also show that, unlike other techniques, hard x-ray nanotomography allows reconstructing the elemental distribution over a wide range of atomic number and offers truly depth resolution capabilities. The sensitivity, 3D resolution, and complementarity of our approach make hard x-ray nanotomography an essential characterization tool for a large panel of scientific domains.

36 MATERIALS SCIENCE↗

Leveraging 3D CAD and Virtual Reality in Design of the Calcine Disposition Project - 20512

Fluor Idaho's Calcine Disposition Project (CDP) is leveraging the power of three-dimensional (3D) visualization, light detection and ranging (Lidar), and virtual reality to improve designs and worker safety. With the use of computer-aided design (CAD) modeling software, the CDP has created 3D models of the facility and systems to aid in the design, development, and operation of its retrieval and transfer system. This by itself is nothing new and has been done in industry for years. The CDP project however is taking this a few steps farther with the use of Lidar and virtual reality software. The CRP is tasked with removing a radioactive granular material from stainless steel bins located in concrete vaults that were constructed in the late 1950's and early 1960's. While construction drawings are available, it is not certain that the drawings are as-built or how accurate they truly are. Part of the project requires precise placement of equipment on to bins around multiple pipe, electrical lines, and bin stiffeners. Relying solely on the existing drawings and models created from these drawings is highly risky and prone to failure. The first step to determine the precise location and orientation of all obstructions in the vault the project will use a Lidar system to scan the vault structure and precisely locate all vault and bin components. Once this information is obtained, the data will be integrated into the CAD model. The model will then be verified, and a true as-built model developed. Precise component location, size, and orientation will be used for final design and placement of retrieval components. The second step will be to take the verified 3D model and scan data and import it into virtual reality software creating a virtual world. While some work on the project requires all work to be completed remotely due to high radiation fields, some areas have low enough radiation levels that personnel can enter and perform work. With the use of a virtual reality headset, operators and technicians will be able to enter our virtual world and become familiar with the surroundings and perform work prior to ever entering the radiation environment. This training is expected to pay dividends by improving worker efficiency, reducing errors, and improving confidence that the work can be performed as expected. It will play a key aspect in as low as reasonably achievable (ALARA) principles. An additional aspect in using the Lidar scans and virtual environment, is that it will give engineers and managers an opportunity to revisit the facility, especially radiation areas, at any time to obtain design information and measurements that may be costly or impossible to obtain once the facility transitions into radiation operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Semi-automatic image annotation using 3D LiDAR projections and depth camera data

Efficient image annotation is necessary to utilize deep learning object recognition neural networks in nuclear safeguards, such as for the detection and localization of target objects like nuclear material containers (NMCs). This capability can help automate the inventory accounting of different types of NMCs within nuclear storage facilities. The conventional manual annotation process is labor-intensive and time-consuming, hindering the rapid deployment of deep learning models for NMC identifications. This paper introduces a novel semi-automatic method for annotating 2D images of nuclear material containers (NMCs) by combining 3D light detection and ranging (LiDAR) data with color and depth camera images collected from a handheld scan system. The annotation pipeline involves an operator manually marking new target objects on a LiDAR-generated map, and projecting these 3D locations to images, thereby automatically creating annotations from the projections. The semi-automatic approach significantly reduces manual efforts and the expertise in image annotation that is required to perform the task, allowing deep learning models to be trained on-site within a few hours. The paper compares the performance of models trained on datasets annotated through various methods, including semi-automatic, manual, and commercial annotation services. The evaluation demonstrates that the semi-automatic annotation method achieves comparable or superior results, with a mean average precision (mAP) above 0.9, showcasing its efficiency in training object recognition models. Additionally, the paper explores the application of the proposed method to instance segmentation, achieving promising results in detecting multiple types of NMCs in various formations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nanomaterial datasets to advance tomography in scanning transmission electron microscopy

Electron tomography in materials science has flourished with the demand to characterize nanoscale materials in three dimensions (3D). Access to experimental data is vital for developing and validating reconstruction methods that improve resolution and reduce radiation dose requirements. This work presents five high-quality scanning transmission electron microscope (STEM) tomography datasets in order to address the critical need for open access data in this field. The datasets represent the current limits of experimental technique, are of high quality, and contain materials with structural complexity. Included are tomographic series of a hyperbranched Co 2 P nanocrystal, platinum nanoparticles on a carbon nanofibre imaged over the complete 180° tilt range, a platinum nanoparticle and a tungsten needle both imaged at atomic resolution by equal slope tomography, and a through-focal tilt series of PtCu nanoparticles. A volumetric reconstruction from every dataset is provided for comparison and development of post-processing and visualization techniques. Researchers interested in creating novel data processing and reconstruction algorithms will now have access to state of the art experimental test data.

36 MATERIALS SCIENCE↗

Morphological and chemical characteristics of oxide scales formed on δ-Phase plutonium metal alloys I: 3.5 at% ga

Focused ion-beam scanning electron microscopy (FIB-SEM) and three-dimensional (3D) microscopy were applied to characterize the subsurface morphological features of oxide scales formed on an ~3.5 at.% Ga plutonium (Pu) metal alloy. Using the FIB-SEM technique, a number of morphological features formed in the interior of the oxide scale from Pu metal's environmental exposure were observed and identified. Here, Auger electron spectroscopy (AES) was utilized to characterize the cross-sectional composition and chemistry of the oxide scale. The oxide scale formed during inert storage and operational environments has a characteristic internal scale structure that includes a relatively dense oxide layer with some lateral and transverse cracking. Generally, after subsequent exposure to dry air environment, the oxide scale retained most of the original structural and chemical characteristics. However, after aging in a moist air environment, while the oxide scale was found to maintain the chemical characteristics of the source oxide, the scale was found to be on average thinner and without the previously observed internal microcracking, likely the result of spallation of the source scale during exposure to the new environment.

36 MATERIALS SCIENCE↗

Morphological and chemical characteristics of oxide scales formed on δ-phase plutonium metal alloys II: 2.0 at% Ga

The focused ion-beam scanning electron microscopy (FIB-SEM) and three-dimensional (3D) microscopy were applied to characterize the subsurface morphological features of oxide scales formed on an ~2.0 at. % Ga plutonium (Pu) metal alloy. Using the FIB-SEM technique, a number of morphological features formed in the interior of the oxide scale from Pu metal’s environmental exposure were observed and identified. Auger electron spectroscopy (AES) was utilized to characterize the cross-sectional composition and chemistry of the oxide scale. The oxide scale formed during inert storage and operational environments was found to be highly variable in thickness and morphology, presenting some regions with a thin (<400 nm), dense oxide layer and others with a thick (>2 µm) scale with substantial lateral cracking. After subsequent exposure to dry air environment, the oxide scale became thicker (~4 µm) and slightly more porous. The changes following aging in a moist air environment were observed to be more severe, with the formation of a highly porous internal structure containing significant lateral and transverse cracking. In comparison to the scale formed on an ~3.5 at. % Ga-Pu metal alloy, the oxide morphology of the lower gallium alloy investigated here exhibited greater variation in thickness and a noteworthy dependence on the presence of water vapor, particularly in terms of the internal porosity formed during growth of the oxide.

36 MATERIALS SCIENCE↗

SU-E-T-633: Dose Differences in Lung Cancer SBRT: The Influences of MLC Width

Purpose: The aim is to compare the plan dose distribution of lung SBRT with MLCs in different width. Methods: Cases with phase INSCLC were enrolled. 9 cases were undergone 4D-CT scanning in the supine position with both arms raised. 3D-CT images without IV contrast were afterwards acquired with 3mm thickness and used for dose calculations. ITV was generated by using the inspiration and expiration images. The ITV can be expanded by geometric set-up uncertainty (5 mm) to generate the PTV. All chest normal tissues including chest wall were contoured by doctors. A total dose of 55 Gy will be given in 5 fractions within 10–14 days with an inter fraction interval of 2–3 days. Guided by the RTOG trial 3502 protocol, 11–13 non-coplanar fields with 6MV photon were arranged. Three types of MLCs with width of 3mm, 5mm and 10mm at isocenter position, were used separately to generate a CRT plan for each case. Monte Carlo algorithm was applied to dose calculation. All plans were adjusted as possible to meet the dose constraints. Dose-volume parameters from plans as followed were compared and analysized: PTV V55Gy, COMPTV D70% (70% of normalization dose), volume A (body minus PTV), and R100% and R50% (the ratio of x% of prescription dose isoline volume to PTV volume). Results: MLCs, 3mm and 5mm wide, played the identical roles on dosimetry of the plans, excluding the parameter volume A (p<0.05). On the contrary, MLC with width of 10mm was significantly inferior to the other two types on most parameters (p<0.05). For R50%, all types contributed equally (p>0.05). Conclusion: For lung cancer SBRT, MLC width had influence to dosimetry, especially in irradiation area. Small size MLC, e.g. 3mm and 5mm, are helpful to generate a high quality treatment plan, which could meet the strict criteria for targets and OAR.

60 APPLIED LIFE SCIENCES↗

Identification of stable adsorption sites and diffusion paths on nanocluster surfaces: an automated scanning algorithm

The diverse coordination environments on the surfaces of discrete, three-dimensional (3D) nanoclusters contribute significantly to their unique catalytic properties. Identifying the numerous adsorption sites and diffusion paths on these clusters is however tedious and time-consuming, especially for large, asymmetric nanoclusters. Here, we present a simple, automated method for constructing approximate 2D potential energy surfaces for the adsorption of atomic species on the surfaces of 3D nanoclusters with minimal human intervention. These potential energy surfaces fully characterize the important adsorption sites and diffusion paths on the nanocluster surfaces with accuracies similar to current approaches and at comparable computational cost. Our method can treat complex nanoclusters, such as alloy nanoclusters, and accounts for cluster relaxation and adsorbate-induced reconstruction, important for obtaining accurate energetics. Moreover, its highly parallelizable nature is ideal for modern supercomputer architectures. We showcase our method using two clusters: Au 18 and Pt 55 . For Au 18 , diffusion of atomic hydrogen between the most stable sites occurs via non-intuitive paths, underlining the necessity of exploring the complete potential energy surface. By enabling the rapid and unbiased assessment of adsorption and diffusion on large, complex nanoclusters, which are particularly difficult to handle manually, our method will help advance materials discovery and the rational design of catalysts.

36 MATERIALS SCIENCE↗

Awake Animal Imaging Motion Tracking Software

The Awake Animal Motion Tracking Software code calculates the 3D movement of the head motion of a live, awake animal during a medical imaging scan. In conjunction with markers attached to the head, images acquired from multiple cameras are processed and marker locations precisely determined. Using off-line camera calibration data, the 3D positions of the markers are calculated along with a 6 degree of freedom position and orientation (pose) relative to a fixed initial position. This calculation is performed in real time at frame rates up to 30 frames per second. A time stamp with microsecond accuracy from a time base source is attached to each pose measurement.

Goddard, James↗