Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

Stereolithographic geometry model of the IBR-2M experimental facility

The IBR-2M is a fast research reactor that operates in supercritical condition for ∼ 800 μs every 200 ms. Two reflector parts in nickel rotate in opposite directions generating 1.8 GWth peak power when they align with the fuel zone changing the reactor status from deep subcritical to supercritical. The reactor core uses high-enriched plutonium fuel and is cooled by sodium. This reactor has been modeled by MCNP and SERPENT computer programs. The MCNP model uses combinatorial geometry, whereas the SERPENT model employs the Stereolithographic (STL) geometry representation that can be used by 3D printers. The STL geometry was constructed using the CUBIT computer program. The CUBIT program was also used for a three-dimensional visualization of the Monte Carlo models. SERPENT and MCNP models use the same geometry, material specifications, and nuclear data. The latter are based on the ENDF/B-7.0 library. SERPENT and MCNP using same geometry and same material specifications produce similar k{sub eff} values within 120 pcm.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Technical Note: Development of a 3D printed subresolution sandwich phantom for validation of brain SPECT analysis

Purpose: To make an adaptable, head shaped radionuclide phantom to simulate molecular imaging of the brain using clinical acquisition and reconstruction protocols. This will allow the characterization and correction of scanner characteristics, and improve the accuracy of clinical image analysis, including the application of databases of normal subjects. Methods: A fused deposition modeling 3D printer was used to create a head shaped phantom made up of transaxial slabs, derived from a simulated MRI dataset. The attenuation of the printed polylactide (PLA), measured by means of the Hounsfield unit on CT scanning, was set to match that of the brain by adjusting the proportion of plastic filament and air (fill ratio). Transmission measurements were made to verify the attenuation of the printed slabs. The radionuclide distribution within the phantom was created by adding {sup 99m}Tc pertechnetate to the ink cartridge of a paper printer and printing images of gray and white matter anatomy, segmented from the same MRI data. The complete subresolution sandwich phantom was assembled from alternate 3D printed slabs and radioactive paper sheets, and then imaged on a dual headed gamma camera to simulate an HMPAO SPECT scan. Results: Reconstructions of phantom scans successfully used automated ellipse fitting to apply attenuation correction. This removed the variability inherent in manual application of attenuation correction and registration inherent in existing cylindrical phantom designs. The resulting images were assessed visually and by count profiles and found to be similar to those from an existing elliptical PMMA phantom. Conclusions: The authors have demonstrated the ability to create physically realistic HMPAO SPECT simulations using a novel head-shaped 3D printed subresolution sandwich method phantom. The phantom can be used to validate all neurological SPECT imaging applications. A simple modification of the phantom design to use thinner slabs would make it suitable for use in PET.

60 APPLIED LIFE SCIENCES↗

Use of Three-Dimensional Ultrasound in the Detection of Breast Tumor Bed Displacement During Radiotherapy

Purpose: To evaluate the feasibility and usefulness of a three-dimensional ultrasound (3D-US) image-guided system in identifying and tracking the tumor bed (TB) for planning and daily localization before radiation delivery for breast cancer. Methods and Materials: Twenty breast cancer patients underwent two CT scans at the time of simulation and just before their boost. Three-dimensional ultrasound images were acquired immediately after the CT scans, to which the images were automatically fused. Three-dimensional ultrasound images were also acquired immediately before treatment. Spatial and temporal TB differences between CT and US were evaluated. Results: The TB was not visible on US and CT in 1 subject who had and 1 subject who had not received chemotherapy before whole-breast radiotherapy. The mean (SD) TB volume overlap was 78% (14%). The mean centroid position of the TB on CT vs. US differed by 0.1, 0.2, and 0.4 mm in the anterior-posterior, left-right, and superior-inferior directions. The mean (SD) absolute radial displacement of the TB on each fraction from the treatment plan was 10.8 (6.3) mm. Conclusions: The TB was well visualized by US for the majority of patients. Clinically insignificant differences in the displacements calculated by paired CT vs. paired US demonstrate the feasibility of using 3D-US. The present study suggests that a 10-mm planning target volume margin could result in undercoverage of the clinical target volumes in 50% of treatments. Multimodality planning and image-guided radiotherapy with US potentially offers an accurate and non-ionizing solution for the daily definition of the TB position during partial-breast irradiation and boost treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional (3D) velocity map imaging: from technique to application

The velocity map imaging (VMI) technique was first introduced by Eppink and Parker in 1997, as an improvement to the original ion imaging method by Houston and Chandler in 1987. The method has gained huge popularity over the past two decades and has become a standard tool for measuring high-resolution translational energy and angular distributions of ions and electrons. VMI has evolved gradually from 2D momentum measurements to 3D measurements with various implementations and configurations. The most recent advancement has brought unprecedented 3D performance to the technique in terms of resolutions (both spatial and temporal), multi-hit capability as well as acquisition speed while maintaining many attractive attributes afforded by conventional VMI such as being simple, cost-effective, visually appealing and versatile. Here, in this tutorial, we will discuss many technical aspects of the recent advancement and its application in probing correlated chemical dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Galaxy Zoo: 3D – crowdsourced bar, spiral, and foreground star masks for MaNGA target galaxies

ABSTRACT The challenge of consistent identification of internal structure in galaxies – in particular disc galaxy components like spiral arms, bars, and bulges – has hindered our ability to study the physical impact of such structure across large samples. In this paper we present Galaxy Zoo: 3D (GZ:3D) a crowdsourcing project built on the Zooniverse platform that we used to create spatial pixel (spaxel) maps that identify galaxy centres, foreground stars, galactic bars, and spiral arms for 29 831 galaxies that were potential targets of the MaNGA survey (Mapping Nearby Galaxies at Apache Point Observatory, part of the fourth phase of the Sloan Digital Sky Surveys or SDSS-IV), including nearly all of the 10 010 galaxies ultimately observed. Our crowdsourced visual identification of asymmetric internal structures provides valuable insight on the evolutionary role of non-axisymmetric processes that is otherwise lost when MaNGA data cubes are azimuthally averaged. We present the publicly available GZ:3D catalogue alongside validation tests and example use cases. These data may in the future provide a useful training set for automated identification of spiral arm features. As an illustration, we use the spiral masks in a sample of 825 galaxies to measure the enhancement of star formation spatially linked to spiral arms, which we measure to be a factor of three over the background disc, and how this enhancement increases with radius.

Masters, Karen L. (ORCID:0000000308469578)↗

Pseudo-automatic Determination of Coronal Mass Ejections’ Kinematics in 3D

Coronal mass ejection (CME) events are among the main drivers of geomagnetic disturbances, and hence play a central role in the Sun–Earth system. Their monitoring and, in particular, the determination of their speed and direction of propagation are key issues for the forecasting of space weather near to Earth. We have implemented a method to track CME events in three dimensions by combining triangulation and tie-pointing analysis with a supervised computer vision algorithm. This novel approach does not rely on any geometric constraint, and eliminates the need for visual identification of the CME boundaries. We applied our method to 17 CME events observed simultaneously by the twin Solar Terrestrial Relations Observatory ( STEREO ) COR2 coronagraph imagers from 2008 December to 2011 November in order to obtain their 3D kinematical characterization (i.e., the velocity vector) along with their morphological properties. About ten of these events have already been analyzed using other methodologies. In these cases, we carried out a thorough comparison with our results and found that, in spite of the different nature and spatial coverage range of the other methods with respect to CORSET3D, the majority of the results agree. We found, however, that three events exhibited discrepancies in the magnitude of the velocity vector, four in the longitudinal direction of propagation, and in only one case was there a discrepancy in latitude. The discrepancies appeared in those cases where quasi-simultaneous, quasi-co-located events were observed in the coronagraphs’ fields of view.

79 ASTRONOMY AND ASTROPHYSICS↗

ElasTool v3.0: Efficient computational and visualization toolkit for elastic and mechanical properties of materials

Efficient computation and visualization of elastic and mechanical properties are crucial in the selection of materials and the design of new materials. Here, the ElasTool v3.0 toolkit marks a significant advancement in the computational analysis and visualization of elastic and mechanical properties of materials, essential in material selection and design. This enhanced version extends beyond standard calculations like elastic tensor, Young's modulus, bulk modulus, and Poisson's ratio. It introduces capabilities for computing minimum thermal conductivity, linear compressibility, rendering the Christoffel equation, and elastic energy density. Notably, it integrates advanced visualization tools, including compatibility with Plotly and Elate web platforms for interactive web-based property exploration. A key feature of ElasTool v3.0 is the implementation of second-order elastic constants (SOECs) for tubular 2D-based nanostructures and nanotubes. Leveraging high-efficiency strain-matrix sets (OHESS), the toolkit now facilitates efficient computation of elastic constants and mechanical properties at both zero and finite temperatures for 1D, 2D, and 3D dimensions. ElasTool is openly accessible on GitHub: https://github.com/gmp007/elastool.

1D, 2D, 3D, and tubular 2D nanostructure and nanot↗

J-GEM optical and near-infrared follow-up of gravitational wave events during LIGO’s and Virgo’s third observing run

The Laser Interferometer Gravitational-wave Observatory Scientific Collaboration and Virgo Collaboration (LVC) sent out 56 gravitational-wave (GW) notices during the third observing run (O3). The Japanese Collaboration for Gravitational wave ElectroMagnetic follow-up (J-GEM) performed optical and near-infrared observations to identify and observe an electromagnetic (EM) counterpart. We constructed a web-based system that enabled us to obtain and share information on candidate host galaxies for the counterpart, and the status of our observations. Candidate host galaxies were selected from the GLADE catalog with a weight based on the 3D GW localization map provided by LVC. We conducted galaxy-targeted and wide-field blind surveys, real-time data analysis, and visual inspection of observed galaxies. We performed galaxy-targeted follow-ups to 23 GW events during O3, and the maximum probability covered by our observations reached 9.8%. Among these, we successfully started observations for 10 GW events within 0.5 days after the detection. This result demonstrates that our follow-up observation has the potential to constrain EM radiation models for a merger of binary neutron stars at a distance of up to ~100 Mpc with a probability area of ≤ 500 deg 2 .

79 ASTRONOMY AND ASTROPHYSICS↗

Projecting GeoVisipedia Annotations onto Satellite Imagey with the PRISM Algorithm

GeoVisipedia is a new and novel approach to sharing knowledge about complex geospatial configurations such as facilities. GeoVisipieda annotates objects in facilities with wiki pages. Annotations are projected to and from facility imagery using the PRISM algorithm. This report describes how the PRISM algorithm uses image metadata and a 3D facility model to perform annotation projection. The report concludes with an illustration of the efficacy of the PRISM algorithm in projecting an annotation onto a stack, and a demonstration of the effects of modeling error.

3D geospatial models↗

Localized Imaging and Mapping for Underwater Fuel Storage Basins - 18364

Current methods for inspection of spent nuclear fuel storage basins involve lowering a single camera for visual inspection of walls and other structures. We present a localized inspection solution where the images are automatically annotated by localization information and a 3D model of the inspected area is generated. The system consists of an underwater sensor pod containing a stereo pair of cameras, light source, inertial measurement unit, and a pressure sensor. The sensors are time synchronized to provide precise measurements. We describe both the sensor pod and the algorithms that keep the pod localized. Preliminary results from in-air testing of a prototype are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3-D advanced gas-cooled nuclear reactor fuel channel reconstruction using structure-from-motion - 110

During planned, periodic outages, a selection of fuel channels within the UK fleet of Advanced Gas-cooled Reactor (AGR) cores are inspected using specialist tools which record video footage and other sensory data for each channel which undergoes inspection. Current visualization techniques comprise of manually produced montages by inspection engineers of points of interest (i.e. structural defects) and 2-D panoramic images of the fuel channels automatically produced using bespoke image stitching software. Both techniques however provide limited structural information due to the loss of depth data as a result of the image formation process. By recovering the depth information from the footage, a 3D model could be constructed and subsequently, allow for more accurate profiling of specific defects observed during inspection in addition to obtaining the fuel channels structure using existing footage. This work explores the preliminary application of a 3-D visualization technique known as Structure-from-Motion (SfM) which aims to obtain 3-D information by exploiting image correspondences across multiple viewpoints of the same scene in the RVI footage. This paper investigates the difficulties of applying state-of-the-art SfM to RVI footage and we present new techniques to improve feature correspondence searching in repetitive, nondescript environments. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Accuracy of UTE-MRI-based patient setup for brain cancer radiation therapy

Purpose: Radiation therapy simulations solely based on MRI have advantages compared to CT-based approaches. One feature readily available from computed tomography (CT) that would need to be reproduced with MR is the ability to compute digitally reconstructed radiographs (DRRs) for comparison against on-board radiographs commonly used for patient positioning. In this study, the authors generate MR-based bone images using a single ultrashort echo time (UTE) pulse sequence and quantify their 3D and 2D image registration accuracy to CT and radiographic images for treatments in the cranium. Methods: Seven brain cancer patients were scanned at 1.5 T using a radial UTE sequence. The sequence acquired two images at two different echo times. The two images were processed using an in-house software to generate the UTE bone images. The resultant bone images were rigidly registered to simulation CT data and the registration error was determined using manually annotated landmarks as references. DRRs were created based on UTE-MRI and registered to simulated on-board images (OBIs) and actual clinical 2D oblique images from ExacTrac™. Results: UTE-MRI resulted in well visualized cranial, facial, and vertebral bones that quantitatively matched the bones in the CT images with geometric measurement errors of less than 1 mm. The registration error between DRRs generated from 3D UTE-MRI and the simulated 2D OBIs or the clinical oblique x-ray images was also less than 1 mm for all patients. Conclusions: UTE-MRI-based DRRs appear to be promising for daily patient setup of brain cancer radiotherapy with kV on-board imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗

3D Virtual Simulation for Radiation Safety and Hazards Identification Training

This presentation will be presented at CAES codebreaker session on May 4th. The slides include two projects that demonstrate how virtual training can benefit from visualization technology. One is a collaboration project between the Applied Visualization Laboratory and College of Eastern Idaho for radiation safety and survey training. The other one is Idaho National Laboratory's hazards identification online training that utilized LiDAR technology.

99 GENERAL AND MISCELLANEOUS↗

Real-time microstructure imaging by Laue microdiffraction: A sample application in laser 3D printed Ni-based superalloys

Synchrotron-based Laue microdiffraction has been widely applied to characterize the local crystal structure, orientation, and defects of inhomogeneous polycrystalline solids by raster scanning them under a micro/nano focused polychromatic X-ray probe. In a typical experiment, a large number of Laue diffraction patterns are collected, requiring novel data reduction and analysis approaches, especially for researchers who do not have access to fast parallel computing capabilities. In this article, a novel approach is developed by plotting the distributions of the average recorded intensity and the average filtered intensity of the Laue patterns. Visualization of the characteristic microstructural features is realized in real time during data collection. As an example, this method is applied to image key features such as microcracks, carbides, heat affected zone, and dendrites in a laser assisted 3D printed Ni-based superalloy, at a speed much faster than data collection. Such analytical approach remains valid for a wide range of crystalline solids, and therefore extends the application range of the Laue microdiffraction technique to problems where real-time decision-making during experiment is crucial (for instance time-resolved non-reversible experiments).

36 MATERIALS SCIENCE↗

3D WHOLE-PROMINENCE FINE STRUCTURE MODELING. II. PROMINENCE EVOLUTION

We use the new three-dimensional (3D) whole-prominence fine structure model to study the evolution of prominences and their fine structures in response to changes in the underlying photospheric magnetic flux distribution. The applied model combines a detailed 3D prominence magnetic field configuration with a realistic description of the prominence plasma distributed along multiple fine structures. In addition, we utilize an approximate Hα visualization technique to study the evolution of the visible cool prominence plasma both in emission (prominence) and absorption (filament). We show that the initial magnetic field configuration of the modeled prominence is significantly disturbed by the changing position of a single polarity of a magnetic bipole as the bipole is advected toward the main body of the filament. This leads to the creation of a barb, which becomes the dominant feature visible in the synthetic Hα images of both the prominence and filament views. The evolution of the bipole also creates conditions that lead to the disappearance and reappearance of large portions of the main body. We also show that an arch-like region containing a dark void (a bubble) can be naturally produced in the synthetic prominence Hα images. While not visible in terms of the magnetic field lines, it is due to a lack of Hα emission from low-pressure, low-density plasma located in shallow magnetic dips lying along the lines of sight intersecting the dark void. In addition, a quasi-vertical small-scale feature consisting of short and deep dips, piled one above the other, is produced.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-D-17A-04: The Impact of Audiovisual Biofeedback On Image Quality During 4D Functional and Anatomic Imaging: Results of a Prospective Clinical Trial

Purpose: The ability of audiovisual (AV) biofeedback to improve breathing regularity has not previously been investigated for functional imaging studies. The purpose of this study was to investigate the impact of AV biofeedback on 4D-PET and 4D-CT image quality in a prospective clinical trial. We hypothesized that motion blurring in 4D-PET images and the number of artifacts in 4D-CT images are reduced using AV biofeedback. Methods: AV biofeedback is a real-time, interactive and personalized system designed to help a patient self-regulate his/her breathing using a patient-specific representative waveform and musical guides. In an IRB-approved prospective clinical trial, 4D-PET and 4D-CT images of 10 lung cancer patients were acquired with AV biofeedback (AV) and free breathing (FB). The 4D-PET images in 6 respiratory bins were analyzed for motion blurring by: (1) decrease of GTVPET and (2) increase of SUVmax in 4-DPET compared to 3D-PET. The 4D-CT images were analyzed for artifacts by: (1) comparing normalized cross correlation-based scores (NCCS); and (2) quantifying a visual assessment score (VAS). A two-tailed paired t-test was used to test the hypotheses. Results: The impact of AV biofeedback on 4D-PET and 4D-CT images varied widely between patients, suggesting inconsistent patient comprehension and capability. Overall, the 4D-PET decrease of GTVPET was 2.0±3.0cm3 with AV and 2.3±3.9cm{sup 3} for FB (p=0.61). The 4D-PET increase of SUVmax was 1.6±1.0 with AV and 1.1±0.8 with FB (p=0.002). The 4D-CT NCCS were 0.65±0.27 with AV and 0.60±0.32 for FB (p=0.32). The 4D-CT VAS was 0.0±2.7 (p=ns). Conclusion: A 10-patient study demonstrated a statistically significant reduction of motion blurring of AV over FB for 1/2 functional 4D-PET imaging metrics. No difference between AV and FB was found for 2 anatomic 4D-CT imaging metrics. Future studies will focus on optimizing the human-computer interface and including patient training sessions for improved comprehension and capability. Supported by NIH/NCI R01 CA 093626, Stanford BioX Interdisciplinary Initiatives Program, NHMRC Australia Fellowship, and Kwanjeong Educational Foundation. GE Healthcare provided the Respiratory Gating Toolbox for 4D-PET image reconstruction. Stanford University owns US patent #E7955270 which is unlicensed to any commercial entity.

60 APPLIED LIFE SCIENCES↗

Design and implementation of a data analysis pipeline for paper spray ionization mass spectrometry of UO 2 Cl 2

Ambient mass spectrometry is an emerging characterization method for nuclear materials analysis. SRNL has recently acquired a new JEOL AccuTOF™-DART® LP 4G with a Filter Spray™ front end sample injection system, to develop new methods for ambient mass spectrometry of uranium analytes. Preliminary measurements of uranium-containing samples have demonstrated a need to rapidly evaluate large datasets generated with tailored data analysis scripts. To address this gap a data analysis pipeline written in R within the R Studio environment has been developed. The pipeline comprises a series of processing steps where the data are ingested, analyte peaks of interest are extracted, subsequent ratio and normalization calculations are performed, and results are presented in a series of graphical plots. In detail, the data files containing up to several hundred chronological spectra of a single sample in netCDF format were first extracted into RStudio. Then, initial 3D plots of the data were created in respect to the time, intensity, and mass to charge domains. These graphics serve as an initial easily visualized survey of instrument data. Next, a .csv format file containing the names, masses, and abundances of isotopes of interest were ingested into RStudio and were used to automatically collect intensity values at the mass value. Uranium isotope ratios were plotted against gadolinium isotope ratios (gadolinium was used as an internal standard) and assessed for ion beam stability and intensity. The spectra were filtered by applying a threshold intensity for the 158GdO+ mass channel. A Monte Carlo experiment was performed by creating a theoretical distribution of the data in order to determine the ratio of the uranium isotopes. The results show that the developed data analysis pipeline successfully filters high quality data from overall poor quality runs. Our results also support the idea that paper spray ionization mass spectrometry can be used for both detection and quantification of trace amounts of uranium compounds.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗