Search NASA⌕ Search

SEARCH · Search NASA

Results for “ABERRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Telescope-optical system performance analysis for the Cryogenic Limb Array Etalon Spectrometer (CLAES) on the Upper Atmospheric Research Satellite

A first-order performance analysis of the CLAES telescope-optical system is presented. The experiment involves the passive measurement of earth-limb radiance over a 10-60 km tangent altitude range, and is based on a solid Fabry-Perot spectrometer which provides spectral resolution of 0.25/cm for atmospheric emission spectroscopy over the 3.5-12 micron IR range. The optical system is required to provide a high degree of off-axis rejection and stray-light control, primarily to suppress intense emission from the earth surface. The astigmatism and other geometric aberrations are corrected by a secondary mirror which produces an excellent image of the primary one, allowing for location of a diffraction control or Lyot stop. The off-axis scattering performance of the telescope is examined in terms of the mirror scatter coefficient and point source rejection ratio. A mirror bidirectional reflectance distribution function of 0.0001 at 1 deg with a 1/theta-squared roll-off between 1 and 0.2 deg is realizable based on recent measurements. This results in an off-axis radiance term that is generally small in comparison with the system-limiting NER.

Roche, A. E.↗

A mirror mount for cryogenic environments

The finite element method was used to study the effect of mount-induced aberrations on the optical surface of a lightweight double arch mirror subjected to cryogenic temperatures. The mount design was controlled by the requirements imposed on the optical surface quality and stress levels. The finite element analysis was used to define the feasible range of mount parameters and the selection of a design within the feasible region. The final design consisted of three spring-loaded Invar T-clamps that uniquely define the location of the mirror, three radially compliant parallel spring guides that remove the effect of radial contraction of structure in cryogenic temperatures, and a flexible baseplate that was used to reduce the effect of temperature-induced baseplate tilt errors. The experimental results from the application of this system to an existing 20-inch fused silica double arch mirror are shown, and possible improvements in system performance are discussed.

Iraninejad, B.↗

A model of the polarization position-angle swings in BL Lacertae objects

The polarization position-angle swings that have been measured in a number of BL Lacertae objects and highly variable quasars are interpreted in terms of shock waves which illuminate (by enhanced synchrotron radiation) successive transverse cross sections of a magnetized, relativistic jet. The jet is assumed to have a nonaxisymmetric magnetic field configuration of the type discussed in the companion paper on the equilibria of force-free jets. For a jet that is viewed at a small angle to the axis, the passage of a shock will give rise to an apparent rotation of the polarization position angle whose amplitude can be substantially larger than 180 deg. The effects of freely propagating shocks are compared with those of bow shocks which form in front of dense obstacles in the jet, and specific applications to 0727 - 115 and BL Lacertae are considered. In the case of 0727 - 115, it is pointed out that the nonuniformity of the swing rate and the apparent oscillations of the degree of polarization could be a consequence of relativistic aberration.

Konigl, A.↗

Test Method for X-Ray Telescopes

Telescopes and X-ray telescopes in particular, tested with nearby point sources of radiation. When point-source rays enter telescope through annular entrance pupil (and under conditions of spherical aberration), ring image produced. Deviation of ring image from perfect circular shape reveals misalinements and surface inaccuracies in telescope. Although particularly suited for grazing-incidence types of systems, this test method applied to other types of optical systems.

Korsch, D.↗

Echelle/Grism Spectrograph

More even spectral dispersion over detector area makes all wavelengths more distinguishable. Proposed echelle spectrograph includes grating/prism combination, called "grism," to make spectral dispersion over detector more even than usually in such instruments. Instrument performance improved, with little additional manufacturing effort. Furthermore, since grism placed within collimated light and its faces are optically flat, introduces no aberrations into optical system.

Dantzler, A. A.↗

Modification of cytogenetic and physiological effects of space flight factors by biologically active compounds

Physiological and cytogenetic changes in the Welsh onion plants induced by a short (82 days) and long term (522 days) space flight are expressed in decrease of seed germination, inhibition of stem growth, depression of cell division in root meristem, and increase in the number of structural chromosome rearrangements. The treatment of such plants with solutions of a-tocopherol, auxin, and kinetin decreased the level of chromosome aberrations to the control one and normalized cell divisions and growth partly or completely.

Aliyev, A. A.↗

Cytogenetic analyses of peripheral lymphocytes subjected to simulated solar flare radiation

Solar flare protons share many radiological health characteristics of the inner Van Allen Belt protons, and both types of radiation pose serious dangers to a number of missions planned. It is appropriate to evaluate crew dose determination procedures in terms of the type of radiation responsible for the major part of the projected exposure, i.e., protons in the neighborhood of 100 MeV. Monitoring chromosome abnormalities in peripheral lymphocytes is one method to determine an individual's accumulated radiation dosage. Cell culture and harvest is a relatively simple procedure and is well within the capabilities of a station health facility, but the evaluation of prepared microscopic slides is a time consuming and subjective procedure. This project is part of an effort to demonstrate the utility of automated image processing and evaluation procedures in expediting dose evaluation. The initial goal of this project is to produce a set of reference chromosome spreads produced from control lymphocytes and from lymphocytes exposed in whole blood to protons or gamma rays. The results of manual and automated aberration scoring will ultimately be compared to test for systematic differences between the two evaluation procedures and between the two radiation qualities. Proton irradiations are performed at the University of Texas Health Science Center at Houston Cyclotron Facility. Proton dosimetry is supplemented by TLD packets from and by assay of short-lived proton activation products in the irradiation blood samples.

Prichard, H. M.↗

Magnetic field properties of the distant magnetotail magnetopause and boundary layer

Models incorporating merging between dayside magnetosheath and magnetosphere field lines predict the location of the magnetotail boundary layer and bending of magnetotail field lines in the direction of the IMF. Previous observations supporting these models are reviewed, and a case of dense magnetotail boundary layer plasma and strongly bent field lines observed by ISEE 3 is examined. Observations of boundary layer plasma within a tangential discontinuity magnetopause are discussed. The model to explain this phenomenon requires that interconnected magnetotail and magnetosheath field lines leave the magnetotail via a narrow 'window'. Field lines in the dense boundary layer plasma veer away from the aberrated x axis more than those in the void magnetotail lobes in order to pass through the windows. Magnetosheath plasma must enter the magnetotail lobes through the windows at all downstream distances in order to supply he observed tailward flux of lobe plasma.

Sibeck, D. G.↗

Near anastigmatic grazing incidence telescope

A performance capability assessment is presently conducted for short versus long grazing incidence telescope designs, in view of the observation that the field curvature and astigmatism that are the primary residual aberrations of a Wolter-type incidence telescope can be substantially reduced through mirror length reduction. A major advantage of the short element telescope is that, if sufficiently short, both the paraboloid and hyperboloid surfaces may be fabricated as a single piece; this significantly facilitates the task of alignment.

Korsch, D.↗

Ubiquitous brecciation after metamorphism in equilibrated ordinary chondrites

Ten objects with aberrant Fe/(Fe + Mg) ratios have been found in apparently unbrecciated types 4-6 H and L chondrites. Since the Fe/(Fe + Mg) ratios of these objects are incompatible with the metamorphic history of the host chondrites, it is concluded that a high proportion of ordinary chondrites are breccias that were lithified after peak metamorphism. This is consistent with the results of Scott (1984), who concluded that most type three ordinary chondrites are breccias of materials with diverse thermal histories, even though they do not show prominent brecciation. It is found that the classification scheme of Van Schmus and Wood (1967) does not identify chondrites with similar thermal histories; the petrologic type of a chondrite is only a measure of the average thermal history of its ingredients. Chondrite and achondrite breccias are also compared in order to understand how brecciation of chondrites after metamorphism is so well camouflaged.

Scott, E. R. D.↗

The warped neutral sheet and plasma sheet in the near-earth geomagnetic tail

An analysis of ISEE 2 plasma and magnetic field data indicates that the plasma sheet and neutral sheet in the near-earth magnetotail are warped in such a manner that in summer (winter) the neutral sheet rises above (dips below) the solar magnetospheric equatorial plane near the center of the tail, but dips below (rises above) the equatorial plane along the tail flanks. In the near tail, the neutral sheet crosses the equatorial plane at about 12 earth radii from the aberrated X axis, considerably closer to the center of the tail than has been inferred from data obtained farther downstream. This increase in the warp with decreasing distance from the earth is consistent with theoretical predictions. In the near tail, the warp is sufficiently strong when the dipole tilt angle is large that even in quiet times the upper or lower edge of the plasma sheet can be found close to the solar magnetospheric equatorial plane along the tail flanks. The seasonal dependence of the warp can produce certain dawn-dusk asymmetries in satellite data which are more apparent than real.

Gosling, J. T.↗

Wide-Angle, Flat-Field Telescope

All-reflective system unvignetted. Wide-angle telescope uses unobstructed reflecting elements to produce flat image. No refracting elements, no chromatic aberration, and telescope operates over spectral range from infrared to far ultraviolet. Telescope used with such image detectors as photographic firm, vidicons, and solid-state image arrays.

Hallam, K. L.↗

Theoretical studies on the mechanical behavior of granular materials under very low intergranular stresses

The salient aspects of the theoretical modeling of a conventional triaxial test (CTC) of a cohesionless granular medium with stress and strain rate loading are described. Included are a controllable gravitational body force and provision for low confining pressure and/or very low intergranular stress. The modeling includes rational, analytic, and numerical phases, all in various stages of development. The numerical evolutions of theoretical models will be used in final design stages and in the analysis of the experimental data. In this the experimental design stage, it is of special interest to include in the candidate considerations every anomaly found in preliminary terrestrial experimentation. Most of the anomalies will be eliminated by design or enhanced for measurement as the project progresses. The main aspect of design being not the physical apparatus but the type and trajectories of loading elected. The major considerations that have been treated are: appearance and growth of local surface aberrations, stress-power coefficients, strain types, optical strain, radial bead migration, and measures of rotation for the proper stress flux.

French, Kenneth W., Jr.↗

Holographic gratings for spectrographic applications: Study of abberations

A computer program was developed that determines the optimum holographic grating recording parameters as a function of optical instrumental parameters and desired wavelength range for Seya-Namioka monochromator mountings. The theory and basic equations for designing holographic concave gratings such that minimization of aberrations of astigmatism or coma over a desired wavelength range may be achieved are presented. The computer program is described, including all of the subroutines. The input data, definitions of terms, and data card description are presented. An example is summarized for using the program and the output data is described in detail.

Bhatia, Manjit S.↗

Neutral sheet crossings by ISEE-3 in the distant magnetotail

The magnetic field data from ISEE-3 in the distant magnetotail at crossings of the field reversal (or neutral sheet) region are analyzed to determine the instantaneous direction of the normal component B(z) at the crossing. Crossings in the middle of the aberrated magnetotail near the apogee A2 of the first deep-tail orbit of ISEE-3 in January-February, 1983 were selected. Data for an interval of one hour is discussed at length to illustrate some of the difficulties that can occur. One particular smooth crossing at 15:56 UT, February 4, 1983, shows that complicated microstructure can occur in times shorter than one minute; averaging over long times may eliminate essential information for this purpose. By inspecting the magnetic field data at the highest resolution, however, it is shown that the direction of the plasma sheet flows and the sense of B(z) across the neutral sheet do not always agree with the reconnection models. Rather, they indicate that the low latitude boundary layer may play a significant role in the dynamics of the magnetotail.

Heikkila, W. J.↗

Time-resolved spectrophotometry of the AM Herculis system E2003 + 225

Time-resolved, medium-resolution photometry is reported for the binary system E2003 + 225 over a complete orbital period in 1984. The object was 1.5-2 mag fainter than when viewed earlier in 1984. The fluxes, equivalent widths and full widths at FWHM for dominant lines are presented for four points in the cycle. A coincidence of emission lines and a 4860 A continuum line was observed for the faster component, which had a 500 km/sec velocity amplitude that was symmetric around the zero line. An aberrant emission line component, i.e., stationary narrow emission lines displaced about 9 A from the rest wavelengths, is modeled as Zeeman splitting of emission from material close to the primary.

Mccarthy, Patrick↗

A grazing incidence extreme ultraviolet spectrometer for use with a diverging beam

Attention is given to the 100-350 A performance of a grazing incidence spectrometer configuration that accepts a diverging beam for the conduct of moderate resolution spectroscopy. Assuming a focal ratio of 10 for the diverging beam, the first optic of the configuration is an off-axis ellipsoid that is used at grazing incidence to refocus the diverging beam and increase the focal ratio. A detailed study is made of the performance of a plane, straight-groove, variable-line-space grating; the aberrations are evaluated analytically and verified by geometrical ray tracing. System resolution is a function of telescope image quality. An optimum design is found by varying six parameters and maximizing the average resolution over the bandpass. The spectrometer can be located far from the optical axis, and fed by a small grazing incidence pick-off mirror.

Hurwitz, Mark↗

A high resolution spectrometer for EUV/FUV wavelengths

The most efficient of the various configurations considered for a high-resolution spaceborne spectrometer for point-source astronomy in the 400-1200-A wavelength region which will fit within an envelope defined by the projected Spartan space platform is a multiple Rowland circle spectrograph, with each of four toroidal gratings respectively intercepting a fraction of the primary mirror beam. Each spectrometer can accept a rather slowly diverging beam, reducing grating aberrations, without further efficiency loss due to additional reflections or magnification. The line densities, detector size, pixel size, etc., of the detector for this instrument are dependent on the drift rate of the space platform; a design optimized for an uncorrected 4-arcsec drift is presented.

Hurwitz, Mark↗