Search NASA⌕ Search

SEARCH · Search NASA

Results for “ADHESIVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Dissimilar Materials Joining of Carbon Fiber Polymer to Dual Phase 980 by Friction Bit Joining, Adhesive Bonding, and Weldbonding

In the present study, joining of a carbon fiber-reinforced polymer and dual phase 980 steel was studied using the friction bit joining, adhesive bonding, and weldbonding processes. The friction bit joining process was optimized for the maximum joint strength by varying the process parameters. Then, the adhesive bonding and weld bonding (friction bit joining plus adhesive bonding) processes were further developed. Lap shear tensile and cross-tension testing were used to assess the joint integrity of each process. Fractured specimens were compared for the individual processes. The microstructures in the joining bit ranged from tempered martensite to fully martensite in the cross-section view of friction bit-joined specimens. Additionally, the thermal decomposition temperature of the as-received carbon fiber composite was studied by thermogravimetric analysis. Fourier-transform infrared–attenuated total reflectance spectroscopy and X-ray diffraction measurements showed minimal variations in the absorption peak and diffraction peak patterns, indicating insignificant thermal degradation of the carbon fiber matrix due to friction bit joining.

36 MATERIALS SCIENCE↗

Shear Strength at 75 F to 500 F of Fourteen Adhesives Used to Bond a Glass-fabric-reinforced Phenolic Resin Laminate to Steel

Fourteen adhesives used to bond a glass-fabric-reinforced phenolic resin laminate to steel were tested in order to determine their shear strengths at temperatures from 75 F to 500 F. Fabrication methods were varied to evaluate the effect of placing cloth between the facing surfaces to maintain a uniform bond-line thickness. One glass-fabric supported phenolic adhesive was found to have a shear strength of 3,400 psi at 300 F and over 1,000 psi at 500 F. Strength and fabrication data are tabulated for all adhesives tested.

PLASTICS↗

Innovative use of adhesive interface characteristics to nondestructively quantify the strength of bonded joints.

Advances in structural adhesives have permitted engineers to contemplate the use of bonded joints in areas that have long been dominated by mechanical fasteners and welds. Although strength, modulus, and toughness have been improved in modern adhesives, the typical concerns with using these polymers still exist. These include concerns over long-term durability and an inability to quantify bond strength (i.e., identify weak bonds) in adhesive joints. Bond deterioration in aging structures and bond strength in original construction are now critical issues that require more than simple flaw detection. Whether the structure involves metallic or composite materials, it is necessary to extend inspections beyond the detection of disbond flaws to include an assessment of the strength of the bond. Use of advanced nondestructive inspection (NDI) methods to measure the mechanical properties of a bonded joint and associated correlations with post-inspection failure tests have provided some clues regarding the key parameters involved in assessing bond strength. Recent advances in ultrasonic- and thermographic-based inspection methods have shown promise for measuring such properties. Specialized noise reduction and signal enhancement schemes have allowed thermographic interrogations to image the subtle differences between bond lines of various strengths. Similarly, specialized ultrasonic (UT) inspection techniques, including laser UT, guided waves, UT spectroscopy, and resonance methods, can be coupled with unique signal analysis algorithms to accurately characterize the properties of weak interfacial bonds. The generation of sufficient energy input levels to derive bond strength variations, the production of sufficient technique sensitivity to measure such minor response variations, and the difficulty in manufacturing repeatable weak bond specimens are all issues that exacerbate these investigations. The key to evaluating the bond strength lies in the ability to exploit the critical characteristics of weak bonds such as nonlinear responses, poor transmission of shear waves, and changes in response to stiffness-based interrogations. This paper will present several ongoing efforts that have identified promising methods for quantifying bond strength and discuss some completed studies that provide a foundation for further evolution in weak bond assessments.

36 MATERIALS SCIENCE↗

Evaluation of Encapsulant Adhesion to Surface Metallization of Photovoltaic Cells: Preprint

Delamination of encapsulant materials from PV cell surfaces often appears to originate at regions with metallization. Using a fracture mechanics based metrology, the adhesion of EVA encapsulant to screen printed silver metallization was evaluated. At room temperature, the fracture energy, Gc [J/m2], of the EVA/silver interface (952 J/m2) was ~70% lower than that of the EVA/AR coating (>2900 J/m2) and ~60% lower than that of the EVA to the surface of cell (2265 J/m2). After only 300 hours of damp heat aging, the adhesion energy of the silver interface dropped to and plateaued at ~50-60 J/m2, while that of the EVA/AR coating and EVA/cell remained mostly unchanged. Elemental surface analysis showed that the EVA separates from the silver in a purely adhesive manner, indicating that bonds at the interface were likely displaced in the presence of humidity and elevated temperature, and may explain the propensity for delamination to occur at metallized surfaces in the field.

14 SOLAR ENERGY↗

Analysis of Adhesive Penetration into Wood using Nano-X-ray Computed Tomography

This paper focused on the penetration of adhesive into cell lumens and cell walls. Douglas-fir samples containing an iodinated phenol-formaldehyde adhesive were analyzed using nano-X-ray computed tomography (XCT), X-ray fluorescence microscopy, and energy-dispersive X-ray spectroscopy to observe adhesive penetration in cell walls. A gradient of penetration was observed within the cell wall structure. Finally, in addition, these nano-XCT datasets were indexed to previous micro-XCT datasets, which gave the ability to link the nanoscale cell wall penetration to microscale penetration in to the porous network of cell lumens.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of Reaction with XeF2 on Surface Adhesion of Al and Al2O3 Surfaces

The change of surface adhesion after fluorination of Al and Al{sub 2}O{sub 3} surfaces using XeF{sub 2} was investigated with atomic force microscopy. The chemical interaction between XeF{sub 2} and Al and Al{sub 2}O{sub 3} surfaces was studied by in situ x-ray photoelectron spectroscopy. Fresh Al and Al{sub 2}O{sub 3} surfaces were obtained by etching top silicon layers of Si/Al and Si/Al{sub 2}O{sub 3} with XeF{sub 2}. The surface adhesion and chemical composition were measured as a function of time after the exposure to air or annealing (at 200 C under vauum). The correlation between the adhesion force increase and presence of AlF{sub 3} on the surface was revealed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Non-Thermal Plasma on Proliferative Activity and Adhesion of Multipotent Stromal Cells to Scaffolds Developed for Tissue-Engineered Constructs

We studied the effect of non-thermal argon plasma on proliferative activity of bone marrow multipotent stromal cells in vitro. Treatment of stromal cell suspension with pure argon did not affect their proliferation. The cells treated with non-thermal argon plasma and explanted in the treatment medium demonstrated growth inhibition by 30-40% in comparison with the control. Multipotent stromal cells treated with plasma and after centrifugation explanted in normal medium within 12 min demonstrated accelerated growth. The total cell growth from the pellet and supernatant significantly exceeded the control values. We also analyzed adhesion and proliferative activity of multipotent stromal cells treated with non-thermal plasma on bioresorbable carriers. The cells adhered and proliferated on all types of studied samples. Adhesion properties of scaffolds differed. Caprolactone was found to be the most suitable material for adhesion and proliferation of multipotent stromal cells.

60 APPLIED LIFE SCIENCES↗

Support of Adhesion Mechanisms in Al 2 O 3 Aerosol Deposition Through Laser-Induced Particle Impact Testing

Aerosol deposition (AD) is a kinetic spray process capable of depositing ceramic coatings at room temperature, but AD process development is generally a laborious exploration of a large process parameter space. Here, this paper presents a case study investigating whether laser-induced particle impact testing (LIPIT) could be applied to expedite development of an alumina (Al 2 O 3 ) coating on nickel (Ni): Specifically, whether LIPIT measurements could predict critical velocities of adhesion on Ni and Al 2 O 3 , and the effect of ball milling the Al 2 O 3 powder. Because LIPIT has a diffraction-limited lower bound on imageable particle size, the usefulness of Al 2 O 3 powder agglomerates as a proxy for single particles was additionally studied. Overall, LIPIT measurements and AD sprays agreed that ball milling dramatically improves adhesion. Additionally, LIPIT measurements of critical velocity of adhesion of Al 2 O 3 powder agglomerates on Ni and Al 2 O 3 substrates (150 meters per second [m/s] and 250 m/s, respectively) quantitatively agreed with predictions from a previously published model based on picoindentation and molecular dynamics simulations. Together, these findings support the established hypothesis that Al 2 O 3 adheres via a dislocation-mediated mechanism in AD, that Al 2 O 3 powder agglomerates adhere as individual constituent particles rather than collectively, and that, for this case study, LIPIT measurements were predictive of AD process parameters.

Al2O3↗

Numerical analysis of a thermal contact problem with adhesion

In this paper, we study a class of dynamic thermal problems involving a frictional normal compliance adhesive contact model and a non-clamped condition for visco-elastic materials. The variational formulation of the problem leads to a general system defined by a second-order quasi-variational evolution inequality on the displacement field coupled with the two first-order evolution equations describing the evolution of the temperature and adhesion. We establish an existence and uniqueness result of the solution on displacement, temperature and adhesion. Then we provide a fully discrete numerical scheme of approximation and derive an error estimate. Finally, various numerical computations are included.

97 MATHEMATICS AND COMPUTING↗

Human epididymis protein 4 (HE4) plays a key role in ovarian cancer cell adhesion and motility

Highlights: Black-Right-Pointing-Pointer We generated stable transduced HE4 overexpression and knockdown cells. Black-Right-Pointing-Pointer HE4 was associated with EOC cell adhesion and motility. Black-Right-Pointing-Pointer HE4 might have some effects on activation of EGFR-MAPK signaling pathway. Black-Right-Pointing-Pointer HE4 play an important role in EOC tumorigenicity. -- Abstract: Human epididymis protein 4 (HE4) is a novel and specific biomarker for epithelial ovarian cancer (EOC). We previously demonstrated that serum HE4 levels were significantly elevated in the majority of EOC patients but not in subjects with benign disease or healthy controls. However, the precise mechanism of HE4 protein function is unknown. In this study, we generated HE4-overexpressing SKOV3 cells and found that stably transduced cells promoted cell adhesion and migration. Knockdown of HE4 expression was achieved by stable transfection of SKOV3 cells with a construct encoding a short hairpin DNA directed against the HE4 gene. Correspondingly, the proliferation and spreading ability of HE4-expressed cells were inhibited by HE4 suppression. Mechanistically, impaired EGFR and Erk1/2 phosphorylation were observed in cells with HE4 knockdown. The phosphorylation was restored when the knockdown cells were cultured in conditioned medium containing HE4. Moreover, in vivo tumorigenicity showed that HE4 suppression markedly inhibited the growth of tumors. This suggests that expression of HE4 is associated with cancer cell adhesion, migration and tumor growth, which can be related to its effects on the EGFR-MAPK signaling pathway. Our results provide evidence of the cellular and molecular mechanisms that may underlie the motility-promoting role of HE4 in EOC progression. The role of HE4 as a target for gene-based therapy might be considered in future studies.

60 APPLIED LIFE SCIENCES↗

Edaravone attenuates monocyte adhesion to endothelial cells induced by oxidized low-density lipoprotein

Oxidized low-density lipoprotein (oxLDL) plays a vital role in recruitment of monocytes to endothelial cells, which is important during early stages of atherosclerosis development. Edaravone, a potent and novel scavenger of free radicals inhibiting hydroxyl radicals, has been clinically used to reduce the neuronal damage following ischemic stroke. In the present study, Edaravone was revealed to markedly reduce oxLDL-induced monocyte adhesion to human umbilical vein endothelial cells (HUVECs). The inhibitory mechanism of Edaravone was associated with suppression of the chemokine MCP-1 and adhesion molecule VCAM-1 and ICAM-1 expression. In addition, luciferase reporter assay results revealed that administration of Edaravone attenuated the increase in NF-κB transcriptional activity induced by oxLDL. Notably, it's also shown that Edaravone treatment blocked oxLDL induced p65 nuclear translocation in HUVECs. Results indicate that Edaravone negatively regulates endothelial inflammation. - Highlights: • Edaravone reduces oxLDL-induced monocyte adhesion to HUVECs. • Edaravone attenuates oxLDL-induced expression of MCP-1, VCAM-1, and ICAM-1. • Edaravone reduces NF-κB transcriptional activity and p65 nuclear translocation.

60 APPLIED LIFE SCIENCES↗

Early osteoinductive human bone marrow mesenchymal stromal/stem cells support an enhanced hematopoietic cell expansion with altered chemotaxis- and adhesion-related gene expression profiles

Bone marrow (BM) microenvironment has a crucial role in supporting hematopoiesis. Here, by using a microarray analysis, we demonstrate that human BM mesenchymal stromal/stem cells (MSCs) in an early osteoinductive stage (e-MSCs) are characterized by unique hematopoiesis-associated gene expression with an enhanced hematopoiesis-supportive ability. In comparison to BM-MSCs without osteoinductive treatment, gene expression in e-MSCs was significantly altered in terms of their cell adhesion- and chemotaxis-related profiles, as identified with Gene Ontology and Gene Set Enrichment Analysis. Noteworthy, expression of the hematopoiesis-associated molecules CXCL12 and vascular cell adhesion molecule 1 was remarkably decreased in e-MSCs. e-MSCs supported an enhanced expansion of CD34{sup +} hematopoietic stem and progenitor cells, and generation of myeloid lineage cells in vitro. In addition, short-term osteoinductive treatment favored in vivo hematopoietic recovery in lethally irradiated mice that underwent BM transplantation. e-MSCs exhibited the absence of decreased stemness-associated gene expression, increased osteogenesis-associated gene expression, and apparent mineralization, thus maintaining the ability to differentiate into adipogenic cells. Our findings demonstrate the unique biological characteristics of e-MSCs as hematopoiesis-regulatory stromal cells at differentiation stage between MSCs and osteoprogenitor cells and have significant implications in developing new strategy for using pharmacological osteoinductive treatment to support hematopoiesis in hematopoietic stem and progenitor cell transplantation. - Highlights: • Human BM-MSCs in an early osteoinductive stage (e-MSCs) support hematopoiesis. • Adhesion- and chemotaxis-associated gene signatures are altered in e-MSCs. • Expression of CXCL12 and VCAM1 is remarkably decreased in e-MSCs. • e-MSCs are at differentiation stage between MSCs and osteoprogenitor cells. • Osteoinductive treatment favors hematopoietic recovery after BMT in mice.

60 APPLIED LIFE SCIENCES↗

Cell adhesion properties of human defensins

Highlights: • Human α-Defensin 5 and Human Neutrophil Peptide 1 directly bind to fibronectin. • Human α-Defensin 5 and Human Neutrophil Peptide 1 modulate cell adhesion and cellto-cell interactions. • These properties do not extend to other human defensin peptides. Effector peptides of innate immunity play an important role in host defense. They act directly by inactivating microbes but also link innate to adaptive immunity. A variety of innate immune functions has been described for these peptides, including chemoattraction and cytokine release. In this study, we describe the effect on cell morphology and cell adhesion of human defensins. We find that Human Defensin 5, the major product of specialized gut epithelial cells, causes changes in cell morphology. HD-5 induces cell adhesion, binds to fibronectin and facilitates binding of T cells to intestinal epithelial cells. These effects were found also for a second prominent defensing, termed Human Neutrophil peptide-1, but not for other human defensins.

60 APPLIED LIFE SCIENCES↗

Multifunctional polymer composite coatings and adhesives by incorporating cellulose nanomaterials

Regardless of their applications, polymers are still considered mechanically weak and functionally insufficient for certain demanding coating and adhesive uses. To address those issues, nanomaterials have been extensively studied as reinforcing fillers, which have been proven to effectively promote the performance of polymer coatings/adhesives. However, conventional nanofillers are expensive and non-biodegradable. Meanwhile, cellulose nanomaterials (CNMs), a class of nanomaterials produced from biomass feedstocks, can circumvent the drawbacks of conventional nanofillers. Here, this review paper first focuses on the multi-functionalities CNMs bring to polymer coatings, including mechanical reinforcement (wear resistance and hardness enhancement), gas barrier, flame resistance, corrosion resistance, self-healing (controlled-release), optical regulation, self-cleaning/antifouling, and antimicrobial characteristics. Then we discuss the benefits of CNM addition to polymer adhesives, such as mechanical enhancement, curing promotion, volatile organic compound (VOC) suppression, and electrical conductivity. Finally, we provide insights into future research efforts with CNMs. The goal of this paper is to promote the pilot-scale study and commercial use of CNMs as multifunctional additives in green and sustainable polymer composite coating and adhesive formulations.

36 MATERIALS SCIENCE↗

Irradiation of ultrasonic sensors and adhesive couplants for application in light water reactor primary loop piping and components

The Electric Power Research Institute (EPRI) Nuclear Sector and US Department of Energy Light Water Reactor Sustainability Program are committed to engaging in research and development endeavors to address materials aging issues specific to long term operation of light water power reactors. To this effect, EPRI launched an industry initiative to develop nondestructive evaluation systems for online monitoring of existing cracks in light water reactor primary coolant loop piping and components. One of the goals of this initiative is to develop a sensor system (or systems) that can determine nondestructively if cracks are growing or arrested and, in the case of the former, to characterize their growth rates. A missing component of this initiative is an experimental assessment of how sensors and adhesive couplants will perform in service when exposed to chronic energetic neutron radiation, particularly at the primary coolant loop hot and cold leg dissimilar metal welds, which join the primary loop piping to the reactor pressure vessel and reside in the vicinity of the reactor core. The objective of this experimental study was to determine how ultrasonic transducers and adhesive couplants perform when exposed to irradiation in a test reactor to simulate and accelerate in-service exposure. Further, to achieve this objective, the signal stability of piezoelectric transducers and performance of adhesive couplants as a function of accumulated fast neutron fluence were characterized by collecting ultrasonic data in-situ during irradiation. Of particular interest were the ultrasonic signal quality and time decay of the amplitude of acoustic reflections as a function of fast neutron fluence. The results of the study showed that, of the 8 transducer/substrate sample assemblies tested, only 3 generated usable ultrasonic signals through the conclusion of the irradiation campaign. It was found that high temperature epoxy tends to ultrasonically couple the sensors to the substrates better than three types of refractory ceramic cements studied, as is supported by post irradiation examination. The results obtained through this experimental study will be utilized in the achievement of the overall goal of development of a sensor system to perform online monitoring of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Framework for Predicting the Photodegradation of Adhesion of Silicone Encapsulants

We developed a framework to predict and model the photodegradation of adhesion and cohesion of a silicone encapsulant for concentrator photovoltaic applications. Silicone encapsulant specimens were artificially weathered under narrow band UV filters to determine the effects of individual wavelengths within the UV spectrum on the photodegradation of the cohesion of encapsulant material and its adhesion with adjacent interfaces. The threshold wavelength, signifying the upper bound of the damaging action spectrum for the silicone, was identified from the results. In addition, specimens were artificially weathered with different relative humidities to understand the effects of moisture on the rate of photodegradation. The adhesion energy was measured using a fracture mechanics approach. The complementary delaminated surfaces were characterized to determine the failure pathway and chemistry changes resulting from photodegradation. A previously developed model was modified to account for the effects of damaging wavelengths in the terrestrial solar spectrum and reciprocity law failure due to varying UV intensity during weathering. With these modifications, the model showed good agreement with the behavior of the silicone encapsulant exposed in an outdoor solar concentrator simulating concentrator photovoltaics operating conditions. Similar studies can be adopted to develop models that can have high predictive accuracies based on accelerated aging studies.

14 SOLAR ENERGY↗

Adhesion, structure, and mechanical properties of Cr HiPIMS and cathodic arc deposited coatings on SiC

Chromium deposited by high-power impulse magnetron sputtering (HIPIMS) versus cathodic arc (CA) processes exhibits very different mechanical properties. Combining the two can result in a single-phase with superior performance that can be tailored for use in coating SiC for advanced nuclear fuel cladding. Coating morphology, residual stress, elemental depth profiles, and mechanical testing by scratch, pull-off adhesion, and microcantilevers are shown for HiPIMS, CA, and combined coatings. CA coatings were likely to spall and had lower adhesion strength due to tensile residual stresses but had desirable material properties. Additionally, by depositing an initial layer of Cr by HiPIMS followed by a layer of Cr by CA, a more adherent coating was achieved and some of the stress issues with CA morphology were resolved. Combined coatings withstood at least 80 MPa in pull-off adhesion tests and had maximum failure stress values of 5GPa in microcantilever tests. These results were better than either individual deposition method and point to a hybrid approach being a path forward for a more robust coating.

36 MATERIALS SCIENCE↗

Disruption of the novel gene fad104 causes rapid postnatal death and attenuation of cell proliferation, adhesion, spreading and migration

The molecular mechanisms at the beginning of adipogenesis remain unknown. Previously, we identified a novel gene, fad104 (factor for adipocyte differentiation 104), transiently expressed at the early stage of adipocyte differentiation. Since the knockdown of the expression of fad104 dramatically repressed adipogenesis, it is clear that fad104 plays important roles in adipocyte differentiation. However, the physiological roles of fad104 are still unknown. In this study, we generated fad104-deficient mice by gene targeting. Although the mice were born in the expected Mendelian ratios, all died within 1 day of birth, suggesting fad104 to be crucial for survival after birth. Furthermore, analyses of mouse embryonic fibroblasts (MEFs) prepared from fad104-deficient mice provided new insights into the functions of fad104. Disruption of fad104 inhibited adipocyte differentiation and cell proliferation. In addition, cell adhesion and wound healing assays using fad104-deficient MEFs revealed that loss of fad104 expression caused a reduction in stress fiber formation, and notably delayed cell adhesion, spreading and migration. These results indicate that fad104 is essential for the survival of newborns just after birth and important for cell proliferation, adhesion, spreading and migration.

60 APPLIED LIFE SCIENCES↗