Search NASA⌕ Search

SEARCH · Search NASA

Results for “AFM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

High speed nano-metrology

For manufacturing at the nanometre scale a method for rapid and accurate measurement of the resultant functional devices is required. Although atomic force microscopy (AFM) has the requisite spatial resolution, it is severely limited in scan speed, the resolution and repeatability of vertical and lateral measurements being degraded when speed is increased. Here we present a new approach to AFM that makes a direct and feedback-independent measurement of surface height using a laser interferometer focused onto the back of the AFM tip. Combining this direct height measurement with a passive, feedback-free method for maintaining tip-sample contact removes the constraint on scan speed that comes from the bandwidth of the z-feedback loop. Conventional laser reflection detection is used for feedback control, which now plays the role of minimising tip-sample forces, rather than producing the sample topography. Using the system in conjunction with a rapid scanner, true height images are obtained with areas up to (36 x 36) {mu}m{sup 2} at 1 image/second, suitable for in-line applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation between resistance-change effect in transition-metal oxides and secondary-electron contrast of scanning electron microscope images

Conductive atomic-force microscopy (C-AFM) writing is attracting attention as a technique for clarifying the switching mechanism of resistive random-access memory by providing a wide area filled with filaments, which can be regarded as one filament with large radius. The writing area on a nickel-oxide (NiO) film formed by conductive atomic-force microscopy was observed by scanning electron microscope, and a correlation between the contrast in a secondary-electron image (SEI) and the resistance written by C-AFM was revealed. In addition, the dependence of the SEI contrast on the beam accelerating voltage (V{sub accel}) suggests that the resistance-change effect occurs near the surface of the NiO film. As for the effects of electron irradiation and vacuum annealing on the C-AFM writing area, it was shown that the resistance-change effect is caused by exchange of oxygen with the atmosphere at the surface of the NiO film. This result suggests that the low-resistance and high-resistance areas are, respectively, p-type Ni{sub 1+{delta}}O ({delta} < 0) and insulating (stoichiometric) or n-type Ni{sub 1+{delta}}O ({delta}{>=} 0).

36 MATERIALS SCIENCE↗

Investigation on the antiferromagnetic component in the intrinsic exchange bias in structurally single phase Cr{sub 2}Te{sub 3} thin film

We report the intrinsic exchange bias in structurally single phase Cr{sub 2}Te{sub 3} thin film grown by low temperature molecular beam epitaxy. The hysteresis loop shift is confirmed due to the ferromagnet/antiferromagnet coupling rather than surface spin disorder effect or minor loop effect. The AFM component attributing to the exchange bias stems from the vacancy Cr layer in Cr{sub 2}Te{sub 3} and is of two dimensions. The magnetic properties of the AFM component are investigated by studying the temperature dependence and the measure field dependence of coercivity and hysteresis loop shift. The blocking temperature is determined to be about 110 K. It is found that the two dimensional AFM component would lose its irreversibility for larger applied measure field.

36 MATERIALS SCIENCE↗

The long range voice coil atomic force microscope

Most current atomic force microscopes (AFMs) use piezoelectric ceramics for scan actuation. Piezoelectric ceramics provide precision motion with fast response to applied voltage potential. A drawback to piezoelectric ceramics is their inherently limited ranges. For many samples this is a nonissue, as imaging the nanoscale details is the goal. However, a key advantage of AFM over other microscopy techniques is its ability to image biological samples in aqueous buffer. Many biological specimens have topography for which the range of piezoactuated stages is limiting, a notable example of which is bone. In this article, we present the use of voice coils in scan actuation for an actuation range in the Z-axis an order of magnitude larger than any AFM commercially available today. The increased scan size will allow for imaging an important new variety of samples, including bone fractures.

36 MATERIALS SCIENCE↗

Superhard behaviour, low residual stress, and unique structure in diamond-like carbon films by simple bilayer approach

Simple bilayer approach is proposed for synthesizing hard and superhard diamond-like carbon (DLC) coatings with reduced residual stress. For this, M/DLC bilayer (M = Ti and Cu) structures are grown using hybrid system involving radio frequency (RF)-sputtering and RF-plasma enhanced chemical vapor deposition techniques. Ti/DLC bilayer deposited at negative self bias of 100 V shows superhard behaviour with hardness (H) as 49 GPa. Cu/DLC bilayer grown at self bias of 100 V exhibits hard behaviour with H as 22.8 GPa. The hardness of Ti/DLC (Cu/DLC) bilayer gets changed from superhard (hard) to hard (moderate hard) regime, when the self bias is raised to 300 V. Residual stress in Ti/DLC (Cu/DLC) bilayer is found to be significantly low that varies in the range of 1 GPa-1.65 GPa (0.8 GPa-1.6 GPa). The microstructure and morphology are studied by Raman spectroscopy, scanning electron microscopy (SEM), and atomic force microscopy (AFM). SEM and AFM pictures reveal the creation of nanostructured features in the deposited bilayers. Raman, SEM, and AFM analyses are correlated with the nano-mechanical properties. Owing to excellent nano-mechanical properties, these bilayers can find their direct industrial applications as hard and protective coatings.

36 MATERIALS SCIENCE↗

An atomic force microscopy-based method for line edge roughness measurement

With the constant decrease of semiconductor device dimensions, line edge roughness (LER) becomes one of the most important sources of device variability and needs to be controlled below 2 nm for the future technological nodes of the semiconductor roadmap. LER control at the nanometer scale requires accurate measurements. We introduce a technique for LER measurement based upon the atomic force microscope (AFM). In this technique, the sample is tilted at about 45 Degree-Sign and feature sidewalls are scanned along their length with the AFM tip to obtain three-dimensional images. The small radius of curvature of the tip together with the low noise level of a laboratory AFM result in high resolution images. Half profiles and LER values on all the height of the sidewalls are extracted from the 3D images using a procedure that we developed. The influence of sample angle variations on the measurements is shown to be small. The technique is applied to the study of a full pattern transfer into a simplified gate stack. The images obtained are qualitatively consistent with cross-section scanning electron microscopy images and the average LER values agree with that obtained by critical dimension scanning electron microscopy. In addition to its high resolution, this technique presents several advantages such as the ability to image the foot of photoresist lines, complex multi-layer stacks regardless of the materials, and deep re-entrant profiles.

36 MATERIALS SCIENCE↗

The extended wedge method: Atomic force microscope friction calibration for improved tolerance to instrument misalignments, tip offset, and blunt probes

One of the major challenges in understanding and controlling friction is the difficulty in bridging the length and time scales of macroscale contacts and those of the single asperity interactions they comprise. While the atomic force microscope (AFM) offers a unique ability to probe tribological surfaces in a wear-free single-asperity contact, instrument calibration challenges have limited the usefulness of this technique for quantitative nanotribological studies. A number of lateral force calibration techniques have been proposed and used, but none has gained universal acceptance due to practical considerations, configuration limitations, or sensitivities to unknowable error sources. This paper describes a simple extension of the classic wedge method of AFM lateral force calibration which: (1) allows simultaneous calibration and measurement on any substrate, thus eliminating prior tip damage and confounding effects of instrument setup adjustments; (2) is insensitive to adhesion, PSD cross-talk, transducer/piezo-tube axis misalignment, and shear-center offset; (3) is applicable to integrated tips and colloidal probes; and (4) is generally applicable to any reciprocating friction coefficient measurement. The method was applied to AFM measurements of polished carbon (99.999% graphite) and single crystal MoS{sub 2} to demonstrate the technique. Carbon and single crystal MoS{sub 2} had friction coefficients of {mu}= 0.20 {+-} 0.04 and {mu}= 0.006 {+-} 0.001, respectively, against an integrated Si probe. Against a glass colloidal sphere, MoS{sub 2} had a friction coefficient of {mu}= 0.005 {+-} 0.001. Generally, the measurement uncertainties ranged from 10%-20% and were driven by the effect of actual frictional variation on the calibration rather than calibration error itself (i.e., due to misalignment, tip-offset, or probe radius).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial spectrograms of vibrating atomic force microscopy cantilevers coupled to sample surfaces

Many advanced dynamic Atomic Force Microscopy (AFM) techniques such as contact resonance, force modulation, piezoresponse force microscopy, electrochemical strain microscopy, and AFM infrared spectroscopy exploit the dynamic response of a cantilever in contact with a sample to extract local material properties. Achieving quantitative results in these techniques usually requires the assumption of a certain shape of cantilever vibration. We present a technique that allows in-situ measurements of the vibrational shape of AFM cantilevers coupled to surfaces. This technique opens up unique approaches to nanoscale material property mapping, which are not possible with single point measurements alone.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Exchange bias and antiferromagnetic interfacial exchange coupling in the mixed-spin oxide Li{sub 2/7}Ni{sub 5/7}O

We present a detailed study on magnetic properties of mixed spin oxide Li{sub 2/7}Ni{sub 5/7}O, where small ferromagnetic (FM) clusters (with averaged diameter of ∼18 Å) immersed with an antiferromagnetic (AFM) host. The exchange bias (EB) with shifts of the hysteresis loop along both the field and magnetization axes is found, which is due to the interfacial interaction between the FM clusters and the AFM host. An AFM interfacial exchange coupling is deduced from the exchange interactions between Ni ions. The type and strength of this interfacial exchange interaction are discussed in terms of the EB at low temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Molecular-scale investigations of structures and surface charge distribution of surfactant aggregates by three-dimensional force mapping

Surface charges on nanoscale structures in liquids, such as biomolecules and nano-micelles, play an essentially important role in their structural stability as well as their chemical activities. These structures interact with each other through electric double layers (EDLs) formed by the counter ions in electrolyte solution. Although static-mode atomic force microscopy (AFM) including colloidal-probe AFM is a powerful technique for surface charge density measurements and EDL analysis on a submicron scale in liquids, precise surface charge density analysis with single-nanometer resolution has not been made because of its limitation of the resolution and the detection sensitivity. Here we demonstrate molecular-scale surface charge measurements of self-assembled micellar structures, molecular hemicylinders of sodium dodecyl sulfate (SDS), by three-dimensional (3D) force mapping based on frequency modulation AFM. The SDS hemicylindrical structures with a diameter of 4.8 nm on a graphite surface were clearly imaged. We have succeeded in visualizing 3D EDL forces on the SDS hemicylinder surfaces and obtaining the molecular-scale charge density for the first time. The results showed that the surface charge on the trench regions between the hemicylinders was much smaller than that on the hemicylinder tops. The method can be applied to a wide variety of local charge distribution studies, such as spatial charge variation on a single protein molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanosecond switching in GeSe phase change memory films by atomic force microscopy

Nanosecond scale threshold switching is investigated with conducting atomic force microscopy (AFM) for an amorphous GeSe film. Switched bits exhibit 2–3 orders of magnitude variations in conductivity, as demonstrated in phase change based memory devices. Through the nm-scale AFM probe, this crystallization was achieved with pulse durations of as low as 15 ns, the fastest reported with scanning probe based methods. Conductance AFM imaging of the switched bits further reveals correlations between the switched volume, pulse amplitude, and pulse duration. The influence of film heterogeneities on switching is also directly detected, which is of tremendous importance for optimal device performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic behaviors in melt spun Fe{sub 52−x}Mn{sub 23+x}Ga{sub 25} (x = 0–3) ribbons

The effect of volume fraction of B2-type ferromagnetic (FM) phase on magnetic behavior of melt-spun Fe{sub 52−x}Mn{sub 23+x}Ga{sub 25} (x = 0, 1, 2, and 3) ribbons has been investigated. X-ray diffraction (XRD) results show that the volume fraction of the B2 phase is decreased, accompanied by the increased antiferromagnetic (AFM) fcc phase, with increasing x. The magnetization isotherms of these ribbons at different temperatures demonstrate that there exists a critical field H{sub CR} from AFM to FM state, and the H{sub CR} decreases and vanishes finally with increasing temperature. High exchange bias field (H{sub EB}) at 10 K through a cooling field at H{sub CR} from 300 K could be found and correlated to the volume fraction of B2-type FM phase. Both H{sub CR} and H{sub EB} are increased with decreasing the amount of B2-type FM phase. The H{sub CR} is increased from 20 kOe for x = 0 to 50 kOe for x = 3, and H{sub EB} is increased from 0.9 kOe for x = 0 to 2.5 kOe for x = 2. The latter phenomenon might be attributed to the change of exchange interactions at FM/AFM interfaces due to the change of proportion of FM and AFM phase at low temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of leakage current paths in n-GaN by conductive atomic force microscopy

We have investigated electrical characteristics of leakage current paths in n-GaN layer grown by metal-organic chemical vapor deposition with conductive-atomic force microscopy (C-AFM). The C-AFM mapping shows two kinds of leakage current paths existing in the n-GaN layer: open-core dislocation and pure screw dislocation. From the localized I-V curves measured by C-AFM, we confirmed that the open-core screw dislocation shows more significant leakage current. We explained these results in terms of a modified Schottky band model based on donor states formed by oxygen segregation at the (10−10) sidewall of the open-core screw dislocation.

36 MATERIALS SCIENCE↗

High-speed spiral imaging technique for an atomic force microscope using a linear quadratic Gaussian controller

This paper demonstrates a high-speed spiral imaging technique for an atomic force microscope (AFM). As an alternative to traditional raster scanning, an approach of gradient pulsing using a spiral line is implemented and spirals are generated by applying single-frequency cosine and sine waves of slowly varying amplitudes to the X and Y-axes of the AFM’s piezoelectric tube scanner (PTS). Due to these single-frequency sinusoidal input signals, the scanning process can be faster than that of conventional raster scanning. A linear quadratic Gaussian controller is designed to track the reference sinusoid and a vibration compensator is combined to damp the resonant mode of the PTS. An internal model of the reference sinusoidal signal is included in the plant model and an integrator for the system error is introduced in the proposed control scheme. As a result, the phase error between the input and output sinusoids from the X and Y-PTSs is reduced. The spirals produced have particularly narrow-band frequency measures which change slowly over time, thereby making it possible for the scanner to achieve improved tracking and continuous high-speed scanning rather than being restricted to the back and forth motion of raster scanning. As part of the post-processing of the experimental data, a fifth-order Butterworth filter is used to filter noises in the signals emanating from the position sensors and a Gaussian image filter is used to filter the images. A comparison of images scanned using the proposed controller (spiral) and the AFM PI controller (raster) shows improvement in the scanning rate using the proposed method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imprinting antivortex states from ferromagnetic Fe into antiferromagnetic NiO in epitaxial NiO/Fe/Ag(001) microstructures

Magnetic vortex and antivortex are the two basic topological states in magnetic systems. While the ferromagnetic (FM) vortex state can be formed spontaneously and be imprinted into an antiferromagnetic (AFM) layer in AFM/FM disks, the antivortex state has never been realized in AFM films. By fabricating single crystalline NiO/Fe/Ag(001) microstructures, we show that the magnetic antivortex state can be created in the Fe microstructures and imprinted into the AFM NiO layer.

36 MATERIALS SCIENCE↗

Initial and secondary oxidation products on the Si(111)-(7 × 7) surface identified by atomic force microscopy and first principles calculations

We investigate the initial and secondary oxidation products on the Si(111)-(7 × 7) surface at room-temperature using atomic force microscopy (AFM) and density functional theory calculations. At the initial oxidation stages, we find that there are two types of bright spots in AFM images. One of them is identified as a Si adatom with one O atom inserted into one of the backbonds, while the other is ascribed to a Si adatom with two inserted O atoms. We observe that the latter one turns into the secondary oxidation product by a further coming O{sub 2} molecule, which appears as a more protruded bright spot. The atomic configuration of this product is identified as Si adatom whose top and all three backbonds make bonds with O atoms. The appearances of initial and secondary oxidation products are imaged as bright and dark sites by scanning tunneling microscopy, respectively. It is revealed that AFM gives us the topographic information close to the real atomic corrugation of adsorbed structures on the semiconductor surfaces.

36 MATERIALS SCIENCE↗

Surface forces: Surface roughness in theory and experiment

A method of incorporating surface roughness into theoretical calculations of surface forces is presented. The model contains two chief elements. First, surface roughness is represented as a probability distribution of surface heights around an average surface height. A roughness-averaged force is determined by taking an average of the classic flat-surface force, weighing all possible separation distances against the probability distributions of surface heights. Second the model adds a repulsive contact force due to the elastic contact of asperities. We derive a simple analytic expression for the contact force. The general impact of roughness is to amplify the long range behaviour of noncontact (DLVO) forces. The impact of the elastic contact force is to provide a repulsive wall which is felt at a separation between surfaces that scales with the root-mean-square (RMS) roughness of the surfaces. The model therefore provides a means of distinguishing between “true zero,” where the separation between the average centres of each surface is zero, and “apparent zero,” defined by the onset of the repulsive contact wall. A normal distribution may be assumed for the surface probability distribution, characterised by the RMS roughness measured by atomic force microscopy (AFM). Alternatively the probability distribution may be defined by the histogram of heights measured by AFM. Both methods of treating surface roughness are compared against the classic smooth surface calculation and experimental AFM measurement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of grain size on charge and magnetic ordering in Bi{sub 0.67}Ca{sub 0.33}MnO{sub 3}

In the present work we report the electron spin resonance(ESR) and magnetic measurements to understand the effect of grain size on the charge ordering (CO), orbital ordering (OO), long range anti ferromagnetic (AFM) ordering in Bi{sub 0.67}Ca{sub 0.33}MnO{sub 3} manganite synthesized by sol-gel method. The temperature dependence of linewidth (ΔH) of the ESR signal and magnetization have been used to get information about magnetic interactions. The CO is suppressed and AFM ordering remains unaffected with increase in grain size of the sample. The competition between FM and AFM correlations is strongly dependent on the grain size of the sample.

36 MATERIALS SCIENCE↗