Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absolute”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Review of deformation behavior of tungsten at temperature less than 0.2 absolute melting temperature

The deformation behavior of tungsten at temperatures 0.2 T sub m is reviewed, with primary emphasis on the temperature dependence of the yield stress and the ductile-brittle transition temperature. It appears that a model based on the high Peierls stress of tungsten best accounts for the observed mechanical behavior at low temperatures. Recent research is discussed which suggests an important role of electron concentration and bonding on the mechanical behavior of tungsten. It is concluded that future research on tungsten should include studies to define more clearly the correlation between electron concentration and mechanical behavior of tungsten alloys and other transition metal alloys.

Stephens, J. R.↗

Absolute ultraviolet spectrophotometry of: alpha CMa, gamma Ori, kappa Ori, and alpha Leo; and a continuing calibration program and some preliminary results

Spectral observations of the stars alpha CMa, gamma Ori, kappa Ori, and alpha Leo have been obtained in the range 1150 to 4000 Angstroms, using rocket borne spectrometers. The payloads have a 13-inch diameter telescope, a rotatable concave diffraction grating, and three pulse counting photomultiplier photometers. The laboratory standards used as photometric references derive their primary calibration directly or indirectly from the National Bureau of Standards. An error range of up to + or - 10 percent is attributed to these laboratory standards; + or - 8 percent to the calibration procedure; and + or - 10 percent is assigned as an accidental error range.

Evans, D. C.↗

Acceptability of VTOL aircraft noise determined by absolute subjective testing

A program was conducted during which test subjects evaluated the simulated sounds of a helicopter, a tilt wing aircraft, and a 15 second, 90 PNdB (indoors) turbojet aircraft used as reference. Over 20,000 evaluations were made while the test subjects were engaged in work and leisure activities. The effects of level, exposure time, distance and aircraft design on subjective acceptability were evaluated. Some of the important conclusions are: (1) To be judged equal in annoyance to the reference jet sound, the helicopter and tilt wing sounds must be 4 to 5 PNdB lower when lasting 15 seconds in duration. (2) To be judged significantly more acceptable than the reference jet sound, the helicopter sound must be 10 PNdB lower when lasting 15 seconds in duration. (3) To be judged significantly more acceptable than the reference jet sound, the tilt wing sound must be 12 PNdB lower when lasting 15 seconds in duration. (4) The relative effect of changing the duration of a sound upon its subjectively rated annoyance diminishes with increasing duration. It varies from 2 PNdB per doubling of duration for intervals of 15 to 30 seconds, to 0.75 PNdB per doubling of duration for intervals of 120 to 240 seconds.

Sternfeld, H., Jr.↗

Absolute frequency of an atomic hydrogen maser clock

An accurate determination was made of the unperturbed atomic hydrogen ground state hyperfine transition frequency (F=1,m=0 - F=0,m=0) in reference to present world wide realizations of internationally defined time interval. In relation to the international atomic time system, the composite value is 1,420,405,751.7755 plus or minus 0.0031 HZ.

Peters, H. E.↗

Absolute ultraviolet spectrophotometry of Alpha Canis Majoris, Gamma Orionis, Kappa Orionis and Alpha Leonis

Spectral observations of the stars Alpha Canis Majoris, Gamma Orionis, Kappa Orionis and Alpha Leonis have been obtained in the range 1150-4000 A, using rocket borne spectrometers. The payloads have a 13-inch diameter telescope, a rotatable concave diffraction grating, and three pulse counting photomultiplier photometers. The observations are systematically lower than those of Carruthers (1968) at 1270 A, of Smith (1967) at 1376 A, and of Campbell (1970) at 2150 and 2550 A. The data are also about 15 percent lower than the ground-based photometry reported by Schild, Peterson and Oke (1971). The OAO-2 short wavelength scanner calibration agrees with the alpha Leo observations, but disagrees for Kappa Ori and Gamma Ori.

Evans, D. C.↗

Piston manometer as an absolute standard for vacuum-gauge calibration.

Determination of total pressure in a calibration volume by measuring the force on a thin circular disk, of accurately-known area, that is freely suspended in a hole in the container wall, so that the disk is substantially flush with the wall. The disk almost fills the hole, so that there is a narrow annular gap. A continuous flow of calibrating gas, injected into the container in order to maintain a desired pressure, passes through the annular gap to a diffusion pump. The ratio of pressures on the two faces of the disk is on the order of 100:1, so that downstream pressure need be known only nominally in order to deduce the upstream pressure. Force on the disk is measured by a balance that is calibrated in situ with dead weights. In one arrangement, pressures in the range from 10 to 500 microtorr were measured with an estimated probable error of (1 microtorr + 1%).

Warshawsky, I.↗

Absolute cross section for the production of O/super 5 S super 0/ by electron impact dissociation of O2.

Estimation of the aeronomically important cross section for the production of O(super 5 S super 0) by electron impact dissociation of O2 on the basis of recently published work of several groups. The cross section reaches a maximum value of 7 x 10 to the minus 18th sq cm plus or minus 50% at about 100 eV. The assumptions made in arriving at this cross section suggest several experiments which might be performed to further refine this estimate.

Wells, W. C.↗

The absolute magnitudes and spectral types of the stars in the gamma Velorum system.

The ratio of the visual luminosities of the O and WC components of the binary system gamma (2) Vel has been derived by comparison of the emission-line strengths in the spectrum with those in the spectrum of a single WC8 star, HD 192103. The result is 1.4 mag, with the O star being brighter; the classification of the O star was found to be 09 I, so that the classification of gamma (2) Vel is WC8+09 I.

Conti, P. S.↗

Absolute measurements of light emission from CO2/+/ and CO in the interaction of He/2 super 3 S/ with CO2.

A flowing afterglow has been used to produce metastable He(2 super 3 S). It is shown that when He(2 super 3 S) interacts with a diatomic or triatomic molecule, its electronic excitation energy can be transferred to electronic and vibrational excitation of the molecule. To examine this mechanism, the rates for the production of electronically excited molecules, observed spectroscopically between 190 and 750 nm in the reaction of He(2 super 3 S) with CO2, have been measured. Results are tabulated.

Wauchop, T. S.↗

Piston manometer as an absolute standard for vacuum-gauge calibration.

Determination of the total pressure in a calibration volume by measuring the force on a thin circular disk, of accurately known area, that is freely suspended in a hole in the container wall, so that the disk is substantially flush with the wall. The disk almost fills the hole, so that there is a narrow annular gap. A continuous flow of calibrating gas, injected into the container in order to maintain a desired pressure, passes through the annular gap to a diffusion pump. The ratio of pressures on the two faces of the disk is of the order of 100:1, so that downstream pressure need be known only nominally in order to deduce the upstream surface. Force on the disk is measured by a balance that is calibrated in situ with dead weights. In one arrangement, pressures in the range from 10 to 500 microtorr were measured with an estimated probable error of (1 microtorr + 1%).

Warshawsky, I.↗

Piston manometer as an absolute standard for vacuum-gage calibration in the range 2 to 500 millitorr

A thin disk is suspended, with very small annular clearance, in a cylindrical opening in the base plate of a calibration chamber. A continuous flow of calibration gas passes through the chamber and annular opening to a downstream high vacuum pump. The ratio of pressures on the two faces of the disk is very large, so that the upstream pressure is substantially equal to net force on the disk divided by disk area. This force is measured with a dynamometer that is calibrated in place with dead weights. A probable error of + or - (0.2 millitorr plus 0.2 percent) is attainable when downstream pressure is known to 10 percent.

Warshawsky, I.↗

Piston manometer as an absolute standard for vacuum gage calibration in the range 10 to 700 microtorr

Total pressure in a calibration chamber is determined by measuring the force on a disk suspended in an orifice in the baseplate of the chamber. The disk forms a narrow annular gap with the orifice. A continuous flow of calibration gas passes through the chamber and annulus to a downstream pumping system. The ratio of pressures on the two faces of the disk exceeds 100:1, so that chamber pressure is substantially equal to the product of disk area and net force on the disk. This force is measured with an electrodynamometer that can be calibrated in situ with dead weights. Probable error in pressure measurement is plus or minus (0.5 microtorr + 0.6 percent).

Warshawsky, I.↗

Absolute rate constant for the O plus NO chemiluminescence in the near infrared

Infrared chemiluminescence from the process O + NO (+M) NO2 + hv (+M) has been studied between 1.3 and 4.1 micrometer. The wavelength dependence of the continuum between 1.3 and 3.3 micrometer is in fair agreement with previous studies and the measured radiative rate constant at 1.51 micrometer establishes the NO-O glow in this spectral range as a secondary emission standard. Comparison with previous studies of the visible region of the glow implies that the overall radiative rate constant lies in the range (9.4 to 11.2) x 10 to the minus 17 power cu cm sec/1. In the region 3.3 to 4.1 micrometer, the previously observed broad band, peaking at 3.7 micrometer, shows a complex kinetic dependence on O and M.

Golde, M. F.↗

DCP-collected absolute target reflectance signatures assist accurate interpretation of ERTS-1 imagery

Data collection platforms (DCP's) are being used at a Black Hills, South Dakota, test site (MMC 226A) to record radiometric measurements needed to determine solar and atmospheric parameters that affect ERTS-1 multispectral scanner radiance measurements. A total of 72 channels of analog data transmitted from an unattended ground truth site via three DCP's at least six times a day. The system has operated with only minor problems since September, sending forth daily measurements of biophysical responses and atmospheric conditions. Comparisons of scene radiance data calculated from ERTS images with that measured on the ground show the image-measured values to be 35 percent higher for the green channel and 20 percent higher for the red channel for the same scene targets. Radiance values for channels 6 and 7 are nearly the same from the ground data and from the imagery.

Weber, F. P.↗